Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Bioresour Technol ; 151: 12-8, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24189380

RESUMEN

Substitution of conventional feedstock with waste based alternatives is one route towards both remediation and reducing costs associated with production of algal biomass. This work explores whether exhaust gases and wastewater can replace conventional feedstock in the production of biomass from Chlorella sorokiniana. Exhaust gases were used to augment production in final effluent, anaerobic digester centrate or in standard medium. Cultures were grown in 1L bottles under illumination of 80 µmol m(-2) s(-1). The results showed an average µmax ranging between 0.04 and 0.07 h(-1), whilst the final biomass yield in different media ranged between 220 and 330 mg L(-1). Lipid yield was increased over time to 31 mg L(-1). CO2 addition resulted in complete nitrogen removal between 48 and 96 h in both final effluent and centrate. The results also indicated that levels of carbon monoxide, carbon dioxide and nitrogen oxides in the exhaust gases can be reduced by between 20% and 95%.


Asunto(s)
Chlorella/metabolismo , Restauración y Remediación Ambiental/métodos , Gases/farmacología , Lípidos/biosíntesis , Emisiones de Vehículos , Aguas Residuales/microbiología , Biodegradación Ambiental/efectos de los fármacos , Chlorella/efectos de los fármacos , Chlorella/crecimiento & desarrollo , Medios de Cultivo/farmacología , Conductividad Eléctrica , Concentración de Iones de Hidrógeno/efectos de los fármacos , Nitrógeno/aislamiento & purificación , Fósforo/aislamiento & purificación
3.
IEEE Trans Med Imaging ; 27(4): 425-41, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18390341

RESUMEN

A critical issue in image restoration is the problem of noise removal while keeping the integrity of relevant image information. Denoising is a crucial step to increase image quality and to improve the performance of all the tasks needed for quantitative imaging analysis. The method proposed in this paper is based on a 3-D optimized blockwise version of the nonlocal (NL)-means filter (Buades, et al., 2005). The NL-means filter uses the redundancy of information in the image under study to remove the noise. The performance of the NL-means filter has been already demonstrated for 2-D images, but reducing the computational burden is a critical aspect to extend the method to 3-D images. To overcome this problem, we propose improvements to reduce the computational complexity. These different improvements allow to drastically divide the computational time while preserving the performances of the NL-means filter. A fully automated and optimized version of the NL-means filter is then presented. Our contributions to the NL-means filter are: 1) an automatic tuning of the smoothing parameter; 2) a selection of the most relevant voxels; 3) a blockwise implementation; and 4) a parallelized computation. Quantitative validation was carried out on synthetic datasets generated with BrainWeb (Collins, et al., 1998). The results show that our optimized NL-means filter outperforms the classical implementation of the NL-means filter, as well as two other classical denoising methods [anisotropic diffusion (Perona and Malik, 1990)] and total variation minimization process (Rudin, et al., 1992) in terms of accuracy (measured by the peak signal-to-noise ratio) with low computation time. Finally, qualitative results on real data are presented .


Asunto(s)
Algoritmos , Artefactos , Encéfalo/anatomía & histología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
4.
Artículo en Inglés | MEDLINE | ID: mdl-16685872

RESUMEN

We propose to segment Multiple Sclerosis (MS) lesions overtime in multidimensional Magnetic Resonance (MR) sequences. We use a robust algorithm that allows the segmentation of the abnormalities using the whole time series simultaneously and we propose an original rejection scheme for outliers. We validate our method using the BrainWeb simulator. To conclude, promising preliminary results on longitudinal multi-sequences of clinical data are shown.


Asunto(s)
Encéfalo/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Esclerosis Múltiple/diagnóstico , Reconocimiento de Normas Patrones Automatizadas/métodos , Algoritmos , Inteligencia Artificial , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
5.
Neuroimage ; 19(4): 1337-48, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12948692

RESUMEN

Within the scope of three-dimensional brain imaging, we propose an interindividual fusion scheme to register functional activations according to anatomical cortical structures, the sulci. This paper is based on the assumption that an important part of functional intersubject variability is encoded in anatomical variability. The aim of this paper is therefore to propose a generic framework to register functional activations according to the relevant anatomical landmarks. Compared to "classical" interindividual fusion schemes, this approach is local. It relies on a statistical sulci shape model accounting for the interindividual variability of a population of subjects and providing deformation modes relative to a reference shape (a mean sulcus). The deformation field obtained between a given sulcus and the reference sulcus is extended to a neighborhood of the given sulcus by using the thin-plate spline interpolation. It is then applied to functional activations located in the vicinity of this sulcus. This approach is compared with rigid and nonrigid registration methods. In this paper, we present results on MEG somatosensory data acquired on 18 subjects. We show that the nonlinear local fusion scheme significantly reduces the observed functional variability.


Asunto(s)
Mapeo Encefálico/métodos , Corteza Cerebral/fisiología , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Magnetoencefalografía/métodos , Dinámicas no Lineales , Adulto , Simulación por Computador , Dominancia Cerebral/fisiología , Potenciales Evocados Somatosensoriales/fisiología , Humanos , Masculino , Cómputos Matemáticos , Persona de Mediana Edad , Modelos Estadísticos , Valores de Referencia
6.
IEEE Trans Med Imaging ; 22(9): 1120-30, 2003 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12956267

RESUMEN

Although numerous methods to register brains of different individuals have been proposed, no work has been done, as far as we know, to evaluate and objectively compare the performances of different nonrigid (or elastic) registration methods on the same database of subjects. In this paper, we propose an evaluation framework, based on global and local measures of the relevance of the registration. We have chosen to focus more particularly on the matching of cortical areas, since intersubject registration methods are dedicated to anatomical and functional normalization, and also because other groups have shown the relevance of such registration methods for deep brain structures. Experiments were conducted using 6 methods on a database of 18 subjects. The global measures used show that the quality of the registration is directly related to the transformation's degrees of freedom. More surprisingly, local measures based on the matching of cortical sulci did not show significant differences between rigid and non rigid methods.


Asunto(s)
Corteza Cerebral/anatomía & histología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas , Técnica de Sustracción , Adulto , Encéfalo/anatomía & histología , Bases de Datos Factuales , Humanos , Interpretación de Imagen Asistida por Computador/normas , Imagen por Resonancia Magnética/normas , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Método Simple Ciego
7.
Med Image Anal ; 5(3): 185-94, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11524225

RESUMEN

This paper presents a strategy for the segmentation of brain from volumetric MR images which integrates 3D segmentation and 3D registration processes. The segmentation process is based on the level set formalism. A closed 3D surface propagates towards the desired boundaries through the iterative evolution of a 4D implicit function. In this work, the propagation relies on a robust evolution model including adaptive parameters. These depend on the input data and on statistical distribution models. The main contribution of this paper is the use of an automatic registration method to initialize the surface, as an alternative solution to manual initialization. The registration is achieved through a robust multiresolution and multigrid minimization scheme. This coupling significantly improves the quality of the method, since the segmentation is faster, more reliable and fully automatic. Quantitative and qualitative results on both synthetic and real volumetric brain MR images are presented and discussed.


Asunto(s)
Algoritmos , Encéfalo/anatomía & histología , Imagen por Resonancia Magnética/métodos , Humanos , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador
8.
IEEE Trans Med Imaging ; 20(5): 388-402, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11403198

RESUMEN

A new method for medical image registration is formulated as a minimization problem involving robust estimators. We propose an efficient hierarchical optimization framework which is both multiresolution and multigrid. An anatomical segmentation of the cortex is introduced in the adaptive partitioning of the volume on which the multigrid minimization is based. This allows to limit the estimation to the areas of interest, to accelerate the algorithm, and to refine the estimation in specified areas. At each stage of the hierarchical estimation, we refine current estimate by seeking a piecewise affine model for the incremental deformation field. The performance of this method is numerically evaluated on simulated data and its benefits and robustness are shown on a database of 18 magnetic resonance imaging scans of the head.


Asunto(s)
Simulación por Computador/estadística & datos numéricos , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Simulación por Computador/clasificación , Densitometría , Humanos , Procesamiento de Imagen Asistido por Computador/clasificación , Imagen por Resonancia Magnética/estadística & datos numéricos , Fantasmas de Imagen , Sensibilidad y Especificidad , Diseño de Software
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA