Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Int Cancer Conf J ; 13(2): 111-118, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38524641

RESUMEN

Dermatomyositis (DM) is an autoimmune disease that causes proximal muscle weakness in the extremities leading to severe immobility and dysphagia. Approximately 20% of patients with DM are positive for anti-TIF-1γ antibody and frequently accompanied by malignant tumors. Although DM remission after tumor resection has been reported, the indications for surgery in patients with severe DM are unknown. Herein, we report a case of a 79-year-old Japanese woman who presented with breast cancer and anti-TIF-1γ antibody-positive DM. She became bedridden shortly after DM onset. Although pulsed steroid therapy, intravenous immunoglobulin, tacrolimus, and endocrine therapy with fulvestrant did not improve her symptoms, tumor resection with axillary lymph node dissection resulted in complete remission of the DM after 8 months. Immunohistochemistry revealed high expression of TIF-1γ in cancer cells, both in the primary tumor and axillary lymph nodes. Since the serum levels of anti-TIF-1γ antibody decreased after the surgery, the existence of breast cancer with TIF-1γ expression may have contributed to the worsening of DM. The present case suggests that curative surgery should be considered as a treatment option even if the patient has severe symptoms, such as immobility and dysphagia. Careful discussions with patients and multidisciplinary collaboration are essential to make surgery feasible, particularly for those with severe symptomatic DM.

2.
Front Oncol ; 11: 674419, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34123842

RESUMEN

BACKGROUND: The Medical Imaging Projection System (MIPS) projects indocyanine green (ICG) fluorescence images directly on the surgical field using a projection mapping technique. We conducted an observational study of sentinel lymph node (SLN) biopsy using the prototype MIPS; we found a high identification rate. However, the number of SLN-positive cases was small, and the sensitivity could not be evaluated. The aim of this study was to investigate the clinical usefulness of the MIPS assisted ICG fluorescence method using commercially available equipment. METHODS: This was a retrospective observational study. Patients with primary breast cancer who underwent SLN biopsy using the MIPS at Kyoto University Hospital from April to December 2020 were included in the study. The primary endpoints were the identification rate of SLNs and detection of positive SLNs by the MIPS. The secondary endpoint was the number of SLNs excised using the MIPS per patient. We also conducted a questionnaire survey focused on the utility of the MIPS; it involved doctors with an experience in using the MIPS. RESULTS: Seventy-nine patients (84 procedures) were included in the study. In 60 (71%) procedures, both the radioisotope (RI) method and MIPS were used. At least one SLN could be detected by the MIPS in all the procedures, with an identification rate of 100% (95% confidence interval 95.6-100%). A total of 19 (7%) positive SLNs were removed, which were identifiable by the MIPS. Among 57 patients in whom the MIPS and RI methods were used, there was no positive SLN only identified by the RI method. The results of the questionnaire survey showed that the MIPS enabled the operator and assistant to share the ICG fluorescence image in the surgical field and to communicate with each other easily. CONCLUSION: The current study demonstrated that the identification rate of SLNs using the MIPS was high, and the MIPS can be used for detecting positive SLNs. It was suggested that the MIPS will be useful in learning SLN biopsy procedures.

3.
Opt Express ; 20(4): 4753-62, 2012 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-22418232

RESUMEN

We studied the spectral linewidth narrowing of wavelength-swept actively mode-locked ring lasers (AMLLs). The numerical calculations for the static-state AMLL led us to predict that anomalous dispersion would narrows the linewidth. We examined the effect experimentally using AMLL setups for normal and anomalous dispersive cavities via the normal or inverse use of a linearly chirped fiber Bragg grating. The experiment indicated that the cavity with anomalous dispersion always generates narrower linewidth lasers than its normal dispersion equivalent. The cavity with anomalous dispersion also achieved a 0.08 nm linewidth. Using the anomalous dispersion setup, we observed instantaneous linewidth broadening during wavelength sweeping. Although the coherence of AMLL decreased drastically when the sweep rate became very rapid beyond a single roundtrip, narrow-linewidth lasing was observed within a single roundtrip. In summary, we demonstrated the use of 150 kHz wavelength sweeping with a 40-nm range and a 2.7-m short-length anomalous dispersion cavity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA