Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Anal Chem ; 96(37): 14935-14943, 2024 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-39221578

RESUMEN

Macrophages consist of a heterogeneous population of functionally distinct cells that participate in many physiological and pathological processes. They exhibit prominent plasticity by changing their different functional phenotypes represented by proinflammatory (M1) and anti-inflammatory (M2) in response to different environmental stimuli. Emerging evidence illustrates the importance of intracellular metabolic pathways in macrophage polarizations and functions. In the tumor microenvironment (TME), macrophages tend to M2 polarization, which promotes tumor growth and leads to adverse physiological effects. Due to the lack of highly specific antigens in M1 and M2 macrophages, significant challenges present in isolating these subtypes from clinical samples or in vitro coculture models of tumor-immune cells. In reverse, the single-cell technique provides the possibility to investigate the factors influencing macrophage polarization in the TME. In this research, we employed inertial microfluidic chip-mass spectrometry (IMC-MS) to conduct single-cell metabolomics analysis of macrophages polarized into the two major phenotypes, respectively, and 213 metabolites were identified in total. Subsequently, differential metabolites between macrophage phenotypes were analyzed using volcano plots and binary logistic regression models. Glutamine was pinpointed as a key metabolite for the M1 and M2 phenotypes. Experimental results from both monoculture and coculture cell models demonstrated that M1 polarization is more reliant on the presence of glutamine in the culture environment than M2 polarization. Glutamine deficiency resulted in failed M1 polarization, while its absence had a less pronounced effect on M2 polarization. Replenishing an appropriate amount of glutamine during the intermediate stages of coculture models significantly enhanced the proportion of M1 polarization and suppressed the growth of tumor cells. This research elucidated glutamine as a key factor influencing macrophage polarization in the TME via single-cell metabolomics based on IMC-MS, offering promising insights and targets for tumor therapies.


Asunto(s)
Macrófagos , Metabolómica , Análisis de la Célula Individual , Microambiente Tumoral , Macrófagos/metabolismo , Macrófagos/inmunología , Metabolómica/métodos , Humanos , Animales , Ratones , Espectrometría de Masas , Glutamina/metabolismo , Dispositivos Laboratorio en un Chip
2.
Adv Sci (Weinh) ; 11(16): e2306659, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38359005

RESUMEN

High-coverage mass spectrometry analysis of single-cell metabolomics remains challenging due to the extremely low abundance and wide polarity of metabolites and ultra-small volume in single cells. Herein, a novel concentric hybrid ionization source, nanoelectrospray ionization-atmospheric pressure chemical ionization (nanoESI-APCI), is ingeniously designed to detect polar and nonpolar metabolites simultaneously in single cells. The source is constructed by inserting a pulled glass capillary coaxially into a glass tube that acts as a dielectric barrier layer. Benefitting from the integrated advantages of nanoESI and APCI, its limit of detection is improved by one order of magnitude to 10 pg mL-1. After the operational parameter optimization, 254 metabolites detected in nanoESI-APCI are tentatively identified from a single cell, and 82 more than those in nanoESI. The developed nanoESI-APCI is successively applied to study the metabolic heterogeneity of human hepatocellular carcinoma tissue microenvironment united with laser capture microdissection (LCM), the discrimination of cancer cell types and subtypes, the metabolic perturbations to glucose starvation in MCF7 cells and the metabolic regulation of cancer stem cells. These results demonstrated that the nanoESI-APCI not only opens a new avenue for high-coverage and high-sensitivity metabolomics analysis of single cell, but also facilitates spatially resolved metabolomics study coupled with LCM.


Asunto(s)
Metabolómica , Análisis de la Célula Individual , Espectrometría de Masa por Ionización de Electrospray , Metabolómica/métodos , Humanos , Análisis de la Célula Individual/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Presión Atmosférica , Nanotecnología/métodos , Células MCF-7 , Carcinoma Hepatocelular/metabolismo , Neoplasias Hepáticas/metabolismo
3.
Clin Chim Acta ; 543: 117304, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36958425

RESUMEN

BACKGROUND: A rapid and accurate measurement approach for 17α-hydroxyprogesterone (17-OHP) and related steroids in amount/volume-limited clinic samples is of importance for precise newborn diagnosis of congenital adrenal hyperplasia (CAH) and its subtypes in clinic. METHODS: Sixteen steroids (17-OHP, androstenedione, cortisol, tetrahydro-11-deoxycortisol, pregnenolone, progesterone, 11-deoxycorticosterone, corticosterone, 21-deoxycortisol, 11-deoxycortisol, dehydroepiandrosterone, testosterone, aldosterone, 17α-hydroxypregnenolone, dihydrotestosterone and 18-hydroxycorticosterone) were included in the panel of high-throughput microbore ultra-performance liquid chromatography-tandem mass spectrometry. Samples were collected from 126 normal subjects and 65 patients including different subtypes of CAH. RESULTS: The method was validated with satisfactory analytical performance in linearity, repeatability, recovery and limit of detection. Reference intervals for 16 steroids were established by quantifying the level of steroids detected in normal infants. The applicability of the method was tested by differentiating steroid metabolic characteristics between normal infants and infants with CAH, as well as between infants with different CAH subtypes. The relevance of 17-OHP, 21-deoxycortisol, and 17-OHP/11-deoxycortisol for 21-hydroxylase deficiency screening was demonstrated. The level of 11-deoxycorticosterone, 11-deoxycortisol, progesterone and androstenedione can be used for the diagnosis of different rare subtypes of CAH. CONCLUSION: This study provides a strategy for highly efficient steroid analysis of amount/volume-limited clinic samples and holds great potential for clinical diagnosis of CAH.


Asunto(s)
Hiperplasia Suprarrenal Congénita , Recién Nacido , Lactante , Humanos , Hiperplasia Suprarrenal Congénita/diagnóstico , Cortodoxona/análisis , Progesterona , Espectrometría de Masas en Tándem/métodos , Androstenodiona , Cromatografía Liquida , Esteroides , 17-alfa-Hidroxiprogesterona , Desoxicorticosterona
4.
Anal Chim Acta ; 1221: 340116, 2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-35934357

RESUMEN

Single cell metabolomics can obtain the metabolic profiles of individual cells and reveal cellular heterogeneity. However, high-throughput single-cell mass spectrometry (MS) analysis under physiological conditions remains a great challenge due to the presence of complex matrix and extremely small cell volumes. Herein, a serpentine channel microfluidic device which was designed to achieve continuous cell separation and inertial focusing, was coupled with a pulsed electric field-induced electrospray ionization-high resolution MS (PEF-ESI-HRMS) to achieve high-throughput single cell analysis. The pulsed square wave electric field was applied to realize on-line cell disruption and induce electrospray ionization. Single cells were analyzed under near-physiological conditions at a throughput of up to 80 cells min-1. More than 900 features were detected and approximately 120 metabolites were tentatively identified from a single cell. Further, by continually analyzing more than 3000 MCF7 and HepG2 cells, discrimination of different cancer cells based on their individual metabolic profiles was achieved by using the principal component analysis. The PEF-ESI-HRMS method was also applied for the analysis of single yeast cells, and more than 40 metabolites were annotated. This method is versatile and has good robustness, which is promising for high-throughput single cell metabolomics analysis.


Asunto(s)
Microfluídica , Espectrometría de Masa por Ionización de Electrospray , Separación Celular , Metaboloma , Metabolómica/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos
5.
Talanta ; 249: 123654, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35696980

RESUMEN

With the increased attention to processing heavy crude oils, a detailed description of chemical composition is critical for the petroleum refining industry. The current analytical technique such as ultrahigh resolution mass spectrometry has been successfully applied for the molecular level characterization of complex petroleum fractions. But the structural characterization of heavy petroleum feedstock is still a great challenge. In this study, a novel in-depth characterization method of nitrogen heterocycles (N-heterocycles) in heavy petroleum mixtures was proposed by online liquid chromatography coupled with electrospray ionization high resolution energy-resolved mass spectrometry. A series of typical basic aromatic, neutral aromatic and naphtheno-aromatic nitrogen heterocyclic model compounds were synthesized to investigate energy-resolved fragmentation behaviors in high energy collision-induced dissociation at 10-100 eV. Energy-dependent fragmentation pathways were elucidated. Notably, characteristic double bond equivalent (DBE) versus carbon number distributions of N1 ions and all CH ions were discovered, which were closely related to their core structure. Then a workflow to assign core structures of alkyl-substituted N-heterocycles in petroleum was proposed and validated. The developed method was applied to investigate the structural isomers in feed and product vacuum gas oil (VGO) fractions. Core structural differences in feed VGO and subtle structural variations between feed and product VGOs were recognized. This work can distinguish structural isomers of N-heterocycles with the subtle difference in their core structure in heavy petroleum fractions based on global energy dimensional fragmentation characteristics.


Asunto(s)
Petróleo , Cromatografía Liquida , Iones , Nitrógeno/química , Petróleo/análisis , Espectrometría de Masas en Tándem/métodos
6.
Anal Chem ; 93(29): 10031-10038, 2021 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-34270220

RESUMEN

Studies of cellular metabolism can provide profound insights into the underlying molecular mechanisms and metabolic function. To date, the majority of cellular metabolism studies based on chromatography-mass spectrometry (MS) require population cells to obtain informative metabolome. These methods are not only time-consuming but also not suitable for amount-limited cell samples such as circulating tumor cells, stem cells, and neurons. Therefore, it is extremely essential to develop analytical methods enabling to detect metabolome from tens of cells in a high-throughput and high-sensitivity way. In this work, a novel platform for rapid and sensitive detection of lipidome in 20 mammalian cells was proposed using capillary microsampling combined with high-resolution spectral stitching nanoelectrospray ionization direct-infusion MS. It can be used to collect cells rapidly and accurately via the capillary microprobe, extract lipids directly in a 96-well plate using a spray solvent, and detect more than 500 lipids covering 19 lipid subclasses within 3 min. This novel platform was successfully applied to study the lipid features of different cancer cell types and subtypes as well as target cells from tissue samples. This study provides a strategy for determining the lipid species with rich information in tens of cells and demonstrates great potential for clinical applications.


Asunto(s)
Metaboloma , Espectrometría de Masa por Ionización de Electrospray , Animales , Humanos , Lipidómica , Lípidos , Fenómenos Físicos
7.
Glob Chall ; 5(4): 2000088, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33854788

RESUMEN

In a Chinese prospective cohort, 500 patients with new-onset type 2 diabetes (T2D) within 4.61 years and 500 matched healthy participants are selected as case and control groups, and randomized into discovery and validation sets to discover the metabolite changes before T2D onset and the related diabetogenic loci. A serum metabolomics analysis reveals that 81 metabolites changed significantly before T2D onset. Based on binary logistic regression, eight metabolites are defined as a biomarker panel for T2D prediction. Pipecolinic acid, carnitine C14:0, epinephrine and phosphatidylethanolamine 34:2 are first found associated with future T2D. The addition of the biomarker panel to the clinical markers (BMI, triglycerides, and fasting glucose) significantly improves the predictive ability in the discovery and validation sets, respectively. By associating metabolomics with genomics, a significant correlation (p < 5.0 × 10-8) between eicosatetraenoic acid and the FADS1 (rs174559) gene is observed, and suggestive correlations (p < 5.0 × 10-6) between pipecolinic acid and CHRM3 (rs535514), and leucine/isoleucine and WWOX (rs72487966) are discovered. Elevated leucine/isoleucine levels increased the risk of T2D. In conclusion, multiple metabolic dysregulations are observed to occur before T2D onset, and the new biomarker panel can help to predict T2D risk.

8.
Adv Sci (Weinh) ; 7(22): 2001714, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33240754

RESUMEN

Diabetic retinopathy (DR) is the main cause of vision loss or blindness in working age adults worldwide. The lack of effective diagnostic biomarkers for DR leads to unsatisfactory curative treatments. To define potential metabolite biomarkers for DR diagnosis, a multiplatform-based metabolomics study is performed. In this study, a total of 905 subjects with diabetes without DR (NDR) and with DR at different clinical stages are recruited. Multiplatform metabolomics methods are used to characterize the serum metabolic profiles and to screen and validate the DR biomarkers. Based on the criteria p < 0.05 and false-discovery rate < 0.05, 348 and 290 metabolites are significantly associated with the pathogenesis of DR and early-stage DR, respectively. The biomarker panel consisting of 12-hydroxyeicosatetraenoic acid (12-HETE) and 2-piperidone exhibited better diagnostic performance than hemoglobin A1c (HbA1c) in differentiating DR from diabetes, with AUCs of 0.946 versus 0.691 and 0.928 versus 0.648 in the discovery and validation sets, respectively. In addition, this panel showed higher sensitivity in early-stage DR detection than HbA1c. In conclusion, this multiplatform-based metabolomics study comprehensively revealed the metabolic dysregulation associated with DR onset and progression. The defined biomarker panel can be used for detection of DR and early-stage DR.

9.
J Chromatogr A ; 1623: 461198, 2020 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-32505287

RESUMEN

Microcystins (MCs) and nodularin (NOD) are tumor promoters produced by cyanobacteria and present in surface water. In this work, a novel mesoporous metal-organic framework-5@chitosan (MOF-5@CS) material was synthesized and applied for the enrichment of MCs and NOD in water and fish samples. The mesoporous MOF-5@CS material was firstly synthesized via a one-step hydrothermal method, and the chitosan was combined with MOF-5 via chemical bonding assembly. As a new adsorbent, the as-synthesized material was found having a large specific surface area and good thermal stability. Under the optimized conditions, MCs and NOD were enriched by the MOF-5@CS material and detected by ultra-performance liquid chromatography-tandem mass spectrometry. The limit of detection of the new method for MCs and NOD were in the range of 0.0018-0.077 ng/mL. The value of relative standard deviation for repeatability were 2.69-6.30%, and the recovery of the analytes ranged from 84.36% to 118.51%. Compared with other reported method for MCs and NOD detection in complex matrices, better adsorption performance for MCs and NOD were obtained by our new method, and the sensitivity of MCs-RR and NOD were improved nearly 20 times and 30 times, respectively.


Asunto(s)
Quitosano/química , Cromatografía Líquida de Alta Presión/métodos , Estructuras Metalorgánicas/química , Microcistinas/análisis , Péptidos Cíclicos/análisis , Espectrometría de Masas en Tándem/métodos , Adsorción , Microcistinas/química , Péptidos Cíclicos/química , Estándares de Referencia , Reproducibilidad de los Resultados , Extracción en Fase Sólida , Espectroscopía Infrarroja por Transformada de Fourier , Contaminantes Químicos del Agua/análisis
10.
J Chromatogr A ; 1614: 460709, 2020 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-31784081

RESUMEN

Steroid hormones are a type of crucial substances that mediate numerous vital physiological functions. The comprehensive detection of steroid hormones can help understand the physiopathologic mechanism of steroid hormone-related diseases. It is very difficult to determine steroid hormones in biological samples due to their low endogenous concentrations and poor ionization efficiency. In this study, an efficient and sensitive approach was developed for profiling steroid hormones by combining liquid-liquid extraction and parallel derivatization with liquid chromatography-tandem mass spectrometry. Methoxyamine and dansyl chloride were used to derivatize steroid hormones containing carbonyl and phenolic hydroxyl groups, respectively. Our established method achieved simultaneous analysis of carbonyl and phenolic hydroxyl-containing steroid hormones and could cover estrogens, androgens, corticoids and progestogens. Twenty-nine steroid hormones were detected at pg/mL levels with the sensitivity enhanced by three orders of magnitude after derivatization. The linearity (with linear range of 2-4 orders of magnitude), precision (less than 15%) and recovery (71.1-128.7%) were satisfactory for quantitative analysis of steroid hormones. Finally, the established method was successfully employed to the determination of steroid hormones in serum samples of healthy males and females as well as ovarian cancer patients. The results showed that this approach was suitable and reliable for routine test of steroid hormones containing carbonyl and phenolic hydroxyl groups.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/métodos , Esteroides/química , Compuestos de Dansilo/química , Femenino , Humanos , Extracción Líquido-Líquido , Masculino , Metoxamina/química , Neoplasias Ováricas/sangre , Neoplasias Ováricas/patología , Progestinas/sangre , Progestinas/química , Progestinas/aislamiento & purificación , Esteroides/sangre , Esteroides/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA