1.
J Hazard Mater ; 464: 133025, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-37995636

RESUMEN

Per- and polyfluoroalkyl substances (PFAS) are used in various industrial products; however, they pose serious health risks. In this study, soil, soil gas, and groundwater samples were collected at a PFAS manufacturing facility in New Jersey, USA, to determine the presence and distribution of PFASs from the soil surface to groundwater and at various distances from the presumed source. Fluorotelomer alcohols (FTOHs) were detected in soil (< 0.26-36.15 ng/g) and soil gas (160-12,000 E µg/m3), while perfluorinated carboxylic acids (PFCAs) were found in soil (4.3-810 ng/g), soil gas (<0.10-180 µg/m3), and groundwater (37-49 µg/L). FTOH and PFCA concentrations decreased as the distance from the presumed source increased, suggesting that PFCAs are likely to migrate in groundwater, whereas FTOHs primarily move in the vapor phase. The presence of PFAS in the groundwater, soil, and soil gas samples indicate its potential for vapor intrusion; thus, some PFAS may contribute to indoor air inhalation exposure. To the best of our knowledge, this is the first report on the quantification of volatile PFAS in soil gas at a PFAS manufacturing facility.

2.
J Air Waste Manag Assoc ; 66(10): 959-70, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27192142

RESUMEN

UNLABELLED: From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/°C, R(2) = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv. IMPLICATIONS: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.


Asunto(s)
Contaminantes Atmosféricos/análisis , Benceno/análisis , Monitoreo del Ambiente , Philadelphia , Estaciones del Año , Tiempo (Meteorología)
3.
Artículo en Inglés | MEDLINE | ID: mdl-32636605

RESUMEN

From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/°C, R2 = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv. IMPLICATIONS: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.