Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Ann Med Surg (Lond) ; 86(8): 4368-4376, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39118698

RESUMEN

Background: Data on racial/ethnic and sex disparities in the utilization and outcomes of tricuspid valve surgery (TVS) in the United States are scarce. The authors aimed to evaluate the impact of race/ethnicity and sex on the utilization and outcomes of TVS. Methods: The authors analyzed the National Inpatient Sample database from 2016 to 2020 to identify hospitalizations for TVS. Racial/ethnic and sex disparities in TVS outcomes were determined using logistic regression models. Results: Between 2016 and 2020, 19 395 hospitalizations for TVS were identified. The utilization rate (number of surgeries/100,000 hospitalizations) was lower in Black and Hispanic patients compared with White patients for surgical tricuspid valve repair (STVr) (331 versus 493 versus 634, P<0.01) and surgical tricuspid valve replacement (STVR) (312 versus 601 versus 728, P<0.01). Similarly, the utilization rate was lower for women compared with men for STVr (1021 versus 1364, P<0.01) and STVR (930 versus 1,316, P<0.01). Compared to White men undergoing TVS, all women had lower odds of acute kidney injury [adjusted odds ratio (aOR) 0.65, 95% CI 0.55-0.78] and higher odds of blood transfusion (aOR 1.30, 95% CI 1.07-1.59), and Black men had higher odds of blood transfusion (aOR 1.59, 95% CI 1.08-2.35). In-hospital mortality and other surgical complications were similar between all groups (all P>0.05). Conclusions: Significant racial/ethnic and sex disparities exist in the utilization of TVS in the United States. Further studies are needed to understand the reasons for these disparities and to identify effective strategies for their mitigation.

2.
Circulation ; 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-39101203

RESUMEN

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year (P<0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4-8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital (P=0.0005), 30-day (P=0.004), and 1-year mortality rates (P=0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.

3.
J Soc Cardiovasc Angiogr Interv ; 3(6): 101936, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39132585

RESUMEN

Background: Intracoronary imaging-guided percutaneous coronary intervention (PCI) is associated with improved outcomes compared with angiography-guided PCI. Data on racial/ethnic, sex, and economic disparities in the utilization and outcomes of intracoronary imaging in the United States are scarce. Methods: We analyzed the National Inpatient Sample (2016-2020) to examine racial/ethnic, sex, and economic differences in the utilization of intracoronary imaging among patients who underwent PCI. Trends, in-hospital mortality, and safety of intracoronary imaging were also assessed. Results: Among 2,212,595 weighted hospitalizations for PCI, 204,735 (9.2%) included intracoronary imaging. The utilization rate of intracoronary imaging was similar in Black and Hispanic patients compared with White patients (9.8% vs 10.2% vs 10.0%; P = .68) and lower for women compared with men (10.0% vs 10.3%; P = .01) and for patients with low and medium income compared with high income (9.2% vs 10.0% vs 12.5%; P < .01). In multivariable regression analysis, low and medium income were independently associated with lower intracoronary imaging use compared with high income (both P < .01). From 2016 through 2020, the use of intracoronary imaging in PCI increased significantly in all racial/ethnic, sex, and economic groups (all P trend < .01). Among patients who underwent PCI with intracoronary imaging, Black race was associated with higher odds of acute kidney injury compared with White race (adjusted odds ratio, 1.40; 95% CI, 1.25-1.57). In-hospital mortality was similar between different racial/ethnic, sex, and economic groups. Conclusions: Low and medium income are independently associated with lower intracoronary imaging use in PCI compared with high income. Further studies are needed to identify effective strategies to mitigate economic disparities in intracoronary imaging use.

4.
JACC Adv ; 3(7): 101034, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39130026

RESUMEN

Background: Disparities in access to care cause negative health consequences for underserved populations. Economic disparities in structural heart disease (SHD) interventions are not well characterized. Objectives: The objective of this study was to evaluate economic disparities in the utilization and outcomes of SHD interventions in the United States. Methods: We queried the National Inpatient Sample (2016-2020) to examine economic disparities in the utilization, in-hospital outcomes, length of stay, and cost of SHD interventions among patients ≥65 years of age. Outcomes were determined using logistic regression models. Results: A total of 401,005 weighted hospitalizations for transcatheter aortic valve replacement, left atrial appendage occlusion, transcatheter mitral valve repair, and transcatheter mitral valve replacement were included. Utilization rates (number of procedures performed per 100,000 hospitalizations) were higher in patients with high income compared with medium and low income for transcatheter aortic valve replacement (559 vs 456 vs 338), left atrial appendage occlusion (148 vs 136 vs 99), transcatheter mitral valve repair (65 vs 54 vs 41), and transcatheter mitral valve replacement (7.7 vs 6.7 vs 1.2) (all P < 0.01). Low- and medium-income patients had distinctive demographic and clinical risk profiles compared with high-income patients. There were no significant differences in the adjusted in-hospital mortality, key complications, or length of stay between high-, medium-, and low-income patients following any of the 4 SHD interventions. High-income patients incurred a modestly higher cost with any of the 4 SHD interventions compared with medium- and low-income patients. Conclusions: Economic disparities exist in the utilization of SHD interventions in the United States. Nonetheless, adjusted in-hospital outcomes were comparable among high-, medium-, and low-income patients. Multifaceted implementation strategies are needed to attenuate these utilization disparities.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39030048

RESUMEN

BACKGROUND: A significant proportion of patients requiring mitral valve (MV) intervention have undergone prior coronary artery bypass grafting (CABG). Reoperative heart surgery is associated with increased risk. AIMS: To evaluate the utilization and outcomes of transcatheter versus surgical MV interventions in patients with prior CABG. METHODS: We queried the Nationwide Readmission Database (2016-2021) to identify adults with prior CABG hospitalized for transcatheter or surgical MV intervention. In-hospital outcomes were compared using multivariable regression and propensity-matching analyses. Readmissions were compared using Cox proportional hazards regression model. RESULTS: Of 305,625 weighted hospitalizations for MV intervention, 23,506 (7.7%) occurred in patients with prior CABG. From 2016-2021, the use of transcatheter MV interventions increased among patients with prior CABG (72 to 191 for repair and 6 to 45 for replacement per 100,000 hospitalizations, both ptrend<0.001). Compared with surgical MV repair and replacement, transcatheter MV repair and replacement were associated with similar in-hospital mortality (adjusted odds ratio [aOR] 0.44, 95% confidence interval [CI] 0.20-1.03 for repair; aOR 0.61, 95% CI 0.38-1.02 for replacement) and 180-day heart failure readmissions (adjusted hazard ratio [aHR] 1.56, 95% CI 0.85-2.87 for repair; aHR 1.15, 95% CI 0.63-2.09 for replacement) and lower stroke, acute kidney injury, permanent pacemaker placement, length of stay, and nonhome discharges, respectively. Vascular complications were higher with transcatheter versus surgical MV replacement. CONCLUSIONS: Transcatheter MV interventions are increasingly used as the preferred modality of MV intervention in patients with prior CABG and are associated with similar in-hospital mortality and 180-day heart failure readmissions compared with surgical MV interventions.

6.
JACC Cardiovasc Interv ; 17(13): 1577-1590, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38986657

RESUMEN

BACKGROUND: Mitral annular calcification (MAC) is a progressive degenerative process associated with comorbidities and increased mortality. A staging system that considers extramitral cardiac damage in MAC may help improve patient selection for mitral valve interventions. OBJECTIVES: This study sought to develop a transthoracic echocardiogram (TTE)-based cardiac staging system in patients with MAC and significant mitral valve dysfunction and assess its prognostic utility. METHODS: We retrospectively evaluated all adults who underwent TTE over 1 year at Mayo Clinic with MAC and significant mitral valve dysfunction defined as mitral stenosis and/or at least moderate mitral regurgitation. Patients were categorized into 5 stages according to extramitral cardiac damage by TTE. All-cause mortality and heart failure hospitalization were assessed. RESULTS: For the 953 included patients, the mean age was 76.2 ± 10.7 years, and 54.0% were women. Twenty-eight (2.9%) patients were classified in stages 0 to 1, 499 (52.4%) in stage 2, 115 (12.1%) in stage 3, and 311 (32.6%) in stage 4. At the 3.8-year follow-up, mortality was significantly higher in patients in stages 2 to 4 compared to stages 0 to 1 and increased with each stage. Survival differences were maintained after adjustment for age, diabetes mellitus, and glomerular filtration rate. The rate of heart failure hospitalization was significantly higher in stages 3 and 4 compared to stages 0 to 1. Similar results were observed in subgroup analysis in patients with moderate or severe MAC, predominant mitral stenosis, or predominant mitral regurgitation. CONCLUSIONS: Using the proposed extramitral cardiac damage staging system in patients with MAC and significant mitral valve dysfunction, more advanced stages are associated with higher mortality.


Asunto(s)
Calcinosis , Insuficiencia Cardíaca , Insuficiencia de la Válvula Mitral , Estenosis de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Femenino , Masculino , Anciano , Estudios Retrospectivos , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/mortalidad , Calcinosis/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Factores de Tiempo , Anciano de 80 o más Años , Factores de Riesgo , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/etiología , Persona de Mediana Edad , Minnesota , Medición de Riesgo , Pronóstico , Ecocardiografía
7.
EuroIntervention ; 20(14): e887-e897, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39007829

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is a therapeutic option for patients with severe mitral regurgitation (MR) who are ineligible for conventional surgery. There are limited data on the outcomes of large patient cohorts treated with TMVR. AIMS: This study aimed to investigate the outcomes and predictors of mortality for patients treated with transapical TMVR. METHODS: This analysis represents the clinical experience of all patients enrolled in the Tendyne Expanded Clinical Study. Patients with symptomatic MR underwent transapical TMVR with the Tendyne system between November 2014 and June 2020. Outcomes and adverse events up to 2 years, as well as predictors of short-term mortality, were assessed. RESULTS: A total of 191 patients were treated (74.1±8.0 years, 62.8% male, Society of Thoracic Surgeons Predicted Risk of Mortality 7.7±6.6%). Technical success was achieved in 96.9% (185/191), and there were no intraprocedural deaths. At 30-day, 1- and 2-year follow-up, the rates of all-cause mortality were 7.9%, 30.8% and 40.5%, respectively. Complete MR elimination (MR <1+) was observed in 99.3%, 99.1% and 96.3% of patients, respectively. TMVR treatment resulted in consistent improvement of New York Heart Association Functional Class and quality of life up to 2 years (both p<0.001). Independent predictors of early mortality were age (odds ratio [OR] 1.11; p=0.003), pulmonary hypertension (OR 3.83; p=0.007), and institutional experience (OR 0.40; p=0.047). CONCLUSIONS: This study investigated clinical outcomes in the full cohort of patients included in the Tendyne Expanded Clinical Study. The Tendyne TMVR system successfully eliminated MR with no intraprocedural deaths, resulting in an improvement in symptoms and quality of life. Continued refinement of clinical and echocardiographic risks will be important to optimise longitudinal outcomes.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/mortalidad , Masculino , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Anciano , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Anciano de 80 o más Años , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Prótesis Valvulares Cardíacas , Factores de Riesgo , Persona de Mediana Edad
8.
Circ Cardiovasc Interv ; : e013782, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39034924

RESUMEN

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.

9.
J Cardiol ; 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38762190

RESUMEN

BACKGROUND: Secondary mitral regurgitation (MR) worsens in 10-15 % of heart failure (HF) patients receiving cardiac resynchronization therapy (CRT). Transcatheter edge-to-edge repair (TEER) with Mitra-Clip (Abbot Vascular, Santa Clara, CA, USA) therapy is associated with improved survival and decreased rates of hospitalization for HF in selected patients with secondary MR. Data on TEER outcomes in CRT-non-responders are limited. The purpose of this meta-analysis was to evaluate outcomes of mitral TEER with Mitra-Clip in CRT-non-responders. METHODS: Cochrane, Scopus, MEDLINE, and EMBASE were searched for studies discussing outcomes of Mitra-Clip in CRT non-responders. Two reviewers were independently involved in screening studies and extracting relevant data. Individual study incidence rate estimates underwent logit transformation to calculate the weighted summary proportion under the random effect model. RESULTS: A total of eight reports met the inclusion criteria (439 patients). Mitra-Clip improved MR grade to ≤2+ in 83.8 % and 86.8 % of CRT non-responders at six months and one year, respectively. Symptomatic improvement (New York Heart Association class ≤II) was also found in 71 % and 78.1 % of CRT non-responders at six months and one year, respectively. The pooled overall incidence estimates of mortality at 30 days, 6 months, 1 year, and 2 years were 3.6 %, 9.2 %, 17.8 %, and 25.9 %, respectively. CONCLUSION: TEER with Mitra-Clip in patients with significant secondary MR who do not respond to CRT was associated with MR improvement, alleviation of symptoms, and mortality rates similar to those in the COAPT trial.

10.
J Am Heart Assoc ; 13(9): e032553, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38700034

RESUMEN

BACKGROUND: Previous studies have shown that women with hypertrophic obstructive cardiomyopathy (HCM) have worse long-term outcomes irrespective of intervention. However, the outcomes of patients undergoing alcohol septal ablation (ASA) based on sex have not been described. Hence, this study aimed to evaluate pressure changes and long-term mortality in patients with HCM undergoing ASA based on sex. METHODS AND RESULTS: This is a single-center retrospective study evaluating hemodynamic changes and long-term mortality in patients with HCM treated with ASA according to sex. A total of 259 patients were included (aged 68.4±11.9 years, 62.2% women). Women had higher age and baseline pressures at the time of ASA, with a greater percent reduction in mean left atrial pressure (men versus women: 2.2% versus 15.9%, respectively; P=0.02). Women had better survival (median survival rate of men versus women: 8.6 versus 12.5 years, respectively; P=0.011). On Cox multivariable regression, predictors of mortality were age (per group change <60 years, 61-70 years, 71-80 years, and >80 years; hazard ratio [HR], 1.45 [95% CI, 1.10-1.91], P=0.008), female sex (HR, 0.59 [95% CI, 0.35-0.99], P=0.048), chronic kidney disease (HR, 1.88 [95% CI, 1.06-3.33], P=0.031), and left ventricular outflow tract gradient reduction ≤86% (HR, 1.91 [95% CI, 1.14-3.19], P=0.014). CONCLUSIONS: Women with HCM undergoing ASA are older and have higher left-sided baseline pressures compared with men yet have better survival. Further studies exploring the mechanisms of differential outcomes according to sex in patients with HCM undergoing ASA are needed.


Asunto(s)
Técnicas de Ablación , Cardiomiopatía Hipertrófica , Etanol , Humanos , Cardiomiopatía Hipertrófica/cirugía , Cardiomiopatía Hipertrófica/mortalidad , Cardiomiopatía Hipertrófica/fisiopatología , Cardiomiopatía Hipertrófica/complicaciones , Femenino , Masculino , Anciano , Estudios Retrospectivos , Etanol/efectos adversos , Persona de Mediana Edad , Factores Sexuales , Técnicas de Ablación/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Tabiques Cardíacos/cirugía , Factores de Riesgo , Factores de Tiempo , Factores de Edad
11.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38587261

RESUMEN

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Bioprótesis/efectos adversos , Insuficiencia Cardíaca , Estimación de Kaplan-Meier , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Falla de Prótesis , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
12.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599690

RESUMEN

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Cateterismo Cardíaco/métodos
13.
J Am Soc Echocardiogr ; 37(8): 752-755, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38493834

RESUMEN

BACKGROUND: Mitral annulus calcification (MAC) represents a degenerative process resulting in calcium deposition in the mitral valve apparatus. Mitral annulus calcification is associated with adverse clinical outcomes. We sought to examine the long-term significance of mild MAC and its relationship to subsequent mitral valve dysfunction (MVD) and mortality in patients without MVD on the initial echocardiogram. METHODS: A total of 1,420 patients with mild MAC and no MVD at baseline and 1 or more follow-up echocardiograms at least 1 year after the baseline echocardiogram were included in the analysis. For patients with >1 echocardiogram during follow-up, the last echocardiogram was used. The same criteria were used to identify 6,496 patients without MAC. Mitral valve dysfunction was defined as mitral regurgitation (MR) and/or mitral stenosis (MS) of moderate or greater severity. Mixed disease was defined as the concurrent presence of both moderate or greater MS and MR. The primary end point was development of MVD, and the secondary end point was all-cause mortality. RESULTS: For patients with mild MAC, age was 74 ± 10 years and 528 (37%) were female. Over a median follow-up of 4.7 (interquartile range, 2.7-6.9) years, 215 patients with mild MAC developed MVD, including MR in 170 (79%), MS in 37 (17%), and mixed disease in 8 (4%). In a multivariable regression model compared to patients without MAC, the presence of mild MAC was independently associated with increased mortality (hazard ratio = 1.43; 95% CI 1.24, 1.66; P < .001). Kaplan-Meier 4-year survival rates were 80% and 90% for patients with mild MAC and no MAC, respectively. CONCLUSIONS: Mild MAC observed on transthoracic echocardiography is an important clinical finding with prognostic implications for both valvular function and mortality.


Asunto(s)
Calcinosis , Progresión de la Enfermedad , Ecocardiografía , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Femenino , Masculino , Calcinosis/diagnóstico por imagen , Calcinosis/complicaciones , Anciano , Válvula Mitral/diagnóstico por imagen , Ecocardiografía/métodos , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/complicaciones , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/fisiopatología , Tasa de Supervivencia , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Estudios de Seguimiento , Factores de Riesgo
15.
J Am Soc Echocardiogr ; 37(5): 530-537, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38341053

RESUMEN

BACKGROUND: Data on the prognostic factors after mitral valve (MV) transcatheter edge-to-edge repair (TEER; MV-TEER) are limited. Pulsed-wave Doppler interrogation of pulmonary vein flow (PVF) is a convenient method to assess the hemodynamic burden of residual mitral regurgitation (MR), which could be of utility as a predictor of outcomes. METHODS: Patients that underwent MV-TEER between May 2014 and December 2021 at our institution were evaluated. Pulmonary vein flow patterns post-MV-TEER were reviewed on the procedural transesophageal echocardiogram and classified as normal (systolic dominant or codominant) or abnormal (systolic blunting or reversal). The PVF pattern was correlated with all-cause mortality at follow-up. RESULTS: Two-hundred sixty-five patients had diagnostic PVF post-MV-TEER, with 73 (27.5%) categorized as normal and 192 (72.5%) categorized as abnormal. Patients with abnormal PVF morphology were more likely to have atrial fibrillation (70% vs 42%, P < .001) and greater than moderate residual MR (16% vs 3%, P = .01) and had higher mean left atrial pressure (18.1 ± 5.0 vs 15.9 ± 4.2 mm Hg, P = .002) and left atrial V wave (26.6 ± 8.5 vs 21.4 ± 7.3 mm Hg, P < .001) postprocedure. In multivariable analysis, abnormal PVF morphology post-MV-TEER was independently associated with mortality at follow-up (hazard ratio = 1.70; 95% CI, 1.06-2.74; P = .03) after correction for end-stage renal disease, atrial fibrillation, and residual MR. Results were similar in subgroups of patients with moderate or less and those with mild or less residual MR. CONCLUSIONS: Pulmonary vein flow morphology is a simple and objective tool to assess MR severity immediately post-MV-TEER and offers important prognostic information to optimize procedural results. Additional studies are needed to determine whether patients with abnormal PVF pattern post-MV-TEER would benefit from more intensive goal-directed medical therapy postprocedure.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Transesofágica , Insuficiencia de la Válvula Mitral , Válvula Mitral , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Femenino , Insuficiencia de la Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anciano , Ecocardiografía Transesofágica/métodos , Cateterismo Cardíaco/métodos , Estudios Retrospectivos , Tasa de Supervivencia , Pronóstico , Ecocardiografía Doppler de Pulso/métodos
16.
J Am Heart Assoc ; 13(3): e030540, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38240203

RESUMEN

BACKGROUND: Aortic valve calcium score is associated with hemodynamic severity of aortic stenosis. Whether this association is present in calcific mitral stenosis remains unknown. METHODS AND RESULTS: This study was a retrospective analysis of consecutive patients with mitral stenosis secondary to mitral annular calcification (MAC) undergoing transseptal catheterization. All patients underwent invasive mitral valve assessment via direct left atrial and left ventricular pressure measurement. Computed tomography within 1 year of cardiac catheterization and with adequate visualization of the mitral annulus was included. MAC calcium score quantification by Agatston method was obtained offline using dedicated software (Aquarius, TeraRecon, V.4). Median patient age was 66.9±11.2 years, 47% of patients were women, 50% had coronary artery disease, 40% had atrial fibrillation, 47% had prior cardiac surgery, and 33% had prior chest radiation. Median diastolic mitral valve gradient was 9.4±3.4 mm Hg on echocardiography and 8.5±4 mm Hg invasively. Invasive median mitral valve area using the Gorlin formula was 1.87±0.9 cm2. Median MAC calcium score for the cohort was 7280±7937 Hounsfield units. MAC calcium score correlated with the presence of atrial fibrillation (P=0.02) but was not associated with other comorbidities. There was no correlation between MAC calcium score and mitral valve area (r=0.07; P=0.6) or mitral valve gradient (r=-0.03; P=0.8). CONCLUSIONS: MAC calcium score did not correlate with invasively measured mitral valve gradient and mitral valve area in patients with MAC-related mitral stenosis, suggesting that calcium score should not be used as a surrogate for invasive hemodynamic parameters.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Calcinosis , Enfermedades de las Válvulas Cardíacas , Estenosis de la Válvula Mitral , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Estenosis de la Válvula Mitral/complicaciones , Válvula Mitral/diagnóstico por imagen , Calcio , Estudios Retrospectivos , Fibrilación Atrial/complicaciones , Enfermedades de las Válvulas Cardíacas/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Constricción Patológica , Hemodinámica , Cateterismo Cardíaco
17.
Cardiovasc Revasc Med ; 58: 34-42, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37468384

RESUMEN

BACKGROUND: Amyloidosis is a common comorbidity in elderly patients with aortic stenosis (AS) referred for transcatheter aortic valve replacement (TAVR). This study aims to assess the impact of amyloidosis on the clinical outcomes of TAVR. METHODS: This is a retrospective study of the National Inpatient Sample database that identified adult patients (≥18 years) with AS hospitalized for TAVR from 2016 through 2020 to compare outcomes in those with versus without amyloidosis. Our primary outcome was in-hospital mortality. Secondary outcomes included procedural complications, hospital length of stay (LOS), and total costs. TAVR trends in both cohorts were also evaluated. RESULTS: The total cohort included 304,710 patients with AS undergoing TAVR, of whom 410 had amyloidosis. Over the study period, TAVR trends increased significantly in patients with and without amyloidosis (both ptrend < 0.01). Patients with amyloidosis were more likely to be older males with atrial fibrillation/flutter, congestive heart failure, renal disease, and dementia compared to non-amyloidosis patients. After adjustment for baseline characteristics, patients with amyloidosis had similar odds of in-hospital mortality (adjusted odds ratio [aOR] 1.66, 95 % confidence interval [CI] 0.34-3.63), heart block (aOR 1.33, 95 % CI 0.84-2.10), permanent pacemaker insertion (aOR 0.67, 95 % CI 0.27-1.66), stroke (aOR 0.90, 95 % CI 0.32-3.13), acute kidney injury, major bleeding, blood transfusion, vascular complications, in addition to similar LOS (p = 0.21) and total costs (p = 0.18) compared to patients without amyloidosis. CONCLUSION: In patients with AS undergoing TAVR, comorbid amyloidosis is associated with similar in-hospital mortality and procedural complications compared to patients without amyloidosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Adulto , Humanos , Estados Unidos/epidemiología , Anciano , Válvula Aórtica/cirugía , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Mortalidad Hospitalaria , Complicaciones Posoperatorias
19.
EuroIntervention ; 19(9): 720-738, 2023 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-37994096

RESUMEN

Mitral regurgitation is the second most frequent heart valve disease in Europe and the most frequent in the US. Although surgery is the therapy of choice when intervention is indicated, transcatheter mitral valve repair or replacement are alternatives for patients who are not eligible for surgery. However, the development of transcatheter mitral valves is slower than expected. Although several transcatheter heart valves have been developed, only one has been commercialised. Indeed, most of these devices are being evaluated in clinical studies, with promising initial results. In this review, we propose an overview on transcatheter mitral valve replacement for the treatment of native mitral valve disease, from indication to results, including patients with severe annular calcification, and we provide you with a glimpse into the future of these therapies.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos
20.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37968032

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Asunto(s)
Fibrilación Atrial , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Constricción Patológica/etiología , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Hemodinámica , Sistema de Registros , Diseño de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA