1.
Sci Rep ; 13(1): 17471, 2023 10 14.
Artículo en Inglés | MEDLINE | ID: mdl-37838824

RESUMEN

Safe insertion of the Veress needle during laparoscopy relies on the surgeons' technical skills in order to stop needle insertion just in time to prevent overshooting in the underlying organs. To reduce this risk, a wide variety of Veress needle systems were developed with safety mechanisms that limit the insertion speed, insertion depth or decouple the driving force generated by the surgeon's hand on the needle. The aim of this study is to evaluate current surgeons' perceptions related to the use of Veress needles and to investigate the relevance of preventing overshooting of Veress needles among members of the European Association of Endoscopic Surgery (EAES). An online survey was distributed by the EAES Executive Office to all active members. The survey consisted of demographic data and 14 questions regarding the use of the Veress needle, the training conducted prior to usage, and the need for any improvement. A total of 365 members residing in 58 different countries responded the survey. Of the responding surgeons, 36% prefer the open method for patients with normal body mass index (BMI), and 22% for patients with high BMI. Of the surgeons using Veress needle, 68% indicated that the reduction of overshoot is beneficial in normal BMI patients, whereas 78% indicated that this is beneficial in high BMI patients. On average, the members using the Veress needle had used it for 1448 (SD 3031) times and felt comfortable on using it after 22,9 (SD 78,9) times. The average years of experience was 17,6 (SD 11,1) and the surgeons think that a maximum overshoot of 9.4 (SD 5.5) mm is acceptable before they can safely use the Veress needle. This survey indicates that despite the risks, Veress needles are still being used by the majority of the laparoscopic surgeons who responded. In addition, the surgeons responded that they were interested in using a Veress needle with an extra safety mechanism if it limits the risk of overshooting into the underlying structures.


Asunto(s)
Laparoscopía , Humanos , Laparoscopía/métodos , Agujas , Encuestas y Cuestionarios
2.
Updates Surg ; 74(5): 1749-1754, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35416585

RESUMEN

The complexity of handheld steerable laparoscopic instruments (SLI) may impair the learning curve compared to conventional instruments when first utilized. This study aimed to provide the current state of interest in the use of SLI, the current use of these in daily practice and the type of training which is conducted before using SLI in the operating room (OR) on real patients. An online survey was distributed by European Association of Endoscopic Surgery (EAES) Executive Office to all active members, between January 4th and February 3rd, 2020. The survey consisted of 14 questions regarding the usage and training of steerable laparoscopic instruments. A total of 83 members responded, coming from 33 different countries. Twenty three percent of the respondents using SLI, were using the instruments routinely and of these 21% had not received any formal training in advance of using the instruments in real patients. Of all responding EAES members, 41% considered the instruments to potentially compromise patient safety due to their complexity, learning curve and the inexperience of the surgeons. The respondents reported the three most important aspects of a possible steerable laparoscopic instruments training curriculum to be: hands-on training, safe tissue handling and suturing practice. Finally, a major part of the respondents consider force/pressure feedback data to be of significant importance for implementation of training and assessment of safe laparoscopic and robotic surgery. Training and assessment of skills regarding safe implementation of steerable laparoscopic instruments is lacking. The respondents stressed the need for specific hands-on training during which feedback and assessment of skills should be guaranteed before operating on real patients.


Asunto(s)
Laparoscopía , Cirujanos , Competencia Clínica , Humanos , Curva de Aprendizaje , Encuestas y Cuestionarios
3.
Surg Endosc ; 36(2): 1064-1079, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33638104

RESUMEN

BACKGROUND: Robotic-assisted surgery (RAS) potentially reduces workload and shortens the surgical learning curve compared to conventional laparoscopy (CL). The present study aimed to compare robotic-assisted cholecystectomy (RAC) to laparoscopic cholecystectomy (LC) in the initial learning phase for novices. METHODS: In a randomized crossover study, medical students (n = 40) in their clinical years performed both LC and RAC on a cadaveric porcine model. After standardized instructions and basic skill training, group 1 started with RAC and then performed LC, while group 2 started with LC and then performed RAC. The primary endpoint was surgical performance measured with Objective Structured Assessment of Technical Skills (OSATS) score, secondary endpoints included operating time, complications (liver damage, gallbladder perforations, vessel damage), force applied to tissue, and subjective workload assessment. RESULTS: Surgical performance was better for RAC than for LC for total OSATS (RAC = 77.4 ± 7.9 vs. LC = 73.8 ± 9.4; p = 0.025, global OSATS (RAC = 27.2 ± 1.0 vs. LC = 26.5 ± 1.6; p = 0.012, and task specific OSATS score (RAC = 50.5 ± 7.5 vs. LC = 47.1 ± 8.5; p = 0.037). There were less complications with RAC than with LC (10 (25.6%) vs. 26 (65.0%), p = 0.006) but no difference in operating times (RAC = 77.0 ± 15.3 vs. LC = 75.5 ± 15.3 min; p = 0.517). Force applied to tissue was similar. Students found RAC less physical demanding and less frustrating than LC. CONCLUSIONS: Novices performed their first cholecystectomies with better performance and less complications with RAS than with CL, while operating time showed no differences. Students perceived less subjective workload for RAS than for CL. Unlike our expectations, the lack of haptic feedback on the robotic system did not lead to higher force application during RAC than LC and did not increase tissue damage. These results show potential advantages for RAS over CL for surgical novices while performing their first RAC and LC using an ex vivo cadaveric porcine model. REGISTRATION NUMBER: researchregistry6029.


Asunto(s)
Colecistectomía Laparoscópica , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Animales , Colecistectomía/métodos , Colecistectomía Laparoscópica/métodos , Competencia Clínica , Estudios Cruzados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Porcinos
4.
Tech Coloproctol ; 23(9): 843-852, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31432333

RESUMEN

BACKGROUND: Transanal total mesorectal excision (TaTME) is associated with a relatively long learning curve. Force, motion, and time parameters are increasingly used for objective assessment of skills to enhance laparoscopic training efficacy. The aim of this study was to identify relevant metrics for accurate skill assessment in more complex transanal purse-string suturing. METHODS: A box trainer was designed for TaTME and equipped with two custom made multi-DOF force/torque sensors. These sensors measured the applied forces in the axial direction of the instruments (Fz), instrument load orientation expressed in torque (Mx and My) on the entrance port, and the full tissue interaction force (Fft) at the intestine fixation point. In a construct validity study, novices for TaTME performed a purse-string suture to investigate which parameters can be used best to identify meaningful events during tissue manipulation and instrument handling. RESULTS: Significant differences exist between pre- and post-training assessment for the mean axial force at the entrance port Fz (p = 0.01), mean torque in the entrance port Mx (p = 0.03) and mean force on the intestine during suturing Fft (p = 0.05). Furthermore, force levels during suturing exceed safety threshold values, potentially leading to dangerous complications such as rupture of the rectum. CONCLUSIONS: Forces and torque measured at the entrance port, and the tissue interaction force signatures provide detailed insight into instrument handling, instrument loading, and tissue handling during purse-string suturing in a TaTME training setup. This newly developed training setup for single-port laparoscopy that enables objective feedback has the potential to enhance surgical training in TaTME.


Asunto(s)
Evaluación Educacional/métodos , Laparoscopía/educación , Proctectomía/educación , Técnicas de Sutura/educación , Cirugía Endoscópica Transanal/educación , Adulto , Competencia Clínica , Femenino , Humanos , Laparoscopía/instrumentación , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Tempo Operativo , Proctectomía/instrumentación , Técnicas de Sutura/instrumentación , Torque , Cirugía Endoscópica Transanal/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA