Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Rev Port Cardiol ; 43(1): 13-19, 2024 Jan.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-37423311

RESUMEN

INTRODUCTION AND OBJECTIVES: Patients with hypertrophic obstructive cardiomyopathy (HOCM) that remain symptomatic despite optimized medical therapy often undergo alcohol septal ablation (ASA). One of the most frequent complications is complete heart block (CHB), requiring a permanent pacemaker (PPM) in variable rates of up to 20% of patients. The long-term impact of PPM implantation in these patients remains unclear. This study aimed to evaluate the long-term clinical outcomes in patients who implant PPM after ASA. METHODS: Patients who underwent ASA at a tertiary center were consecutively and prospectively enrolled. Patients with previous PPM or implantable cardio-defibrillator were excluded from this analysis. Patients with and without PPM implantation after ASA were compared based on their baseline characteristics, procedure data and three-year primary endpoint of composite of all-cause mortality and hospitalization and secondary endpoint of composite of all-cause mortality and cardiac cause hospitalization. RESULTS: Between 2009 and 2019, 109 patients underwent ASA, 97 of whom were included in this analysis (68% female, mean age 65.2 years old). 16 patients (16.5%) required PPM implantation for CHB. In these patients, no vascular access, pacemaker pocket or pulmonary parenchyma complications were noted. The baseline characteristics of comorbidities, symptoms, echocardiographic and electrocardiographic findings were identical in the two groups, with higher mean age (70.6±10.0 years vs. 64.1±11.9 years) and lower beta-blocker therapy rate (56% vs. 84%) in the PPM group. Procedure-related data showed higher creatine kinase (CK) peaks in the PPM group (1692 U/L vs. 1243 U/L), with no significant difference in the alcohol dose. At three years after ASA procedure, there were no differences in the primary and secondary endpoints between the two groups. CONCLUSIONS: Permanent pacemaker after ASA induced CHB do not affect long term prognosis in hypertrophic obstructive cardiomyopathy patients.


Asunto(s)
Técnicas de Ablación , Cardiomiopatía Hipertrófica , Marcapaso Artificial , Humanos , Femenino , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Masculino , Tabiques Cardíacos/cirugía , Ecocardiografía , Cardiomiopatía Hipertrófica/cirugía , Marcapaso Artificial/efectos adversos , Bloqueo Cardíaco/etiología , Bloqueo Cardíaco/terapia , Resultado del Tratamiento , Técnicas de Ablación/efectos adversos , Técnicas de Ablación/métodos
2.
J Innov Card Rhythm Manag ; 14(9): 5576-5581, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37781719

RESUMEN

The heart failure risk status (HFRS) is a validated dynamic tool for risk score prediction, based on the TriageHF™ algorithm (Medtronic, Minneapolis, MN, USA), for the occurrence of a heart failure (HF) event in the 30 days following a remote monitoring (RM) transmission. The aim of this study was to evaluate the accuracy of the HFRS in predicting an unplanned hospital admission due to HF decompensation in a real-world cohort of patients submitted to cardiac resynchronization therapy (CRT). We conducted a single-center review of a cohort of 40 consecutive HF patients, under RM, with CRT devices using the HFRS of the TriageHF™ algorithm. The correlation of the HFRS with hospital admissions was analyzed. During a mean follow-up of 36 months, a stepwise increase in the HFRS was significantly associated with a higher risk of HF admission (odds ratio, 12.7; 95% confidence interval, 3.2-51.5; P < .001), and the HFRS was demonstrated to have good discrimination for HF hospitalization, with an area under the receiver-operating characteristic curve of 0.812. The TriageHF™ algorithm effectively predicted HF-related hospitalization in a cohort of CRT patients during long-term RM follow-up, providing a novel clinical pathway to optimize the clinical management of this complex population.

3.
Int J Cardiovasc Imaging ; 39(12): 2475-2481, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37821713

RESUMEN

Patients with hypertrophic cardiomyopathy may exhibit impaired functional capacity, associated with increased morbidity and mortality. Systolic function is one of the determinants of functional capacity. Early identification of systolic disfunction may identify patients at risk for adverse outcomes. Myocardial deformation parameters, derived from three-dimensional (3D) speckle-tracking echocardiography (3DSTE) are useful tools to assess left ventricular systolic function, and are often abnormal before a decline in ejection fraction is seen. The aim of this study was to evaluate the correlation between myocardial deformation parameters obtained by 3DSTE and functional capacity in patients with hypertrophic cardiomyopathy. Seventy-four hypertrophic cardiomyopathy adult patients were prospectively evaluated. All patients underwent a dedicated 2D and 3D echocardiographic examination and cardiopulmonary exercise testing (CPET). Values of 3D global radial (GRS), longitudinal (3DGLS) and circumferential strain (GCS) were overall reduced in our population: 99% (n = 73) of the patients had reduced GLS, 82% (n = 61) had reduced GRS and all patients had reduced GCS obtain by 3DSTE. Average peak VO2 was 21.01 (6.08) ml/Kg/min; 58% (n = 39) of the patients showed reduced exercise tolerance (predicted peak VO2 < 80%). The average VE/VCO2 slope was 29.0 (5.3) and 16% (n = 11) of the patients had impaired ventilatory efficiency (VE/VCO2 > 34). In multivariable analysis, 3D GLS (ß1 = 0.10, 95%CI: 0.03;0.23, p = 0.014), age (ß1 = -0.15, 95%CI: -0.23; -0.05, p = 0.002) and female gender (ß1 = -5.10, 95%CI: -7.7; -2.6, p < 0.01) were independently associated with peak VO2. No association was found between left ventricle ejection fraction obtain and peak VO2 (r = 0.161, p = 0.5). Impaired myocardial deformation parameters evaluated by 3DSTE were associated with worse functional capacity assessed by peak VO2.


Asunto(s)
Cardiomiopatía Hipertrófica , Ecocardiografía Tridimensional , Adulto , Humanos , Femenino , Tolerancia al Ejercicio , Valor Predictivo de las Pruebas , Ecocardiografía Tridimensional/métodos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Ecocardiografía/métodos
4.
Eur Heart J Case Rep ; 7(8): ytad368, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37601228

RESUMEN

Background: Heterotopic bicaval stenting or caval valve implantation (CAVI) either with non-dedicated balloon-expandable Sapien™ valves (Edwards Lifesciences) or with dedicated TricValve™ (Products + Features) has emerged as a safe and effective percutaneous treatment for high-risk patients with severe tricuspid regurgitation (TR). One technical difficulty of CAVI is the lack of native calcified structures to anchor the device, which may lead to paravalvular leak or migration. Cases summary: We describe two patients with severe TR and high surgical risk who underwent CAVI procedures, both of them complicated with device migration to the right atrium (one inferior vena cava device and one superior vena cava device). Both cases were treated with a caval valve-in-valve procedure, with good technical and clinical results. Discussion: With the recent development of several percutaneous interventions for high-risk patients with severe TR, the rate of some possible complications is not well established, and neither are the better managing strategies. Device embolization is a rare complication of transcatheter heart interventions but with potential catastrophic consequences. Less invasive strategies such as the valve-in-valve procedure may be preferable in order to avoid the exposure of these patients to complex heart surgeries with extracorporeal circulation.

5.
Cardiology ; 148(5): 469-477, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37429257

RESUMEN

INTRODUCTION: There are limited data about the outcomes of nonelective transcatheter aortic valve implantation (TAVI). Some studies suggest that these patients (pts) have worst results. Our purpose was to compare outcomes in pts submitted to urgent versus elective TAVI. METHODS: Retrospective analysis of 298 consecutive pts submitted to TAVI between 2018 and 2021 in a single tertiary center. Baseline characteristics and outcomes were collected and compared between elective and nonelective TAVI. RESULTS: Pts submitted to urgent TAVI (79 pts) had worse baseline characteristics, with higher EuroScore risk (9.26 vs. 5.17%, p < 0.0001), STS score (7.09 vs. 4.4%, p < 0.0001), and NT pro-natriuretic peptide B (10,168 vs. 3,241 pg/mL, p = 0.001), lower left ventricle ejection fraction (45 vs. 52%, p = 0.003), more diabetes (46.8 vs. 32.4%, p = 0.0.22), peripheral artery disease (21.5 vs. 6.8%, p < 0.0001), and poor vascular accesses (18.4 vs. 7.4%, p = 0.007). Urgent TAVI was associated with higher mortality (25.3 vs. 15.1%, p = 0.043), 30-day cardiovascular mortality (17.5 vs. 4%, p = 0.001), life-threatening bleeding (11.5 vs. 4.1%, p = 0.018), vascular complications (11.5 vs. 4.6%, p = 0.031), and longer hospital stay (28 vs. 12 days, p < 0.0001), but not with intensive care unit or post-TAVI hospital stay (5 vs. 4 days, p = 0.197 and 11 vs. 10 days, p = 0.572). When adjusted to differences in baseline characteristics, urgent TAVI was only associated with longer hospital stay (p < 0.0001). CONCLUSION: Pts submitted to urgent TAVI have worse short-term outcomes, but this seems to be attributable to the worse baseline characteristics instead of the urgent nature of the procedure.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/métodos
6.
Rev Port Cardiol ; 42(10): 847-855, 2023 10.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-37348835

RESUMEN

INTRODUCTION AND OBJECTIVES: Transesophageal echocardiography (TEE) has been the standard method for guiding left atrial appendage occlusion (LAAO) procedures. Recently, intracardiac echocardiography (ICE) has emerged as an alternative to TEE due to several advantages, particularly the avoidance of general anesthesia. This analysis aims to assess the safety, feasibility and efficacy of ICE-guided LAAO procedures. METHODS: We performed a retrospective analysis of ICE-guided LAAO procedures, including a comparison of embolic and bleeding events with the predicted standard scores and a comparison with TEE-guided procedures. RESULTS: A total of 88 patients underwent echocardiography-guided percutaneous LAAO (43 patients with TEE and 45 with ICE), mean age 74.9 years, 68.2% male. In the ICE-guided population, the technical success rate was 93% and the major complication rate was 8.8%. During follow-up, yearly stroke and major bleeding rates were 1.4% and 8.4%, respectively, compared to the 4.0% and 8.7% predicted by the CHA2DS2-VASc and HAS-BLED scores. In the TEE versus ICE analysis (similar baseline characteristics), no statistically significant differences were seen regarding technical success (95.3% vs. 93.3%), procedure-related complications (14.0% vs. 8.9%), device thrombus (2.3% vs. 0%), residual minor peridevice leaks (14.0% vs. 24.4%), one-year all-cause mortality (9.3% vs. 4.4%), stroke (9.3% vs. 2.2%) or major bleeding events (9.3% vs. 11.1%). CONCLUSION: ICE-guided LAAO was a safe and effective therapeutic strategy in a high embolic and bleeding risk population, compared to the event rates predicted by the CHA2DS2-VASc and HAS-BLED scores. The ICE-guided procedure compared well to TEE-guided procedures regarding procedure feasibility, safety, and efficacy.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Masculino , Anciano , Femenino , Estudios Retrospectivos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Resultado del Tratamiento , Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica/efectos adversos , Ecocardiografía/métodos , Hemorragia
8.
J Stroke Cerebrovasc Dis ; 32(5): 107054, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36881984

RESUMEN

BACKGROUND: Risk factors for stroke after transcatheter aortic valve implantation (TAVI) are currently incompletely understood. PURPOSE: To identify possible predictors of early post-TAVI stroke and explore its short-term outcomes. METHODS: Retrospective analysis of consecutive patients (pts) submitted to TAVI between 2009 and 2020 in a tertiary center. Baseline characteristics, procedural information and stroke in first 30 days after TAVI were collected. In-hospital and 12 months outcomes were analyzed. RESULTS: A total of 512pts (56,1% female, mean age of 82 ± 6years.) were included. In the first 30 days after TAVI 19pts (3,7%) had a stroke. In univariate analysis stroke was associated with higher body mass index (29 vs 27kg/m2, p=0.035), higher triglyceridemia (> 117,5mg/dL, p=0,002), lower high-density lipoprotein (< 38,5mg/dL, p=0,009) and porcelain aorta (36,8% vs 15,5%, p=0,014) and more frequent use of post-dilatation (58,8% vs 32%, p=0,021). In multivariate analysis, triglycerides > 117,5mg/dL (p=0,032, OR = 3,751) and post-dilatation (p=0,019, OR = 3,694) were the independent predictors. Stroke after TAVI was associated with longer intensive care unit stay (12 vs 4 days, p<0,001) and post-TAVI hospital stay (25 vs 10 days, p<0,0001), higher intra-hospital mortality (21,1% vs 4,3%, p=0,003), cardiovascular 30-day mortality (15,8% vs 4,1%, p=0,026) and 1-year stroke (13,2% vs 1,1%, p=0,003). CONCLUSION: Periprocedural and 30-day stroke is a relatively uncommon but potentially devastating complication after TAVI. In this cohort, 30-day stroke rate after TAVI was 3.7%. Hypertriglyceridemia and post-dilatation were found to be the only independent risk predictors. Outcomes after stroke, including 30-day mortality, were significantly worse.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
9.
J Cardiol Cases ; 27(3): 105-107, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36910037

RESUMEN

In the presence of prosthetic tricuspid valve, the inaccessibility to the right ventricle makes permanent pacing challenging. The placement of a left ventricle (LV) single lead in the coronary sinus (CS) is a well-accepted alternative, with some limitations regarding sensing and threshold. We describe a clinical case of a patient who had a previous LV only lead in the CS due to the presence of a prosthetic tricuspid valve and, after a surgical valvular intervention, presented with recurrent syncope episodes due to lead malfunction with lack of pacing capture and significant ventricular pauses. A quadripolar lead was chosen to be placed in the CS connected to a cardiac resynchronization therapy pacemaker device, programmed at biventricular VVI and using a specific manufacturer T-wave protection algorithm to prevent pacemaker-induced arrhythmias and to use the patient's own rhythm. This approach prevented a fourth surgical intervention to place an epicardial lead and resulted in reasonable LV sensing and pacing threshold. Learning objectives: This paper reports an alternative and atypical approach that could solve some of the limitations associated with ventricular pacing in patients with tricuspid prosthetic valves and multiple previous surgeries.

10.
Rev Port Cardiol ; 42(5): 455-465, 2023 05.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-36828182

RESUMEN

INTRODUCTION: Coronary vasomotion disorders (CVDs), including microvascular angina (MVA) and vasospastic angina (VSA), account for significant morbidity among patients with non-obstructive coronary artery disease (NOCAD). However, protocols for CVD assessment in clinical practice are seldom standardized and may be difficult to implement. PURPOSE: To assess the safety and feasibility of a comprehensive coronary function test (CFT) protocol for assessment of CVD and the prevalence of different phenotypes of CVD in patients with angina and NOCAD (ANOCA). METHODS: Patients with persistent angina referred for invasive coronary angiogram and found to have NOCAD were prospectively recruited and underwent a CFT. Functional parameters (fractional flow reserve, coronary flow reserve and index of myocardial resistance) and coronary vasoreactivity were assessed in all patients. RESULTS: Of the 20 patients included, the mean age was 63±13 years and 50% were females. Most patients had persistent typical angina and evidence of ischemia in noninvasive tests (75%). The CFT was successfully performed in all subjects without serious complications. Isolated MVA was found in 25%, isolated VSA in 40%, both MVA and VSA in 10% and noncardiac chest pain in 25% of patients. Antianginal therapy was modified after the results of CFT in 70% of patients. CONCLUSION: A coronary function test was feasible and safe in a cohort of patients with ANOCA. CVD were prevalent in this selected group of patients, and some presented mixed CVD phenotypes. CFT may provide a definitive diagnosis in patients with persistent angina and prompt the stratification of pharmacological therapy.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Angina Microvascular , Femenino , Masculino , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Angina Microvascular/diagnóstico , Angina Microvascular/epidemiología , Angiografía Coronaria , Isquemia , Vasos Coronarios
12.
Rev Port Cardiol ; 41(8): 621-631, 2022 Aug.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-36073258

RESUMEN

BACKGROUND: Some studies suggest that patients with low flow low gradient (LF-LG) aortic stenosis (AS) may achieve worse results after undergoing transcatheter aortic valve implantation (TAVI). PURPOSE: To compare outcomes between LF-LG AS and high gradient (HG) AS patients submitted to TAVI. METHODS: Inclusion of 480 consecutive patients who underwent TAVI between 2008 and 2020 at a single tertiary center. Patients were divided into high gradient AS and LF-LG AS; and baseline characteristics and outcomes after the procedure were collected and compared between groups. RESULTS: Patients with LF-LG AS had worse baseline characteristics, with higher Society of Thoracic Surgeons score (p=0.008), New Euroscore II (p<0.0001), and NT pro-natriuretic peptide B (p=0.001), more frequent left ventricular ejection fraction (LVEF) <40% (p<0.0001), coronary artery disease (p<0.0001), including previous myocardial infarction (p=0.002) and coronary artery bypass graft (p<0.0001), poor vascular accesses (p=0.026) and periprocedural angioplasty (p=0.038). In a multivariate analysis, adjusted to differences in baseline characteristics, LF-LG AS was associated with worse functional class at one year (p=0.023) and in the long-term (p=0.004) and with heart failure hospitalizations at one year and in the long-term (p=0.001 and p<0.0001). In a sub-analysis including only patients with LF-LG AS, those with LVEF <40% had the worst outcomes, with more global (p=0.035) and cardiovascular (p=0.038) mortality. CONCLUSION: Patients with LF-LG AS have worse short and long-term outcomes, even when adjusted for baseline characteristic differences. The sub-group of patients with LVEF <40% have the most ominous global outcomes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA