Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Prosthodont Res ; 67(4): 641-646, 2023 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-37032072

RESUMEN

PURPOSE: We evaluated the effects of build orientation and bar addition between lingual flanges on the accuracy of mandibular denture bases fabricated using a digital light processing (DLP) device. METHODS: Mandibular denture bases with and without a bar at the lingual flanges were virtually designed and assigned to eight build orientations. Six dentures per condition were fabricated using a DLP device with a methacrylate-based photopolymerizable monomer (Dima Print denture base) (n=96). The fabricated denture surfaces were digitized, and intaglio surfaces were obtained. These digitized surfaces were compared via superimposition using graphical software (Artec studio12 profession) to their original designed files, and root mean square estimates were obtained. The trueness of the entire and intaglio data was statistically analyzed non-parametrically. RESULTS: The range of trueness of the entire and intaglio denture bases was 0.15-0.31 mm and 0.11-0.38 mm, respectively. The trueness at 135° and 270° for the entire denture base and that at 270° for the intaglio data without the bar were significantly lower than those for the other build orientations. The trueness at 270° was <0.15 mm irrespective of the conditions. The trueness with the bar of all build orientations, except that of 0° for intaglio data, was significantly smaller than or equal to the trueness without the bar of the corresponding build orientations. CONCLUSIONS: Build orientation and bar addition influenced the accuracy of the complete dentures fabricated using DLP. A build orientation of 270° is recommended for fabricating a mandibular complete denture, irrespective of the bar addition.

2.
Odontology ; 110(4): 664-672, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35322319

RESUMEN

The aim of this study was to evaluate the effect of thickness on the color appearance and translucency parameter (TP) of multilayer CAD/CAM composite resin blocks. Four brands of A3-shade multilayer CAD/CAM composite resin blocks were examined (Katana Avencia, CERASMART Multi, KZR-CAD HR Block 4 E-va, and Block HC Hard AN). Six specimens of five thicknesses were prepared for each brand, yielding 120 specimens in total. CIEL*a*b* values were determined using a spectrophotometer against black and white backgrounds, and the TP was calculated. The color differences (ΔE00) between layers (cervical/middle/incisal) and brands for each thickness against the black background were calculated using the CIEDE2000 system. As a result, on the black background, L* of the incisal layer was greater while a* and b* were smaller than those of the cervical layer for all brands. The ΔE00 values between the cervical and middle layers (1.23-3.27) were smaller than those between the cervical and incisal layers (3.98-5.67) and those between the middle and incisal layers (3.14-5.92). TP decreased with increasing block thickness. Some TP differences between layers were significant, but they were less than 2.75. In conclusion, the color appearance of CAD/CAM blocks was significantly influenced by both the thickness and layer. L*a*b* decreased with thickness, and a negative exponential relationship between TP and thickness was observed for all layers and brands.


Asunto(s)
Resinas Compuestas , Porcelana Dental , Cerámica , Color , Diseño Asistido por Computadora , Ensayo de Materiales , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA