Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Heart Rhythm ; 20(12): 1606-1614, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37633429

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients with hypertrophic cardiomyopathy (HCM) and can be challenging to manage. Atrioventricular nodal (AVN) ablation may be an effective management strategy for AF in these patients. OBJECTIVE: The purpose of this study was to assess the efficacy of AVN ablation in HCM patients who have failed medical therapy and/or catheter ablation for AF. METHODS: A multicenter study with retrospective analysis of a prospectively collated HCM registry was performed. AVN ablation patients were identified. Baseline characteristics and device and procedural indications were collected. Symptoms defined by New York Heart Association and European Heart Rhythm Association classification and echocardiographic findings during follow-up were assessed. RESULTS: Fifty-nine patients were included in the study. Indications for AVN ablation were 6 (10.2%) inappropriate implantable cardioverter-defibrillator shock, 35 (59.3%) ineffective rate control, and 18 (30.5%) to regularize rhythm for symptom improvement. During post-AVN ablation follow-up of 79.4 ± 61.1 months, left ventricular ejection fraction (LVEF) remained stable (pre-LVEF 48.9% ± 12.6% vs post-LVEF 50.1% ± 10.1%; P = .29), even in those without a cardiac resynchronization therapy (CRT) device (pre-LVEF 54.3% ± 8.0% vs post-LVEF 53.8% ± 8.0%; P = .65). Forty-nine patients (83.1%) reported an improvement in symptoms regardless of AF type (17/21 [81.0%] paroxysmal vs 32/38 [84.2%] persistent; P = 1.00), presence of baseline left ventricular impairment (22/26 [84.6%] LVEF ≤50% vs 27/33 [81.8%] LVEF ≥50%; P = 1.00) or CRT device (27/32 [84.4%] CRT vs 22/27 [81.5%] no CRT; P = 1.00). Symptoms improved in 16 patients (89.0%) who underwent AVN ablation to regularize rhythm. CONCLUSION: AVN ablation improved symptoms without impacting left ventricular function in the majority of patients. The data suggest that AVN ablation is an effective and safe management approach for AF in HCM and should be further evaluated in larger prospective studies.


Asunto(s)
Fibrilación Atrial , Cardiomiopatía Hipertrófica , Ablación por Catéter , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico , Cardiomiopatía Hipertrófica/terapia , Estudios Prospectivos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
2.
J Cardiovasc Electrophysiol ; 30(10): 1894-1903, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31397511

RESUMEN

INTRODUCTION: Multiple cardiac magnetic resonance (CMR)-derived indices of atrial fibrillation (AF) substrate have been shown in isolation to predict long-term outcome following catheter ablation. Left atrial (LA) fibrosis, LA volume, LA ejection fraction (EF), left ventricular ejection fraction (LVEF), LA shape (sphericity) and pulmonary vein anatomy have all been shown to correlate with late AF recurrence. This study aimed to validate and assess the relative contribution of multiple indices in a long-term single-center study. METHODS AND RESULTS: Eighty-nine patients (53% paroxysmal AF, 73% male) underwent comprehensive CMR study before first-time AF ablation (median follow-up 726 days [IQR: 418-1010 days]). The 3D late gadolinium-enhanced acquisition (1.5T, 1.3 × 1.3 × 2 mm) was quantified for fibrosis; LA volume and sphericity were assessed on manual segmentation at atrial diastole; LAEF and LVEF were quantified on multislice cine imaging. AF recurred in 43 patients (48%) overall (31 at 1 year). In the recurrence group, LA fibrosis was higher (42% vs 29%; hazard ratio [HR]: 1.032; P = .002), left atrial ejection fraction (LAEF) lower (25% vs 34%; HR: 0.063; P = .016) and LVEF lower (57% vs 63%; HR: 0.011; P = .008). LA volume (135 vs 124 mL) and sphericity (0.819 vs 0.822) were similar. Multivariate Cox regression analysis was adjusted for age and sex (Model 1), additionally AF type (Model 2) and combined (Model 3). In Models 1 and 2, LA fibrosis, LAEF, and LVEF were independently associated with outcome, but only LA fibrosis was independent in Model 3 (HR: 1.021; P = .022). CONCLUSIONS: LAEF, LVEF, and LA fibrosis differed significantly in the AF recurrence cohort. However, on combined multivariate analysis only LA fibrosis remained independently associated with outcome.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Imagen por Resonancia Cinemagnética , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Remodelación Atrial , Ablación por Catéter/efectos adversos , Femenino , Fibrosis , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recurrencia , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
3.
Eur J Prev Cardiol ; 26(16): 1707-1714, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-30776915

RESUMEN

BACKGROUND: A manned mission to Mars has been contemplated by the world's largest space agencies for a number of years. The duration of the trip would necessitate a much longer exposure to deep space radiation than any human has ever been exposed to in the past. Concern regarding cancer risk has thus far stalled the progress of deep space exploration; however, the effect of space radiation on the cardiovascular system is significantly less well understood. DISCUSSION: Damage by radiation in space is mediated by a number of sources, including X-rays, protons and heavier charged atomic nuclei (HZE ions, the high-energy component of galactic cosmic rays). Previously, only lunar mission astronauts have been exposed to significant deep space radiation, with all other missions being low earth orbits only. The effect of this radiation on the human body has been inconclusively studied, and the long-term damage caused to the vascular endothelium by this radiation due to the effect of high-energy particles is not well known. CONCLUSION: Current radiation shielding technology, which would be viable for use in spacecraft, would not eliminate radiation risk. Similar to how a variety of shielding techniques are used every day by radiographers, again without full risk elimination, we need to explore and better understand the effect of deep space radiation in order to ensure the safety of those on future space missions.


Asunto(s)
Astronautas , Enfermedades Cardiovasculares/etiología , Sistema Cardiovascular/efectos de la radiación , Radiación Cósmica/efectos adversos , Protección Radiológica/métodos , Vuelo Espacial , Nave Espacial , Enfermedades Cardiovasculares/prevención & control , Humanos
4.
Eur Heart J Case Rep ; 3(4): 1-6, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34109285

RESUMEN

BACKGROUND: Acute ST elevation myocardial infarction (STEMI) is a medical emergency and is most commonly due to atherosclerotic plaque rupture and occlusion of coronary vessels. This case demonstrates that eosinophilic granulomatosis with polyangiitis (EGPA) myocarditis can mimic acute STEMI. CASE SUMMARY: A 44-year-old woman presented with acute chest pain, shortness of breath, and collapse with ST elevation on electrocardiography. Coronary angiogram showed unobstructed coronaries and chest film revealed left-sided consolidation. Together with a thorough history, serum eosinophilia, cardiac magnetic resonance (CMR), and computated tomography imaging, the patient was diagnosed with acute EGPA myocarditis. She responded tremendously to steroid and cyclophosphamide immunosuppression and subsequent CMR imaging demonstrated complete resolution of myocarditis. DISCUSSION: CMR played a crucial role in the diagnosis and follow-up of this rare presentation. In patients who present as a STEMI but show unobstructed coronary vessels, EGPA may be a possible diagnosis.

5.
Europace ; 17(8): 1241-50, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25687748

RESUMEN

AIMS: To prospectively compare cardiac magnetic resonance late gadolinium enhancement (LGE) findings created by standard vs. robotically assisted catheter ablation lesions and correlate these with clinical outcomes. METHODS AND RESULTS: Forty paroxysmal atrial fibrillation patients (mean age 54 ± 13.8 years) undergoing first left atrial ablation were randomized to either robotic-assisted navigation (Hansen Sensei(®) X) or standard navigation. Pre-procedural, acute (24 h post-procedure) and late (beyond 3 months) scans were performed with LGE and T2W imaging sequences and percentage circumferential enhancement around the pulmonary vein (PV) antra were quantified. Baseline pre-procedural enhancements were similar in both groups. On acute imaging, mean % encirclements by LGE and T2W signal were 72% and 80% in the robotic group vs. 60% (P = 0.002) and 76%(P = 0.45) for standard ablation. On late imaging, the T2W signal resolved to baseline in both groups. Late gadolinium enhancement remained the predominant signal with 56% encirclement in the robotic group vs. 45% in the standard group (P = 0.04). At 6 months follow-up, arrhythmia-free patients had an almost similar mean LGE encirclement (robotic 64%, standard 60%, P = 0.45) but in recurrences, LGE was higher in the robotic group (43% vs. 30%, P = 0.001). At mean 3 years follow-up, 1.3 procedures were performed in the robotic group compared with 1.9 (P < 0.001) in the standard to achieve a success rate of 80% vs. 75%. CONCLUSION: Robotically assisted ablation results in greater LGE around the PV antrum. Effective lesions created through improved catheter stability and contact force during initial treatment may have a role in reducing subsequent re-do procedures.


Asunto(s)
Fibrilación Atrial/patología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Imagen por Resonancia Cinemagnética/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Cirugía Asistida por Computador/métodos , Medios de Contraste , Femenino , Gadolinio , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Resultado del Tratamiento
6.
Front Physiol ; 5: 414, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25389408

RESUMEN

Oscillations of arterial pressure occur spontaneously at a frequency of approximately 0.1 Hz coupled with synchronous oscillations of sympathetic nerve activity ("Mayer waves"). This study investigated the extent to which corresponding oscillations may occur in ventricular action potential duration (APD). Fourteen ambulatory (outpatient) heart failure patients with biventricular pacing devices were studied while seated upright watching movie clips to maintain arousal. Activation recovery intervals (ARI) as a measure of ventricular APD were obtained from unipolar electrograms recorded from the LV epicardial pacing lead during steady state RV pacing from the device. Arterial blood pressure was measured non-invasively (Finapress) and respiration monitored. Oscillations were quantified using time frequency and coherence analysis. Oscillatory behavior of ARI at the respiratory frequency was observed in all subjects. The magnitude of the ARI variation ranged from 2.2 to 6.9 ms (mean 5.0 ms). Coherence analysis showed a correlation with respiratory oscillation for an average of 43% of the recording time at a significance level of p < 0.05. Oscillations in systolic blood pressure in the Mayer wave frequency range were observed in all subjects for whom blood pressure was recorded (n = 13). ARI oscillation in the Mayer wave frequency range was observed in 6/13 subjects (46%) over a range of 2.9 to 9.2 ms. Coherence with Mayer waves at the p < 0.05 significance level was present for an average of 29% of the recording time. In ambulatory patients with heart failure during enhanced mental arousal, left ventricular epicardial APD (ARI) oscillated at the respiratory frequency (approximately 0.25 Hz). In 6 patients (46%) APD oscillated at the slower Mayer wave frequency (approximately 0.1 Hz). These findings may be important in understanding sympathetic activity-related arrhythmogenesis.

7.
IEEE J Transl Eng Health Med ; 2: 1800615, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-27170868

RESUMEN

Delayed-enhancement magnetic resonance imaging (DE-MRI) is an effective technique for detecting left atrial (LA) fibrosis both pre and postradiofrequency ablation for the treatment of atrial fibrillation. Fixed thresholding models are frequently utilized clinically to segment and quantify scar in DE-MRI due to their simplicity. These methods fail to provide a standardized quantification due to interobserver variability. Quantification of scar can be used as an endpoint in clinical studies and therefore standardization is important. In this paper, we propose a segmentation algorithm for LA fibrosis quantification and investigate its performance. The algorithm was validated using numerical phantoms and 15 clinical data sets from patients undergoing LA ablation. We demonstrate that the approach produces good concordance with expert manual delineations. The method offers a standardized quantification technique for evaluation and interpretation of DE-MRI scans.

8.
Indian J Tuberc ; 58(2): 88-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21644397

RESUMEN

Pulmonary infection due to Blastoschizomyces capitatus is less common. It is an emerging fungal pathogen. We describe a case of Blastoschizomyces capitatus pneumonia in an otherwise healthy female and review the clinical presentation, microbiological characteristics, and treatment for B. capitatus infection.


Asunto(s)
Enfermedades Pulmonares Fúngicas/diagnóstico , Neumonía/diagnóstico , Neumonía/microbiología , Trichosporon/aislamiento & purificación , Anciano , Antifúngicos/uso terapéutico , Diagnóstico Diferencial , Femenino , Fluconazol/uso terapéutico , Humanos , Inmunocompetencia , Enfermedades Pulmonares Fúngicas/tratamiento farmacológico , Neumonía/tratamiento farmacológico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA