Resuscitation ; 116: 66-72, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28427883

RESUMEN

AIMS: Effective ventilation is crucial to save non-breathing newborns. We compared standard equipment for newborn resuscitation to a new Upright bag, in an area with high neonatal mortality. METHODS: Newborns requiring resuscitation at Haydom Lutheran Hospital, Tanzania, were ventilated with 230ml standard or 320ml Upright bag-mask by weekly non-blinded block randomisation. A Laerdal Newborn Resuscitation Monitor collected ventilation data through a flow sensor between mask and bag and heart rate with electrocardiography electrodes. Primary outcome was expiratory tidal volume per birth weight. RESULTS: Of 6110 babies born, 136 randomised to standard bag-mask and 192 to Upright, both groups had similar birth weight, gestational age, Apgar scores, gender, and mode of delivery. Compared to standard bag-mask, Upright gave higher median expiratory tidal volume (8.6ml/kg (IQR: 3.5-13.8) vs. 10.0ml/kg (IQR: 4.3-16.8) difference ratio 1.29, 95%CI 1.05, 1.58, p=0.014)), increased mean airway and peak inspiratory pressures, and higher early expired CO2 (median at 20s 4.2% vs. 3.2%, p=0.0099). Clinical outcome 30min post-delivery was normal in 44% with standard versus 57% with Upright (p=0.016), but similar at 24h. CONCLUSION AND RELEVANCE: Upright provided higher expired tidal volume, MAP, PIP and early ECO2 than the standard bag. Clinical outcome differed at 30min, but not at 24h. Larger volume of Upright than standard bag can be an important factor. The results are relevant for low- and high-income settings as ventilatory and heart rate parameters during resuscitation of newborns are rarely reported. Trial registered at www.ClinicalTrials.gov, NCT01869582.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Insuflación/instrumentación , Respiración Artificial/instrumentación , Femenino , Edad Gestacional , Humanos , Recién Nacido , Máscaras Laríngeas , Masculino , Pobreza , Tanzanía , Volumen de Ventilación Pulmonar/fisiología
2.
Neonatology ; 110(3): 231-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27250761

RESUMEN

BACKGROUND: There is limited evidence regarding the heart rate (HR) during the first minutes of life. Nonetheless, resuscitative actions within the first minute are partly guided by different HR levels. The advent of an electrocardiographic (ECG) HR sensor with early HR detection has provided the opportunity to study changes immediately following delivery. OBJECTIVE: The objectives were to determine immediately following delivery: (i) the time to achievement of reliable ECG signals using dry electrodes, (ii) changes in HR, and (iii) the influence of the onset of breathing and cord clamping on the HR. METHODS: Healthy term neonates were randomly included between July and October 2013. The HR was recorded by the ECG sensor, placed over the abdomen immediately after birth. RESULTS: Fifty-five newborns were included. The median time from birth to placement of the HR sensor was 3 s (quartiles: 2 and 5), and the median time to the start of breathing was 6 s (quartiles: 2 and 15). The HR was around 120 beats/min (bpm) in the first seconds of life. As determined via breakpoint analysis, the HR increased by 1 beat in the first 40 s to 149 ± 33 bpm, followed by a moderate increase until 130 s and stabilization thereafter. After the onset of breathing, the HR decreased for 10 s and then increased. Minimal HR changes were observed after cord clamping. CONCLUSION: A dry-electrode ECG sensor detected reliable ECG signals almost immediately after birth. The normal HR increased significantly in spontaneously breathing infants during the first minute, influenced by the onset of breathing. Delayed cord clamping had a minimal impact on the HR, likely reflecting an earlier onset of breathing.


Asunto(s)
Frecuencia Cardíaca , Respiración , Constricción , Electrocardiografía , Electrodos , Femenino , Voluntarios Sanos , Humanos , Recién Nacido , Masculino , Valores de Referencia , Análisis de Regresión , Tanzanía , Nacimiento a Término , Factores de Tiempo