Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
Más filtros

País/Región como asunto
País de afiliación
Intervalo de año de publicación
1.
Ulus Travma Acil Cerrahi Derg ; 30(7): 518-524, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38967531

RESUMEN

BACKGROUND: Open reduction and internal fixation (ORIF) using locking plates is a widely adopted treatment for displaced proximal humerus fractures. Various augmentation techniques have been developed to enhance the stability of plate fixation. Among these, iliac bone autograft is notable for its advantages over allografts, such as ready availability and the elimination of costs and risks associated with disease transmission. Despite its potential benefits, data on the outcomes of iliac bone autograft augmentation (IBAA) are still limited. This study aims to present the mid- to long-term results of treating proximal humerus fractures with ORIF using locking plates and IBAA. METHODS: The study included 15 patients treated with ORIF and IBAA. We classified fracture patterns using the Neer classification and estimated local bone density via the deltoid tuberosity index. We measured the neck shaft angle (NSA) and humeral head height (HHH) on both immediate postoperative and most recent X-ray images to assess the maintenance of reduction. Clinical outcomes were evaluated using the DASH (Disabilities of the Arm, Shoulder, and Hand) and Constant scores. RESULTS: The average follow-up duration was 59.56 months, ranging from 24 to 93 months. A majority of fractures were classified as four-part (53%). The average immediate and late postoperative NSAs were 132.6±8.19 and 131.6±7.32 degrees, respectively. The average HHH on the immediate postoperative and latest follow-up images were 16.46±6.07 and 15.10±5.34, respectively. None of the patients exhibited any radiological signs of avascular necrosis or loss of reduction at the latest follow-up. The mean postoperative Constant and DASH scores at the latest follow-up were 79.6 and 11.5, respectively. CONCLUSION: Our findings suggest that ORIF with IBAA is an effective method for managing three- or four-part proximal humerus fractures, yielding excellent outcomes.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Ilion , Reducción Abierta , Fracturas del Hombro , Humanos , Fracturas del Hombro/cirugía , Masculino , Femenino , Persona de Mediana Edad , Ilion/trasplante , Fijación Interna de Fracturas/métodos , Reducción Abierta/métodos , Adulto , Resultado del Tratamiento , Anciano , Trasplante Óseo/métodos , Autoinjertos , Trasplante Autólogo/métodos , Estudios Retrospectivos
2.
Int J Prosthodont ; 37(7): 175-185, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38787582

RESUMEN

PURPOSE: To assess the manufacturing accuracy, intaglio surface adaptation, and survival of resin-based CAD/CAM definitive crowns created via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: A maxillary right first molar crown was digitally designed and manufactured using AM hybrid resin composite (VarseoSmile Crown Plus, Bego [AM-HRC]), AM glass filler-reinforced resin composite (Crowntec, Saremco Dental [AM-RC]), and SM polymer-infiltrated ceramic (Vita Enamic, VITA Zahnfabrik [SM-PICN]). Manufacturing accuracy (trueness and precision) was assessed by computing the root mean square (RMS) error (in µm; n = 15 per material). Intaglio surface adaptation was assessed by calculating the average gap distance (µm). Ten crowns from each group were cemented on fiberglass-reinforced epoxy resin dies and cyclically loaded to simulate 5 years of functional loading. One-way ANOVA, post hoc Bonferroni comparison tests, and Levene's test were used to analyze the data (α = .05). RESULTS: AM-RC had higher overall trueness than AM-HRC and SM-PICN (P ≤ .05), whereas the trueness of AM-RC on the external surface was similar to that of SM-PICN (P = .99) and higher than AM-HRC (P = .001). SM-PICN had lower precision than AM-RC and AM-HRC overall and at internal occlusal surfaces (P ≤ .05). Overall intaglio surface adaptation was similar between all groups (P = .531). However, for the axial intaglio surface, AM-RC and AM-HRC had higher adaptation than SM-PICN (P ≤ .05). All tested crowns survived the cyclic loading simulation of 5 years clinical use. CONCLUSIONS: AM-RC showed high manufacturing accuracy and adaptation. The tested resin-based CAD/CAM materials demonstrated clinically acceptable manufacturing accuracy and simulated medium-term durability, justifying the initiation of clinical investigations to determine their potential implementation in daily clinical practice.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Coronas , Diseño de Prótesis Dental , Técnicas In Vitro , Resinas Compuestas/química , Humanos , Adaptación Marginal Dental , Propiedades de Superficie , Ensayo de Materiales , Análisis del Estrés Dental , Cerámica/química , Diente Molar
3.
J Prosthet Dent ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38760311

RESUMEN

STATEMENT OF PROBLEM: Cantilevered complete arch implant-supported prostheses are commonly fabricated from zirconia and more recently from strength gradient zirconia. Different polymer-based materials indicated for definitive fixed prostheses that could be used with additive or subtractive manufacturing have also been marketed recently. However, knowledge on the long-term fatigue behavior of cantilevered implant-supported prostheses made from these polymer-based materials and strength gradient zirconia is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the fatigue behavior of implant-supported cantilevered prostheses of recently introduced computer-aided design and computer-aided manufacturing polymers and zirconia. MATERIAL AND METHODS: A master standard tessellation language file of a 9×11×20-mm specimen with a titanium base (Ti-base) space that represented an implant-supported cantilevered prosthesis was used to fabricate specimens from additively manufactured interim resin (AM), polymethyl methacrylate (SM-PM), nanographene-reinforced polymethyl methacrylate (SM-GR), high-impact polymer composite resin (SM-CR), and strength gradient zirconia (SM-ZR) (n=10). Each specimen was prepared by following the respective manufacturer's recommendations, and Ti-base abutments were cemented with an autopolymerizing luting composite resin. After cementation, the specimens were mounted in a mastication simulator and subjected to 1.2 million loading cycles under 100 N at 1.5 Hz; surviving specimens were subjected to another 1.2 million loading cycles under 200 N at 1.5 Hz. The load was applied to the cantilever extension, 12-mm from the clamp of the mastication simulator. The Kaplan-Meier survival analysis and Cox proportional hazards model were used to evaluate the data (α=.05). RESULTS: Significant differences in survival rate and hazard ratio were observed among materials (P<.001). Among tested materials, SM-ZR had the highest and AM had the lowest survival rate (P≤.031). All materials had a significantly higher hazard ratio than SM-ZR (P≤.011) in the increasing order of SM-GR, SM-PM, SM-CR, and AM. CONCLUSIONS: SM-ZR had the highest survival rate with no failed specimens. Even though most of the tested polymer-based materials failed during cyclic loading, these failures were commonly observed during the second 1.2 million loading cycles with 200 N. All materials had a higher hazard ratio than SM-ZR.

4.
J Adv Prosthodont ; 16(1): 48-56, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38455678

RESUMEN

PURPOSE: To evaluate the metameric disparities among monolithic zirconia materials with differing yttrium compositions across various lighting conditions. MATERIALS AND METHODS: Thirty-six square-shaped zirconia samples measuring 10 × 10 × 0.5 mm were prepared from monolithic zirconia materials with three different yttrium contents. A 0.2 mm thick layer of polymerized dual-polymerizable self-adhesive resin cement was created using a silicone mold with the same dimensions as the prepared zirconia specimens. To evaluate metamerism, color measurements were conducted using a spectrophotometer device on a neutral gray background in a color measurement cabinet that offers four different illumination environments. All samples underwent aging by subjecting them to 10000 thermal cycles using a thermal cycle tester. Following thermal aging, color measurements were taken once more, and the data were recorded using the CIE L*, a*, b* color system. Two-way ANOVA and Post-hoc Bonferroni tests were employed to analyze the data. RESULTS: It was observed that there was no statistical difference among the color measurements made in different illumination environments of the monolithic zirconia ceramics used to evaluate metamerism (P > .05). This observation remained consistent both before and after thermal aging. After thermal aging, the color of monolithic zirconia materials exhibited a tendency towards red and yellow hues, accompanied by a decrease in brightness levels. CONCLUSION: It can be stated that different illumination conditions did not affect the metamerism of monolithic zirconia materials, but there was a color change in monolithic zirconia materials after a thermal aging period equivalent to one year.

5.
Int J Prosthodont ; 37(7): 119-126, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38498863

RESUMEN

PURPOSE: To evaluate the effect of model resin type and time interval on the dimensional stability of additively manufactured diagnostic casts. MATERIALS AND METHODS: Ten irreversible hydrocolloid impressions and 10 impressions from an intraoral scanner were made from a reference maxillary stone cast, which was also digitized with a laboratory scanner. Conventional impressions were poured in type III stone (SC), while digital impressions were used to additively manufacture casts with a nanographene-reinforced model resin (GP) or a model resin (DM). All casts were digitized with the same laboratory scanner 1 day (T0), 1 week (T1), 2 weeks (T2), 3 weeks (T3), and 4 weeks (T4) after fabrication. Cast scans were superimposed over the reference cast scan to evaluate dimensional stability. Data were analyzed with Bonferroni-corrected repeated measures ANOVA (α = .05). RESULTS: The interaction between the main factors (material type and time interval) affected anterior teeth deviations, while the individual main factors affected anterior teeth and entire-cast deviations (P ≤ .008). Within anterior teeth, DM had the lowest deviations at T3, and GP mostly had lower values at T2 and lower deviations at T3 than at T0 (P ≤ .041). SC had the highest pooled anterior teeth deviations, and GP had the highest pooled entire cast deviations (P < .001). T3 had lower pooled anterior teeth deviations than at T0, T1, and T4, and higher pooled entire cast deviations than T1 were demonstrated (P ≤ .027). CONCLUSIONS: The trueness of nanographene-reinforced casts was either similar to or higher than that of other casts. Dimensional changes were acceptable during the course of 1 month.


Asunto(s)
Diseño Asistido por Computadora , Técnica de Impresión Dental , Maxilar , Imagenología Tridimensional
6.
Int J Prosthodont ; 37(7): 133-141, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38498865

RESUMEN

PURPOSE: To evaluate the flexural strength (FS) and microhardness of various CAD/CAM restorative materials intended for definitive use. The effect of hydrothermal aging on the mechanical properties of these materials was also investigated. MATERIALS AND METHODS: A total of 210 bar-shaped specimens (17 × 4 × 1.5 mm ± 0.02 mm) were fabricated via either subtractive manufacturing (SM) methods-reinforced composite resin (SM-CR), polymer-infiltrated ceramic network (SM-PICN), fine-structured feldspathic ceramic (SMFC), nanographene-reinforced polymethyl methacrylate (PMMA; SM-GPMMA), PMMAbased resin (SM-PMMA)-or additive manufacturing (AM) methods with urethane acrylate-based resins (AM-UA1 and AM-UA2). Specimens were then divided into two subgroups (nonaged or hydrothermal aging; n = 15). A three-point flexural strength test was performed, and five specimens from the nonaged group were submitted to microhardness testing. Specimens were subjected to 10,000 thermal cycles, and the measurements were repeated. RESULTS: Regardless of aging, SM-CR had the highest FS (P < .001), followed by SM-GPMMA (P ≤ .042). In nonaged groups, AM-UA2 had a lower FS than all other materials except SM-FC (P = 1.000). In hydrothermal aging groups, AM specimens had lower FS values than other materials, except SM-PMMA. With regard to microhardness, there was no significant difference found between any of the tested materials (P ≥ .945) in the nonaged and hydrothermal aging groups. CONCLUSIONS: The effect of hydrothermal aging on FS varied depending on the type of restorative material. Regardless of aging condition, SM-CR showed the highest FS values, whereas SM-FC had the highest microhardness. Hydrothermal aging had no significant influence on the microhardness of the tested materials.


Asunto(s)
Resistencia Flexional , Polimetil Metacrilato , Materiales Dentales , Resinas Compuestas , Polímeros , Ensayo de Materiales , Propiedades de Superficie , Diseño Asistido por Computadora
7.
Anatol J Cardiol ; 28(3): 150-157, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38419512

RESUMEN

BACKGROUND: Hypertrophic cardiomyopathy (HCM) is a genetically inherited cardiac disorder with diverse clinical presentations. Adrenergic activity, primarily mediated through beta-adrenoceptors, plays a central role in the clinical course of HCM. Adrenergic stimulation increases cardiac contractility and heart rate through beta-1 adrenoceptor activation. Beta-blocker drugs are recommended as the primary treatment for symptomatic HCM patients to mitigate these effects. METHODS: This prospective study aimed to investigate the impact of common ADRB-1 gene polymorphisms, specifically serine-glycine at position 49 and arginine-glycine at position 389, on the clinical and structural aspects of HCM. Additionally, the study explored the association between these genetic variations and the response to beta-blocker therapy in HCM patients. RESULTS: A cohort of 147 HCM patients was enrolled, and comprehensive assessments were performed. The findings revealed that the Ser49Gly polymorphism significantly influenced ventricular ectopic beats, with beta-blocker therapy effectively reducing them in Ser49 homozygous patients. Moreover, natriuretic peptide levels decreased, particularly in Ser49 homozygotes, indicating improved cardiac function. Left ventricular outflow obstruction, a hallmark of HCM, was also reduced following beta-blocker treatment in all patient groups. In contrast, the Arg389Gly polymorphism did not significantly impact baseline parameters or beta-blocker response. CONCLUSION: These results emphasize the role of the Ser49Gly polymorphism in the ADRB-1 gene in shaping the clinical course and response to beta-blocker therapy in HCM patients. This insight may enable a more personalized approach to managing HCM by considering genetic factors in treatment decisions. Further research with larger populations and longer follow-up periods is needed to confirm and expand upon these findings.


Asunto(s)
Cardiomiopatía Hipertrófica , Polimorfismo Genético , Humanos , Estudios Prospectivos , Antagonistas Adrenérgicos beta/uso terapéutico , Cardiomiopatía Hipertrófica/tratamiento farmacológico , Cardiomiopatía Hipertrófica/genética , Receptores Adrenérgicos/genética , Progresión de la Enfermedad , Glicina/genética
8.
Mol Biol Rep ; 51(1): 144, 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38236479

RESUMEN

BACKGROUND: The role of DNA repair mechanisms is of significant importance in diseases characterized by elevated oxidative DNA damage, such as chronic kidney disease. It is imperative to thoroughly understand the functions of molecules associated with DNA repair mechanisms, not only for assessing susceptibility to diseases but also for monitoring disease progression. In this research, we investigated the APE1 and OGG1 gene expression levels, both of which are involved in the base excision repair (BER) mechanism in chronic hemodialysis patients with malignancy (HPM; n = 8) and without malignancy (HP; n = 36) in pre- and post-dialysis period and 37 healty persons. We also assessed how these values correlate with the clinical profiles of the patients. METHODS AND RESULTS: We conducted gene expression analysis using real-time polymerase chain reaction (qRT-PCR). No significant differences in APE1 gene expression levels were observed in pre-dialysis when comparing the HP and HPM groups to the control group. The expression levels of the OGG1 gene were significantly lower in both the HP and HPM groups in pre- and post-dialysis periods compared to the control group. Dialysis procedures led to a reduction in APE1 and OGG1 gene expression levels in both HP and HPM groups. CONCLUSIONS: The findings of our study elucidate the impact of alterations in the base excision repair (BER) mechanism, including the hemodialysis process, in end-stage renal disease (ESRD).


Asunto(s)
ADN Glicosilasas , ADN-(Sitio Apurínico o Apirimidínico) Liasa , Fallo Renal Crónico , Neoplasias , Insuficiencia Renal Crónica , Humanos , Fallo Renal Crónico/genética , Fallo Renal Crónico/terapia , Diálisis Renal , ADN-(Sitio Apurínico o Apirimidínico) Liasa/genética , ADN Glicosilasas/genética
9.
Int J Prosthodont ; 37(7): 99-107, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37988421

RESUMEN

PURPOSE: To evaluate the fabrication trueness, intaglio surface adaptation, and marginal integrity of resin-based onlay restorations made via additive manufacturing (AM) or subtractive manufacturing (SM). MATERIALS AND METHODS: An onlay restoration was designed (DentalCAD Galway 3.0) and saved as an STL file to generate a design STL file (DO-STL). Using this design, 45 onlays were fabricated either with AM (3D-printed resin for definitive [AM-D; Tera Harz TC-80DP] and interim [AM-I; Freeprint temp] restorations) or SM (composite resin, Tetric CAD) technologies. Onlays were scanned with an intraoral scanner (CEREC Primescan SW 5.2), and the scans were saved as test STL files (TO-STLs). For trueness evaluation, TO-STLs were superimposed over the DO-STL, and root mean square (RMS) values of overall and intaglio surfaces were measured (Geomagic Control X). For the intaglio surface adaptation and marginal integrity, a triple-scan protocol was performed. Kolmogorov-Smirnov, one-way ANOVA, and post-hoc Tukey honestly significant difference tests were used to analyze data (α = .05). RESULTS: RMS values of intaglio and overall surfaces, intaglio adaptation, and marginal integrity varied among test groups (P < .001). AM-D had the greatest overall surface RMS (P < .001), while SM had the greatest intaglio surface RMS (P < .001). SM had the highest average distance deviations for intaglio surface adaptation and marginal integrity, whereas AM-D had the lowest (P < .001). CONCLUSIONS: AM-D onlays showed lower overall trueness than AM-I onlays and SM definitive onlays. However, AM-D onlays presented high intaglio surface trueness, intaglio surface adaptation, and marginal integrity.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Prótesis Dental , Humanos , Diseño de Prótesis Dental/métodos , Adaptación Marginal Dental , Incrustaciones , Atención Odontológica
10.
Jt Dis Relat Surg ; 35(1): 62-71, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38108167

RESUMEN

OBJECTIVES: This study aims to investigate the reliability of acromiohumeral distance (AHD) measurements using conventional radiographs and to compare non-standardized and standardized radiographs with intra-/interobserver reliability measurements. PATIENTS AND METHODS: Between February 2021 and January 2022, a total of 110 shoulders of 55 patients (25 males, 30 females; mean age: 49.7±12.6 years; range, 25 to 77 years) were included. Radiographs were taken in four different positions: primarily shoulder anteroposterior (AP), true AP, standardized true AP, and standardized outlet views. The AHD was measured by three orthopedists. A prospective ultrasonography (US) evaluation was performed by an experienced physiatrist, and the relationship between US and radiographic measurements was evaluated. The intra- and interobserver reliability of radiographic measurements was assessed. RESULTS: On the standardized true AP view measurements, all observers showed a moderate to good agreement with US measurements (intraclass correlation coefficients [ICC]: 0.68-0.75). There was no significant difference between the AHD measurements of the senior orthopedist on standardized true AP and outlet views, and the US measurements. The intraobserver agreement of US measurements was excellent (ICC: 0.98, 95% confidence interval [CI]: 0.98-0.99), and the intraobserver agreement level of measurements on radiographs were good to excellent with a wide range of ICC values (ICC: 0.79-0.97). Interobserver reliability was the highest on the standardized outlet view, with an ICC of 0.91 and 0.88 in two measurement times. Interobserver reliability of other measurements were good with ICC values ranging from 0.82 to 0.88. CONCLUSION: The AHD measurements on radiographs are compatible with US measurements within up to 2 mm difference if standardization is ensured. Also, measurements on standardized views have a superior consistency with lower standard error of measurement and minimal detectable change values. Therefore, we recommend using standardized true shoulder AP and standardized outlet radiographs in clinical practice and studies, as these are the most accurate in demonstrating true AHD.


Asunto(s)
Estudios Prospectivos , Masculino , Femenino , Humanos , Adulto , Persona de Mediana Edad , Reproducibilidad de los Resultados , Variaciones Dependientes del Observador , Radiografía , Ultrasonografía
11.
Cureus ; 15(9): e45477, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37859898

RESUMEN

In this case report, we want to show how a patient who underwent surgery for a distal humerus fracture developed postoperative ulnar neuropathy symptoms, how nonunion persisted even at the ninth month of follow-up, and whether the nonunion was connected to the ulnar neuropathy that developed. Due to this, we used this case to explore ulnar nerve care and whether ulnar nerve transposition, manipulation, or decompression should be carried out during surgery on patients with distal humerus fractures. A 52-year-old man with a bi-columnar distal humerus fracture from a fall on his right elbow underwent open reduction and internal fixation at an external center one year before. Elbow restriction, discomfort, numbness, and weakness in the fourth and fifth digits of the right hand were all symptoms the patient experienced eight months following the surgery. We discovered the distal right humerus' nonunion during the radiological exams. It became apparent that the patient had no signs of ulnar neuropathy before the injury. In the eighth month following the injury, the patient had implant removal, open reduction internal fixation with autograft, and ulnar nerve transposition. We discovered during follow-up that the patient's ulnar neuropathy symptoms had subsided. The surgeon's familiarity with the procedure and command of the anatomy of the elbow has a role in managing the ulnar nerve in distal humerus fractures. We concluded that more study is required to determine the connection between the onset of ulnar neuropathy and nonunion while treating distal humerus fractures.

12.
J Dent ; 139: 104716, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37739057

RESUMEN

OBJECTIVES: To evaluate the accuracy of the scans of the combined healing abutment-scan body (CHA-SB) system located at different sites of the maxilla when SBs are replaced in between each scan. METHODS: Three SBs were seated into HAs located at the central incisor, first premolar, and first molar sites of a maxillary model inside a phantom head, and the model was scanned extraorally (CEREC Primescan SW 5.2). This procedure was repeated with new SBs until a total of 10 scans were performed. Standard tessellation language files of CHA-SBs at each implant location were isolated, transferred into analysis software (Geomagic Control X), and superimposed over the proprietary library files to analyze surface (root mean square), linear, and angular deviations. Trueness and precision were evaluated with one-way analysis of variance and Tukey tests. The correlation between surface and angular deviations was analyzed with Pearson's correlation (α=0.05). RESULTS: Molar implant scans had the highest surface and angular deviations (P≤.006), while central incisor implant scans had higher precision (surface deviations) than premolar implant scans (P=.041). Premolar implant scans had higher accuracy than central incisor implant scans on the y-axis (P≤.029). Central incisor implant scans had the highest accuracy on the z-axis (P≤.018). A strong positive correlation was observed between surface and angular deviations (r = 0.864, P<.001). CONCLUSION: Central incisor implant scans mostly had high accuracy and molar implant scans mostly had lower trueness. SBs were mostly positioned apically; however, the effect of SB replacement can be considered small as measured deviations were similar to those in previous studies and the precision of scans was high. CLINICAL SIGNIFICANCE: Repositioning of scan bodies into healing abutments would be expected to result in similar single crown positioning regardless of the location of the implant, considering high scan precision with the healing abutment-scan body system. The duration of the chairside adjustments of crowns in the posterior maxilla may be longer than those in the anterior region.


Asunto(s)
Implantes Dentales , Reposicionamiento de Medicamentos , Maxilar/diagnóstico por imagen , Técnica de Impresión Dental , Diseño Asistido por Computadora , Modelos Dentales , Imagenología Tridimensional
13.
Clin Oral Implants Res ; 34(11): 1248-1256, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37578653

RESUMEN

OBJECTIVES: To investigate the effect of implant-abutment connection and screw channel angle on screw stability by comparing a newly introduced and an established connection, before and after cyclic loading. MATERIALS AND METHODS: Implants (N = 44) with Torcfit (TF) or Crossfit (CF) connection were divided to be restored with a straight (CFS and TFS) or an angled screw access channel (CFA and TFA) titanium-base abutment (n = 11). CFA and TFA received screw-retained crowns, whereas CFS and TFS received hybrid zirconia abutments and cement-retained crowns. The initial torque value (ITV) of each complex (ITVI ) and removal torque value (RTV) after 24 h (RTVI ) were measured. Screws were replaced with new ones, ITVs were recorded again (ITVF ), and crowns were cyclically loaded (2.4 million cycles, 98 N) to measure RTVs again (RTVF ). Percentage torque loss was calculated. Data were analyzed (α = 0.05). RESULTS: ITVs were similar among groups (p ≥ .089). CF led to higher RTVs (p ≤ .002), while CFS had higher RTVI than CFA (p = .023). After 24 h, CFS had lower percentage torque loss than TF, while CFA had lower percentage torque loss than TFA (p ≤ .011). After cyclic loading, CF led to lower percentage torque (p < .001). CONCLUSION: The implant-abutment connection affected the removal torque values. However, no screw loosening occurred during cyclic loading, which indicated a stable connection for all groups. Screw access channel angle did not affect screw stability after cyclic loading.


Asunto(s)
Cementos Dentales , Implantes Dentales , Análisis del Estrés Dental , Coronas , Tornillos Óseos , Torque , Titanio , Pilares Dentales , Diseño de Implante Dental-Pilar , Ensayo de Materiales
14.
Endocrine ; 82(3): 586-589, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37428297

RESUMEN

PURPOSE: This study aimed to investigate whether 25 µg/day dose of triiodothyronine (T3) can also suppress thyroid stimulating hormone (TSH) level, as well as the routine dose of 50-100 µg/day in T3 suppression test, which is used to the distinguish between resistance to thyroid hormone (RTH) and TSH secreting pituitary adenoma. METHODS: In this prospective study, 26 patients with genetically proven RTH were randomly divided into two groups: Group 1 comprised 13 patients who were administered 50-100 µg/day T3 for 3-9 days, while Group 2 also comprised 13 patients who were administered 25 µg/day T3 for 7 days for T3 suppression test. The two groups' responses to T3 suppression tests were compared. RESULTS: The comparison of the mean percentage changes in TSH values by the T3 suppression tests showed no significant differences between the groups, and a ≥80% decrease was detected in all patients. Nine patients in Group 1 and one patient in Group 2 reported that they had to use propranolol due to tachycardia developed during the test. CONCLUSION: As higher doses of T3 can increase the risk of severe tachycardia during T3 suppression test, a low dose with 25 mcg/day for a week appears to be safer and more useful.


Asunto(s)
Síndrome de Resistencia a Hormonas Tiroideas , Tirotropina , Humanos , Estudios Prospectivos , Triyodotironina , Taquicardia , Tiroxina
15.
Cardiovasc Toxicol ; 23(7-8): 278-283, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37458898

RESUMEN

Ionizing radiation (IR) exposures have increased exponentially in recent years due to the rise in diagnostic and therapeutic interventions. A number of small-scale studies investigated the long-term effect of IR on health workers or immediate effects of IR on patients undergoing catheterization procedures; however, the long-term impact of multiple cardiac catheterizations on DNA damage on a patient population is not known. In this study, the effects of IR on DNA damage, based on micronuclei (MN) frequency and 8-hydroxy-2'-deoxyguanosine (8-OHdG) as markers in peripheral lymphocytes, were evaluated in patients who previously underwent multiple cardiac catheterization procedures. Moreover, genetic polymorphisms in genes PARP1 Val762Ala, OGG1 Ser326Cys, and APE1 Asn148Glu as a measure of sensitivity to radiation exposure were also investigated in the same patient population. The patients who underwent ≥ 3 cardiac catheterization procedures revealed higher DNA injury in comparison to the patients who underwent ≤ 2 procedures, documented with the presence of higher level of MN frequency (6.4 ± 4.8 vs. 9.1 ± 4.3, p = 0.002) and elevated serum 8-OHdG levels (33.7 ± 3.8 ng/mL vs. 17.4 ± 1.9 ng/mL, p = 0.001). Besides, OGG1 Ser326Cys and APE1 Asn148Glu heterozygous and homozygous polymorphic types, which are related with DNA repair mechanisms, were significantly associated with MN frequency levels (p = 0.006 for heterozygous and p = 0.001 for homozygous with respect to OGG1 Ser326Cys, p = 0.007 for heterozygous and p = 0.001 for homozygous with respect to APE1 Asn148Glu). There was no significant difference in terms of PARP1 Val762Ala gene polymorphism between two groups.


Asunto(s)
Daño del ADN , Reparación del ADN , Humanos , Polimorfismo Genético , 8-Hidroxi-2'-Desoxicoguanosina , Cateterismo Cardíaco/efectos adversos , Radiación Ionizante , Polimorfismo de Nucleótido Simple
16.
Mol Biol Rep ; 50(8): 6843-6850, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37392287

RESUMEN

BACKGROUND: The effective maintenance of genome integrity and fidelity is vital for the normal function of our tissues and organs, and the prevention of diseases. DNA repair pathways maintain genome stability, and the adequacy of genes acting in these pathways is essential for disease suppression and direct treatment responses. Chronic kidney disease is characterized by high levels of genomic damage. In this study, we examined the expression levels of the xeroderma pigmentosum group D (XPD) gene, which plays a role in the nucleotide excision repair (NER) repair mechanism, and the expression levels of miR-145 and miR-770 genes, which play a role in the regulation of the expression of the XPD gene, in hemodialysis patients with (n = 42) and without malignancy (n = 9) in pre- and post-dialysis conditions. We also evaluated these values with the clinical findings of the patients. METHODS & RESULTS: Gene expression analysis was performed by real-time polymerase chain reaction (qRT-PCR). Compared to the individuals with normal kidney function (2.06 ± 0.32), the XPD gene expression was lower in the pre-dialysis condition both in hemodialysis patients without cancer (1.24 ± 0.18; p = 0.02) and in hemodialysis patients with cancer (0.82 ± 0.114; p = 0.001). On the other hand, we found that miR-145 and miR-770 expression levels were high in both groups. We also found that expression levels were affected by dialysis processes. A statistically significant positive correlation was found between miR-145 and mir770 expression levels in the pre-dialysis group of patients with (r=-0.988. p = 0.0001) and without (r=-0.934. p = 0.0001) malignancy. CONCLUSIONS: Studies on DNA damage repair in the kidney will help develop strategies to protect kidney function against kidney diseases.


Asunto(s)
Fallo Renal Crónico , MicroARNs , Xerodermia Pigmentosa , Humanos , Xerodermia Pigmentosa/genética , Xerodermia Pigmentosa/metabolismo , Proteína de la Xerodermia Pigmentosa del Grupo D/genética , Proteína de la Xerodermia Pigmentosa del Grupo D/metabolismo , Reparación del ADN/genética , Fallo Renal Crónico/genética , Fallo Renal Crónico/terapia , MicroARNs/genética , Predisposición Genética a la Enfermedad
17.
J Int Adv Otol ; 19(3): 206-211, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37272637

RESUMEN

BACKGROUND: Postoperative adhesion is an important complication after middle-ear surgeries. Although many materials have been tried to prevent this complication, the use of Poly (dl-lactide ε-caprolactone) as an anti-adhesive material after middle-ear surgery has not yet been reported. The aim of this study was to evaluate the anti-adhesive effect of poly (dl-lactide ε-caprolactone) on the ears of rats with middle-ear mucosa damage. METHODS: In our study, 14 Wistar albino rats and 28 ears in total were used. The rats were randomly divided into 4 groups. Middle ear mucosa damage was performed in all groups with a transcanal approach under otomicroscopy in sterile conditions. The effects of poly (dl-lactide ε-caprolactone), silicone sheet, and absorbable gelatin sponge were compared histologically with the secondary healing group. In addition, hearing evaluation was performed before the procedure and on the 28th postoperative day. RESULTS: No significant difference was observed in transient otoacoustic emission and distortion product otoacoustic emissions tests performed before and after the surgical procedure when the groups were compared. While adhesion was observed in the tympanic membrane in the absorbable gelatin sponge group, no adhesion was observed in the other groups. In the absorbable gelatin sponge group, increased fibroblastic activity, inflammation, and neovascularization were observed in the middle-ear mucosa. No significant difference was observed in silicone sheet, poly (dl-lactide ε-caprolactone), and control groups in terms of fibroblastic activity, inflammation, and neovascularization. CONCLUSION: It can be concluded that absorbable poly (dl-lactide ε-caprolactone) is nonototoxic and biocompatible with the rat's middle ear cavity by short-term evaluation.


Asunto(s)
Implantes Absorbibles , Oído Medio , Animales , Ratas , Ratas Wistar , Oído Medio/cirugía , Oído Medio/patología , Siliconas , Inflamación/patología , Membrana Mucosa
18.
J Clin Endocrinol Metab ; 108(10): e1013-e1026, 2023 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-37186260

RESUMEN

CONTEXT: The aims of the study are to compare characteristics of subacute thyroiditis (SAT) related to different etiologies, and to identify predictors of recurrence of SAT and incident hypothyroidism. METHODS: This nationwide, multicenter, retrospective cohort study included 53 endocrinology centers in Turkey. The study participants were divided into either COVID-19-related SAT (Cov-SAT), SARS-CoV-2 vaccine-related SAT (Vac-SAT), or control SAT (Cont-SAT) groups. RESULTS: Of the 811 patients, 258 (31.8%) were included in the Vac-SAT group, 98 (12.1%) in the Cov-SAT group, and 455 (56.1%) in the Cont-SAT group. No difference was found between the groups with regard to laboratory and imaging findings. SAT etiology was not an independent predictor of recurrence or hypothyroidism. In the entire cohort, steroid therapy requirement and younger age were statistically significant predictors for SAT recurrence. C-reactive protein measured during SAT onset, female sex, absence of antithyroid peroxidase (TPO) positivity, and absence of steroid therapy were statistically significant predictors of incident (early) hypothyroidism, irrespective of SAT etiology. On the other hand, probable predictors of established hypothyroidism differed from that of incident hypothyroidism. CONCLUSION: Since there is no difference in terms of follow-up parameters and outcomes, COVID-19- and SARS-CoV-2 vaccine-related SAT can be treated and followed up like classic SATs. Recurrence was determined by younger age and steroid therapy requirement. Steroid therapy independently predicts incident hypothyroidism that may sometimes be transient in overall SAT and is also associated with a lower risk of established hypothyroidism.


Asunto(s)
COVID-19 , Hipotiroidismo , Tiroiditis Subaguda , Humanos , Femenino , Tiroiditis Subaguda/epidemiología , Tiroiditis Subaguda/etiología , COVID-19/complicaciones , COVID-19/epidemiología , COVID-19/prevención & control , Vacunas contra la COVID-19/efectos adversos , Estudios Retrospectivos , SARS-CoV-2 , Hipotiroidismo/etiología , Hipotiroidismo/complicaciones , Esteroides
19.
Mol Biol Rep ; 50(6): 5157-5163, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37119411

RESUMEN

BACKGROUND: The dysfunctions in the metabolism of iron have an important role in many pathological conditions, ranging from disease with iron deposition to cancer. Studies on malignant diseases of the breast reported irregular expression in genes associated with iron metabolism. The variations are related to findings that have prognostic significance. This study evaluated the relationship of the expression levels of transferrin receptor 1 (TFRC), iron regulatory protein 1 (IRP1), hepcidin (HAMP), ferroportin 1 (FPN1), hemojuvelin (HFE2), matriptase 2 (TMPRSS6), and miR-122 genes in the normal and malignant tissues of breast cancer patients. METHODS & RESULTS: The normal and malignant tissues from 75 women with breast malignancies were used in this study. The patients did not receive any treatment previously. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used in figuring the levels of gene expression associated with iron metabolism. When the malignant and normal tissues gene expression levels were analyzed, expression of TFRC increased (1.586-fold); IRP1 (0.594 fold) and miR-122 (0.320 fold) expression decreased; HAMP, FPN1, HFE2, and TMPRSS6 expressions did not change. FPN1 and IRP1 had a positive association, and this association was statistically significant (r = 0.266; p = 0.022). IRP1 and miR-122 had a positive association, and this association had statistical significance (r = 0.231; p = 0.048). CONCLUSIONS: Our study portrayed the important association between genes involved in iron hemostasis and breast malignancy. The results could be used to establish new diagnostic techniques in the management of breast malignancies. The alterations in the metabolism of malignant breast cells with normal breast cells could be utilized to achieve advantages in treatment.


Asunto(s)
Neoplasias de la Mama , MicroARNs , Humanos , Femenino , Neoplasias de la Mama/genética , Hierro/metabolismo , Homeostasis/genética , MicroARNs/genética
20.
Foot Ankle Surg ; 29(4): 329-333, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37062618

RESUMEN

PURPOSE: This study aimed to assess the impact of fixation on functional and radiological outcomes of ankle fractures involving the posterior malleolus. We hypothesized that fixation of the posterior malleolus would be associated with improved radiological and functional outcome. METHODS: A prospective randomized controlled study was planned and 40 consecutive ankle fractures involving middle-sized (10-25%) posterior fragment were included. Posterior fragments in Group 1 were not fixated while Group 2 underwent posterior malleolus fixation. The patients were evaluated both functionally and radiologically at minimum 2-years. RESULTS: Demographics and fracture type distributions were similar between the groups. Despite the slightly better functional outcome in Group 2, no significant functional or radiological outcome difference could be detected. Articular step-off> 1 mm was more common in Group 1 (p = 0.04) and the patients with articular step-off showed significantly worse functional outcome in all functional parameters (p < 0.05). Radiological and functional outcome parameters were positively correlated when all patients were evaluated together. Lateral radiographs caused an overestimation in the size of posterior fragment compared to CT (p < 0.001). CONCLUSION: Although there was a slightly better clinical outcome in patients with fixed posterior fragments, it was not significant at short to mid-term follow-up. However, posterior fragment fixation contributed to functional outcomes by decreasing the incidence of articular step-off> 1 mm, which was found to be a negative prognostic factor. LEVEL OF EVIDENCE: Level I; prospective randomized controlled study.


Asunto(s)
Fracturas de Tobillo , Humanos , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Estudios Prospectivos , Fijación Interna de Fracturas , Radiografía , Tibia , Resultado del Tratamiento , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA