Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 194
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Oral Oncol ; 93: 107-113, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31109690

RESUMEN

OBJECTIVES: The prognostic value of metabolic tumor volume (MTV) in locally advanced laryngeal or hypopharyngeal cancer is established in the setting of chemoradiotherapy, while it remains unknown in the setting of upfront total laryngectomy. MATERIALS AND METHODS: We retrospectively analyzed 88 patients receiving total laryngectomy and neck dissection, using Cox regression models. RESULTS AND CONCLUSION: Variables related to metastatic lymph node were associated with overall survival, whereas those related to primary tumor were not. In multivariable models, MTV of metastatic lymph nodes (N-MTV) as a continuous variable (Akaike's information criterion (AIC), 277.5) was equivalent to pathological nodal status (AIC, 278.2; P = 0.40), and superior to pathological nodal classification as an ordinal variable (AIC, 281.4; P < 0.05) in ability of predicting death. The risk of death was increased by 1.2-fold (95% confidence interval (CI), 1.0-1.4; P = 0.03) every 10-ml increment of N-MTV, while patients with pN+ disease were at a higher risk of death by 2.9-fold (95% CI, 1.0-12.2; P < 0.05) compared with patients with pN0 disease. Using recursive partitioning analysis (RPA), we classified the patients as having a low, intermediate, or high risk of death on the basis of N-MTV and extranodal extension (ENE). This RPA classification system exhibited greater concordance with overall survival than the classification considering pathological nodal status and ENE (AIC, 275.8 versus 281.4; P = 0.02). In the setting of upfront total laryngectomy, N-MTV is a critical predictor of mortality. A staging system in which N-MTV is incorporated may better inform adjuvant treatment decisions.


Asunto(s)
Neoplasias Hipofaríngeas/mortalidad , Neoplasias Hipofaríngeas/cirugía , Neoplasias Laríngeas/mortalidad , Neoplasias Laríngeas/cirugía , Metástasis Linfática/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Hipofaríngeas/patología , Neoplasias Laríngeas/patología , Laringectomía , Masculino , Persona de Mediana Edad , Disección del Cuello , Estadificación de Neoplasias , Análisis de Regresión , Estudios Retrospectivos , Análisis de Supervivencia , Resultado del Tratamiento , Carga Tumoral
2.
AJNR Am J Neuroradiol ; 37(1): 44-50, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26381556

RESUMEN

BACKGROUND AND PURPOSE: Noninvasive radiologic evaluation of glioma can facilitate correct diagnosis and detection of malignant transformation. Although positron-emission tomography is considered valuable in the care of patients with gliomas, (18)F-fluorodeoxyglucose and (11)C-methionine have reportedly shown ambiguous results in terms of grading and prognostication. The present study compared the diagnostic and prognostic capabilities of diffusion tensor imaging, FDG, and (11)C-methionine PET in nonenhancing gliomas. MATERIALS AND METHODS: Thirty-five consecutive newly diagnosed, histologically confirmed nonenhancing gliomas that underwent both FDG and (11)C-methionine PET were retrospectively investigated (23 grade II and 12 grade III gliomas). Apparent diffusion coefficient, fractional anisotropy, and tumor-to-normal tissue ratios of both FDG and (11)C-methionine PET were compared between grade II and III gliomas. Prognostic values of these parameters were also tested by using progression-free survival. RESULTS: Grade III gliomas showed significantly higher average tumor-to-normal tissue and maximum tumor2-to-normal tissue than grade II gliomas in (11)C-methionine (P = .013, P = .0017, respectively), but not in FDG-PET imaging. There was no significant difference in average ADC, minimum ADC, average fractional anisotropy, and maximum fractional anisotropy. (11)C-methionine PET maximum tumor-to-normal tissue ratio of 2.0 was most suitable for detecting grade III gliomas among nonenhancing gliomas (sensitivity, 83.3%; specificity, 73.9%). Among patients not receiving any adjuvant therapy, median progression-free survival was 64.2 ± 7.2 months in patients with maximum tumor-to-normal tissue ratio of <2.0 for (11)C-methionine PET and 18.6 ± 6.9 months in patients with maximum tumor-to-normal tissue ratio of >2.0 (P = .0044). CONCLUSIONS: (11)C-methionine PET holds promise for World Health Organization grading and could offer a prognostic imaging biomarker for nonenhancing gliomas.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Clasificación del Tumor/métodos , Tomografía de Emisión de Positrones/métodos , Anciano , Neoplasias Encefálicas/mortalidad , Radioisótopos de Carbono , Supervivencia sin Enfermedad , Femenino , Glioma/mortalidad , Humanos , Masculino , Metionina , Persona de Mediana Edad , Pronóstico , Radiofármacos , Estudios Retrospectivos , Adulto Joven
3.
AJNR Am J Neuroradiol ; 33(11): 2088-94, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22627794

RESUMEN

BACKGROUND AND PURPOSE: It has been suggested, on the basis of a previous pilot study conducted in a small number of patients, that MR imaging-based PVE correction in I-123 iomazenil brain SPECT improves the detectability of cortical epileptogenic foci. In the present study, we performed an investigation by using a larger sample size to establish the effectiveness of the PVE correction and to conduct a detailed evaluation based on the histologic classification of lesions. MATERIALS AND METHODS: Seventy-five patients (male/female, 37/38; age, 28 ± 12 years) with intractable epilepsy who had undergone surgical treatment were enrolled in this study. I-123 iomazenil SPECT and MR imaging examinations were performed before the operation in all patients. I-123 iomazenil SPECT images with and without MR imaging-based PVE correction were assessed visually and by semiquantitative analysis based on the AI(%) of the SPECT count in the resected lesions. RESULTS: The sensitivity, specificity, and accuracy of foci detection by visual assessment were significantly higher after PVE correction compared with the values obtained before the correction. The results of the semiquantitative analysis revealed that the asymmetry of the SPECT counts was significantly increased after the PVE correction in the surgically resected lesions in cases of mesial temporal sclerosis, tumor, and malformations of cortical development. CONCLUSIONS: The effectiveness of MR imaging-based PVE correction in I-123 iomazenil brain SPECT in improving the detection of cortical epileptogenic foci with abnormal histologic findings was established by our investigation conducted on a large sample size.


Asunto(s)
Algoritmos , Artefactos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Epilepsia/diagnóstico , Flumazenil/análogos & derivados , Aumento de la Imagen/métodos , Adulto , Epilepsia/cirugía , Reacciones Falso Negativas , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Radiofármacos , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión de Fotón Único
4.
AJNR Am J Neuroradiol ; 33(8): 1458-63, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22403779

RESUMEN

BACKGROUND AND PURPOSE: CBR imaging is highly susceptible to a PVE produced by morphologic changes in the brain related to aging and brain laterality. We assessed the influence of PVE produced by regional age-related changes in gray matter volume on I-123 iomazenil SPECT and elucidated the age-related changes in human CBR binding by using PVE-corrected SPECT images. MATERIALS AND METHODS: Nineteen right-handed healthy volunteers (range, 25-82 years; mean, 55 ± 21 years) underwent MR imaging and quantitative I-123 iomazenil SPECT imaging. The influence of age-related changes in rGMC on SPECT images before PVE correction was assessed. PVE correction of the SPECT images was performed by using an MR imaging-based method. Voxel-based linear regression analyses of the PVE-corrected SPECT images were performed by using SPM5. RESULTS: The age-related reductions in rGMC and BP without PVE correction revealed a significant direct proportional correlation. Voxel-based statistical analysis with PVE correction showed no significant age-related changes in BP. CONCLUSIONS: PVE correction was indispensable for the analysis of I-123 iomazenil SPECT images. PVE-corrected quantitative I-123 iomazenil SPECT images revealed no age-related changes in CBR binding in right-handed healthy humans.


Asunto(s)
Encéfalo/diagnóstico por imagen , Flumazenil/análogos & derivados , Lateralidad Funcional , Procesamiento de Imagen Asistido por Computador , Radioisótopos de Yodo , Radiofármacos , Receptores de GABA-A/metabolismo , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Anciano de 80 o más Años , Envejecimiento , Encéfalo/metabolismo , Encéfalo/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad
5.
Med Phys ; 39(2): 581-8, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22320767

RESUMEN

PURPOSE: In small animal imaging using a single photon emitting radionuclide, a high resolution gamma camera is required. Recently, position sensitive photomultiplier tubes (PSPMTs) with high quantum efficiency have been developed. By combining these with nonhygroscopic scintillators with a relatively low light output, a high resolution gamma camera can become useful for low energy gamma photons. Therefore, the authors developed a gamma camera by combining a pixelated Ce-doped Gd(2)SiO(5) (GSO) block with a high quantum efficiency PSPMT. METHODS: GSO was selected for the scintillator, because it is not hygroscopic and does not contain any natural radioactivity. An array of 1.9 mm × 1.9 mm × 7 mm individual GSO crystal elements was constructed. These GSOs were combined with a 0.1-mm thick reflector to form a 22 × 22 matrix and optically coupled to a high quantum efficiency PSPMT (H8500C-100 MOD8). The GSO gamma camera was encased in a tungsten gamma-ray shield with tungsten pixelated parallel hole collimator, and the basic performance was measured for Co-57 gamma photons (122 keV). RESULTS: In a two-dimensional position histogram, all pixels were clearly resolved. The energy resolution was ∼15% FWHM. With the 20-mm thick tungsten pixelated collimator, the spatial resolution was 4.4-mm FWHM 40 mm from the collimator surface, and the sensitivity was ∼0.05%. Phantom and small animal images were successfully obtained with our developed gamma camera. CONCLUSIONS: These results confirmed that the developed pixelated GSO gamma camera has potential as an effective instrument for low energy gamma photon imaging.


Asunto(s)
Cámaras gamma/veterinaria , Aumento de la Imagen/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/veterinaria , Imagen de Cuerpo Entero/instrumentación , Imagen de Cuerpo Entero/veterinaria , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Masculino , Ratas , Ratas Wistar , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
AJNR Am J Neuroradiol ; 29(10): 1841-6, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18653680

RESUMEN

BACKGROUND AND PURPOSE: Chronic middle cerebral artery (MCA) occlusion is more common than generally thought. It is important to assess the cerebral hemodynamic status in patients with this chronic condition. We investigated the cerebral hemodynamic and metabolic disturbances in these patients in relation to the development of the collateral vasculature. MATERIALS AND METHODS: We studied 13 patients with chronic unilateral MCA occlusion who had a minor or no stroke by using positron-emission tomography (PET). PET was performed by the oxygen 15 ((15)O) gas steady-state inhalation method. The intracranial arteries were evaluated by digital subtraction angiography. We divided the patients into 2 subgroups according to whether they had a normal or increased oxygen extraction fraction (OEF) in the occluded MCA territory and compared the 2 groups. RESULTS: Of the 13 patients, 9 were classified into the normal OEF and 4 were classified into the increased OEF group. In the increased OEF group, the mean OEF values were also increased in the territories of the ipsilateral anterior cerebral artery, ipsilateral posterior cerebral artery, and contralateral MCA. The patients in the increased OEF group had more than 1 steno-occlusive lesion in the major intracranial arteries (P = .008). Three of the 4 patients in the increased OEF group also had vascular lesions in the collateral pathways to the MCA territory. CONCLUSION: Most patients with chronic MCA occlusion did not show severe hemodynamic impairment. Those with increased OEF tended to have other areas of severe hemodynamic impairment and other vascular lesions, especially in the collateral pathways.


Asunto(s)
Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/metabolismo , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Infarto de la Arteria Cerebral Media/metabolismo , Radioisótopos de Oxígeno/farmacocinética , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Isquemia Encefálica/etiología , Enfermedad Crónica , Femenino , Hemodinámica , Humanos , Infarto de la Arteria Cerebral Media/complicaciones , Infarto de la Arteria Cerebral Media/fisiopatología , Masculino , Persona de Mediana Edad , Radiofármacos/farmacocinética
7.
Br J Radiol ; 80(949): e24-6, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17267466

RESUMEN

Castleman's disease (CD) appears at ubiquitous lymph nodes. To date, detection of the lesion focus for CD has mainly been carried out by physical examination and radiological findings, such as X-ray analysis, CT and MRI. 18F-FDG PET visualizes the active focus of glucose metabolism and the clinical value has been investigated for many different tumours. Previous studies of 18F-FDG PET for CD have only reported four cases of unicentric CD and no cases of multicentric CD. In this paper, we report two cases of CD, one with unicentric CD and one with multicentric CD. We demonstrate that the use of 18F-FDG PET for the detection and monitoring of patients with CD, especially multicentric CD, would be effective.


Asunto(s)
Enfermedad de Castleman/diagnóstico por imagen , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Adulto , Humanos , Masculino , Persona de Mediana Edad
8.
Neurology ; 67(5): 887-90, 2006 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-16966560

RESUMEN

The authors examined the neural function of a postmeningitic deaf-blind patient who regained his hearing with a multichannel cochlear implant. Auditory stimuli activated the temporal cortices of both sides in a manner similar to that of controls, reflecting the successful recruitment of the auditory cortex after implantation. The patient's occipital lobes were deactivated during the tactile language task, the results of which were completely different from those before cochlear implantation.


Asunto(s)
Percepción Auditiva/fisiología , Ceguera/fisiopatología , Implantación Coclear/métodos , Sordera/fisiopatología , Tacto/fisiología , Adulto , Corteza Auditiva/diagnóstico por imagen , Corteza Auditiva/fisiopatología , Corteza Auditiva/cirugía , Ceguera/etiología , Estudios de Casos y Controles , Corteza Cerebral/irrigación sanguínea , Corteza Cerebral/diagnóstico por imagen , Sordera/diagnóstico por imagen , Sordera/etiología , Sordera/cirugía , Humanos , Masculino , Meningitis/complicaciones , Personas con Deficiencia Auditiva , Estimulación Física/métodos , Tomografía de Emisión de Positrones/métodos , Flujo Sanguíneo Regional/fisiología
9.
AJNR Am J Neuroradiol ; 27(1): 40-5, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16418353

RESUMEN

BACKGROUND AND PURPOSE: We evaluated the effects of varying tube voltage, current per rotation, and section thickness on detectability of 2- and 4-Hounsfield unit (HU) differences on brain CT between normal and ischemic gray matter within 6 hours of ischemia onset, by using a low-contrast phantom. METHODS: The phantom with an attenuation of 36 HU corresponding to normal gray matter contained 2 sets of spheres (34 HU and 32 HU) corresponding to the early CT signs of ischemic brain and complete infarction, respectively. The reproducibility of the CT numbers and the contrast-to-noise ratio (CNR), defined as the CT number difference between the background (36 HU) and the spheres (34 HU or 32 HU) divided by the SD of the background CT number were measured. Five radiologists rated the phantom images for detection of the low-contrast spheres by visual inspection. RESULTS: The CT numbers were reproducible within 1 HU with a tube current of > or =150 mAs at 120 kVp. The CNRs for the 34- and 32-HU spheres were positively correlated with the tube voltage, tube current per rotation, and the section thickness. A CNR of 1.0 was obtained for the 34-HU sphere when scanning was conducted with a section thickness of 10 mm at 120 kVp and 700 mAs, or 135kVp and 450 mAs, respectively. A significant improvement of the accuracy of detection was found with increasing tube current, tube voltage per rotation, and section thickness. CONCLUSION: Our study indicated that the 2-HU hypoattenuation corresponding to the early CT sign of acute ischemic stroke can be detected by using appropriate parameter settings.


Asunto(s)
Encéfalo/diagnóstico por imagen , Infarto Cerebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Enfermedad Aguda , Isquemia Encefálica/diagnóstico por imagen , Humanos , Variaciones Dependientes del Observador , Fantasmas de Imagen , Dosis de Radiación , Reproducibilidad de los Resultados
10.
Exp Clin Endocrinol Diabetes ; 112(10): 601-3, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15578336

RESUMEN

We describe a patient with extra-adrenal pheochromocytoma and high plasma norepinephrine levels. Radionuclide images of this patient obtained using (18)F-fluorodeoxyglucose and (123)I-metaiodobenzylguanidine revealed bilateral tracer accumulation in the shoulder and lower neck. The regions of radiotracer uptake corresponded to the location of human brown adipose tissue (BAT). Excessive sympathetic stimulation by high circulating catecholamine concentrations augmented the metabolic activity and tracer uptake in the BAT. This study showed that radionuclide imaging can noninvasively visualize human BAT in terms of metabolic and functional activity.


Asunto(s)
Tejido Adiposo Pardo/diagnóstico por imagen , Neoplasias de las Glándulas Suprarrenales/diagnóstico por imagen , Feocromocitoma/diagnóstico por imagen , Adolescente , Fluorodesoxiglucosa F18 , Humanos , Masculino , Tomografía de Emisión de Positrones , Radiofármacos , Tomografía Computarizada por Rayos X
11.
Acta Neurochir Suppl ; 82: 93-8, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12378998

RESUMEN

Mild hypothermia is thought to have a brain protective effect to pathophysiological conditions, which are caused by severe brain damage including brain injury and cerebral stroke. In this paper, general aspects of this treatment as history, pathophysiological effect, and problems are summarized. Also, the clinical effects of hypothermic therapy for a subarachnoid hemorrhage are reviewed. Main targets of the therapy for this disease are severe primary brain damage caused by the attack itself and secondary ischemic brain damage after delayed vasospasm. But even now, there are no fully established data about the effect of hypothermia at such conditions after subarachnoid hemorrhage. The results of our study of cerebral blood flow and cerebral oxygen metabolism using positron emission tomography are presented to show the physiological effect of hypothermia on human brain after severe brain damage caused by subarachnoid hemorrhage. In conclusion, effect of hypothermia on subarachnoid hemorrhage is not confirmed yet and reported data is limited, so that additional studies, especially controlled studies, would be recommended.


Asunto(s)
Daño Encefálico Crónico/prevención & control , Hipotermia Inducida/métodos , Hemorragia Subaracnoidea/terapia , Adulto , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/irrigación sanguínea , Daño Encefálico Crónico/diagnóstico por imagen , Daño Encefálico Crónico/fisiopatología , Diseño de Equipo , Femenino , Humanos , Hipotermia Inducida/instrumentación , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Estudios Retrospectivos , Hemorragia Subaracnoidea/diagnóstico por imagen , Hemorragia Subaracnoidea/fisiopatología , Tomografía Computarizada de Emisión/instrumentación , Vasoespasmo Intracraneal/diagnóstico por imagen , Vasoespasmo Intracraneal/fisiopatología , Vasoespasmo Intracraneal/terapia
12.
Neuroradiology ; 43(9): 763-6, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11594428

RESUMEN

Chordomas are histologically benign tumours which are locally invasive. We present an unusual case of recurrent chordoma with subcutaneous implantation and widespread meningeal dissemination after surgery. Contrast-enhanced MRI was useful for determining the extent of the tumour.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Cordoma/diagnóstico , Neoplasias Meníngeas/secundario , Neoplasias de los Tejidos Blandos/secundario , Neoplasias Encefálicas/patología , Cordoma/patología , Medios de Contraste , Craneotomía , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia
13.
Brain Res Cogn Brain Res ; 12(1): 101-8, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11489613

RESUMEN

As in visual processing, we speculated that, in music processing, different brain regions would activate according to the mode of music listening. Using motets by a famous composer, we studied changes in regional cerebral blood flow (rCBF) with positron emission tomography associated with concentrating on the alto-part within the harmony (alto-part-listening condition) compared to listening to the harmony as a whole (harmony-listening condition). The alto-part-listening condition was associated with bilateral increases of rCBF in superior parietal lobules, precunei, premotor areas and orbital frontal cortices. Superior parietal lobules are likely to be responsible for auditory selective attention to the alto part within the harmony and the analysis of tone pitch on a mental score. The precuneus possibly participated in writing tones of the alto part on a mental score. Based on our findings, we propose that both auditory selective attention and analytic processing play an important role in concentrating on a certain vocal part within a harmony. During the harmony-listening condition, temporal poles, the anterior portion of the cingulate gyrus, occipital cortex and the medial surface of the cerebellum were bilaterally activated. Further studies are necessary to clarify the difference in music processing between musicians and nonmusicians.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/fisiología , Música/psicología , Adulto , Percepción Auditiva/fisiología , Circulación Cerebrovascular , Humanos , Masculino , Lóbulo Parietal/fisiología , Tomografía Computarizada de Emisión
14.
Ann Nucl Med ; 15(2): 111-6, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11448068

RESUMEN

In quantitative functional neuroimaging with positron emission tomography (PET) and magnetic resonance imaging (MRI), cerebral blood volume (CBV) and its three components, arterial, capillary, and venous blood volumes are important factors. The arterial fraction for systemic circulation of the whole body has been reported to be 20-30%, but there is no report of this fraction in the brain. In the present study, we estimated the arterial fraction of CBV with PET in the living human brain. C(15)O and dynamic H2(15)O PET studies were performed in each of seven healthy subjects to determine the CBV and arterial blood volume (Va), respectively. A two-compartment model (influx: K1, efflux: k2) that takes Va into account was applied to describe the regional time-activity curve of dynamic H2(15)O PET. K1, k2 and Va were calculated by a non-linear least squares fitting procedure. The Va and CBV values were 0.011 +/- 0.004 ml/ml and 0.031 +/- 0.003 ml/ml (mean +/- SD), respectively, for cerebral cortices. The arterial fraction of CBV was 37%. Considering the limited first-pass extraction fraction of H2(15)O, the true arterial fraction of CBV is estimated to be about 30%. The estimated arterial fraction of CBV was quite similar to that of the systemic circulation, whereas it was greater than that (16%) widely used for the measurement of cerebral metabolic rate of oxygen (CMRO2) using PET. The venous plus capillary fraction of CBV was 63-70% which is a important factor for the measurement of CMRO2 with MRI.


Asunto(s)
Volumen Sanguíneo , Arterias Cerebrales/diagnóstico por imagen , Circulación Cerebrovascular , Tomografía Computarizada de Emisión/métodos , Adulto , Radioisótopos de Carbono , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Neurológicos , Radioisótopos de Oxígeno , Valores de Referencia
15.
Ann Nucl Med ; 15(2): 123-9, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11448070

RESUMEN

To evaluate the usefulness of a combination of linearization and scatter-attenuation correction on 99mTc-bicisate (ECD)-single photon emission tomographic (SPECT) images, both cerebral blood flow (CBF)-positron emission tomographic (PET) images and ECD-SPECT images from fifteen patients with chronic cerebral infarction were acquired. We measured radioactivity counts in regions of interest (ROIs) on all sets of both images and obtained a 2D scattered graph between ECD-SPECT and CBF-PET data. To evaluate diagnostic accuracy, the sensitivity, specificity and accuracy of ECD-SPECT images were calculated by means of discriminant analysis. The same analysis was also performed on the ECD-SPECT images corrected by a combination of linearization and scatter-attenuation correction. An overall nonlinear relationship was observed between ECD-SPECT and CBF-PET. The sensitivity, specificity, and accuracy of ECD-SPECT images were 69.6%, 91.4% and 73.0%, and those of ECD images corrected by the combination of linearization and scatter-attenuation correction were 79.5%, 95.7% and 82.0% respectively. The clinically diagnostic accuracy of ECD-SPECT images corrected by the combined method apparently increased. So that the linearization with the scatter-attenuation method is useful for improving the diagnostic accuracy of ECD-SPECT images.


Asunto(s)
Encéfalo/diagnóstico por imagen , Cisteína/análogos & derivados , Compuestos de Organotecnecio , Tomografía Computarizada de Emisión de Fotón Único/métodos , Anciano , Infarto Cerebral/diagnóstico por imagen , Circulación Cerebrovascular , Enfermedad Crónica , Análisis Discriminante , Femenino , Humanos , Modelos Lineales , Masculino , Persona de Mediana Edad , Radioisótopos de Oxígeno , Radiofármacos , Dispersión de Radiación , Sensibilidad y Especificidad , Tomografía Computarizada de Emisión , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos
16.
J Cereb Blood Flow Metab ; 21(5): 608-12, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11333371

RESUMEN

The hemodynamic mechanism of increase in cerebral blood flow (CBF) during neural activation has not been elucidated in humans. In the current study, changes in both regional CBF and cerebral blood volume (CBV) during visual stimulation in humans were investigated. Cerebral blood flow and CBV were measured by positron emission tomography using H(2)(15)O and (11)CO, respectively, at rest and during 2-Hz and 8-Hz photic flicker stimulation in each of 10 subjects. Changes in CBF in the primary visual cortex were 16% +/- 16% and 68% +/- 20% for the visual stimulation of 2 Hz and 8 Hz, respectively. The changes in CBV were 10% +/- 13% and 21% +/- 5% for 2-Hz and 8-Hz stimulation, respectively. Significant differences between changes in CBF and CBV were observed for visual stimulation of 8 Hz. The relation between CBF and CBV values during rest and visual stimulation was CBV = 0.88CBF(0.30). This indicates that when the increase in CBF during neural activation is great, that increase is caused primarily by the increase in vascular blood velocity rather than by the increase in CBV. This observation is consistent with reported findings obtained during hypercapnia.


Asunto(s)
Volumen Sanguíneo , Encéfalo/irrigación sanguínea , Encéfalo/fisiología , Estimulación Luminosa , Tomografía Computarizada de Emisión , Adulto , Velocidad del Flujo Sanguíneo , Presión Sanguínea , Dióxido de Carbono/sangre , Frecuencia Cardíaca , Humanos , Concentración de Iones de Hidrógeno , Masculino , Oxígeno/sangre
17.
Pancreas ; 22(2): 203-9, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11249078

RESUMEN

Positron emission tomography (PET) can be used for the quantitative analysis of amino acid metabolism. The aim of this study was to investigate whether pancreatic exocrine function can be evaluated by [11C]methionine PET in chronic pancreatitis (CP) patients. Dynamic PET scan of the pancreas and liver was performed in eight healthy subjects and seven patients with CP after intravenous (i.v.) injection of [11C]methionine. Simultaneously, duodenal juice was collected with the background of continuous i.v. administration of secretin (125 ng/kg/h). The radioactivity ratio of the pancreas to that of the liver (PLR) was calculated by regions of interest (ROI) analysis. Amylase output and bicarbonate concentration were measured in the duodenal aspirates. The PLR of CP patients was significantly lower than that of healthy subjects at all time points after methionine injection. The PLRs at 4.5 minutes (PLR4.5) after methionine injection were positively correlated with the amylase output, mean bicarbonate concentration, and volume of duodenal aspirates (R = 0.74, 0.69, 0.46). It is concluded that [11C]methionine PET would be a noninvasive method for the evaluation of exocrine pancreatic function, which may represent total amino acids uptake of viable acinar cells in the pancreas.


Asunto(s)
Radioisótopos de Carbono , Metionina/metabolismo , Páncreas/fisiopatología , Pancreatitis/diagnóstico por imagen , Tomografía Computarizada de Emisión , Adulto , Enfermedad Crónica , Humanos , Masculino , Persona de Mediana Edad , Pancreatitis/fisiopatología
18.
Synapse ; 39(2): 182-92, 2001 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11180506

RESUMEN

The novel muscarinic cholinergic ligands (+)N-[11C]methyl-3-piperidyl benzilate ([11C](+)3-MPB) and its stereoisomer [11C](-)3-MPB were evaluated in comparison with [11C]4-MPB in the brains of conscious monkeys (Macaca mulatta) using high-resolution positron emission tomography (PET). The regional distribution patterns of [11C](+)3-MPB and [11C]4-MPB at 60-91 min postinjection were almost identical: highest in the striatum and occipital cortex; intermediate in the temporal and frontal cortices, cingulate gyrus, hippocampus, and thalamus; lower in the pons; and lowest in the cerebellum. The uptake of [11C](+)3-MPB in all regions was higher and the dynamic range of regional uptake differences of [11C](+)3-MPB was better than those of [11C]4-MPB. The levels of [11C](-)3-MPB were much lower in all regions of the brain than [11C](+)3-MPB and [11C]4-MPB. Administration of scopolamine, a muscarinic cholinergic antagonist, at a dose of 50 microg/kg reduced the radioactivity of [11C](+)3-MPB and [11C]4-MPB in all regions except the cerebellum. Time-activity curves of [11C](+)3-MPB peaked in all regions, while those of [11C]4-MPB showed gradual increases with time in all regions except the thalamus, pons, and cerebellum. Two graphical analyses (Logan plot and Patlak plot) with plasma radioactivity as an input function into the brain were applied to evaluate receptor binding in vivo. [11C](+)3-MPB showed linear regression curves on Logan plot analysis and nonlinear curves on Patlak plot in all regions, suggesting that [11C](+)3-MPB bound reversibly to the muscarinic receptors. The in vivo binding parameters as well as uptake at 60-91 min postinjection of [11C](+)3-MPB were consistent with muscarinic receptor density in the brain as reported in vitro.


Asunto(s)
Bencilatos/síntesis química , Bencilatos/farmacocinética , Encéfalo/efectos de los fármacos , Encéfalo/diagnóstico por imagen , Alucinógenos/farmacología , Receptores Muscarínicos/efectos de los fármacos , Animales , Radioisótopos de Carbono , Estado de Conciencia/efectos de los fármacos , Estado de Conciencia/fisiología , Macaca mulatta , Masculino , Piperidinas/farmacocinética , Receptores Muscarínicos/metabolismo , Estereoisomerismo , Tomografía Computarizada de Emisión
19.
Rinsho Shinkeigaku ; 41(10): 659-64, 2001 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-11993184

RESUMEN

To investigate whether the striatal dopamine receptor function is involved in the development of vascular parkinsonism (VP), a positron emission tomography (PET) study was conducted on 9 patients with VP by using [11C] N-methylspiperone as the tracer. The rate of binding availability in the striatal dopamine D2 receptor (k3) was determined semiquantitatively, and the values were compared to the predicted normal values based on the results from 7 normal volunteers. Of 9 patients with VP, the normalized D2 receptor binding [%k3] was more than 90% in 5 patients, 89 to 87% in 3, and 75% in one. These values showed no evident correlation with the Hoehn and Yahr stage. The laterality of the striatal %k3 did not correspond to that of the parkinsonism. Thus, the striatal dopamine D2 receptor binding was not severely impaired and did not correlate with the neurological status in patients with VP. This may indicate that striatal dopamine D2 receptor function is not primarily associated with the development of the parkinsonism in VP.


Asunto(s)
Enfermedad de Parkinson/metabolismo , Receptores de Dopamina D2/metabolismo , Anciano , Envejecimiento/metabolismo , Femenino , Humanos , Masculino , Enfermedad de Parkinson/diagnóstico por imagen , Valor Predictivo de las Pruebas , Tomografía Computarizada de Emisión
20.
J Neurosurg ; 93(6): 1014-8, 2000 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11117843

RESUMEN

OBJECT: The mechanism of reduction of cerebral circulation and metabolism in patients in the acute stage of aneurysmal subarachnoid hemorrhage (SAH) has not yet been fully clarified. The goal of this study was to elucidate this mechanism further. METHODS: The authors estimated cerebral blood flow (CBF), cerebral metabolic rate of oxygen (CMRO2), O2 extraction fraction (OEF), and cerebral blood volume (CBV) preoperatively in eight patients with aneurysmal SAH (one man and seven women, mean age 63.5 years) within 40 hours of onset by using positron emission tomography (PET). The patients' CBF, CMRO2, and CBF/CBV were significantly lower than those in normal control volunteers. However, OEF and CBV did not differ significantly from those in control volunteers. The significant decrease in CBF/CBV, which indicates reduced cerebral perfusion pressure, was believed to be caused by impaired cerebral circulation due to elevated intracranial pressure (ICP) after rupture of the aneurysm. In two of the eight patients, uncoupling between CBF and CMRO2 was shown, strongly suggesting the presence of cerebral ischemia. CONCLUSIONS: The initial reduction in CBF due to elevated ICP, followed by reduction in CMRO, at the time of aneurysm rupture may play a role in the disturbance of CBF and cerebral metabolism in the acute stage of aneurysmal SAH.


Asunto(s)
Encéfalo/irrigación sanguínea , Metabolismo Energético/fisiología , Hemorragia Subaracnoidea/diagnóstico por imagen , Tomografía Computarizada de Emisión , Enfermedad Aguda , Anciano , Velocidad del Flujo Sanguíneo/fisiología , Volumen Sanguíneo/fisiología , Femenino , Escala de Coma de Glasgow , Humanos , Presión Intracraneal/fisiología , Masculino , Persona de Mediana Edad , Consumo de Oxígeno/fisiología , Hemorragia Subaracnoidea/fisiopatología , Vasoespasmo Intracraneal/diagnóstico por imagen , Vasoespasmo Intracraneal/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA