Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Shoulder Elbow Surg ; 31(2): 302-309, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34411724

RESUMEN

BACKGROUND: Preoperative planning for total shoulder arthroplasty (TSA) may change according to the measured degree of glenoid version. Both 2-dimensional (2D) and 3-dimensional (3D) computed tomographic (CT) scans are used to measure glenoid version, with no consensus on which method is more accurate. However, it is generally accepted that 3D measurements are more reliable, yet most 3D reconstruction software currently in clinical use have never been directly compared to 2D. The purpose of this study is to directly compare 2D and 3D glenoid version measurements and determine the differences between the two. METHODS: CT scans were performed preoperatively on 315 shoulders undergoing either anatomic or reverse TSA. 2D measurements of glenoid version were obtained manually using the Friedman method, whereas 3D measurements were obtained using the Equinoxe Planning Application (Exactech Inc.) 3D-reconstruction software. Negative version values indicate retroversion, whereas positive values indicate anteversion. Two observers collected the 2D measurements 2 separate times, and intra- and interobserver measurements were calculated. Groups were compared for variability using intraclass correlation coefficients (ICCs), and for differences in sample means using Student t tests. Additionally, samples were stratified by version value in order to better understand the potential sources of error between measurement techniques. RESULTS: For the 2D measurements, intraobserver variability indicated excellent reproducibility for both observer 1 (ICC = 0.928, 95% confidence interval [CI] 0.911-0.942) and observer 2 (ICC = 0.964, 95% CI 0.955-0.971). Interobserver variability measurements also indicated excellent reproducibility (ICC = 0.915, 95% CI 0.778-0.956). The overall 2D version measurement average (-4.9° ± 10.3°) was significantly less retroverted than the 3D measurement average (-8.4° ± 9.1°) (P < .001), with 3D measurements yielding a more retroverted value 73% of the time. When stratified on the basis of version value with outliers excluded, there was no significant difference in the distribution of high-error samples within the data. DISCUSSION: There was excellent reproducibility between the 2 observers in terms of both intra- and interobserver variability. The 3D measurement techniques were significantly more likely to return a more retroverted measurement, and high-error samples were evenly distributed throughout the data, indicating that there were no discernable trends in the degree of error observed. Shoulder surgeons should be aware that different glenoid version measurement strategies can yield different version measurements, as these can affect preoperative planning and surgeon decision making.


Asunto(s)
Cavidad Glenoidea , Articulación del Hombro , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados , Escápula , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Programas Informáticos
2.
J Shoulder Elbow Surg ; 29(12): 2610-2618, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33190760

RESUMEN

BACKGROUND: Preoperative planning software is widely available for most anatomic total shoulder arthroplasty (ATSA) systems. It can be most useful in determining implant selection and placement with advanced glenoid wear. The purpose of this study was to quantify inter- and intrasurgeon variability in preoperative planning of a series of ATSA cases. METHODS: Forty-nine computed tomography scans were planned for ATSA by 9 fellowship-trained shoulder surgeons using the ExactechGPS platform (Exactech Inc., Gainesville, FL, USA). Each case was planned a second time between 4 and 12 weeks later. Variability within and between surgeons was measured for implant type, size, version and inclination correction, and implant face position. Interclass correlation coefficients, Pearson, and Light's kappa coefficients were used for statistical analysis. RESULTS: There was considerable variation in the frequency of augment use between surgeons and between rounds for the same surgeon. Thresholds for augment use also varied between surgeons. Interclass correlation coefficients for intersurgeon variability were 0.37 for version, 0.80 for inclination, 0.36 for implant type, and 0.36 for implant size. Pearson coefficients for intrasurgeon variability were 0.17 for version and 0.53 for inclination. Light's kappa coefficient for implant type was 0.64. CONCLUSIONS: This study demonstrates substantial inter- and intrasurgeon variability in preoperative planning of ATSA. Although the magnitude of differences in correction was small, surgeons differed significantly in the use of augments to achieve the resultant plan. Surgeons differed from each other on thresholds for augment use and maximum allowable residual retroversion. This suggests that there may a range of acceptable corrections for each shoulder rather than a single optimal plan.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Desviación Ósea/diagnóstico por imagen , Cuidados Preoperatorios/métodos , Articulación del Hombro , Prótesis de Hombro , Cirugía Asistida por Computador/métodos , Artroplastía de Reemplazo de Hombro/métodos , Desviación Ósea/prevención & control , Desviación Ósea/cirugía , Humanos , Imagenología Tridimensional , Variaciones Dependientes del Observador , Escápula/diagnóstico por imagen , Escápula/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Programas Informáticos , Cirugía Asistida por Computador/normas , Tomografía Computarizada por Rayos X
3.
J Shoulder Elbow Surg ; 29(10): 2080-2088, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32471752

RESUMEN

BACKGROUND: Preoperative planning software is gaining utility in reverse total shoulder arthroplasty (RTSA), particularly when addressing pathologic glenoid wear. The purpose of this study was to quantify inter- and intrasurgeon variability in preoperative planning a series of RTSA cases to identify differences in how surgeons consider optimal implant placement. This may help identify opportunities to establish consensus when correlating plan differences with clinical data. METHODS: A total of 49 computed tomography scans from actual RTSA cases were planned for RTSA by 9 fellowship-trained shoulder surgeons using the same platform (Exactech GPS, Exactech Inc., Gainesville, FL, USA). Each case was planned a second time 6-12 weeks later. Variability within and between surgeons was measured for implant selection, version correction, inclination correction, and implant face position. Interclass correlation coefficients, and Pearson and Light's kappa coefficient were used for statistical analysis. RESULTS: There was considerable variation in the frequency of augmented baseplate selection between surgeons and between rounds for the same surgeon. Thresholds for augment use also varied between surgeons. Interclass correlation coefficients for intersurgeon variability ranged from 0.43 for version, 0.42 for inclination, and 0.25 for baseplate type. Pearson coefficients for intrasurgeon variability were 0.34 for version and 0.30 for inclination. Light's kappa coefficient for baseplate type was 0.61. CONCLUSIONS: This study demonstrates substantial variability both between surgeons and between rounds for individual surgeons when planning RTSA. Although average differences between plans were relatively small, there were large differences in specific cases suggesting little consensus on optimal planning parameters and opportunities to establish guidelines based on glenoid pathoanatomy. The correlation of preoperative planning with clinical outcomes will help to establish such guidelines.


Asunto(s)
Artroplastía de Reemplazo de Hombro/métodos , Pautas de la Práctica en Medicina , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Cirujanos , Artroplastía de Reemplazo de Hombro/instrumentación , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía , Humanos , Periodo Preoperatorio , Escápula/cirugía , Prótesis de Hombro , Programas Informáticos , Tomografía Computarizada por Rayos X
4.
J Ethnopharmacol ; 244: 112164, 2019 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-31419498

RESUMEN

ETHNOPHARMACOLOGICAL RELEVANCE: Ethnoveterinary medicine is vastly under-documented, especially in North Africa, where livestock care is increasingly medicalised. Despite evidence of the interdependence of ethnoveterinary practices and ethnomedicine for human care, the overlap between these two systems and the possible drivers of similarity are rarely addressed in ethnopharmacological literature. Here, we present the first quantitative comparison of remedies used to treat human and animal health among a pastoral society. AIMS: This study aims to document the plants and other materials used in ethnoveterinary medicine among nomadic herders in the Algerian steppe. We calculate the overlap with remedies used for human health and evaluate some of the possible drivers of similarities between the two interlinked medical systems. METHODS: The field study was conducted in spring 2018 with 201 local knowledge holders in five provinces in the central part of the Algerian steppe. Forty-six camps and ten weekly animal markets were visited. After obtaining prior informed consent, data was collected through structured interviews. Anonymous sociodemographic information was collected along with veterinary use data. Plant specimens were acquired, identified and deposited in the Botanical Laboratory Herbarium of the University of Tiaret. Ethnobotanical information was structured in use reports and therapeutic applications organised into 13 simple categories. Plants used in ethnoveterinary medicine were compared to those used in human health care using a Chi square test, and ethnoveterinary use was predicted using a generalised linear model with use for human care and plant family as predictive variables. Logistic regressions were also used to test if any specific medicinal application predicts shared use in human and veterinary medicine. RESULTS: Sixty-six plant species from 32 botanical families and ten non-vegetable remedies were documented. Plants from the Lamiaceae, Asteraceae, Fabaceae and Apiaceae families were most commonly used. The plants most often cited by interviewees are all harvested from the wild (Echinops spinosissimus Turra, Atriplex halimus L., Artemisia campestris L., Juniperus phoenicea L. and Peganum harmala L.). Leaves are the most commonly used plant part and decoction is the most common preparation method. There are important similarities between remedies used to treat humans and other animals: two thirds of the remedies used in ethnoveterinary medicine are also used in human health care, and these represent half of the human health treatments. Use for human health and plant family both predict the use of a medicinal plant in veterinary medicine, but no correlation is found regarding specific therapeutic applications. CONCLUSIONS: Traditional veterinary knowledge is still key to sheep and goat herders in the Algerian steppe, but a knowledge transmission gap seems to exist between older and younger generations, and ethnoveterinary practices may disappear in the near future. Treatments for human and animal care overlap to a large extent, and a causal relationship possibly exists for, at least, some of them. However, overall a smaller number of remedies are used to treat animals than humans and for less therapeutic applications. This difference in the diversity of therapeutic applications and remedies should be the object of future research.


Asunto(s)
Enfermedades de los Animales/tratamiento farmacológico , Conocimientos, Actitudes y Práctica en Salud , Medicina Tradicional , Fitoterapia/veterinaria , Plantas Medicinales , Adulto , Argelia , Animales , Etnofarmacología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Migrantes , Adulto Joven
5.
Sociol Health Illn ; 34(1): 49-63, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21668455

RESUMEN

This article explores how health inequalities are constructed as an object for policy intervention by considering four framings: politics, audit, evidence and treatment. A thematic analysis of 197 interviews conducted with local managers in England, Scotland and Wales is used to explore how these framings emerge from local narratives. The three different national policy regimes create contrasting contexts, especially regarding the different degrees of emphasis in these regimes on audit and performance management. We find that politics dominates how health inequalities are framed for intervention, affecting their prioritisation in practice and how audit, evidence and treatment are described as deployed in local strategies.


Asunto(s)
Política de Salud , Disparidades en el Estado de Salud , Gobierno Local , Política , Medicina Estatal/organización & administración , Estudios de Casos y Controles , Prioridades en Salud/economía , Prioridades en Salud/legislación & jurisprudencia , Humanos , Evaluación de Procesos y Resultados en Atención de Salud , Formulación de Políticas , Administración en Salud Pública/economía , Administración en Salud Pública/métodos , Sociología Médica , Medicina Estatal/economía , Reino Unido
6.
Inform Prim Care ; 16(1): 3-8, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18534072

RESUMEN

INTRODUCTION: Recent evaluations of IT innovations in primary care have highlighted variations between centres and practices in uptake and use. We evaluated whether structural characteristics of a general practice were associated with variations in use of a web-based clinical information system underpinning a Managed Clinical Network in diabetes, between the years 2001 and 2003. METHODS: Using a computerised audit trail, we calculated the numbers of web-based operations that occurred in each practice, stratified by staff type and year, and adjusted for the numbers of registered diabetic patients. In regression analyses, we determined whether total use was associated with structural characteristics of the practice (total list size, training status, numbers of GPs (general practitioners), mean age of the GPs, numbers of female GPs, level of deprivation of the population and whether staff had received advanced training in diabetes care). RESULTS: Initially there were a few practices which made very frequent use of the information system, with relatively high numbers of practices using the facility infrequently. However, overall use gradually became more evenly spread. This effect was particularly evident among nurse users. Frequent use by GPs was evident in only a small number of practices, with mean GP use decreasing over the three years. In linear regression analyses, none of the general practice variables were associated with online use, either overall or stratified by staff type, except for the numbers of diabetes-educated staff. This was consistently associated with increased use by nurses and GPs. CONCLUSIONS: The analyses show that structural characteristics of a practice are not associated with uptake of a new IT facility, but that its use may be influenced by post-graduate education in the relevant clinical condition. For this diabetes system at least, practice nurse use was critical in spreading uptake beyond initial GP enthusiasts and for sustained and rising use in subsequent years.


Asunto(s)
Difusión de Innovaciones , Medicina Familiar y Comunitaria/organización & administración , Sistemas de Información/organización & administración , Sistemas de Información/estadística & datos numéricos , Internet , Factores de Edad , Diabetes Mellitus/terapia , Manejo de la Enfermedad , Humanos , Factores Sexuales , Factores Socioeconómicos , Factores de Tiempo
7.
Clin Orthop Relat Res ; 466(7): 1699-704, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18443893

RESUMEN

Stainless steel screws and other internal fixation devices are used routinely to stabilize bacteria-contaminated bone fractures from multiple injury mechanisms. In this preliminary study, we hypothesize that a chitosan coating either unloaded or loaded with an antibiotic, gentamicin, could lessen or prevent these devices from becoming an initial nidus for infection. The questions investigated for this hypothesis were: (1) how much of the sterilized coating remains on the screw with simulated functional use; (2) is the unloaded or loaded chitosan coating bacteriostatic and biocompatible; and (3) what amount and rate does an antibiotic elute from the coating? In this study, the gentamicin eluted from the coating at a detectable level during 72 to 96 hours. The coating was retained at the 90% level in simulated bone screw fixation and the unloaded and loaded chitosan coatings had encouraging in vitro biocompatibility with fibroblasts and stem cells and were bacteriostatic against at least one strain of Staphylococcus aureus. The use of an antibiotic-loaded chitosan coating on stainless steel bone screws and internal fixation devices in contaminated bone fracture fixation may be considered after optimization of antibiotic loading and elution and more expanded in vitro and in vivo investigations with other organisms and antibiotics.


Asunto(s)
Tornillos Óseos , Quitosano , Materiales Biocompatibles Revestidos , Fijación Interna de Fracturas/instrumentación , Fracturas Óseas/cirugía , Antibacterianos/administración & dosificación , Infecciones Bacterianas/complicaciones , Infecciones Bacterianas/prevención & control , Fracturas Óseas/complicaciones , Gentamicinas/administración & dosificación , Humanos , Ensayo de Materiales , Pruebas de Sensibilidad Microbiana , Modelos Biológicos , Acero Inoxidable
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA