1.
J Alzheimers Dis ; 95(4): 1469-1480, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37718802

RESUMEN

BACKGROUND: Olfactory function decline has recently been reported to be associated with a risk of cognitive impairment. Few population-based studies have included younger adults when examining the association between olfactory test data with multiple odor intensities and suspected cognitive impairment. OBJECTIVE: We investigated the association between high-resolution olfactory test data with fewer odors and suspected cognitive impairments. We also examined the differences between older and younger adults in this association. METHODS: The Japanese version of the Montreal Cognitive Assessment (MoCA-J) was administered to 1,450 participants, with three odor-intensity-level olfactometry using six different odors. Logistic regressions to discriminate suspected cognitive impairment were conducted to examine the association, adjusted for age, sex, education duration, and smoking history. Data were collected from the Program by Tohoku University Tohoku Medical Megabank Organization, with an additional olfactory test conducted between 2019 and 2021. RESULTS: We generally observed that the lower the limit of distinguishable odor intensity was, the higher the MoCA-J score was. The combination of spearmint and stuffy socks contributed most to the distinction between suspected and unsuspected cognitive impairment. Furthermore, the association was significant in women aged 60-74 years (adjusted odds ratio 0.881, 95% confidence interval [0.790, 0.983], p = 0.024). CONCLUSIONS: The results indicate an association between the limit of distinguishable odor intensity and cognitive function. The olfactory test with multiple odor intensity levels using fewer odors may be applicable for the early detection of mild cognitive impairment, especially in older women aged 60-74 years.

2.
J Chromatogr A ; 1132(1-2): 256-9, 2006 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-16901495

RESUMEN

A novel apparatus with a simple structure has been developed for introducing samples into the vaporizing chamber of a gas chromatograph. It requires no septum due to the gas sealing structure over the carrier gas supply line. The septum-free injector made it possible to use injection port temperatures as high as 450 degrees C. Repetitive injection of samples with boiling points below 300 degrees C resulted in peak areas with relative standard deviations between 1.25 and 3.28% (n=5) and good linearity (r(2)>0.9942) for the calibration curve. In the analysis of polycyclic aromatic hydrocarbons and a base oil, the peak areas of components with high boiling points increased as the injection port temperature was increased to 450 degrees C.


Asunto(s)
Cromatografía de Gases/instrumentación , Cromatografía de Gases/métodos , Calibración , Hidrocarburos Policíclicos Aromáticos/análisis , Hidrocarburos Policíclicos Aromáticos/química , Temperatura de Transición