Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Struct Biol ; 214(4): 107915, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36341955

RESUMEN

Single-Particle Analysis by Cryo-Electron Microscopy is a well-established technique to elucidate the three-dimensional (3D) structure of biological macromolecules. The orientation of the acquired projection images must be initially estimated without any reference to the final structure. In this step, algorithms may find a mirrored version of all the orientations resulting in a mirrored 3D map. It is as compatible with the acquired images as its unmirrored version from the image processing point of view, only that it is not biologically plausible. In this article, we introduce HaPi (Handedness Pipeline), the first method to automatically determine the hand of electron density maps of macromolecules solved by CryoEM. HaPi is built by training two 3D convolutional neural networks. The first determines α-helices in a map, and the second determines whether the α-helix is left-handed or right-handed. A consensus strategy defines the overall map hand. The pipeline is trained on simulated and experimental data. The handedness can be detected only for maps whose resolution is better than 5 Å. HaPi can identify the hand in 89% of new simulated maps correctly. Moreover, we evaluated all the maps deposited at the Electron Microscopy Data Bank and 11 structures uploaded with the incorrect hand were identified.


Asunto(s)
Microscopía por Crioelectrón
2.
Faraday Discuss ; 240(0): 210-227, 2022 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-35861059

RESUMEN

The number of maps deposited in public databases (Electron Microscopy Data Bank, EMDB) determined by cryo-electron microscopy has quickly grown in recent years. With this rapid growth, it is critical to guarantee their quality. So far, map validation has primarily focused on the agreement between maps and models. From the image processing perspective, the validation has been mostly restricted to using two half-maps and the measurement of their internal consistency. In this article, we suggest that map validation can be taken much further from the point of view of image processing if 2D classes, particles, angles, coordinates, defoci, and micrographs are also provided. We present a progressive validation scheme that qualifies a result validation status from 0 to 5 and offers three optional qualifiers (A, W, and O) that can be added. The simplest validation state is 0, while the most complete would be 5AWO. This scheme has been implemented in a website https://biocomp.cnb.csic.es/EMValidationService/ to which reconstructed maps and their ESI can be uploaded.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Microscopía por Crioelectrón/métodos , Microscopía Electrónica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA