1.
Abdom Radiol (NY) ; 48(9): 2956-2968, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36732408

RESUMEN

Although much radiologic literature has focused on the short-term post-operative complications associated with ileal pouches, as the number of patients with long-term pouches has grown, there is increasing realization of the functional deficits that may occur long after pouch creation. Dynamic pouch imaging using fluoroscopy and MRI can provide assessment of the underlying causes of symptomatic pouch dysfunction and can provide critical insight to the management of this complex patient population. In this paper, we provide an overview of the unique problems encountered in patients with long-term ileal pouches, and provide an overview of the techniques, interpretation, and reporting for fluoroscopic and MR pouch defecography.


Asunto(s)
Reservorios Cólicos , Humanos , Reservorios Cólicos/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Imagen por Resonancia Magnética , Fluoroscopía
2.
AJNR Am J Neuroradiol ; 43(4): 579-584, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35332019

RESUMEN

BACKGROUND AND PURPOSE: Photon-counting detector CT is a new technology with a limiting spatial resolution of ≤150 µm. In vivo comparisons between photon-counting detector CT and conventional energy-integrating detector CT are needed to determine the clinical impact of photon counting-detector CT in temporal bone imaging. MATERIALS AND METHODS: Prospectively recruited patients underwent temporal bone CT examinations on an investigational photon-counting detector CT system after clinically indicated temporal bone energy-integrating detector CT. Photon-counting detector CT images were obtained at an average 31% lower dose compared with those obtained on the energy-integrating detector CT scanner. Reconstructed images were evaluated in axial, coronal, and Pöschl planes using the smallest available section thickness on each system (0.4 mm on energy-integrating detector CT; 0.2 mm on photon-counting detector CT). Two blinded neuroradiologists compared images side-by-side and scored them using a 5-point Likert scale. A post hoc reassignment of readers' scores was performed so that the scores reflected photon-counting detector CT performance relative to energy-integrating detector CT. RESULTS: Thirteen patients were enrolled, resulting in 26 image sets (left and right sides). The average patient age was 63.6 [SD, 13.4] years; 7 were women. Images from the photon-counting detector CT scanner were significantly preferred by the readers in all reconstructed planes (P < .001). Photon-counting detector CT was rated superior for the evaluation of all individual anatomic structures, with the oval window (4.79) and incudostapedial joint (4.75) receiving the highest scores on a Likert scale of 1-5. CONCLUSIONS: Temporal bone CT images obtained on a photon-counting detector CT scanner were rated as having superior spatial resolution and better critical structure visualization than those obtained on a conventional energy-integrating detector scanner, even with a substantial dose reduction.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Femenino , Humanos , Persona de Mediana Edad , Fantasmas de Imagen , Dosis de Radiación , Hueso Temporal/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
3.
Gastroenterology ; 158(1): 137-150.e1, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31476299

RESUMEN

BACKGROUND & AIMS: Stenosis is a common complication of Crohn's disease (CD) that has no effective medical therapy. Development of antifibrotic agents will require testing in randomized controlled trials. Computed tomography enterography- and magnetic resonance enterography-based technologies might be used to measure outcomes in these trials. These approaches have been validated in studies of patients with symptomatic strictures who underwent imaging evaluations followed by resection with histopathologic grading of the intestinal tissue for inflammation and/or fibrosis (the reference standard). Imaging findings have correlated with findings from quantitative or semiquantitative histologic evaluation of the degree of fibromuscular stenosis and/or inflammation on the resection specimen. However, it is not clear whether histologic findings are an accurate reference standard. We performed a systematic review of all published histologic scoring systems used to assess stenosing CD. METHODS: We performed a comprehensive search of Embase and MEDLINE of studies through March 13, 2019, that used a histologic scoring system to characterize small bowel CD and assessed inflammatory and fibrotic alterations within the same adult individual. All scores fitting the criteria were included in our analysis, independent of the presence of stricturing disease, as long as inflammation and fibrosis were evaluated separately but in the same scoring system. RESULTS: We observed substantial heterogeneity among the scoring systems, which were not derived from modern principles for evaluative index development. None had undergone formal validity or reliability testing. None of the existing indices had been constructed according to accepted methods for the development of evaluative indices. Basic knowledge regarding their operating properties were lacking. Specific indices for evaluating the important pathologic component of myofibroblast hypertrophy or hyperplasia have not been proposed. CONCLUSIONS: In a systematic review of publications, we found a lack of validated histopathologic scoring systems for assessment of fibromuscular stenosis. Data that describe the operating properties of existing cross-sectional imaging techniques for stenosing CD should be questioned. Development and validation of a histopathology index is an important research priority.


Asunto(s)
Constricción Patológica/diagnóstico , Enfermedad de Crohn/complicaciones , Íleon/patología , Índice de Severidad de la Enfermedad , Constricción Patológica/etiología , Constricción Patológica/cirugía , Fibrosis , Humanos , Íleon/diagnóstico por imagen , Íleon/cirugía , Imagen por Resonancia Magnética , Estándares de Referencia , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
4.
AJNR Am J Neuroradiol ; 40(11): 1855-1863, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31649155

RESUMEN

BACKGROUND AND PURPOSE: Despite the frequent use of unenhanced head CT for the detection of acute neurologic deficit, the radiation dose for this exam varies widely. Our aim was to evaluate the performance of lower-dose head CT for detection of intracranial findings resulting in acute neurologic deficit. MATERIALS AND METHODS: Projection data from 83 patients undergoing unenhanced spiral head CT for suspected neurologic deficits were collected. Cases positive for infarction, intra-axial hemorrhage, mass, or extra-axial hemorrhage required confirmation by histopathology, surgery, progression of findings, or corresponding neurologic deficit; cases negative for these target diagnoses required negative assessments by two neuroradiologists and a clinical neurologist. A routine dose head CT was obtained using 250 effective mAs and iterative reconstruction. Lower-dose configurations were reconstructed (25-effective mAs iterative reconstruction, 50-effective mAs filtered back-projection and iterative reconstruction, 100-effective mAs filtered back-projection and iterative reconstruction, 200-effective mAs filtered back-projection). Three neuroradiologists circled findings, indicating diagnosis, confidence (0-100), and image quality. The difference between the jackknife alternative free-response receiver operating characteristic figure of merit at routine and lower-dose configurations was estimated. A lower 95% CI estimate of the difference greater than -0.10 indicated noninferiority. RESULTS: Forty-two of 83 patients had 70 intracranial findings (29 infarcts, 25 masses, 10 extra- and 6 intra-axial hemorrhages) at routine head CT (CT dose index = 38.3 mGy). The routine-dose jackknife alternative free-response receiver operating characteristic figure of merit was 0.87 (95% CI, 0.81-0.93). Noninferiority was shown for 100-effective mAs iterative reconstruction (figure of merit difference, -0.04; 95% CI, -0.08 to 0.004) and 200-effective mAs filtered back-projection (-0.02; 95% CI, -0.06 to 0.02) but not for 100-effective mAs filtered back-projection (-0.06; 95% CI, -0.10 to -0.02) or lower-dose levels. Image quality was better at higher-dose levels and with iterative reconstruction (P < .05). CONCLUSIONS: Observer performance for dose levels using 100-200 eff mAs was noninferior to that observed at 250 effective mAs with iterative reconstruction, with iterative reconstruction preserving noninferiority at a mean CT dose index of 15.2 mGy.


Asunto(s)
Encefalopatías/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada Espiral/métodos , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC , Adulto Joven
5.
Aliment Pharmacol Ther ; 48(3): 347-357, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29920726

RESUMEN

BACKGROUND: Fibrotic stricture is a common complication of Crohn's disease (CD) affecting approximately half of all patients. No specific anti-fibrotic therapies are available; however, several therapies are currently under evaluation. Drug development for the indication of stricturing CD is hampered by a lack of standardised definitions, diagnostic modalities, clinical trial eligibility criteria, endpoints and treatment targets in stricturing CD. AIM: To standardise definitions, diagnosis and treatment targets for anti-fibrotic stricture therapies in Chron's disease. METHODS: An interdisciplinary expert panel consisting of 15 gastroenterologists and radiologists was assembled. Using modified RAND/University of California Los Angeles appropriateness methodology, 109 candidate items derived from systematic review and expert opinion focusing on small intestinal strictures were anonymously rated as inappropriate, uncertain or appropriate. Survey results were discussed as a group before a second and third round of voting. RESULTS: Fibrotic strictures are defined by the combination of luminal narrowing, wall thickening and pre-stenotic dilation. Definitions of anastomotic (at site of prior intestinal resection with anastomosis) and naïve small bowel strictures were similar; however, there was uncertainty regarding wall thickness in anastomotic strictures. Magnetic resonance imaging is considered the optimal technique to define fibrotic strictures and assess response to therapy. Symptomatic strictures are defined by abdominal distension, cramping, dietary restrictions, nausea, vomiting, abdominal pain and post-prandial abdominal pain. Need for intervention (endoscopic balloon dilation or surgery) within 24-48 weeks is considered the appropriate endpoint in pharmacological trials. CONCLUSIONS: Consensus criteria for diagnosis and response to therapy in stricturing Crohn's disease should inform both clinical practice and trial design.


Asunto(s)
Consenso , Enfermedad de Crohn/terapia , Testimonio de Experto , Obstrucción Intestinal/diagnóstico , Obstrucción Intestinal/terapia , Guías de Práctica Clínica como Asunto/normas , Cateterismo/métodos , Cateterismo/normas , Ensayos Clínicos como Asunto/normas , Ensayos Clínicos como Asunto/estadística & datos numéricos , Colon/patología , Colon/cirugía , Constricción Patológica/diagnóstico , Constricción Patológica/etiología , Constricción Patológica/terapia , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/diagnóstico , Dilatación/métodos , Dilatación/normas , Endoscopía , Fibrosis/diagnóstico , Fibrosis/etiología , Fibrosis/terapia , Humanos , Obstrucción Intestinal/clasificación , Obstrucción Intestinal/etiología , Intestino Delgado/patología , Intestino Delgado/cirugía , Estándares de Referencia
6.
Neurogastroenterol Motil ; 30(7): e13314, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29498141

RESUMEN

BACKGROUND: Endoanal MRI and MR defecography are used to identify anal sphincter injury and disordered defecation. However, few studies have evaluated findings in asymptomatic healthy people. The effects of BMI and parity on rectoanal motion and evacuation are unknown. METHODS: In 113 asymptomatic females (age 50 ± 17 years, Mean ± SD) without risk factors for anorectal trauma, anal sphincter appearance, anorectal motion, and pelvic organ prolapse were evaluated with MRI. The relationship between age, BMI, and parity and structural findings were evaluated with parametric and non-parametric tests. RESULTS: The anal sphincters and puborectalis appeared normal in over 90% of women. During dynamic MRI, the anorectal angle was 100 ± 1º (Mean ± SEM) at rest, 70 ± 2° at squeeze, and 120 ± 2° during defecation. The change in anorectal angle during squeeze (r = -.25, P < .005), but not during evacuation (r = .13, P = .25) was associated with age. In the multivariable models, BMI (P < .01) and parity (P < .01) were, respectively, independently associated with the intersubject variation in the anorectal angle at rest and the angle change during squeeze. Ten percent or fewer women had had descent of the bladder base or uterus 4 cm or more below the pubococcygeal line or a rectocele measuring 4 cm or larger. Only 5% had a patulous anal canal. CONCLUSIONS: In addition to age, BMI and parity also affect anorectal motion in asymptomatic women. These findings provide age-adjusted normal values for rectoanal anatomy and pelvic floor motion.


Asunto(s)
Canal Anal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Prolapso de Órgano Pélvico/diagnóstico por imagen , Recto/diagnóstico por imagen , Adulto , Factores de Edad , Anciano , Canal Anal/fisiología , Índice de Masa Corporal , Estudios de Cohortes , Defecografía/métodos , Femenino , Voluntarios Sanos , Humanos , Persona de Mediana Edad , Prolapso de Órgano Pélvico/fisiopatología , Recto/fisiología
7.
Abdom Radiol (NY) ; 43(6): 1404-1412, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-28983661

RESUMEN

PURPOSE: Single-energy low tube potential (SE-LTP) and dual-energy virtual monoenergetic (DE-VM) CT images both increase the conspicuity of hepatic lesions by increasing iodine signal. Our purpose was to compare the conspicuity of proven liver lesions, artifacts, and radiologist preferences in dose-matched SE-LTP and DE-VM images. METHODS: Thirty-one patients with 72 proven liver lesions (21 benign, 51 malignant) underwent full-dose contrast-enhanced dual-energy CT (DECT). Half-dose images were obtained using single tube reconstruction of the dual-source SE-LTP projection data (80 or 100 kV), and by inserting noise into dual-energy projection data, with DE-VM images reconstructed from 40 to 70 keV. Three blinded gastrointestinal radiologists evaluated half-dose SE-LTP and DE-VM images, ranking and grading liver lesion conspicuity and diagnostic confidence (4-point scale) on a per-lesion basis. Image quality (noise, artifacts, sharpness) was evaluated, and overall image preference was ranked on per-patient basis. Lesion-to-liver contrast-to-noise ratio (CNR) was compared between techniques. RESULTS: Mean lesion size was 1.5 ± 1.2 cm. Across the readers, the mean conspicuity ratings for 40, 45, and 50 keV half-dose DE-VM images were superior compared to other half-dose image sets (p < 0.0001). Per-lesion diagnostic confidence was similar between half-dose SE-LTP compared to half-dose DE-VM images (p ≥ 0.05; 1.19 vs. 1.24-1.32). However, SE-LTP images had less noise and artifacts and were sharper compared to DE-VM images less than 70 keV (p < 0.05). On a per-patient basis, radiologists preferred SE-LTP images the most and preferred 40-50 keV the least (p < 0.0001). Lesion CNR was also higher in SE-LTP images than DE-VM images (p < 0.01). CONCLUSION: For the same applied dose level, liver lesions were more conspicuous using DE-VM compared to SE-LTP; however, SE-LTP images were preferred more than any single DE-VM energy level, likely due to lower noise and artifacts.


Asunto(s)
Neoplasias Hepáticas/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artefactos , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos
8.
Proc SPIE Int Soc Opt Eng ; 101322017 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-28392614

RESUMEN

Task-based image quality assessment using model observers is promising to provide an efficient, quantitative, and objective approach to CT dose optimization. Before this approach can be reliably used in practice, its correlation with radiologist performance for the same clinical task needs to be established. Determining human observer performance for a well-defined clinical task, however, has always been a challenge due to the tremendous amount of efforts needed to collect a large number of positive cases. To overcome this challenge, we developed an accurate projection-based insertion technique. In this study, we present a virtual clinical trial using this tool and a low-dose simulation tool to determine radiologist performance on lung-nodule detection as a function of radiation dose, nodule type, nodule size, and reconstruction methods. The lesion insertion and low-dose simulation tools together were demonstrated to provide flexibility to generate realistically-appearing clinical cases under well-defined conditions. The reader performance data obtained in this virtual clinical trial can be used as the basis to develop model observers for lung nodule detection, as well as for dose and protocol optimization in lung cancer screening CT.

9.
AJNR Am J Neuroradiol ; 38(4): 672-677, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28183836

RESUMEN

BACKGROUND AND PURPOSE: Given the positive impact of early intervention for craniosynostosis, CT is often performed for evaluation but radiation dosage remains a concern. We evaluated the potential for substantial radiation dose reduction in pediatric patients with suspected craniosynostosis. MATERIALS AND METHODS: CT projection data from pediatric patients undergoing head CT for suspected craniosynostosis were archived. Simulated lower-dose CT images corresponding to 25%, 10%, and 2% of the applied dose were created using a validated method. Three neuroradiologists independently interpreted images in a blinded, randomized fashion. All sutures were evaluated by using 3D volume-rendered images alone, and subsequently with 2D and 3D images together. Reference standards were defined by reader agreement by using routine dose and 2D and 3D images. Performance figures of merit were calculated based on reader response and confidence. RESULTS: Of 33 pediatric patients, 21 had craniosynostosis (39 positive sutures and 225 negative sutures). The mean volume CT dose index was 15.5 ± 2.3 mGy (range, 9.69-19.38 mGy) for the routine dose examination. Average figures of merit for multireader analysis ranged from 0.92 (95% CI, 0.90-0.95) at routine pediatric dose to 0.86 (95% CI, 0.79-0.94) at 2% dose using 3D images alone. Similarly, pooled reader figures of merit ranged from 0.91 (95% CI, 0.89-0.95) at routine pediatric dose to 0.85 (95% CI, 0.76-0.95) at 2% dose using 2D and 3D images together. At 25% and 10% dose, 95% CI of the difference in figures of merit from routine dose included 0, suggesting similar or noninferior performance. CONCLUSIONS: For pediatric head CT for evaluation of craniosynostosis, dose reductions of 75%-90% were possible without compromising observer performance.


Asunto(s)
Craneosinostosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
10.
Am J Gastroenterol ; 110(11): 1589-96, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26416187

RESUMEN

OBJECTIVES: Data on the incidence and natural history of diverticulitis are largely hospital-based and exclude the majority of diverticulitis patients, who are treated in an outpatient setting for uncomplicated diverticulitis. We assessed temporal trends in the epidemiology of diverticulitis in the general population. METHODS: Through the Rochester Epidemiology Project we reviewed the records of all individuals with a diagnosis of diverticulitis from 1980 to 2007 in Olmsted County, Minnesota, USA. RESULTS: In 1980-1989, the incidence of diverticulitis was 115/100,000 person-years, which increased to 188/100,000 in 2000-2007 (P<0.001). Incidence increased with age (P<0.001); however, the temporal increase was greater in younger people (P<0.001). Ten years after the index and second diverticulitis episodes, 22% and 55% had a recurrence, respectively. This recurrence rate was greater in younger people (hazard ratio (HR) per decade 0.63; 95% confidence interval (CI), 0.59-0.66) and women (HR 0.68; 95% CI, 0.58-0.80). Complications were seen in 12%; this rate did not change over time. Recurrent diverticulitis was associated with a decreased risk of complications (P<0.001). Age was associated with increased risk of local (odds ratio (OR) 1.27 per decade; 95% CI, 1.04-1.57) and systemic (OR 1.83; 95% CI, 1.20-2.80) complications. Survival after diverticulitis was lower in older people (P<0.001) and men (P<0.001) and worsened over time (P<0.001). The incidence of surgery for diverticulitis did not change from 1980 to 2007. CONCLUSIONS: The incidence of diverticulitis has increased by 50% in 2000-2007 compared with 1990-1999, and more so in younger people. Complications are relatively uncommon. Recurrent diverticulitis is frequent but typically uncomplicated. Younger people with diverticulitis have less severe disease, more recurrence, and better survival.


Asunto(s)
Diverticulitis del Colon/complicaciones , Diverticulitis del Colon/epidemiología , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Diverticulitis del Colon/cirugía , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Minnesota/epidemiología , Recurrencia , Factores Sexuales , Tasa de Supervivencia/tendencias , Adulto Joven
11.
AJNR Am J Neuroradiol ; 36(11): 2184-90, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26251433

RESUMEN

BACKGROUND AND PURPOSE: Metal-related artifacts from spine instrumentation can obscure relevant anatomy and pathology. We evaluated the ability of CT images reconstructed with and without iterative metal artifact reduction to visualize critical anatomic structures in postoperative spines and assessed the potential for implementation into clinical practice. MATERIALS AND METHODS: We archived CT projection data in patients with instrumented spinal fusion. CT images were reconstructed by using weighted filtered back-projection and iterative metal artifact reduction. Two neuroradiologists evaluated images in the region of spinal hardware and assigned a score for the visualization of critical anatomic structures by using soft-tissue and bone windows (critical structures totally obscured, n = 0; anatomic recognition with high diagnostic confidence, n = 5). Using bone windows, we measured the length of the most pronounced linear artifacts. For each patient, neuroradiologists made recommendations regarding the optimal use of iterative metal artifact reduction and its impact on diagnostic confidence. RESULTS: Sixty-eight patients met the inclusion criteria. Visualization of critical soft-tissue anatomic structures was significantly improved by using iterative metal artifact reduction compared with weighted filtered back-projection (median, 1 ± 1.5 versus 3 ± 1.3, P < .001), with improvement in the worst visualized anatomic structure in 88% (60/68) of patients. There was not significant improvement in visualization of critical osseous structures. Linear metal artifacts were reduced from 29 to 11 mm (P < .001). In 87% of patients, neuroradiologists recommended reconstructing iterative metal artifact reduction images instead of weighted filtered back-projection images, with definite improvement in diagnostic confidence in 32% (22/68). CONCLUSIONS: Iterative metal artifact reduction improves visualization of critical soft-tissue structures in patients with spinal hardware. Routine generation of these images in addition to routine weighted filtered back-projection is recommended.


Asunto(s)
Artefactos , Prótesis e Implantes , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Metales , Persona de Mediana Edad
12.
AJR Am J Roentgenol ; 203(6): W614-22, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25415726

RESUMEN

OBJECTIVE: The purpose of this study was to determine the prevalence of nonpolypoid adenomas and the sensitivity of CT colonography (CTC) in their detection by use of the restricted criteria of height-to-width ratio<50% and height elevation≤3 mm. MATERIALS AND METHODS: In the National CT Colonography Trial (American College of Radiology Imaging Network protocol 6664), a cohort of 2531 participants without symptoms underwent CTC and screening colonoscopy. The CTC examinations were interpreted with both 2D and 3D techniques. Nonpolypoid adenomatous polyps identified with CTC or colonoscopy were retrospectively reviewed to determine which polyps met the restricted criteria. The prevalence of nonpolypoid adenomas and the prospective sensitivity of CTC were determined. Descriptive statistics were used to report the prevalence, size, and histologic features. The sensitivities (with 95% CIs) for nonpolypoid and polypoid lesions were compared by two-sided Z test for independent binomial proportions. RESULTS: The retrospective review confirmed 21 nonpolypoid adenomas, yielding a prevalence of 0.83% (21 of 2531 participants). Eight (38.1%) were advanced adenomas, many (50% [4/8]) only because of large size (≥10 mm). The overall per polyp sensitivity of CTC (combined 2D and 3D interpretation) for detecting nonpolypoid adenomas≥5 mm (n=21) was 0.76; ≥6 mm (n=16), 0.75; and ≥10 mm (n=5), 0.80. These values were not statistically different from the sensitivity of detecting polypoid adenomas (p>0.37). CONCLUSION: In this large screening population, nonpolypoid adenomas had a very low prevalence (<1%), and advanced pathologic features were uncommon in polyps<10 mm in diameter. Most nonpolypoid adenomas are technically visible at CTC. The prospective sensitivity is similar to that for polypoid adenomas when the interpretation combines both 2D and 3D review.


Asunto(s)
Adenoma/diagnóstico por imagen , Adenoma/epidemiología , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/epidemiología , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/epidemiología , Colonografía Tomográfica Computarizada/normas , Anciano , Anciano de 80 o más Años , Colonografía Tomográfica Computarizada/métodos , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Guías de Práctica Clínica como Asunto , Prevalencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estados Unidos/epidemiología
13.
AJNR Am J Neuroradiol ; 35(12): 2237-42, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25082822

RESUMEN

BACKGROUND AND PURPOSE: CT is a ubiquitous, efficient, and cost-effective method to evaluate pediatric ventricular size, particularly in patients with CSF shunt diversion who often need emergent imaging. We therefore sought to determine the minimum dose output or CT dose index required to produce clinically acceptable examinations. MATERIALS AND METHODS: Using a validated noise insertion method and CT projection data from 22 patients, standard pediatric head CT images were reconstructed with weighted filtered back-projection and sinogram-affirmed iterative reconstruction corresponding to routine, 25%, and 10% dose. Reconstructed images were then evaluated by 3 neuroradiologists (blinded to dose and reconstruction method) for ventricular size, diagnostic confidence, image quality, evidence of hemorrhage, and shunt tip location, and compared with the reference standard. RESULTS: There was no significant difference in the ventricular size ranking, and the sensitivity for moderate to severe hydrocephalus was 100%. There was no significant difference between the full-dose level and the ventricular size rankings at the 25% or the 10% dose level for either reconstruction kernel (P > .979). Diagnostic confidence was maintained across doses and kernel. Hemorrhage was more difficult to identify as image quality degraded as dose decreased but was still seen in a majority of cases. Shunts were identified by all readers across all doses and reconstruction methods. CONCLUSIONS: CT images having dose reductions of 90% relative to routine head CT examinations provide acceptable image quality to address the specific clinical task of evaluating ventricular size.


Asunto(s)
Ventriculografía Cerebral/métodos , Hidrocefalia/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Niño , Femenino , Humanos , Masculino , Proyectos Piloto , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
14.
Skeletal Radiol ; 43(3): 297-305, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24337491

RESUMEN

OBJECTIVE: Computed tomography (CT) is used to assess for fracture after knee trauma, but identification of ligamentous injuries may also be beneficial. Our purpose is to assess the potential of dual-energy computed tomography (DECT) for the detection of complete anterior cruciate ligament (ACL) disruption. METHODS: Sixteen patients with unilateral traumatic ACL disruption (average of 58 days following trauma) confirmed by MRI, and 11 control patients without trauma, underwent DECT of both knees. For each knee, axial, sagittal, and oblique sagittal images (with DECT bone removal, single-energy (SE) bone removal, and DECT tendon-specific color mapping) were reconstructed. Four musculoskeletal radiologists randomly evaluated the 324 DECT reconstructed series (54 knees with 6 displays) separately, to assess for ACL disruption using a five-point scale (1 = definitely not torn, to 5 = definitely torn). ROC analysis was used to compare performance across readers and displays. RESULTS: Sagittal oblique displays (mixed kV soft tissue, SE bone removal, and DECT bone removal) demonstrated higher areas under the curve for ACL disruption (AUC = 0.95, 0.93 and 0.95 respectively) without significant differences in performance between readers (p > 0.23). Inter-reader agreement was also better for these display methods (ICC range 0.62-0.69) compared with other techniques (ICC range 0.41-0.57). Mean sensitivity for ACL disruption was worst for DECT tendon-specific color map and axial images (24 % and 63 % respectively). CONCLUSION: DECT knee images with oblique sagittal reconstructions using either mixed kV or bone removal displays (either DECT or SE) depict ACL disruption in the subacute or chronic setting with reliable identification by musculoskeletal radiologists.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/diagnóstico por imagen , Traumatismos de la Rodilla/diagnóstico por imagen , Laceraciones/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Rotura Espontánea/diagnóstico por imagen , Sensibilidad y Especificidad , Adulto Joven
15.
Neurogastroenterol Motil ; 24(10): e467-75, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22765510

RESUMEN

BACKGROUND: Inter-observer variability limits the reproducibility of pelvic floor motion measured by magnetic resonance imaging (MRI). Our aim was to develop a semi-automated program measuring pelvic floor motion in a reproducible and refined manner. METHODS: Pelvic floor anatomy and motion during voluntary contraction (squeeze) and rectal evacuation were assessed by MRI in 64 women with fecal incontinence (FI) and 64 age-matched controls. A radiologist measured anorectal angles and anorectal junction motion. A semi-automated program did the same and also dissected anorectal motion into perpendicular vectors representing the puborectalis and other pelvic floor muscles, assessed the pubococcygeal angle, and evaluated pelvic rotation. KEY RESULTS: Manual and semi-automated measurements of anorectal junction motion (r = 0.70; P < 0.0001) during squeeze and evacuation were correlated, as were anorectal angles at rest, squeeze, and evacuation; angle change during squeeze or evacuation was less so. Semi-automated measurements of anorectal and pelvic bony motion were also reproducible within subjects. During squeeze, puborectalis injury was associated (P ≤ 0.01) with smaller puborectalis but not pelvic floor motion vectors, reflecting impaired puborectalis function. The pubococcygeal angle, reflecting posterior pelvic floor motion, was smaller during squeeze and larger during evacuation. However, pubococcygeal angles and pelvic rotation during squeeze and evacuation did not differ significantly between FI and controls. CONCLUSION & INFERENCES: This semi-automated program provides a reproducible, efficient, and refined analysis of pelvic floor motion by MRI. Puborectalis injury is independently associated with impaired motion of puborectalis, not other pelvic floor muscles in controls and women with FI.


Asunto(s)
Canal Anal/fisiopatología , Defecografía/métodos , Incontinencia Fecal/fisiopatología , Motilidad Gastrointestinal/fisiología , Recto/fisiopatología , Canal Anal/diagnóstico por imagen , Estudios de Casos y Controles , Incontinencia Fecal/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Recto/diagnóstico por imagen
16.
Am J Gastroenterol ; 107(6): 902-11, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22415196

RESUMEN

OBJECTIVES: Current concepts based on referral center data suggest that pelvic floor injury from obstetric trauma is a major risk factor for fecal incontinence (FI) in women. In contrast, a majority of community women only develop FI decades after vaginal delivery, and obstetric events are not independent risk factors for FI. However, obstetric events are imperfect surrogates for anal and pelvic floor injury, which is often clinically occult. Hence, the objectives of this study were to evaluate the relationship between prior obstetric events, pelvic floor injury, and FI among community women. METHODS: In this nested case-control study of 68 women with FI (cases; mean age 57 years) and 68 age-matched controls from a population-based cohort in Olmsted County, MN, pelvic floor anatomy and motion during voluntary contraction and defecation were assessed by magnetic resonance imaging. Obstetric events and bowel habits were recorded. RESULTS: By multivariable analysis, internal sphincter injury (cases-28%, controls-6%; odds ratio (OR): 8.8; 95% confidence interval (CI): 2.3-34) and reduced perineal descent during defecation (cases-2.6 ± 0.2 cm, controls-3.1 ± 0.2 cm; OR: 1.7; 95% CI: 1.2-2.4) increased FI risk, but external sphincter injury (cases-25%, controls-4%; P<0.005) was not independently predictive. Puborectalis injury was associated (P<0.05) with impaired anorectal motion during squeeze, but was not independently associated with FI. Grades 3-4 episiotomy (OR: 3.9; 95% CI: 1.4-11) but not other obstetric events increased the risk for pelvic floor injury. Heavy smoking (≥ 20 pack-years) was associated (P=0.052) with external sphincter atrophy. CONCLUSIONS: State-of-the-art imaging techniques reveal pelvic floor injury or abnormal anorectal motion in a minority of community women with FI. Internal sphincter injury and reduced perineal descent during defecation are independent risk factors for FI. In addition to grades 3-4 episiotomy, smoking may be a potentially preventable, risk factor for pelvic floor injury.


Asunto(s)
Canal Anal/lesiones , Parto Obstétrico/efectos adversos , Episiotomía/efectos adversos , Incontinencia Fecal/etiología , Diafragma Pélvico/lesiones , Diafragma Pélvico/fisiopatología , Anciano , Anciano de 80 o más Años , Canal Anal/patología , Estudios de Casos y Controles , Defecación , Parto Obstétrico/métodos , Episiotomía/métodos , Incontinencia Fecal/patología , Incontinencia Fecal/fisiopatología , Femenino , Humanos , Modelos Lineales , Modelos Logísticos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Minnesota/epidemiología , Análisis Multivariante , Oportunidad Relativa , Diafragma Pélvico/patología , Factores de Riesgo , Fumar/efectos adversos , Factores de Tiempo
17.
Neurogastroenterol Motil ; 22(10): 1094-e284, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20557469

RESUMEN

BACKGROUND: While pelvic floor dysfunction may manifest with bladder or bowel symptoms, the relationship between functional defecatory disorders and dysfunctional voiding is unclear. Our hypothesis was that patients with defecatory disorders have generalized pelvic floor dysfunction, manifesting as dysfunctional urinary voiding. METHODS: Voiding was assessed by a symptom questionnaire, a voiding diary, uroflowmetry, and by measuring the postvoid residual urine volume in this case-control study of 28 patients with a functional defecatory disorder (36 ± 2 years, mean ± SEM) and 30 healthy women (36 ± 2 years). KEY RESULTS: Women with a defecatory disorder frequently reported urinary symptoms: urgency (61%), frequency (36%), straining to begin (21%), or finish (50%) voiding, and the sense of incomplete emptying (54%). Fluid intake and output, the minimum voided volume, and the shortest duration between voids measured by voiding diaries were higher (P < 0.05) in patients than in controls. Uroflowmetry revealed abnormalities in seven controls and 22 patients. The risk of abnormal voiding by uroflowmetry was higher in patients (OR 8.0; 95% CI, 2.3-26.9) than in controls. Patients took longer than controls (P < 0.01) to attain the maximum urinary flow rate (12 ± 2 VS 4 ± 0 s) and to empty the bladder (29 ± 4 VS 20 ± 2 s), but the maximum urinary flow rate and postvoid residual volumes were not significantly different. CONCLUSIONS & INFERENCES: Symptoms of dysfunctional voiding and uroflowmetric abnormalities occurred more frequently, suggesting of disordered urination, in women with a defecatory disorder than in healthy controls.


Asunto(s)
Estreñimiento/complicaciones , Defecación/fisiología , Trastornos Urinarios/complicaciones , Adulto , Canal Anal/fisiopatología , Biorretroalimentación Psicológica , Estudios de Casos y Controles , Enfermedad Crónica , Estreñimiento/fisiopatología , Femenino , Humanos , Masculino , Diafragma Pélvico/fisiopatología , Recto/fisiopatología , Encuestas y Cuestionarios , Micción/fisiología , Urodinámica
18.
Eur J Radiol ; 69(3): 393-7, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19118968

RESUMEN

CT enterography is a modification of conventional CT technique optimized for the evaluation of small bowel. This technique utilizes multidetector scanners with high spatial and temporal resolution; multiplanar reconstructions; and large volumes of enteric contrast to provide bowel distension. This article discusses the essential principles of the exam and its use in the evaluation of Crohn's disease of the small bowel.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Intestinos/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos
19.
Eur Radiol ; 19(5): 1289-95, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19153744

RESUMEN

The aim of this study was to assess the ability of dual-energy computed tomography (DECT) to classify phantom renal lesions as cysts or enhancing masses. Six cylinders ranging in diameter from 0.5 to 3.0 cm were filled with distilled water or titrated iodinated contrast solutions with CT attenuation values at 120 kVp of 0 Hounsfield units (HU) for a cyst proxy or 10, 20, or 40 HU to represent enhancing masses. These were placed in a 12-cm-diameter renal phantom containing puréed beef mixed with iodinated contrast medium to simulate enhancing renal parenchyma of 100 and 250 HU and submerged within a 28-cm water bath. These combinations produced 48 individual phantom renal lesions of differing sizes, internal and parenchymal enhancement (12 cysts and 36 enhancing masses). DECT using 80 and 140 kVp was performed on a dual-source CT scanner. Commercial software created a color-encoded overlay indicating the location of iodine within the phantom. The lesions were individually graded as a cyst or enhancing mass by blinded, consensus interpretation of two genitourinary radiologists. Thirty-five of 36 enhancing masses and 10/12 cysts were correctly identified, equating to a sensitivity and specificity of 97% (95% CI 84-100%) and 83% (95% CI 51-97%), respectively. All lesions of 20- and 40-HU enhancement and 92% of 10-HU lesions were identified correctly. In a phantom model, the DECT iodine overlay technique is highly sensitive in detecting enhancing renal masses. Refinement of the technique remains necessary to improve specificity. If validated in patients, this may obviate the need for unenhanced acquisitions for renal mass characterization.


Asunto(s)
Yodo , Riñón/patología , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Simulación por Computador , Medios de Contraste/farmacología , Humanos , Procesamiento de Imagen Asistido por Computador , Variaciones Dependientes del Observador , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Sensibilidad y Especificidad , Programas Informáticos , Tomografía Computarizada por Rayos X/instrumentación
20.
Abdom Imaging ; 34(3): 283-8, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-18551337

RESUMEN

CT enterography has rapidly gained acceptance as a method for visualizing the small bowel lumen, wall and mesentery for a variety of clinical indications. Focusing on the identification of Crohn's disease, and vascular and neoplastic small bowel masses, this review summarizes oral contrast agents and CT acquisition techniques used for CT enterography, alternatives that can be used to tailor the exam for specific indications, and how such variations affect the appearance of a variety of pathologies at CT imaging.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Neoplasias Intestinales/diagnóstico por imagen , Intestino Delgado/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Humanos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/tendencias
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA