Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 282
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J Case Rep ; 8(8): ytae261, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39113778

RESUMEN

Background: Limited data exist on strain changes after transcatheter aortic valve implantation (TAVI) in patients with aortic regurgitation (AR). Case summary: Three patients with AR undergoing TAVI showed an initial reduction in global longitudinal strain (GLS), followed by sustained GLS improvement within the first year. Discussion: Findings align with those of surgically treated patients with AR. There is a possible superiority of GLS to left ventricular end-diastolic diameter ratio in assessing patients with severe volume overload.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39066744

RESUMEN

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

3.
PLoS One ; 19(7): e0304813, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39038008

RESUMEN

A patient with a neuroendocrine tumor and history of coronary artery disease underwent PET with 68Ga-DOTATATE PET tracer for tumor visualization. Analysis of the scan showed uptake of 68Ga-DOTATATE in the left ventricle corresponding to previous myocardial infarct. 68Ga-DOTATATE binds by somatostatin receptors (SSTR) and it has been proposed that it may be useful for the detection of cardiac inflammatory lesions. We aimed to test whether SSTR could be upregulated in cardiac fibrotic scar. We analyzed SSTR in cardiac samples from patients with end-stage ischemic cardiomyopathy (ICM, n = 8) and control hearts (n = 5). In mature ICM tissue, SSTR1 and SSTR2 expression was unchanged and SSTR5 expression was significantly decreased in ICM samples vs. control. Immunohistochemistry showed increased SSTR1 and SSTR2 in ICM. Areas with SSTR1 or SSTR2 staining were often adjacent to fibrotic areas. The majority of SSTR1 and SSTR2 staining localized in cardiomyocytes in fibrotic scar-rich areas where CD68 macrophage staining was not present. SSTR are occasionally upregulated in cardiac fibrotic areas. When using 68Ga-DOTATATE PET tracer to detect cardiac sarcoidosis or atherosclerotic plaque, the possibility of tracer uptake in fibrotic areas should be considered.


Asunto(s)
Fibrosis , Miocardio , Compuestos Organometálicos , Receptores de Somatostatina , Humanos , Receptores de Somatostatina/metabolismo , Fibrosis/metabolismo , Miocardio/metabolismo , Miocardio/patología , Masculino , Persona de Mediana Edad , Femenino , Anciano , Tomografía de Emisión de Positrones
4.
Pathogens ; 13(7)2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-39057770

RESUMEN

Infective endocarditis (IE) is a microbial infection of the endocardial surface, most commonly affecting native and prosthetic valves of the heart. The epidemiology and etiology of the disease have evolved significantly over the last decades. With a growing elderly population, the incidence of degenerative valvopathies and the use of prosthetic heart valves have increased, becoming the most important predisposing risk factors. This change in the epidemiology has caused a shift in the underlying microbiology of the disease, with Staphylococci overtaking Streptococci as the main causative pathogens. Other rarer microbes, including Streptococcus agalactiae, Pseudomonas aeruginosa, Coxiella burnetti and Brucella, have also emerged or re-emerged. Valvular IE caused by these pathogens, especially Staphylococcus aureus, is often associated with a severe clinical course, leading to high rates of morbidity and mortality. Therefore, prompt diagnosis and management are crucial. Due to the high virulence of these pathogens and an increased incidence of antimicrobial resistances, surgical valve repair or replacement is often necessary. As the epidemiology and etiology of valvular IE continue to evolve, the diagnostic methods and therapies need to be progressively advanced to ensure satisfactory clinical outcomes.

5.
Ann Thorac Surg ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38936593

RESUMEN

BACKGROUND: Although adverse technical events during aortic root replacement (ARR) are not uncommon and are extremely challenging, there is scant literature to help surgeons prepare for such situations. We describe our experience of outstanding technical events during ARR. METHODS: This is a retrospective study of 830 consecutive ARRs at a single center from 2012 to 2022. Technical events were defined as intraoperative events that led to an unplanned cardiac procedure, need for mechanical circulatory support, or additional aortic cross-clamping. Logistic regression identified factors associated with operative mortality and technical events. RESULTS: Technical events occurred in 90 patients (10.8%) and were attributed to bleeding (n = 26), nonischemic ventricular dysfunction (n = 23), residual valve disease (n = 20), myocardial ischemia (n = 19), and iatrogenic dissection (n = 2). Prior sternotomy (odds ratio [OR], 2.38; 95% CI, 1.36-4.19; P = .002) and complex aortic valve disease (OR, 3.09; 95% CI, 1.09-8.75; P = .03) were associated with technical events. Patients with technical events had higher rates of operative mortality (6.7% vs 2.3%, P = .03) and all major postoperative complications. Surgical indications of dissection (OR, 13.57; 95% CI, 4.95-37.23; P < .001) and complex aortic valve disease (OR, 14.09; 95% CI, 3.67-54.02; P < .001) but not adverse technical events (OR, 2.42; 95% CI, 0.81-7.26; P = .11) were associated with operative mortality. CONCLUSIONS: Adverse technical events occurred in 10.8% of ARRs and were associated with reoperative sternotomies. Technical events are associated with increased postoperative complications.

6.
Ann Cardiothorac Surg ; 13(3): 306-307, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38841087
7.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38866455

RESUMEN

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Estimulación Cardíaca Artificial , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Factores de Riesgo , Anciano , Factores de Tiempo , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/etiología , Arritmias Cardíacas/mortalidad , Estados Unidos/epidemiología
8.
JACC Adv ; 3(5): 100912, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38939644

RESUMEN

The treatment of severe aortic stenosis (SAS) has evolved rapidly with the advent of minimally invasive structural heart interventions. Transcatheter aortic valve replacement has allowed patients to undergo definitive SAS treatment achieving faster recovery rates compared to valve surgery. Not infrequently, patients are admitted/diagnosed with SAS after a fall associated with a hip fracture (HFx). While urgent orthopedic surgery is key to reduce disability and mortality, untreated SAS increases the perioperative risk and precludes physical recovery. There is no consensus on what the best strategy is either hip correction under hemodynamic monitoring followed by valve replacement or preoperative balloon aortic valvuloplasty to allow HFx surgery followed by valve replacement. However, preoperative minimalist transcatheter aortic valve replacement may represent an attractive strategy for selected patients. We provide a management pathway that emphasizes an early multidisciplinary approach to optimize time for hip surgery to improve orthopedic and cardiovascular outcomes in patients presenting with HFx-SAS.

9.
JACC Adv ; 3(3): 100839, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938839

RESUMEN

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

10.
Am J Cardiol ; 223: 7-14, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-38788821

RESUMEN

The frequency and effectiveness of repeat mitral valve interventions (RMVI) after transcatheter edge-to-edge repair (TEER) for secondary mitral regurgitation (MR) are unknown. We aimed to examine the rate of and outcomes after RMVI after TEER in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial. Only 3.9% of COAPT trial patients required a repeat mitral valve intervention during 4-year follow-up which was successful in 90% of cases but was associated with an increased rate of heart failure (HF) hospitalizations (HFH). The COAPT trial randomized HF patients with severe secondary MR to TEER with the MitraClip device plus guideline-directed medical therapy (GDMT) versus GDMT alone. We evaluated the characteristics and outcomes of patients who had an RMVI during 4-year follow-up. A MitraClip implant was attempted in 293 patients randomized to TEER+GDMT, 10 of whom underwent an RMVI procedure (9 repeat TEER and 1 surgical mitral valve replacement) after 4 years of follow-up (cumulative incidence 3.90%, 95% confidence interval [CI] 2.08 to 7.08; median 182 days after the initial procedure). Patients with RMVI had larger mitral annular diameters, fewer clips implanted, and were more likely to have ≥3+MR at discharge compared with those without RMVI. Reasons for RMVI included failed index procedure because of difficult transseptal puncture (n = 2) or tamponade (n = 1); residual or recurrent severe MR after an initially successful procedure (n = 5); partial clip detachment (n = 1); and site-assessed mitral stenosis (n = 1). RMVI was successful in 8/10 (80%) patients. Patients who underwent RMVI had higher 4-year rates of HFH but similar mortality compared with those without RMVI. The annualized incidence rates of all HFH in patients who underwent RMVI were 234 events per 100 person-years (95% CI 139 to 395) pre-RMVI and 46 per 100 person-years (95% CI 25 to 86) post-RMVI as compared with 32 events per 100 patient-years (95% CI 28 to 36) in patients without RMVI. The rate ratio of HFH was reduced after RMVI in patients who underwent RMVI (0.20, 95% CI 0.09 to 0.45). In conclusion, the cumulative incidence of RMVI after 4 years was 3.9% in patients who underwent TEER for severe secondary MR in the COAPT trial. Patients who underwent RMVI were at increased risk of HFH which was reduced after the RMVI procedure. Clinical Trial Registration: Clinical Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL:https://clinicaltrials.gov/ct2/show/NCT01626079.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Masculino , Femenino , Anciano , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Estudios de Seguimiento , Resultado del Tratamiento , Anciano de 80 o más Años , Reoperación , Insuficiencia Cardíaca/terapia
12.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
14.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599690

RESUMEN

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodos
15.
Front Cardiovasc Med ; 11: 1381102, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38665234

RESUMEN

Aortic insufficiency (AI) is a valvular disease with increasing prevalence in older patients. The modern era provides numerous options for the management of AI which is explored here. Traditional interventions included aortic valve replacement with either mechanical or bioprosthetic aortic valves. While the former is known for its durability, it has grown out of favor due to the potential complications of anticoagulation. The preference for bioprosthetic valves is thus on the rise, especially with the advancements of transcatheter technology and the use of valve-in-valve therapy. Surgical options are also no longer limited to replacement but include complex techniques such as those required for aortic valve repair, Ozaki neocuspidization, Ross procedure and valve-sparring aortic root repair. Transcatheter options for the management of AI are not commercially available currently; however, preliminary data from ad-hoc trials, showed promising results and potential use of transcatheter technology in a variety of patients with pure AI.

16.
EuroIntervention ; 20(6): e376-e388, 2024 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-38506739

RESUMEN

BACKGROUND: There are limited data regarding treatment for failed balloon-expandable transcatheter heart valves (THVs) in redo-transcatheter aortic valve implantation (TAVI). AIMS: We aimed to assess THV performance, neoskirt height and expansion when performing redo-TAVI with the ACURATE platform inside a SAPIEN 3 (S3) compared to redo-TAVI with an S3 in an S3. METHODS: Redo-TAVI was performed on the bench using each available size of the S3, the ACURATE neo2 (ACn2) and the next-generation ACURATE Prime XL (AC XL) implanted at 2 different depths within 20 mm/23 mm/26 mm/29 mm S3s serving as the "failed" index THV. Hydrodynamic testing was performed to assess THV function. Multimodality assessment was performed using photography, X-ray, microcomputed tomography (micro-CT), and high-speed videos. RESULTS: The ACURATE in S3 combinations had favourable hydrodynamic performance compared to the S3 in S3 for all size combinations. In the 20 mm S3, redo-TAVI with the ACn2 had lower gradients compared to the S3 (mean gradient 16.3 mmHg for the ACn2 vs 24.7 mmHg for the 20 mm S3 in 20 mm S3). Pinwheeling was less marked for the ACURATE THVs than for the S3s. On micro-CT, the S3s used for redo-TAVI were underexpanded across all sizes. This was also observed for the ACURATE platform, but to a lesser extent. CONCLUSIONS: Redo-TAVI with an ACn2/AC XL within an S3 has favourable hydrodynamic performance and less pinwheeling compared to an S3 in S3. This comes at the price of a taller neoskirt.


Asunto(s)
Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Microtomografía por Rayos X , Catéteres , Válvulas Cardíacas
17.
J Thorac Dis ; 16(2): 1565-1575, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38505020

RESUMEN

The treatment of aortic and mitral valve disease requiring replacement has shifted to an increasing use of bioprosthetic heart valves. Due to their limited durability, there is a growing need for reintervention in the setting of failing bioprosthesis. Even though the gold standard for the treatment of failed bioprosthesis remains surgical repair or replacement, valve-in-valve (ViV) transcatheter aortic and mitral valve replacement have emerged as safe and effective alternatives for patients who are at high or prohibitive risk for surgery. Both procedures are associated with a substantial risk of postprocedural thromboembolic events and valvular thrombosis that is often higher than transcatheter replacement of native valves. With guidelines lacking specific protocols and a limited number of available studies, the optimal postprocedural antithrombotic therapy remains to be clarified. Multiple factors including valvular hemodynamics, the characteristics of the failing surgical valve, and the choice of the new transcatheter heart valve (THV) must be considered. Additionally, patients are often at an advanced age with multiple comorbidities and may require oral anticoagulation (OAC) due to other indications such as atrial fibrillation. Although the recommended antithrombotic strategy for native transcatheter aortic valve replacement (TAVR) is antiplatelet monotherapy with aspirin or a P2Y12 inhibitor in the absence of another anticoagulation indication, the use of oral anticoagulants including vitamin K antagonists (VKAs) and direct thrombin inhibitors has been shown to be effective in reducing valvular thrombosis and are commonly used after ViV procedures. Prospective studies investigating these results specifically for ViV transcatheter aortic and mitral valve replacement are needed to identify the optimal antithrombotic therapy.

18.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
19.
Ann Thorac Surg ; 117(6): 1164-1171, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38316377

RESUMEN

BACKGROUND: Our objective was to compare the impact of patient-prosthesis mismatch (PPM) for 2 years after surgical aortic valve replacement within the prospective, randomized Placement of Aortic Transcatheter Valves (PARTNER) trials. METHODS: Surgical aortic valve replacement patients from the PARTNER 1, 2, and 3 trials were included. PPM was classified as moderate (indexed effective orifice area ≤0.85 cm2/m2) or severe (indexed effective orifice area ≤0.65 cm2/m2). The primary endpoint was the composite of all-cause death and heart failure rehospitalization at 2 years. RESULTS: By the predicted PPM method (PPMP), 59.1% had no PPM, 38.8% moderate PPM, and 2.1% severe PPM; whereas by the measured PPM method (PPMM), 42.4% had no PPM, 36.0% moderate, and 21.6% severe. Patients with no PPMP (23.6%) had a lower rate of the primary endpoint compared with patients with moderate (28.2%, P = .03) or severe PPMP (38.8%, P = .02). Using the PPMM method, there was no difference between the no (17.7%) and moderate PPMM groups (21.1%) in the primary outcome (P = .16). However, those with no PPMM or moderate PPMM were improved compared with severe PPMM (27.4%, P < .001 and P = .02, respectively). CONCLUSIONS: Severe PPM analyzed by PPMP was only 2.1% for surgical aortic valve replacement patients. The PPMM method overestimated the incidence of severe PPM relative to PPMP, but was also associated with worse outcome. There was higher all-cause mortality in patients with severe PPM, thus surgical techniques to minimize PPM remain critical.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Humanos , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Diseño de Prótesis , Anciano de 80 o más Años , Resultado del Tratamiento , Ajuste de Prótesis
20.
Am J Med ; 137(4): 321-330.e7, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38190959

RESUMEN

PURPOSE: There are concerns that transcatheter or surgical aortic valve replacement (TAVR/SAVR) procedures are preferentially available to White patients. Our objective was to examine differences in utilization of aortic valve replacement and outcomes by race/ethnicity in the US for patients with aortic stenosis. METHODS: We performed a serial cross-sectional cohort study of 299,976 Medicare beneficiaries hospitalized with principal diagnosis of aortic stenosis between 2012 and 2019 stratified by self-reported race/ethnicity (Black, Hispanic, Asian, Native American, and White). Outcomes included aortic valve replacement rates within 6 months of index hospitalization and associated procedural outcomes, including 30-day readmission, 30-day and 1-year mortality. RESULTS: Within 6 months of an index admission for aortic stenosis, 86.8% (122,457 SAVR; 138,026 TAVR) patients underwent aortic valve replacement. Overall, compared with White people, Black (HR 0.87 [0.85-0.89]), Hispanic (0.92 [0.88-0.96]), and Asian (0.95 [0.91-0.99]) people were less likely to receive aortic valve replacement. Among patients who were admitted emergently/urgently, White patients (41.1%, 95% CI, 40.7-41.4) had a significantly higher aortic valve replacement rate compared with Black (29.6%, 95% CI, 28.3-30.9), Hispanic (36.6%, 95% CI, 34.0-39.3), and Asian patients (35.4%, 95% CI, 32.3-38.9). Aortic valve replacement rates increased annually for all race/ethnicities. There were no significant differences in 30-day or 1-year mortality by race/ethnicity. CONCLUSIONS: Aortic valve replacement rates within 6 months of aortic stenosis admission are lower for Black, Hispanic, and Asian people compared to White people. These race-related differences in aortic stenosis treatment reflect complex issues in diagnosis and management, warranting a comprehensive reassessment of the entire care spectrum for disadvantaged populations.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos/epidemiología , Válvula Aórtica/cirugía , Estudios Transversales , Medicare , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA