Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Eur Radiol ; 31(1): 515-524, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32785771

RESUMEN

OBJECTIVES: To compare the coronary vasodilation effects of spray with those induced by tablet administration in coronary CT angiography (CCTA). METHODS: A total of 2024 patients who underwent CCTA were identified for this retrospective study, including 828 patients with spray (spray group) and 1169 with tablets (tablet group). Of these, 93 patients underwent CCTA at least twice using both spray and tablets. The number of measurable segments and diameters of all 18 segments was measured. The number of measurable segments was compared between groups. RESULTS: No statistically significant differences were evident between these two groups in terms of clinical characteristics. All coronary segments except the ramus intermedius (RI) and left posterior descending artery (L-PDA) were significantly larger in the spray group than in the tablet group (all p < 0.001). In peripheral and branch vessels, as well as in central and main coronary arteries, the diameters were significantly larger in the spray group than in the tablet group (all p < 0.001). Although not always statistically significant, all coronary segments tended to be more measurable on CCTA with spray than with tablet. In the subgroup that underwent CCTA twice using both spray and tablets, all coronary segments except the RI, obtuse marginal artery 2 (OM2), and L-PDA were significantly larger in the spray group than in the tablet group (all p < 0.05). CONCLUSION: Lingual isosorbide dinitrate (ISDN) spray was more efficacious than sublingual nitroglycerin (NTG) tablets in coronary vasodilation for CCTA. Therefore, lingual ISDN spray should be preferred over sublingual NTG tablets for CCTA. KEY POINTS: • Lingual ISDN spray was more efficacious than sublingual NTG tablet for coronary vasodilation in coronary CT angiography, even in elderly patients. • The diameters of all coronary segments except RI and L-PDA were significantly larger, and there were significantly more coronary segments greater than 1.5 mm, except RI and L-PDA, in the spray group than in the tablet group in the whole study group. • Even in peripheral and branch vessels, the diameters of coronary arteries were significantly larger in the spray group than in the tablet group, and they were also larger in elderly patients.


Asunto(s)
Nitratos , Vasodilatación , Administración Sublingual , Anciano , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Humanos , Nitroglicerina/farmacología , Estudios Retrospectivos , Comprimidos
2.
Taehan Yongsang Uihakhoe Chi ; 81(6): 1486-1491, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36237727

RESUMEN

Kikuchi disease is a type of benign, self-limiting necrotizing lymphadenitis that occurs most commonly in young women and usually manifests as palpable cervical lymph nodes and fever. Patients with an unusual location of lymph node involvement can be misdiagnosed with malignant disease. Here, we report a case of Kikuchi disease in a 15-year-old girl presenting with persistent fever for 2 weeks. Imaging studies, including ultrasonography, CT, and 18F-fluorodeoxyglucose PET/CT, revealed splenomegaly and enlarged lymph nodes in the neck, axilla, abdomen, retroperitoneum, and inguinal region. Laparoscopic excision of the celiac lymph nodes confirmed histiocytic necrotizing lymphadenitis, also known as Kikuchi disease. Conservative treatment with corticosteroids improved the patient's condition.

3.
Korean J Radiol ; 19(4): 809-817, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29962888

RESUMEN

Objective: To evaluate the accuracy of emphysema volume (EV) and airway measurements (AMs) produced by various iterative reconstruction (IR) algorithms and virtual monoenergetic images (VME) at both low- and standard-dose settings. Materials and Methods: Computed tomography (CT) images were obtained on phantom at both low- (30 mAs at 120 kVp) and standard-doses (100 mAs at 120 kVp). Each CT scan was reconstructed using filtered back projection, hybrid IR (iDose4; Philips Healthcare), model-based IR (IMR-R1, IMR-ST1, IMR-SP1; Philips Healthcare), and VME at 70 keV (VME70). The EV of each air column and wall area percentage (WA%) of each airway tube were measured in all algorithms. Absolute percentage measurement errors of EV (APEvol) and AM (APEWA%) were then calculated. Results: Emphysema volume was most accurately measured in IMR-R1 (APEvol in low-dose, 0.053 ± 0.002; APEvol in standard-dose, 0.047 ± 0.003; all p < 0.001) and AM was the most accurate in IMR-SP1 on both low- and standard-doses CT (APEWA% in low-dose, 0.067 ± 0.002; APEWA% in standard-dose, 0.06 ± 0.003; all p < 0.001). There were no significant differences in the APEvol of IMR-R1 between low- and standard-doses (all p > 0.05). VME70 showed a significantly higher APEvol than iDose4, IMR-R1, and IMR-ST1 (all p < 0.004). VME70 also showed a significantly higher APEWA% compared with the other algorithms (all p < 0.001). Conclusion: IMR was the most accurate technique for measurement of both EV and airway wall thickness. However, VME70 did not show a significantly better accuracy compared with other algorithms.


Asunto(s)
Pulmón/diagnóstico por imagen , Enfisema Pulmonar/diagnóstico , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Fantasmas de Imagen , Enfisema Pulmonar/diagnóstico por imagen , Dosis de Radiación , Tomografía Computarizada por Rayos X/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA