1.
Transplant Proc ; 47(6): 1958-65, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26293081

RESUMEN

BACKGROUND: Since the first reported series in 1995, transplantation of lungs recovered through donation after circulatory determination of death (DCDD) has steadily increased. In some European and Australian centers, controlled DCDD accounts for 15% to 30% of all transplanted lungs. Several transplant centers have reported early and midterm outcomes similar to those associated with the use of donors after brain death. Despite these encouraging reports, less than 2% of all lung transplants in the United States are performed using donors after circulatory determination of death. METHODS: An electronic search from January 1990 to January 2014 was performed to identify series reporting lung transplant outcomes using controlled DCDD. Data from these publications were analyzed in terms of donor characteristics, donation after circulatory determination of death protocols, recipients' characteristics, and early and midterm outcomes. RESULTS: Two hundred twenty-two DCDDs were transplanted into 225 recipients. The rate of primary graft dysfunction grade 3 ranged from 3% to 36%. The need for extracorporeal membrane oxygenation support after transplantation ranged from 0% to 18%. The average intensive care unit stay ranged from 4 to 8.5 days and the average hospital stay ranged from 14 to 35 days. Thirty-day mortality ranged from 0% to 11% and 1-year survival from 88% to 100%. CONCLUSION: Under clinical protocols developed and strictly applied by several experienced lung transplant programs, lungs from controlled DCDD have produced outcomes very similar to those observed with brain death donors.


Asunto(s)
Muerte Encefálica/diagnóstico , Trasplante de Pulmón/métodos , Donantes de Tejidos/provisión & distribución , Obtención de Tejidos y Órganos/organización & administración , Humanos , Disfunción Primaria del Injerto/prevención & control
2.
Transplant Proc ; 46(7): 2453-5, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25242800

RESUMEN

Liberalization in donor selection criteria allowed centers to increase the number of lung transplants, yet less than 25% of all donors had lungs utilized for transplantation in the United States in 2013. Less than 5% of all transplanted donors deviate 3 or more criteria from the ideal donor. Ex vivo lung perfusion (EVLP) provides the opportunity to increase the percentage of used donors by acting on modifiable selection criteria such as oxygenation, contusion and pulmonary infiltrates. We report the pre-transplant use of EVLP in the salvage of lungs from a donor that developed neurogenic pulmonary edema -PaO2 188 mmHg-. The recipient had a lung allocation score of 69.3. The post-operative course was excellent and was discharged home after 15 days. He is alive and doing well 780 days after transplant. In this report the pre-transplant use of EVLP led not only to transplanting lungs that otherwise would not have been used by many centers, but also to a very short and typical period of post-operative mechanical ventilation and hospital stay.


Asunto(s)
Trasplante de Pulmón , Pulmón/cirugía , Perfusión , Edema Pulmonar/terapia , Donantes de Tejidos , Selección de Donante , Humanos , Pulmón/irrigación sanguínea , Masculino , Edema Pulmonar/complicaciones
3.
Br J Anaesth ; 98(1): 23-8, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17098722

RESUMEN

BACKGROUND: I.V. infusion of drag-reducing polymers (DRPs) has been shown to improve survival time in animals subjected to haemorrhagic shock. We hypothesized that DRPs might prolong survival time in rats following acute myocardial ischaemia (AMI). METHODS: Sixteen adult male rats were anaesthetized and mechanically ventilated. An i.v. infusion of either Dextran-40 2.5% (Control, n=8) or Dextran-40 2.5% containing 50 microg ml(-1) of an aloe vera-based DRP (DRP, n=8) was initiated at 3.5 ml h(-1). The left anterior descending coronary artery was ligated. Blood pressure, skin-tissue perfusion, and heart rate were monitored and arterial blood samples were analysed. RESULTS: The mortality at 60 min following coronary ligation was 0% in the DRP group vs 50% in the control group (P=0.025). DRP-treated animals maintained higher mean arterial pressure [60.9 (5.1) vs 47.5 (5.1) mm Hg, P=0.004] and tissue perfusion [4.2 (3.4) vs 1.2 (0.5) TPU, P=0.029]. The DRP group trended towards better acid-base status with base excess [-5.0 (1.7) vs -8.1 (5.1) mmol litre(-1), P=0.083] and pH [7.42 (0.07) vs 7.35 (0.02), P=0.03]. CONCLUSIONS: Administration of nanomolar concentrations of aloe vera-based DRP prolonged survival time in animals with AMI. DRPs may offer a novel method to treat organ/tissue hypoperfusion.


Asunto(s)
Aloe , Isquemia Miocárdica/tratamiento farmacológico , Fitoterapia/métodos , Enfermedad Aguda , Animales , Presión Sanguínea/efectos de los fármacos , Dióxido de Carbono/sangre , Frecuencia Cardíaca/efectos de los fármacos , Concentración de Iones de Hidrógeno , Infusiones Intravenosas , Masculino , Isquemia Miocárdica/mortalidad , Isquemia Miocárdica/fisiopatología , Oxígeno/sangre , Presión Parcial , Extractos Vegetales/uso terapéutico , Polímeros/uso terapéutico , Ratas , Ratas Sprague-Dawley , Tasa de Supervivencia
4.
Eur Respir J ; 23(3): 378-83, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15065825

RESUMEN

Post-lung transplant use of aerosol cyclosporin (ACsA) is considered by examining the relationship between deposited aerosol dose and effect. In a sub-study of placebo controlled trials of ACsA as a rejection prophylaxis, 15 drug subjects received aerosol dose quantification tests to gage their ability to effectively deposit the nebulised drug in their transplanted lung(s). A total of seven placebo subjects received mock deposition tests. The deposited doses and mock doses were compared to changes in the forced expiratory volume in one second, at six time points during the 2-yr trial period (ACsA was started within 6 weeks post-transplant). Linear relationships were demonstrated between deposited dose and improvement in lung function in the drug subjects at all intervals. Mock dose data from placebo subjects did not demonstrate similar correlation. Based on these results, subjects were grouped by dose and compared. Subjects depositing > or = 5 mg of the drug in the periphery of their transplant(s) had improving pulmonary function on average. Low-dose and placebo subjects demonstrated declines, more A2-A4 rejection events in the latter portion of the trial, and more chronic rejection beyond the end of the trial. A dose-to-effect relationship is demonstrated for aerosol cyclosporin in terms of pulmonary function and biopsy proven rejection.


Asunto(s)
Ciclosporina/administración & dosificación , Inmunosupresores/administración & dosificación , Trasplante de Pulmón/fisiología , Administración por Inhalación , Aerosoles , Ciclosporina/uso terapéutico , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Rechazo de Injerto/prevención & control , Humanos , Inmunosupresores/uso terapéutico , Periodo Posoperatorio
5.
Eur Respir J ; 23(3): 384-90, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15065826

RESUMEN

The majority of patients who develop bronchiolitis obliterans, after lung transplantation, die within 2-3 yrs after onset since treatment with conventional immunosuppression is typically ineffective. A case/control study was conducted in lung transplant recipients with biopsy-documented bronchiolitis obliterans to determine whether aerosol cyclosporin use contributed to increased survival. The cases comprised 39 transplant recipients who received open-label aerosol cyclosporin treatment in addition to conventional immunosuppression. The controls were transplant recipients treated with conventional immunosuppression alone. There were 51 controls from the University of Pittsburgh Medical Center and 100 from a large multicentric database (Novartis Lung Transplant Database). Forced expiratory volume in one second expressed as a percentage of the predicted value was an independent predictor of survival in all patients with bronchiolitis obliterans. Cox proportional-hazards analysis revealed a survival advantage for aerosol cyclosporin cases compared to the Pittsburgh control group. A survival advantage was also seen when comparing study cases to multicentric controls. Aerosol cyclosporin, given with conventional immunosuppression to lung transplant recipients with bronchiolitis obliterans, provides a survival advantage over conventional therapy alone.


Asunto(s)
Bronquiolitis Obliterante/tratamiento farmacológico , Ciclosporina/administración & dosificación , Inmunosupresores/administración & dosificación , Trasplante de Pulmón , Complicaciones Posoperatorias/tratamiento farmacológico , Administración por Inhalación , Adulto , Aerosoles , Bronquiolitis Obliterante/mortalidad , Estudios de Casos y Controles , Ciclosporina/uso terapéutico , Femenino , Rechazo de Injerto/prevención & control , Humanos , Inmunosupresores/uso terapéutico , Trasplante de Pulmón/mortalidad , Masculino , Complicaciones Posoperatorias/mortalidad , Modelos de Riesgos Proporcionales , Análisis de Supervivencia
6.
J Heart Lung Transplant ; 20(11): 1199-212, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11704480

RESUMEN

BACKGROUND: Increasing numbers of individuals receive ventricular assist devices (VADs) as bridges to heart transplantation. Physical morbidity risks and benefits, and quality of life (QOL) during VAD support have been documented. Effects of pre-transplant VAD support on functional and QOL outcomes after transplantation have received no empirical attention. METHODS: Sixty-three VAD patients who received heart transplants underwent QOL evaluations of physical functioning, emotional and cognitive well-being, and social functioning at 2, 7, and 12 months after transplant (response rate = 95%). Ninety patients who had not received VADs--matched to the VAD group on cardiac-related and sociodemographic characteristics--served as longitudinal controls. RESULTS: Both VAD and non-VAD groups showed similar levels and similar, statistically significant (p < 0.05) improvement in physical functioning (sleep, body care, mobility, ambulation, overall functional status, number of somatic complaints) across the study period. Emotional well-being (elevated depressive, anxiety, and anger symptoms; post-traumatic stress disorder rate) was stable or improved in both groups, and VAD patients showed significantly lower anxiety rates. The VAD patients' post-transplant cognitive status was significantly poorer. The VAD patients were significantly less likely to return to employment; other social functioning measurers (daily concerns, interpersonal activities/involvement, role function) showed mixed effects. Cognitive impairment explained much of the association between VAD support and post-transplant employment. CONCLUSIONS: Although post-transplant physical and emotional recovery is similar in VAD and non-VAD patients, VAD patients retain more cognitive impairment and show mixed changes in social functioning. Increased attention to strategies to maximize VAD patients' cognitive capacity is required to facilitate social reintegration.


Asunto(s)
Trasplante de Corazón , Corazón Auxiliar , Calidad de Vida , Cognición , Emociones , Empleo , Estado de Salud , Humanos , Relaciones Interpersonales , Estudios Longitudinales
7.
Artif Organs ; 25(9): 724-7, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11722350

RESUMEN

We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV-Ao) bypass, and parameters were recorded at different pump speeds under general anesthesia. Pump inflow and outflow pressure, arterial pressure, systemic and pulmonary blood flow, and electrocardiogram (ECG) were recorded on the computer every 5 ms. All parameters were separated into systolic and diastolic components and analyzed. The pulmonary flow was the same as the systemic flow during the study (p > 0.1). Systemic flow consisted of pump flow and LV output through the aortic valve. The ratio of systolic pump flow to pulmonary flow (51.3%) did not change significantly at variable pump speeds (p > 0.1). The other portions of the systemic flow were shared by the left ventricular output and the pump flow during diastole. When pump flow increased during diastole, there was a corresponding decrease in the LV output (Y = -1.068X + 51.462; R(insert)(2) = 0.9501). These show that pump diastolic flow may regulate expansion of the left ventricle in diastole.


Asunto(s)
Diástole/fisiología , Corazón Auxiliar , Análisis de Varianza , Animales , Velocidad del Flujo Sanguíneo/fisiología , Bovinos , Centrifugación , Hemodinámica/fisiología , Hemorreología , Función Ventricular Izquierda/fisiología
8.
Ann Thorac Surg ; 72(4): 1380-2, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11603472

RESUMEN

This report describes the case of a 51-year-old man with myocardial ischemia resulting from in-stent restenosis of the left anterior descending coronary artery who underwent a minimally invasive direct coronary artery bypass using thoracic epidural analgesia while awake, without general endotracheal anesthesia.


Asunto(s)
Anestesia Epidural , Puente de Arteria Coronaria , Oclusión de Injerto Vascular/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos , Stents , Anestesia Endotraqueal , Humanos , Masculino , Persona de Mediana Edad , Reoperación
9.
Circulation ; 104(12 Suppl 1): I81-4, 2001 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-11568035

RESUMEN

BACKGROUND: Although transmyocardial laser revascularization (TMR) has provided symptomatic relief of angina over the short term, the long-term efficacy of the procedure is unknown. Angina symptoms as assessed independently by angina class and the Seattle Angina Questionnaire (SAQ) were prospectively collected up to 7 years after TMR. METHODS: Seventy-eight patients with severe angina not amenable to conventional revascularization were treated with a CO(2) laser. Their mean age was 61+/-10 years at the time of treatment. Preoperatively, 66% had unstable angina, 73% had had >/=1 myocardial infarction, 93% had undergone >/=1 CABG, 42% had >/=1 PTCA, 76% were in angina class IV, and 24% were in angina class III. Their average pre-TMR angina class was 3.7+/-0.4. RESULTS: After an average of 5 years (and up to 7 years) of follow-up, the average angina class was significantly improved to 1.6+/-1 (P=0.0001). This was unchanged from the 1.5+/-1 average angina class at 1 year postoperatively (P=NS). There was a marked redistribution according to angina class, with 81% of the patients in class II or better, and 17% of the patients had no angina 5 years after TMR. A decrease of >/=2 angina classes was considered significant, and by this criterion, 68% of the patients had successful long-term angina relief. The angina class results were further confirmed with the SAQ; 5-year SAQ scores revealed an average improvement of 170% over the baseline results. CONCLUSIONS: The long-term efficacy of TMR persists for >/=5 years. TMR with CO(2) laser as sole therapy for severe disabling angina provides significant long-term angina relief.


Asunto(s)
Angina de Pecho/cirugía , Terapia por Láser , Revascularización Miocárdica/instrumentación , Revascularización Miocárdica/métodos , Adulto , Anciano , Anciano de 80 o más Años , Angina de Pecho/clasificación , Femenino , Estudios de Seguimiento , Humanos , Terapia por Láser/instrumentación , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Inducción de Remisión , Encuestas y Cuestionarios , Tiempo , Resultado del Tratamiento
10.
Circulation ; 104(8): 934-8, 2001 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-11514382

RESUMEN

BACKGROUND: Acute cardiac allograft rejection continues to be the cause of graft loss and contributes to the morbidity and mortality after cardiac transplantation. In this study, we report a new method for detecting organ rejection in transplantation with an MR-based technique using dextran-coated ultrasmall superparamagnetic iron oxide (USPIO) particles. These particles ( approximately 27 nm in diameter) are known to shorten relaxation times in MRI experiments. METHODS AND RESULTS: A new rat model of heterotopic heart and lung transplantation has been developed for MRI experiments. Allotransplantations (DA-->BN) were performed (n=8), with syngeneic transplantations (BN-->BN) serving as controls (n=8). MR images were obtained with a gradient echo method. At postoperative day 7, allotransplants developed moderate rejection as determined histopathologically. A significant reduction in MR signal intensity was observed after USPIO injection into rats with allotransplanted hearts. Syngeneic transplants showed no differences in MR signal intensity before and after USPIO injections. After injection of USPIO particles at postoperative day 6, a group of allotransplanted rats was treated with cyclosporin A (3 mg/kg). Animals treated with cyclosporin A for 7 days showed no reduction in MR signal intensity after USPIO reinjection at day 14, whereas animals treated for 4 days showed a significant decrease in MR signal intensity in the transplanted hearts indicative of acute graft rejection. Pathological analysis of these animals revealed that dextran-coated USPIO particles were taken up by the infiltrating macrophages that accumulated within the rejecting cardiac graft. CONCLUSIONS: This MRI method offers promise as a noninvasive method for detecting transplant allograft rejection.


Asunto(s)
Compuestos Férricos/metabolismo , Rechazo de Injerto/diagnóstico , Macrófagos/metabolismo , Imagen por Resonancia Magnética/métodos , Miocardio/metabolismo , Animales , Recuento de Células , Ciclosporina/farmacología , Dextranos/química , Modelos Animales de Enfermedad , Espectroscopía de Resonancia por Spin del Electrón , Compuestos Férricos/análisis , Compuestos Férricos/química , Rechazo de Injerto/etiología , Rechazo de Injerto/inmunología , Rechazo de Injerto/prevención & control , Trasplante de Corazón/efectos adversos , Trasplante de Corazón/inmunología , Inmunohistoquímica , Trasplante de Pulmón/efectos adversos , Trasplante de Pulmón/inmunología , Macrófagos/inmunología , Macrófagos/patología , Masculino , Microesferas , Miocardio/patología , Tamaño de la Partícula , Valor Predictivo de las Pruebas , Ratas , Ratas Endogámicas BN , Sensibilidad y Especificidad
11.
Psychosomatics ; 42(4): 300-13, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11496019

RESUMEN

Although poor psychological adjustment to organ transplantation appears to be a major contributor to reduced quality of life and increased physical morbidity, the prevalence and risk factors for psychiatric disorder have not been considered beyond the first 12-18 months after transplantation. The authors enrolled a representative sample of 191 heart transplant recipients in a prospective examination of the prevalence, clinical characteristics, and risk factors for DSM-III-R major depressive disorder (MDD), generalized anxiety disorder (GAD), associated adjustment disorders, and posttraumatic stress disorder related to transplant (PTSD-T) during the 3 years postsurgery. Survival analysis indicates that cumulative risks for disorder onset were MDD, 25.5%; adjustment disorders, 20.8% (17.7% with anxious mood); PTSD-T, 17.0%; and any assessed disorder, 38.3%. There was only one case of GAD. PTSD-T onset was limited almost exclusively to the first year posttransplant. Episodes of MDD (but not anxiety disorders) that occurred later posttransplant (8 to 36 months postsurgery) were more likely than early posttransplant episodes to be treated with psychotropic medications. For both MDD and anxiety disorders, later episodes were less likely to be precipitated by transplant-related stressors than other life stressors. Factors increasing cumulative risk for psychiatric disorder posttransplant included pretransplant psychiatric history, female gender, longer hospitalization, more impaired physical functional status, and lower social supports from caregiver and family in the perioperative period. Risk factors' effects were additive; the presence of an increasing number of risk factors bore a dose-response relationship to cumulative risk of disorder.


Asunto(s)
Trastornos de Ansiedad/psicología , Trastorno Depresivo Mayor/psicología , Trasplante de Corazón/psicología , Complicaciones Posoperatorias/psicología , Adolescente , Adulto , Trastornos de Ansiedad/diagnóstico , Trastornos de Ansiedad/epidemiología , Estudios Transversales , Trastorno Depresivo Mayor/diagnóstico , Trastorno Depresivo Mayor/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Escalas de Valoración Psiquiátrica , Factores de Riesgo
12.
Ann Thorac Surg ; 71(5): 1491-5, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11383788

RESUMEN

BACKGROUND: This study identified and compared the prevalence of new-onset atrial fibrillation (AFIB) following standard coronary artery bypass grafting (SCABG) with cardiopulmonary bypass (CPB) and minimally invasive direct vision coronary artery bypass grafting (MIDCAB) without CPB. A further comparison was made between AFIB prevalence in SCABG and MIDCAB subjects with two or fewer bypasses. METHODS: This is a retrospective, comparative survey. Patients with new-onset AFIB who underwent SCABG or MIDCAB alone were identified electronically using a triangulated method (International Classification of Diseases, 9th revision, Clinical Modification [ICD-9 CM] code; clinical database word search; and pharmacy database drug search). RESULTS: The total sample (n = 814; 94 MIDCAB, 720 SCABG) exhibited a trend toward lower AFIB prevalence in MIDCAB (23.4%) versus SCABG (33.1%) subjects (p = 0.059). AFIB prevalence in the SCABG subset with two or less vessel bypasses (n = 98; n = 18 single vessel, n = 80 double vessels) and MIDCAB subjects (n = 94; n = 90 single vessels, n = 4 double vessels) was almost identical (SCABG subset 24.5% versus MIDCAB 23.4%, p = 0.860). Slightly more than half (56.9%) of new-onset AFIB subjects were identified by ICD-9 CM codes, with the remainder by word search (37.7%) or procainamide query (5.4%). CONCLUSIONS: In this sample, the number of vessels bypassed seemed to have a greater influence on AFIB prevalence than the application of CPB or the surgical approach. Retrospective identification of AFIB cases by ICD-9 CM code grossly underestimated AFIB prevalence.


Asunto(s)
Fibrilación Atrial/epidemiología , Puente de Arteria Coronaria , Procedimientos Quirúrgicos Mínimamente Invasivos , Complicaciones Posoperatorias/epidemiología , Anciano , Fibrilación Atrial/etiología , Estudios Transversales , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Pennsylvania , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo
13.
J Heart Lung Transplant ; 20(6): 625-30, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11404167

RESUMEN

BACKGROUND: Cytokines play a major role in the inflammatory and immune responses that mediate allograft outcome. Several studies have shown that the production of cytokines varies among individuals and these variations are determined by genetic polymorphisms, most commonly within the regulatory region of the cytokine gene. The aim of this study was to assess the effect of these allelic variations on acute rejection after pediatric heart transplantation. METHODS: We performed cytokine genotyping using polymerase chain reaction-sequence specific primers in 93 pediatric heart transplant recipients and 29 heart donors for the following functional polymorphisms: tumor necrosis factor-alpha (TNF-alpha) (-308), interleukin (IL)-10 (-1082, -819, and -592), TGF-beta1 (codon 10 and 25), IL-6 (-174), and interferon-gamma (INF-gamma) (+874). The distribution of polymorphisms in this population did not differ from published controls. The patients were classified as either non-rejecters (0 or 1 episode) or rejecters (> 1 episode) based on the number of biopsy proven rejection episodes in the first year after transplantation. RESULTS: Forty-two of the 69 TNF-alpha patients (61%) in the low producer group were non-rejecters, while 9 of the 24 (37.5%) with high TNF-alpha were non-rejecters (p = 0.047). In contrast, IL-10 genotype showed the opposite finding. Forty-two of the 66 patients (64%) in the high and intermediate IL-10 group were non-rejecters, while 9 of the 26 (35%) in the low IL-10 group were non-rejecters (p = 0.011). The combination of low TNF-alpha with a high or intermediate IL-10 genotype was associated with the lowest risk of rejection (34/49 or 69% non-rejecters). Neither the distribution of the IL-6, INF-gamma, and TGF-beta1 genotype in recipients nor the donor genotype showed any association with acute rejection. CONCLUSION: Genetic polymorphisms that have been associated with low TNF-alpha and high IL-10 production are associated with a lower number of acute rejection episodes after pediatric heart transplantation.


Asunto(s)
Citocinas/genética , Rechazo de Injerto/genética , Trasplante de Corazón , Polimorfismo Genético/genética , Adolescente , Niño , Supervivencia de Injerto/genética , Humanos , Pronóstico
14.
J Heart Lung Transplant ; 20(3): 297-303, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11257555

RESUMEN

BACKGROUND: Patients surviving into adulthood with congenital heart disease (CHD) often succumb to progressive cardiopulmonary dysfunction. For these patients transplantation is often considered. METHODS: We performed a retrospective review of 69 adults (age >18 years) with CHD transplanted between 1984 and 1999. RESULTS: We evaluated 31 heart-lung (HLTxp), 30 lung (LTxp), and 8 heart (HTxp) transplants performed in 22 men and 47 women with CHD. Mean age was 37 +/- 10 years with a mean follow-up of 3.1 +/- 3.5 years. A concomitant cardiovascular procedure was performed in 1 HLTxp, 23 LTxp, and 2 HTxp. Early mortality (>30 days) was 26% (8/31) for HLTxp, mostly due to bleeding. Early LTxp mortality was 23% (7/30), largely due to graft failure. One and 3-year survival was similar in adults transplanted for CHD and adults transplanted for other disease. Early mortality among HTxp recipients was 50% (4/8) from rejection or technical complications. Survival for patients undergoing HLTxp versus LTxp with cardiac repair was similar. When examined by era, the survival of patients transplanted for CHD between 1992 and 1999 was greater than that of patients transplanted between 1984 and 1991. CONCLUSIONS: Adults undergoing HLTxp and LTxp for CHD can expect survival comparable to that of non-CHD adults. In the presence of a reparable cardiac lesion, LTxp with cardiovascular repair for CHD is an attractive option, optimizing organ allocation. Specific technical concerns are discussed. Survival of adults undergoing cardiopulmonary transplantation for CHD has improved over time.


Asunto(s)
Cardiopatías Congénitas/cirugía , Trasplante de Corazón , Trasplante de Corazón-Pulmón , Trasplante de Pulmón , Adulto , Trasplante de Corazón/mortalidad , Trasplante de Corazón-Pulmón/mortalidad , Humanos , Trasplante de Pulmón/mortalidad , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos
18.
Ann Thorac Surg ; 71(3 Suppl): S116-20; discussion S114-6, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11265845

RESUMEN

The HeartMate II left ventricular assist device (LVAD) (ThermoCardiosystems, Inc, Woburn, MA) has evolved from 1991 when a partnership was struck between the McGowan Center of the University of Pittsburgh and Nimbus Company. Early iterations were conceptually based on axial-flow mini-pumps (Hemopump) and began with purge bearings. As the project developed, so did the understanding of new bearings, computational fluid design and flow visualization, and speed control algorithms. The acquisition of Nimbus by ThermoCardiosystems, Inc (TCI) sped developments of cannulas, controller, and power/monitor units. The system has been successfully tested in more than 40 calves since 1997 and the first human implant occurred in July 2000. Multicenter safety and feasibility trials are planned for Europe and soon thereafter a trial will be started in the United States to test 6-month survival in end-stage heart failure.


Asunto(s)
Corazón Auxiliar , Diseño de Equipo , Humanos , Presión
19.
Transplantation ; 71(2): 252-6, 2001 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-11213069

RESUMEN

BACKGROUND: Posttransplantation diabetes mellitus (PTDM) is a well-known complication of tacrolimus-based immunosuppression in both adult and pediatric solid organ recipients. The "natural history" of diabetes in the pediatric thoracic transplant population has not yet been described. METHODS: We identified all pediatric thoracic transplant patients receiving tacrolimus-based immunosuppression who developed PTDM. Medical records were reviewed, with a particular focus on the clinical course of PTDM and its relationship to drug weaning. RESULTS: Diabetes developed in 24 of 143 (17%) 30-day survivors of heart (12/96, 13%) and heart-lung/lung (12/ 47, 26%) transplantation. In 17 (71%) patients, the immunosuppressive regimen at the onset of PTDM also included maintenance corticosteroids. Seventeen patients demonstrated glucose intolerance before the onset of diabetes. Nine patients (38%) developed diabetes during pulsed corticosteroid therapy. Median time of onset after transplantation was 9.0 months. All patients required s.c. insulin for glucose control. The median follow-up from transplant was 49.9 months. There was a significant decrease in mean tacrolimus dosage (P<0.01), tacrolimus level (P<0.04), and steroid dosage (P<0.02) from onset of PTDM to most recent follow-up. Despite this significant reduction in immunosuppression, only 3/24 (13%) patients were successfully weaned off insulin. CONCLUSIONS: Diabetes mellitus is a common complication in pediatric thoracic transplant patients receiving tacrolimus-based immunosuppression. Insulin dependence in our population rarely resolved, even after lowering tacrolimus and steroid doses. Discontinuation of steroids did not guarantee resolution of diabetes.


Asunto(s)
Diabetes Mellitus/etiología , Trasplante de Corazón/efectos adversos , Trasplante de Corazón-Pulmón/efectos adversos , Inmunosupresores/uso terapéutico , Trasplante de Pulmón/efectos adversos , Tacrolimus/uso terapéutico , Tórax/trasplante , Adolescente , Niño , Diabetes Mellitus/epidemiología , Progresión de la Enfermedad , Humanos , Masculino , Tórax/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA