Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Med Phys ; 51(2): 740-771, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38054538

RESUMEN

The last decade has seen a large growth in fluorescence-guided surgery (FGS) imaging and interventions. With the increasing number of clinical specialties implementing FGS, the range of systems with radically different physical designs, image processing approaches, and performance requirements is expanding. This variety of systems makes it nearly impossible to specify uniform performance goals, yet at the same time, utilization of different devices in new clinical procedures and trials indicates some need for common knowledge bases and a quality assessment paradigm to ensure that effective translation and use occurs. It is feasible to identify key fundamental image quality characteristics and corresponding objective test methods that should be determined such that there are consistent conventions across a variety of FGS devices. This report outlines test methods, tissue simulating phantoms and suggested guidelines, as well as personnel needs and professional knowledge bases that can be established. This report frames the issues with guidance and feedback from related societies and agencies having vested interest in the outcome, coming from an independent scientific group formed from academics and international federal agencies for the establishment of these professional guidelines.


Asunto(s)
Diagnóstico por Imagen , Procesamiento de Imagen Asistido por Computador , Fluorescencia , Fantasmas de Imagen
2.
Molecules ; 28(5)2023 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-36903411

RESUMEN

A series of mono- and bis-polyethylene glycol (PEG)-substituted BF2-azadipyrromethene fluorophores have been synthesized with emissions in the near-infrared region (700-800 nm) for the purpose of fluorescence guided intraoperative imaging; chiefly ureter imaging. The Bis-PEGylation of fluorophores resulted in higher aqueous fluorescence quantum yields, with PEG chain lengths of 2.9 to 4.6 kDa being optimal. Fluorescence ureter identification was possible in a rodent model with the preference for renal excretion notable through comparative fluorescence intensities from the ureters, kidneys and liver. Ureteral identification was also successfully performed in a larger animal porcine model under abdominal surgical conditions. Three tested doses of 0.5, 0.25 and 0.1 mg/kg all successfully identified fluorescent ureters within 20 min of administration which was sustained up to 120 min. 3-D emission heat map imaging allowed the spatial and temporal changes in intensity due to the distinctive peristaltic waves of urine being transferred from the kidneys to the bladder to be identified. As the emission of these fluorophores could be spectrally distinguished from the clinically-used perfusion dye indocyanine green, it is envisaged that their combined use could be a step towards intraoperative colour coding of different tissues.


Asunto(s)
Espectroscopía Infrarroja Corta , Uréter , Porcinos , Animales , Espectroscopía Infrarroja Corta/métodos , Colorantes Fluorescentes/química , Riñón , Vejiga Urinaria , Polietilenglicoles/química , Imagen Óptica/métodos
3.
Bioengineering (Basel) ; 10(3)2023 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-36978761

RESUMEN

Hyperspectral imaging (HSI) is a non-invasive, contrast-free optical-based tool that has recently been applied in medical and basic research fields. The opportunity to use HSI to identify exogenous tumor markers in a large field of view (LFOV) could increase precision in oncological diagnosis and surgical treatment. In this study, the anti-high mobility group B1 (HMGB1) labeled with Alexa fluorophore (647 nm) was used as the target molecule. This is the proof-of-concept of HSI's ability to quantify antibodies via an in vitro setting. A first test was performed to understand whether the relative absorbance provided by the HSI camera was dependent on volume at a 1:1 concentration. A serial dilution of 1:1, 10, 100, 1000, and 10,000 with phosphatase-buffered saline (PBS) was then used to test the sensitivity of the camera at the minimum and maximum volumes. For the analysis, images at 640 nm were extracted from the hypercubes according to peak signals matching the specificities of the antibody manufacturer. The results showed a positive correlation between relative absorbance and volume (r = 0.9709, p = 0.0013). The correlation between concentration and relative absorbance at min (1 µL) and max (20 µL) volume showed r = 0.9925, p < 0.0001, and r = 0.9992, p < 0.0001, respectively. These results demonstrate the HSI potential in quantifying HMGB1, hence deserving further studies in ex vivo and in vivo settings.

4.
Cells ; 12(4)2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-36831271

RESUMEN

The remarkable capacity of regeneration of the liver is well known, although the involved mechanisms are far from being understood. Furthermore, limits concerning the residual functional mass of the liver remain critical in both fields of hepatic resection and transplantation. The aim of the present study was to review the surgical experiments regarding liver regeneration in pigs to promote experimental methodological standardization. The Pubmed, Medline, Scopus, and Cochrane Library databases were searched. Studies evaluating liver regeneration through surgical experiments performed on pigs were included. A total of 139 titles were screened, and 41 articles were included in the study, with 689 pigs in total. A total of 29 studies (71% of all) had a survival design, with an average study duration of 13 days. Overall, 36 studies (88%) considered partial hepatectomy, of which four were an associating liver partition and portal vein ligation for staged hepatectomy (ALPPS). Remnant liver volume ranged from 10% to 60%. Only 2 studies considered a hepatotoxic pre-treatment, while 25 studies evaluated additional liver procedures, such as stem cell application, ischemia/reperfusion injury, portal vein modulation, liver scaffold application, bio-artificial, and pharmacological liver treatment. Only nine authors analysed how cytokines and growth factors changed in response to liver resection. The most used imaging system to evaluate liver volume was CT-scan volumetry, even if performed only by nine authors. The pig represents one of the best animal models for the study of liver regeneration. However, it remains a mostly unexplored field due to the lack of experiments reproducing the chronic pathological aspects of the liver and the heterogeneity of existing studies.


Asunto(s)
Regeneración Hepática , Hígado , Animales , Porcinos , Regeneración Hepática/fisiología , Hígado/patología , Hepatectomía , Vena Porta/patología , Vena Porta/cirugía , Modelos Anatómicos
5.
Adv Photonics Res ; 4(1)2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36643020

RESUMEN

Optical tissue phantoms (OTPs) have been extensively applied to the evaluation of imaging systems and surgical training. Due to their human tissue-mimicking characteristics, OTPs can provide accurate optical feedback on the performance of image-guided surgical instruments, simulating the biological sizes and shapes of human organs, and preserving similar haptic responses of original tissues. This review summarizes the essential components of OTPs (i.e., matrix, scattering and absorbing agents, and fluorophores) and the various manufacturing methods currently used to create suitable tissue-mimicking phantoms. As photobleaching is a major challenge in OTP fabrication and its feedback accuracy, phantom photostability and how the photobleaching phenomenon can affect their optical properties are discussed. Consequently, the need for novel photostable OTPs for the quantitative evaluation of surgical imaging devices is emphasized.

6.
Surg Endosc ; 37(3): 2395-2403, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36443562

RESUMEN

BACKGROUND: Single snapshot imaging of optical properties (SSOP) is a relatively new non-invasive, real-time, contrast-free optical imaging technology, which allows for the real-time quantitative assessment of physiological properties, including tissue oxygenation (StO2). This study evaluates the accuracy of multispectral SSOP in quantifying bowel ischaemia in a preclinical experimental model. METHODS: In six pigs, an ischaemic bowel segment was created by dividing the arcade branches. Five regions of interest (ROIs) were identified on the bowel loop, as follows: ROI 1: central ischaemic; ROI 2: left marginal; ROI 3: left vascularised; ROI 4: right marginal; and ROI 5: right vascularised. The Trident imaging system, specifically developed for real-time tissue oxygenation imaging using SSOP, was used to image before (T0) and after ischaemia induction. Capillary and systemic lactates were measured at each time point (T0, T15, T30, T45, T60), as well as StO2 values acquired by means of SSOP (SSOP-StO2). RESULTS: The mean value of SSOP-StO2 in ROI 1 was 30.08 ± 6.963 and was significantly lower when compared to marginal ROIs (ROI 2 + ROI 4: 45.67 ± 10.02 p = < 0.0001), and to vascularised ROIs (ROI 3 + ROI 5: 48.08 ± 7.083 p = < 0.0001). SSOP-StO2 was significantly correlated with normalised lactates r = - 0.5892 p < 0.0001 and with histology r =- 0.6251 p = 0.0002. CONCLUSION: Multispectral SSOP allows for a contrast-free accurate assessment of small bowel perfusion identifying physiological tissue oxygenation as confirmed with perfusion biomarkers.


Asunto(s)
Intestino Delgado , Ácido Láctico , Porcinos , Animales , Intestino Delgado/diagnóstico por imagen , Imagen Óptica/métodos , Isquemia/diagnóstico por imagen
7.
Cancers (Basel) ; 14(22)2022 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-36428685

RESUMEN

Ischemia-reperfusion injury during major hepatic resections is associated with high rates of post-operative complications and liver failure. Real-time intra-operative detection of liver dysfunction could provide great insight into clinical outcomes. In the present study, we demonstrate the intra-operative application of a novel optical technology, hyperspectral imaging (HSI), to predict short-term post-operative outcomes after major hepatectomy. We considered fifteen consecutive patients undergoing major hepatic resection for malignant liver lesions from January 2020 to June 2021. HSI measures included tissue water index (TWI), organ hemoglobin index (OHI), tissue oxygenation (StO2%), and near infrared (NIR). Pre-operative, intra-operative, and post-operative serum and clinical outcomes were collected. NIR values were higher in unhealthy liver tissue (p = 0.003). StO2% negatively correlated with post-operative serum ALT values (r = -0.602), while ΔStO2% positively correlated with ALP (r = 0.594). TWI significantly correlated with post-operative reintervention and OHI with post-operative sepsis and liver failure. In conclusion, the HSI imaging system is accurate and precise in translating from pre-clinical to human studies in this first clinical trial. HSI indices are related to serum and outcome metrics. Further experimental and clinical studies are necessary to determine clinical value of this technology.

8.
J Biomed Opt ; 27(7)2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35701869

RESUMEN

SIGNIFICANCE: Multi-laboratory initiatives are essential in performance assessment and standardization-crucial for bringing biophotonics to mature clinical use-to establish protocols and develop reference tissue phantoms that all will allow universal instrument comparison. AIM: The largest multi-laboratory comparison of performance assessment in near-infrared diffuse optics is presented, involving 28 instruments and 12 institutions on a total of eight experiments based on three consolidated protocols (BIP, MEDPHOT, and NEUROPT) as implemented on three kits of tissue phantoms. A total of 20 synthetic indicators were extracted from the dataset, some of them defined here anew. APPROACH: The exercise stems from the Innovative Training Network BitMap funded by the European Commission and expanded to include other European laboratories. A large variety of diffuse optics instruments were considered, based on different approaches (time domain/frequency domain/continuous wave), at various stages of maturity and designed for different applications (e.g., oximetry, spectroscopy, and imaging). RESULTS: This study highlights a substantial difference in hardware performances (e.g., nine decades in responsivity, four decades in dark count rate, and one decade in temporal resolution). Agreement in the estimates of homogeneous optical properties was within 12% of the median value for half of the systems, with a temporal stability of <5 % over 1 h, and day-to-day reproducibility of <3 % . Other tests encompassed linearity, crosstalk, uncertainty, and detection of optical inhomogeneities. CONCLUSIONS: This extensive multi-laboratory exercise provides a detailed assessment of near-infrared Diffuse optical instruments and can be used for reference grading. The dataset-available soon in an open data repository-can be evaluated in multiple ways, for instance, to compare different analysis tools or study the impact of hardware implementations.


Asunto(s)
Laboratorios , Óptica y Fotónica , Fantasmas de Imagen , Reproducibilidad de los Resultados , Análisis Espectral
9.
Minim Invasive Ther Allied Technol ; 31(3): 342-349, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33000653

RESUMEN

BACKGROUND: Urethral injury is a dreaded complication during laparoscopic, perineal and transanal surgery and is mainly a result of a failed visualization of the urethra. The aim of this systematic review is to provide an overview of the available literature on the near-infrared fluorescence (NIRF) imaging technique using contrast agents for the intra-operative visualization of the urethra. MATERIAL AND METHODS: A systematic review of the literature was conducted including studies on NIRF imaging using contrast agents to visualize the urethra. All studies describing a NIRF imaging technique and demonstrating visual findings of the urethra were included. RESULTS: Five studies were identified. Four studies examined indocyanine green, one of which also studied the IRDye® 800BK agent and one examined the CP-IRT dye. All studies showed that the NIRF imaging technique was feasible for an early identification of the urethra. No complications related to NIRF imaging were reported. CONCLUSION: We conclude that the use of a NIRF imaging technique is feasible and that it can contribute to prevent iatrogenic injury to the urethra. However, based on the limited available data, no solid conclusion can yet be drawn and further translation to the clinical practice is necessary.


Asunto(s)
Laparoscopía , Uretra , Colorantes Fluorescentes , Humanos , Verde de Indocianina , Laparoscopía/métodos , Masculino , Imagen Óptica/métodos , Uretra/diagnóstico por imagen , Uretra/cirugía
10.
Nat Rev Clin Oncol ; 19(1): 9-22, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34493858

RESUMEN

Fluorescence-guided surgery using tumour-targeted imaging agents has emerged over the past decade as a promising and effective method of intraoperative cancer detection. An impressive number of fluorescently labelled antibodies, peptides, particles and other molecules related to cancer hallmarks have been developed for the illumination of target lesions. New approaches are being implemented to translate these imaging agents into the clinic, although only a few have made it past early-phase clinical trials. For this translational process to succeed, target selection, imaging agents and their related detection systems and clinical implementation have to operate in perfect harmony to enable real-time intraoperative visualization that can benefit patients. Herein, we review key aspects of this imaging cascade and focus on imaging approaches and methods that have helped to shed new light onto the field of intraoperative fluorescence-guided cancer surgery with the singular goal of improving patient outcomes.


Asunto(s)
Neoplasias/diagnóstico por imagen , Neoplasias/cirugía , Imagen Óptica/métodos , Animales , Fluorescencia , Humanos , Ratones
11.
Cancers (Basel) ; 13(23)2021 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-34885189

RESUMEN

Anastomotic leakage (AL) is a serious complication occurring after esophagectomy. The current knowledge suggests that inadequate intraoperative perfusion in the anastomotic site contributes to an increase in the AL rate. Presently, clinical estimation undertaken by surgeons is not accurate and new technology is necessary to improve the intraoperative assessment of tissue oxygenation. In the present study, we demonstrate the application of a novel optical technology, namely Single Snapshot imaging of Optical Properties (SSOP), used to quantify StO2% in an open surgery experimental gastric conduit (GC) model. After the creation of a gastric conduit, local StO2% was measured with a preclinical SSOP system for 60 min in the antrum (ROI-A), corpus (ROI-C), and fundus (ROI-F). The removed region (ROI-R) acted as ischemic control. ROI-R had statistically significant lower StO2% when compared to all other ROIs at T15, T30, T45, and T60 (p < 0.0001). Local capillary lactates (LCLs) and StO2% correlation was statistically significant (R = -0.8439, 95% CI -0.9367 to -0.6407, p < 0.0001). Finally, SSOP could discriminate resected from perfused regions and ROI-A from ROI-F (the future anastomotic site). In conclusion, SSOP could well be a suitable technology to assess intraoperative perfusion of GC, providing consistent StO2% quantification and ROIs discrimination.

12.
Diagnostics (Basel) ; 11(9)2021 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-34573869

RESUMEN

Hyperspectral imaging (HSI) is a non-invasive imaging modality already applied to evaluate hepatic oxygenation and to discriminate different models of hepatic ischemia. Nevertheless, the ability of HSI to detect and predict the reperfusion damage intraoperatively was not yet assessed. Hypoxia caused by hepatic artery occlusion (HAO) in the liver brings about dreadful vascular complications known as ischemia-reperfusion injury (IRI). Here, we show the evaluation of liver viability in an HAO model with an artificial intelligence-based analysis of HSI. We have combined the potential of HSI to extract quantitative optical tissue properties with a deep learning-based model using convolutional neural networks. The artificial intelligence (AI) score of liver viability showed a significant correlation with capillary lactate from the liver surface (r = -0.78, p = 0.0320) and Suzuki's score (r = -0.96, p = 0.0012). CD31 immunostaining confirmed the microvascular damage accordingly with the AI score. Our results ultimately show the potential of an HSI-AI-based analysis to predict liver viability, thereby prompting for intraoperative tool development to explore its application in a clinical setting.

13.
J Biomed Opt ; 26(8)2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34414704

RESUMEN

SIGNIFICANCE: Quantitative stiffness information can be a powerful aid for tumor or fibrosis diagnosis. Currently, very promising elastography approaches developed for non-contact biomedical imaging are based on transient shear-waves imaging. Transient elastography offers quantitative stiffness information by tracking the propagation of a wave front. The most common method used to compute stiffness from the acquired propagation movie is based on shear-wave time-of-flight calculations. AIM: We introduce an approach to transient shear-wave elastography with spatially coherent sources, able to yield full-field quantitative stiffness maps with reduced artifacts compared to typical artifacts observed in time-of-flight. APPROACH: A noise-correlation algorithm developed for passive elastography is adapted to spatially coherent narrow or any band sources. This noise-correlation-inspired (NCi) method is employed in parallel with a classic time-of-flight approach. Testing is done on simulation images, experimental validation is conducted with a digital holography setup on controlled homogeneous samples, and full-field quantitative stiffness maps are presented for heterogeneous samples and ex-vivo biological tissues. RESULTS: The NCi approach is first validated on simulations images. Stiffness images processed by the NCi approach on simulated inclusions display significantly less artifacts than with a time-of-flight reconstruction. The adaptability of the NCi algorithm to narrow or any band shear-wave sources was tested successfully. Experimental testing on homogeneous samples demonstrates similar values for both the time-of-flight and the NCi approach. Soft inclusions in agarose sample could be resolved using the NCi method and feasibility on ex-vivo biological tissues is presented. CONCLUSIONS: The presented NCi approach was successful in computing quantitative full-field stiffness maps with narrow and broadband source signals on simulation and experimental images from a digital holography setup. Results in heterogeneous media show that the NCi approach could provide stiffness maps with less artifacts than with time-of-flight, demonstrating that a NCi algorithm is a promising approach for shear-wave transient elastography with spatially coherent sources.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Holografía , Algoritmos , Artefactos , Fantasmas de Imagen
14.
J Biomed Opt ; 26(6)2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34109769

RESUMEN

SIGNIFICANCE: Near-infrared (NIR) fluorescence imaging using indocyanine green (ICG) has proven to be a feasible application for real-time intraoperative assessment of tissue perfusion, although quantification of NIR fluorescence signals is pivotal for standardized assessment of tissue perfusion. AIM: Four patients are described with possible compromised bowel perfusion after mesenteric resection. Based on these patients we want to emphasize the difficulties in the quantification of NIR fluorescence imaging for perfusion analysis. APPROACH: During image-guided fluorescence assessment, 5 mg of ICG (2.5 mg / ml) was intravenously administered by the anesthesiologist. NIR fluorescence imaging was done with the open camera system of Quest Medical Imaging. Fluorescence data taken from the regions of interest (bowel at risk, transition zone of bowel at risk and adjacent normally perfused bowel, and normally perfused reference bowel) were quantitatively analyzed after surgery for fluorescence intensity-and perfusion time-related parameters. RESULTS: Bowel perfusion, as assessed clinically by independent surgeons based on NIR fluorescence imaging, resulted in different treatment strategies, three with excellent clinical outcome, but one with a perfusion related complication. Post-surgery quantitative analysis of fluorescence dynamics showed different patterns in the affected bowel segment compared to the unaffected reference segments for the four patients. CONCLUSIONS: Similar intraoperative fluorescence results could lead to different surgical treatment strategies, which demonstrated the difficulties in interpretation of uncorrected fluorescence signals. Real-time quantification and standardization of NIR fluorescence perfusion imaging could probably aid surgeons in the nearby future.


Asunto(s)
Verde de Indocianina , Imagen Óptica , Anastomosis Quirúrgica , Fluorescencia , Humanos , Intestinos , Perfusión
15.
J Biomed Opt ; 26(1)2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33515218

RESUMEN

SIGNIFICANCE: Oxygenation is one of the skin tissue physiological properties to follow for patient care management. Furthermore, long-term monitoring of such parameters is needed at the patient bed as well as outside the hospital. Diffuse reflectance spectroscopy has been widely used for this purpose. AIM: The aim of the study is to propose a low-cost system for the long-term measurement of skin physiological parameters in contact. APPROACH: We have developed a low-cost, wearable, CMOS-based device. We propose an original method for processing diffuse reflectance data to calculate the tissue oxygen saturation (StO2). RESULTS: We tested the device for the assessment of tissue oxygenation during a first-in-human clinical trial that took place at the Grenoble University Hospital France. CONCLUSIONS: The results of this clinical trial show a good accordance between our sensor and commercial devices used a reference.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Piel/diagnóstico por imagen , Análisis Espectral
16.
Surg Endosc ; 35(8): 4840-4848, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-32860134

RESUMEN

BACKGROUND: IRDye® 800BK is a fluorophore, currently undergoing clinical translation, which has both biliary and renal clearance. To date, there is no description of a fluorophore, which can be simultaneously used for non-invasive, near-infrared fluorescence-based (NIRF) visualization of different structures and perfusion evaluation. The purpose of this study was to evaluate IRDye® 800BK for the simultaneous assessment of bowel perfusion, lymphography, ureter and bile duct delineation. METHODS: Six pigs received a 0.15 mg/kg dye as a single bolus intravenous injection (IV). With the FLER (fluorescence-based enhanced reality) software, fluorescence intensity (FI) of 5 regions of interest (ROI) in an ischemic bowel loop was measured along with the time to reach the FI peak, and capillary lactate was measured from the same ROI, followed by the assessment of the ureters and bile ducts for a maximal duration of 180 min after dye administration. In 3 animals, the procedure was initiated via gastroscopic injection of a 0.6 mg (1 mg/mL) dye in the gastric submucosa followed by lymphography in a NIRF setting. RESULTS: Excellent visualization of the ureters and bowel perfusion was obtained under NIRF imaging. Additionally, the bile duct and gastric lymph ducts and nodes were visualized. A positive correlation was found between the time to peak FI in the ischemic bowel loop and the corresponding capillary lactate levels (rho 0.59, p < 0.001). CONCLUSION: In this study, we successfully demonstrated the simultaneous multipurpose IRDye® 800BK applicability during laparoscopic surgery. This fluorophore has the potential to become a powerful and versatile image-guided surgery tool.


Asunto(s)
Laparoscopía , Cirugía Asistida por Computador , Uréter , Animales , Fluorescencia , Colorantes Fluorescentes , Verde de Indocianina , Imagen Óptica , Porcinos , Uréter/diagnóstico por imagen , Uréter/cirugía
17.
Biomed Opt Express ; 11(10): 5701-5716, 2020 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33149980

RESUMEN

The development of real-time, wide-field and quantitative diffuse optical imaging methods to visualize functional and structural biomarkers of living tissues is a pressing need for numerous clinical applications including image-guided surgery. In this context, Spatial Frequency Domain Imaging (SFDI) is an attractive method allowing for the fast estimation of optical properties using the Single Snapshot of Optical Properties (SSOP) approach. Herein, we present a novel implementation of SSOP based on a combination of deep learning network at the filtering stage and Graphics Processing Units (GPU) capable of simultaneous high visual quality image reconstruction, surface profile correction and accurate optical property (OP) extraction in real-time across large fields of view. In the most optimal implementation, the presented methodology demonstrates megapixel profile-corrected OP imaging with results comparable to that of profile-corrected SFDI, with a processing time of 18 ms and errors relative to SFDI method less than 10% in both profilometry and profile-corrected OPs. This novel processing framework lays the foundation for real-time multispectral quantitative diffuse optical imaging for surgical guidance and healthcare applications. All code and data used for this work is publicly available at www.healthphotonics.org under the resources tab.

18.
Sci Rep ; 10(1): 15441, 2020 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-32963333

RESUMEN

Liver ischaemia reperfusion injury (IRI) is a dreaded pathophysiological complication which may lead to an impaired liver function. The level of oxygen hypoperfusion affects the level of cellular damage during the reperfusion phase. Consequently, intraoperative localisation and quantification of oxygen impairment would help in the early detection of liver ischaemia. To date, there is no real-time, non-invasive, and intraoperative tool which can compute an organ oxygenation map, quantify and discriminate different types of vascular occlusions intraoperatively. Hyperspectral imaging (HSI) is a non-invasive optical methodology which can quantify tissue oxygenation and which has recently been applied to the medical field. A hyperspectral camera detects the relative reflectance of a tissue in the range of 500 to 1000 nm, allowing the quantification of organic compounds such as oxygenated and deoxygenated haemoglobin at different depths. Here, we show the first comparative study of liver oxygenation by means of HSI quantification in a model of total vascular inflow occlusion (VIO) vs. hepatic artery occlusion (HAO), correlating optical properties with capillary lactate and histopathological evaluation. We found that liver HSI could discriminate between VIO and HAO. These results were confirmed via cross-validation of HSI which detected and quantified intestinal congestion in VIO. A significant correlation between the near-infrared spectra and capillary lactate was found (r = - 0.8645, p = 0.0003 VIO, r = - 0.7113, p = 0.0120 HAO). Finally, a statistically significant negative correlation was found between the histology score and the near-infrared parameter index (NIR) (r = - 0.88, p = 0.004). We infer that HSI, by predicting capillary lactates and the histopathological score, would be a suitable non-invasive tool for intraoperative liver perfusion assessment.


Asunto(s)
Modelos Animales de Enfermedad , Arteria Hepática/fisiopatología , Isquemia/fisiopatología , Hepatopatías/fisiopatología , Oxígeno/metabolismo , Imagen de Perfusión/métodos , Daño por Reperfusión/fisiopatología , Animales , Intestinos/fisiopatología , Masculino , Consumo de Oxígeno , Porcinos
19.
Opt Lett ; 45(15): 4232-4235, 2020 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-32735266

RESUMEN

We report on a macroscopic fluorescence lifetime imaging (MFLI) topography computational framework based around machine learning with the main goal of retrieving the depth of fluorescent inclusions deeply seated in bio-tissues. This approach leverages the depth-resolved information inherent to time-resolved fluorescence data sets coupled with the retrieval of in situ optical properties as obtained via spatial frequency domain imaging (SFDI). Specifically, a Siamese network architecture is proposed with optical properties (OPs) and time-resolved fluorescence decays as input followed by simultaneous retrieval of lifetime maps and depth profiles. We validate our approach using comprehensive in silico data sets as well as with a phantom experiment. Overall, our results demonstrate that our approach can retrieve the depth of fluorescence inclusions, especially when coupled with optical properties estimation, with high accuracy. We expect the presented computational approach to find great utility in applications such as optical-guided surgery.

20.
J Laparoendosc Adv Surg Tech A ; 30(9): 962-966, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32716245

RESUMEN

Background: Iatrogenic ureteral injury is one of the feared complications during intrapelvic surgery. There are limited data on the use of novel near-infrared fluorescence (NIRF) imaging dyes for the purpose of noninvasive ureteral visualization in robot-assisted laparoscopic surgery (RALS). In this study, we evaluated the feasibility of NIRF imaging of the ureter using the IRDye® 800BK dye as the fluorescence dye and a robotic platform with Firefly™ technology as an imaging system. Materials and Methods: An intravenous dose of 0.15 mg/kg was administered in 3 pigs and NIRF imaging was performed for a total duration of 60 minutes. The intraoperative video recordings were analyzed to determine fluorescence intensities and the target-to-background ratio (TBR). Results: In all included animals, a clear delineation of the ureter was achieved from 5 minutes after dye administration until the end of the study. During this time period, the ureter was clearly distinguishable from its surroundings and no statistical differences in TBR were observed. Conclusion: The IRDye 800BK dye, a novel NIRF dye currently undergoing clinical translation, is a promising contrast agent used for noninvasive ureteral imaging, which has the potential to be valuable during RALS.


Asunto(s)
Colorantes Fluorescentes , Indoles , Imagen Óptica/métodos , Uréter/diagnóstico por imagen , Animales , Femenino , Fluorescencia , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA