Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Biomech (Bristol, Avon) ; 120: 106365, 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39454313

RESUMEN

BACKGROUND: Individuals with transhumeral limb loss have an increased risk of falling, potentially resulting from altered upper-body kinematics during gait. The purpose of this study was to investigate whole-body angular momentum as a measure of movement control, to gain an understanding of how these upper-body kinematics contribute to dynamic balance. METHODS: Eight participants with transhumeral limb loss and eight able-bodied control participants completed three gait trials at self-selected speeds. The participants with transhumeral limb loss performed trials with and without their prosthesis. Coefficient of cancellation and whole-body angular momentum about all anatomical axes of rotation were calculated. Means and variance were compared across the conditions over the gait cycle via statistical parametric mapping, and ranges were compared using a one-way ANOVA. FINDINGS: Coefficient of cancellation was decreased between the upper/lower extremities in the transverse plane and between the upper extremities/trunk in the sagittal plane for both transhumeral walking conditions compared to the control group. Whole-body angular momentum was statistically different in the sagittal plane and decreased in the transverse plane when walking with the prosthesis compared to the control group. Walking without the prosthesis resulted in increased variability of whole-body angular momentum. INTERPRETATION: Individuals with transhumeral limb loss had dysregulated whole-body angular momentum compared to the control group. This dysregulation was related to decreased segment-to-segment cancellation from the upper extremities and increased variance throughout the gait cycle. Based on these findings, individuals should be encouraged to wear their transhumeral prosthesis while walking as it may reduce fall risk and fatigue.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39369948

RESUMEN

BACKGROUND: Humeral distalization is inherent to reverse total shoulder arthroplasty (rTSA) and is often produced with concomitant humeral lateralization via the level of the humeral head cut, implant positioning, implant neck shaft angle, and polymer insert thickness. Biomechanical data on the isolated effects of humeral distalization remain limited but could be important to consider when optimizing postoperative rTSA shoulder function. This study investigated the effects of isolated humeral distalization on shoulder biomechanics using a biorobotic shoulder simulator. METHODS: Eight fresh-frozen cadaveric shoulders were tested using custom polymer inserts that translated the bearing surface 0, +5, +10, and +15 mm along the humeral stem axis, producing isolated distalization without lateralization. Specimens underwent passive elevation in the scapular plane with a static scapula to assess glenohumeral range of motion. Scapular plane abduction motion trajectories were then performed, driven by previously collected scapulothoracic and glenohumeral kinematics from rTSA patients. The effect of isolated distalization on passive elevation was tested using mixed-effects linear regression and the effect on muscle force, joint reaction force, and muscle excursion during active scapular-plane abduction was tested using statistical parametric mapping random effects analysis. RESULTS: Maximum passive scapular plane elevation increased with humeral distalization (4° per 5 mm distalization). During active elevation, deltoid and rotator cuff muscle forces, and joint reaction forces, increased up to 37% per 5 mm of distalization. Simulated deltoid muscle excursion was altered with increasing distalization but amounted to no more than 0.8 mm change from baseline per 5 mm of distalization. Rotator cuff muscles were consistently lengthened throughout abduction, up to 1.6 mm per 5 mm of distalization. These trends were observed across various patient motions. CONCLUSIONS: Isolated humeral distalization caused dramatic increases in the muscle forces required to perform scapular-plane abduction. Joint reaction forces increased correspondingly. These results suggest that implant and surgical strategies to generate deltoid muscle tension without humeral distalization may promote better active range of motion and more durable long-term outcomes over approaches that rely on distalization.

3.
bioRxiv ; 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-39314362

RESUMEN

The biological factors that affect healing after rotator cuff repair (RCR) are not well understood. Genetic variants in the extracellular matrix protein Tenascin C (TNC) are associated with impaired tendon healing and it is expressed in rotator cuff tendon tissue after injury, suggesting it may have a role in the repair process. The purpose of the current study was to determine the role of TNC on tendon healing after RCR in a murine model. The supraspinatus tendon was transected and repaired on the left shoulder of Wild-Type (WT-RCR), Tenascin C null (Tnc --RCR) and Tnc heterozygous (Tnc +/--RCR) mice. Controls included the unoperated, contralateral shoulder of WT-RCR, Tnc - RCR, Tnc +/--RCR mice and unoperated shoulders from age and genotype matched controls. We performed histologic, activity testing, RNA-seq, and biomechanical analyses. At 8-weeks post-RCR, Tnc - and Tnc +/- mice had severe bone and tendon defects following rotator cuff repair. Tnc --RCR mice had reduced activity after rotator cuff repair including reduced wheel rotations, wheel duration, and wheel episode average velocity compared with WT-RCR. Loss of Tnc following RCR altered gene expression in the shoulder, including upregulation of sex hormone and WNT pathways and a downregulation of inflammation and cell cycle pathways. Tnc - mice had similar biomechanical properties after repair as WT. Further research is required to evaluate tissue specific alterations of Tnc, the interactions of Tnc and sex hormone and inflammation pathways as well as possible adjuvants to improve enthesis healing in the setting of reduced TNC function.

4.
Orthop J Sports Med ; 12(5): 23259671241245127, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38799548

RESUMEN

Background: Recently, all-suture, all-inside meniscal repair devices-including devices containing flat sutures or tapes-have been introduced. Similar to those in suture anchors, these modifications may have different performance characteristics than conventional sutures and polyether ether ketone (PEEK)-anchored devices. Purpose: To compare the biomechanical characteristics of all-suture meniscal repair devices with those of a conventional PEEK-anchored device and an inside-out meniscal suture construct. Study Design: Controlled laboratory study. Methods: A total of 48 adult porcine menisci with simulated bucket-handle tears were included. Single-device repairs were performed with the SuperBall Meniscal Repair System, FiberStitch, and FAST-FIX 360 with 2 PEEK anchors, and a vertical mattress inside-out suture repair was performed using a Ti-Cron No. 2-0 braided polyethylene terephthalate suture. All specimens were preloaded (10 N) and cycled 200 times (between 10 and 50 N). Specimens surviving cyclic loading were then destructively tested. Endpoints included maximum failure load, stiffness, cyclic displacement, and failure mode. The goal was 12 successful tests in each group. Metrics between groups were compared using analysis of variance with post hoc tests to control for multiple comparisons. Results: The SuperBall (108.9 N) was significantly stronger than the FAST-FIX 360 (67.3 N) and Ti-Cron (75.2 N), and the FiberStitch (102.8 N) was significantly stronger than the FAST-FIX 360 (P≤ .01 for all). Cyclic stiffness increased during cyclic loading for all constructs (P < .001). The Ti-Cron was significantly stiffer than the SuperBall during 5 to 200 cycles (P < .001). Cyclic displacement significantly increased in all constructs during cycling (P < .001) but did not differ between devices. Failure mode varied by device: the Ti-Cron repairs failed because of suture breakage, the SuperBall and FAST-FIX 360 failed at the anchor, and the FiberStitch showed both failure modes. Conclusion: The all-suture, all-inside meniscal repair devices demonstrated superior strength to the PEEK-anchored device and the classic inside-out suture meniscal repair but no statistically significant difference in cyclic displacement.

5.
Gait Posture ; 112: 59-66, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38744022

RESUMEN

BACKGROUND: Transhumeral (TH) limb loss leads to loss of body mass and reduced shoulder range of motion. Despite most owning a prosthesis, prosthesis abandonment is common. The consequence of TH limb loss and prosthesis use and disuse during gait may be compensation in the upper body, contributing to back pain or injury. Understanding the impact of not wearing a TH prosthesis on upper body asymmetries and spatial-temporal aspects of gait will inform how TH prosthesis use and disuse affects the body. RESEARCH QUESTION: Does TH limb loss alter upper body asymmetries and spatial-temporal parameters during gait when wearing and not wearing a prosthesis compared to able-bodied controls? METHODS: Eight male TH limb loss participants and eight male control participants completed three gait trials at self-selected speeds. The TH limb loss group performed trials with and without their prosthesis. Arm swing, trunk angular displacement, trunk-pelvis moment, and spatial-temporal aspects were compared using non-parametric statistical analyses. RESULTS: Both TH walking conditions showed greater arm swing in the intact limb compared to the residual (p≤0.001), resulting in increased asymmetry compared to the control group (p≤0.001). Without the prosthesis, there was less trunk flexion and lateral flexion compared to the control group (p≤0.001). Maximum moments between the trunk and pelvis were higher in the TH group than the control group (p≤0.05). Spatial-temporal parameters of gait did not differ between the control group and either TH limb loss condition. SIGNIFICANCE: Prosthesis use affects upper body kinematics and kinetics, but does not significantly impact spatial-temporal aspects of gait, suggesting these are compensatory actions. Wearing a prosthesis helps achieve more normative upper body kinematics and kinetics than not wearing a prosthesis, which may help limit back pain. These findings emphasize the importance of encouraging at least passive use of prostheses for individuals with TH limb loss.


Asunto(s)
Miembros Artificiales , Marcha , Humanos , Masculino , Fenómenos Biomecánicos , Marcha/fisiología , Adulto , Rango del Movimiento Articular/fisiología , Húmero/fisiología , Persona de Mediana Edad , Amputados/rehabilitación , Extremidad Superior/fisiología , Estudios de Casos y Controles
6.
J Biomech ; 166: 112054, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38513398

RESUMEN

The objective of this study was to define targeted reaching performance without visual information for transhumeral (TH) prosthesis users, establishing baseline information about extended physiological proprioception (EPP) in this population. Subjects completed a seated proprioceptive targeting task under simultaneous motion capture, using their prosthesis and intact limb. Eight male subjects, median age of 58 years (range 29-77 years), were selected from an ongoing screening study to participate. Five subjects had a left-side TH amputation, and three a right-side TH amputation. Median time since amputation was 9 years (range 3-54 years). Four subjects used a body-powered prosthetic hook, three a myoelectric hand, and one a myoelectric hook. The outcome measures were precision and accuracy, motion of the targeting hand, and joint angular displacement. Subjects demonstrated better precision when targeting with their intact limb compared to targeting with their prosthesis, 1.9 cm2 (0.8-3.0) v. 7.1 cm2 (1.3-12.8), respectively, p = 0.008. Subjects achieved a more direct reach path ratio when targeting with the intact limb compared to with the prosthesis, 1.2 (1.1-1.3) v. 1.3 (1.3-1.4), respectively, p = 0.039 The acceleration, deceleration, and corrective phase durations were consistent between conditions. Trunk angular displacement increased in flexion, lateral flexion, and axial rotation while shoulder flexion decreased when subjects targeted with their prosthesis compared to the intact limb. The differences in targeting precision, reach patio ratio, and joint angular displacements while completing the targeting task indicate diminished EPP. These findings establish baseline information about EPP in TH prosthesis users for comparison as novel prosthesis suspension systems become more available to be tested.


Asunto(s)
Miembros Artificiales , Extremidad Superior , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Implantación de Prótesis , Amputación Quirúrgica , Propiocepción , Diseño de Prótesis
7.
J Orthop Res ; 42(2): 259-266, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37756152

RESUMEN

Failure of healing after rotator cuff repair (RCR) is common. The purpose of the current study was to evaluate the effect of systemic estrogen or testosterone supplementation on tendon healing after RCR. Seventy-two adult male mice were utilized for all experiments. The supraspinatus tendon was transected and repaired with 6-0 Prolene suture on the left shoulder of 51 animals. Mice were segregated into three groups postoperative: (1) vehicle group (VG; n = 18), (2) estrogen group (EST; n = 17), and (3) testosterone group (TST; n = 16). An unrepaired control group (unrepaired, n = 21) did not have surgery. Utilizing these animals, histological analysis, activity testing, biomechanical testing and RNA sequencing (RNA-seq) was performed. At 8 weeks post-RCR, TST, and EST supplementation improved the overall histologic structure of the repaired enthesis site. No differences in ultimate failure loads or stiffness were detected between VG, EST, and TST groups after biomechanical testing. RCR caused a reduction in wheel activity compared to unrepaired controls and supplementation with TST restored wheel activity. RNA-seq analysis indicated that estrogen and testosterone regulated different pathways associated with enthesis healing, including a suppression of inflammatory signaling. Supplementation with sex hormones improved the structure of the repaired tendon enthesis and significantly regulated expression of diverse pathways regulating multiple biological processes. Testosterone administration following RCR restored wheel activity without having a detrimental impact on biomechanical strength. Future human studies of sex hormone supplementation after RCR are warranted as supplementation in an animal model may improve tendon enthesis healing.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Masculino , Ratones , Animales , Manguito de los Rotadores/patología , Lesiones del Manguito de los Rotadores/tratamiento farmacológico , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/patología , Testosterona/farmacología , Testosterona/uso terapéutico , Tendones/cirugía , Estrógenos/uso terapéutico , Estrógenos/farmacología , Suplementos Dietéticos , Fenómenos Biomecánicos
8.
J Am Acad Orthop Surg ; 32(8): e378-e386, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-37797249

RESUMEN

BACKGROUND: The purpose of this study was to determine whether preoperative planning software (PPS) accurately predicts clinical range of motion (ROM) in patients with reverse total shoulder arthroplasty 1 year postoperatively with preoperative and postoperative computed tomography (CT) scans. METHODS: This was a retrospective study of 16 reverse total shoulder arthroplasty patients with preoperative and postoperative (CT) scans obtained at least 1 year postoperatively. Clinical ROM was measured in abduction, external rotation at resting abduction, extension, and flexion at a minimum of 1 year postoperatively. All clinical measurements were obtained before generation of PPS ROM values. Using postoperative CT scans, the achieved implant component positions were quantified and then replicated in PPS on the preoperative CT scans. The preoperative predicted ROM was then recorded, both with and without osteophyte removal. Bland-Altman plots were generated within each motion comparing the differences between clinically measured motion and software-predicted motion. RESULTS: The variation in clinically measured ROM in abduction, external rotation at resting abduction, extension, and flexion were 118 ± 27 (65° to 180°), 33 ± 16 (10° to 75°), 56 ± 8 (50° to 65°), and 137 ± 25 (80° to 160°), respectively. Clinically measured motion differed greatly from PPS-predicted ROM, with mean differences of 33 ± 29 (-32 to 93) for abduction, 44 ± 25 (-38 to 57) for external rotation, 44 ± 25 (-35 to 65) for extension, and 54 ± 50 (-51 to 147) for flexion with no significant correlations between clinically measured and PPS-predicted ROM ( P > 0.05). With humeral or humeral and glenoid osteophyte resection, correlations for only flexion became significant ( P = 0.002 for both). CONCLUSION: The passive glenohumeral impingement-free ROM generated from PPS incompletely predicts clinically measured active humerothoracic ROM, possibly because of the unmeasured factors of soft-tissue tension, muscular strength, humeral torsion, resting scapular posture, and, most importantly, scapulothoracic motion. LEVEL OF EVIDENCE: IV.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteofito , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Estudios Retrospectivos , Osteofito/cirugía , Rango del Movimiento Articular , Programas Informáticos
9.
J Shoulder Elbow Surg ; 33(6): 1360-1365, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38122892

RESUMEN

BACKGROUND: One method to augment rotator cuff repair is to pass dermal allograft pledgets along the sutures that bridge from the medial to the lateral row. It remains unclear whether this augmentation method alters repair biomechanics. METHODS: This was a controlled laboratory study. After an a priori power analysis, 9 pairs of rotator cuffs underwent double-row suture bridge rotator cuff repair, half randomized to augmentation with dermal allograft pledgets passed along the suture bridge sutures. Repairs were then mounted on a material testing system and loaded cyclically 500 cycles to measure applied force and displacement. Repairs then underwent ultimate failure testing, and stiffness, ultimate failure force, and ultimate failure displacement were measured. Paired t tests were performed to compare between groups. RESULTS: There were no differences between groups in construct gapping with cyclic loading after 500 cycles (P = .885). There were no differences between the augmented and control groups in yield force (103.5 ± 5.0 vs. 101.4 ± 5.9 N, respectively, P = .183), stiffness (94.2 ± 13.9 vs. 90.9 ± 13.8, P = .585), or ultimate failure force (255.3 ± 65.8 vs. 285.3 ± 83.2, P = .315). There were no differences between groups in failure modes, with most specimens failing by cuff tissue tearing within or medial to the construct. CONCLUSION: The addition of dermal allograft pledgets does not positively or negatively influence the time-zero biomechanical characteristics of double-row suture bridge rotator cuff repair.


Asunto(s)
Lesiones del Manguito de los Rotadores , Técnicas de Sutura , Humanos , Lesiones del Manguito de los Rotadores/cirugía , Fenómenos Biomecánicos , Masculino , Manguito de los Rotadores/cirugía , Femenino , Aloinjertos , Persona de Mediana Edad , Anciano , Trasplante de Piel/métodos , Cadáver
10.
Artículo en Inglés | MEDLINE | ID: mdl-38036254

RESUMEN

BACKGROUND: Both inlay and onlay humeral implants are available for reverse total shoulder arthroplasty (rTSA), but biomechanical data comparing these components remain limited. This study investigated the effects of inlay and onlay rTSA humeral components on shoulder biomechanics using a biorobotic shoulder simulator. METHODS: Twenty fresh-frozen cadaveric shoulders were tested before and after rTSA with either an inlay or onlay humeral implant. Comparisons were performed between the most commonly implanted configurations for each implant (baseline) and with a modification to provide equivalent neck-shaft angles (NSAs) for the inlay and onlay configurations. Specimens underwent passive range-of-motion (ROM) assessment with the scapula held static, and scapular-plane abduction was performed, driven by previously collected human-subject scapulothoracic and glenohumeral kinematics. Passive ROM glenohumeral joint angles were compared using t tests, whereas muscle force and excursion data during scapular-plane elevation were evaluated with statistical parametric mapping and t tests. RESULTS: Maximum passive elevation was reduced for the inlay vs. onlay humeral components, although both implants caused reduced passive elevation vs. the native joint. Inlay rTSA also demonstrated reduced passive internal rotation at rest and increased external rotation at 90° of humerothoracic elevation vs. the native joint. All preoperative planning estimates of ROM differed from experiments. Rotator cuff forces were elevated with an onlay vs. inlay humeral implant, but simulated muscle excursions did not differ between systems. Compared with the native joint, rotator cuff forces were increased for both inlay and onlay implants and deltoid forces were reduced for inlay implants. Muscle excursions were dramatically altered by rTSA vs. the native joint. Comparisons of inlay and onlay humeral implants with equivalent NSAs were consistent with the baseline comparisons. CONCLUSIONS: Rotator cuff forces required to perform scapular-plane abduction increase following rTSA using both inlay and onlay implants. Rotator cuff forces are lower with inlay implants compared with onlay implants, although inlay implants also result in reduced passive-elevation ROM. Deltoid forces are lower with inlay implants in comparison to the native joint but not with onlay implants. The differences between inlay and onlay components are largely unaffected by NSA, indicating that these differences are inherent to the inlay and onlay designs. In those patients with an intact rotator cuff, decreased rotator cuff forces to perform abduction with an inlay humeral implant compared with an onlay implant may promote improved long-term outcomes owing to reduced deltoid muscle fatigue when using an inlay implant.

11.
JSES Int ; 7(3): 485-492, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37266163

RESUMEN

Background: Posterior humeral head (HH) subluxation after anatomic total shoulder arthroplasty (aTSA) is associated with worse outcomes, but it is unclear how corrective glenoid reaming correlates with HH alignment and whether HH alignment changes over time. Therefore, it was aimed to analyze the relationship between HH alignment and the scapula following aTSA to identify anatomic and surgical factors that contribute to realignment of the HH, glenoid loosening, and clinical outcomes. Methods: Three-dimensional scapulohumeral alignment was assessed on three-dimensionally reconstructed computed tomography scans of 23 patients: preoperative (T0), 2 years post-aTSA (T1), and ≥5 years post-aTSA (T2). Anterior-posterior (AP), superior-inferior (SI), and medial-lateral offset measures of the HH center to the scapula were referenced to the HH diameter (scapulohumeral subluxation index). Glenoid version and inclination were measured at T0 and T1. Central peg osteolysis, rotator cuff fatty infiltration, and vault perforation were assessed on two-dimensional computed tomography. Relative Constant Score at T2 measured clinical outcome. Results: Glenoid correction correlated strongly with AP and SI position of the HH (r = 0.733 and r = 0.797, respectively). Each degree of retroversion correction resulted in 0.9% AP scapulohumeral subluxation index offset change toward anterior. Each degree of inclination correction to superior resulted in a 1.0% offset change toward superior. A gradual postoperative proximal (mean difference [MD], -3%; P = .019), anterior (MD, 2%; P = .025), and medial (MD, 3 mm; P < .001) HH migration was observed. Asymmetric progressive rotator cuff fatty infiltration was associated with the direction of change in AP alignment over time (odds ratio, 2.04; P = .046), with progressive subscapularis fatty infiltration as the primary factor associated with gradual anterior HH translation (odds ratio, 15.61; P = .028). Gradual HH medialization was an indicator of glenoid components at risk for loosening (difference between medians, 4 mm; P = .003). Osteolysis around the central glenoid peg was influenced by overcorrection of glenoid version (MD, 7°; P = .038). Preoperative glenoid inclination was the sole anatomical or surgical factor predicting clinical outcome, as larger inferior inclination at T0 was associated with worse relative Constant Score at T2 (P = .016). Conclusion: Corrective glenoid reaming was an effective surgical technique to correct HH alignment in the AP and SI direction. Gradual anterior HH translation after aTSA was associated with progressive subscapularis fatty infiltration, and substantial HH medialization was an important indicator for potential glenoid loosening. While postoperative glenoid version and AP HH alignment were important for radiographic outcome, preoperative glenoid inclination predicted clinical outcome, as larger preoperative inferior inclination resulted in worse clinical scores.

12.
J Shoulder Elbow Surg ; 32(5): 1095-1104, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36586508

RESUMEN

BACKGROUND: The glenoid labrum acts as a bumper, deepening glenoid concavity and amplifying the concavity-compression mechanism, and serves as the scapular attachment for glenohumeral ligaments. The role of the posterosuperior labrum in anteroinferior glenohumeral stability, and the role of the anterior labrum in posterior stability has been debated. The purpose of this study was to quantify the contribution of anteroinferior and posterosuperior labral tears to loss of glenohumeral stability in multiple directions. METHODS: Fourteen fresh-frozen cadaveric shoulders were tested on a custom stability ratio measurement apparatus. The peak force that was required to translate the humeral head in anterior, anteroinferior, posterior, and posteroinferior directions was measured under 5 conditions: intact labrum (n = 14), anteroinferior labral tear (n = 7), posterosuperior labral tear (n = 7), combined labral tear (n = 14), and no labrum (n = 14). The stability ratio was defined as the peak translational force divided by the compressive force. Within force-translation curves, we defined the suction cup effect as the force required to release the negative pressure created by an intact labrum. RESULTS: The suction cup effect was usually present with the intact labrum and always disappeared after removal of the labrum for anterior (100% vs. 0%) and posterior (86% vs. 0%) translations (P < .001). After creation of an anteroinferior labral tear, the stability ratio for posterior direction decreased (P < .001) and the suction cup effect disappeared (P < .001). After creation of a posterosuperior labral tear, stability ratios in the anterior and anteroinferior directions decreased (P ≤ .006) and the suction cup effect disappeared (P ≤ .015). The stability ratio for anterior and anteroinferior testing was more diminished by posterosuperior labral tears than anteroinferior labral tears, and the stability ratio for posterior testing was more diminished by anteroinferior labral tears than posterosuperior labral tears. CONCLUSION: Anteroinferior labral tears decreased posterior stability and posterosuperior labral tears decreased anterior and anteroinferior stability, largely because of loss of the suction cup effect.


Asunto(s)
Laceraciones , Lesiones del Hombro , Articulación del Hombro , Humanos , Succión , Hombro , Rotura , Cadáver
13.
J Shoulder Elbow Surg ; 32(1): 33-40, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35961497

RESUMEN

BACKGROUND: Although muscle weakness and/or imbalance of the rotator cuff are thought to contribute to the development of shoulder instability, the association between muscular dysfunction and shoulder instability is not completely understood. The purpose of this study was to evaluate rotator cuff and deltoid muscle cross-sectional areas in different types of shoulder instability (anterior, posterior, and multidirectional instability [MDI]) and to determine the associations between muscular imbalance and shoulder instability direction. METHODS: Preoperative magnetic resonance images of patients with shoulder instability who subsequently underwent arthroscopic glenohumeral labral repair or capsular plication were evaluated. Shoulder instability was classified into 3 categories by direction: (1) anterior, (2) posterior, and (3) MDI. The rotator cuff (supraspinatus, subscapularis, and infraspinatus + teres minor) and deltoid (anterior and posterior portions, and total) muscle areas were measured on T1 sagittal and axial slices, respectively. The ratios of the subscapularis to infraspinatus + teres minor area and the anterior deltoid to posterior deltoid area were calculated to quantify the transverse force couple imbalance. RESULTS: A total of 189 patients were included, where each group consisted of 63 patients. The infraspinatus + teres minor muscle area was smaller than the subscapularis muscle area in the anterior instability group (P = .007). The subscapularis muscle area was smaller than the infraspinatus + teres minor muscle area in the posterior instability and MDI groups (P ≤ .003). The anterior deltoid muscle area was smaller than the posterior deltoid muscle area in all groups (P ≤ .001). The subscapularis-to-infraspinatus + teres minor area ratio in the anterior instability group (1.18 ± 0.40) was higher than that in the posterior instability and MDI groups (0.79 ± 0.31 and 0.93 ± 0.33, respectively; P < .001). There was no difference in the anterior deltoid-to-posterior deltoid area ratio among the 3 groups. CONCLUSION: Patients with anterior instability have smaller muscle area of the posterior rotator cuff as compared with the anterior rotator cuff. In contrast, patients with posterior instability and MDI have smaller muscle area of the anterior rotator cuff as compared with the posterior rotator cuff. Thus, the direction of shoulder instability is associated with rotator cuff muscle area.


Asunto(s)
Inestabilidad de la Articulación , Lesiones del Manguito de los Rotadores , Articulación del Hombro , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Manguito de los Rotadores/patología , Hombro , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Articulación del Hombro/fisiología , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/patología
14.
J Shoulder Elbow Surg ; 32(4): e133-e144, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36343789

RESUMEN

BACKGROUND: Internal rotation in adduction is often limited after reverse total shoulder arthroplasty (rTSA), but the origins of this functional deficit are unclear. Few studies have directly compared individuals who can and cannot perform internal rotation in adduction. Little data on underlying 3D humerothoracic, scapulothoracic, and glenohumeral joint relationships in these patients are available. METHODS: Individuals >1-year postoperative to rTSA were imaged with biplane fluoroscopy in resting neutral and internal rotation in adduction poses. Subjects could either perform internal rotation in adduction with their hand at T12 or higher (high, N = 7), or below the hip pocket (low, N = 8). Demographics, the American Shoulder and Elbow Surgeons score, Simple Shoulder Test, and scapular notching grade were recorded. Joint orientation angles were derived from model-based markerless tracking of the scapula and humerus relative to the torso. The 3D implant models were aligned to preoperative computed tomography models to evaluate bone-implant impingement. RESULTS: The Simple Shoulder Test was highest in the high group (11 ± 1 vs. 9 ± 2, P = .019). Two subjects per group had scapular notching (grades 1 and 2), and 3 high group and 4 low group subjects had impingement below the glenoid. In the neutral pose, the scapula had 7° more upward rotation in the high group (P = .100), and the low group demonstrated 9° more posterior tilt (P = .017) and 14° more glenohumeral elevation (P = .047). In the internal rotation pose, axial rotation was >45° higher in the high group (P ≤ .008) and the low group again had 11° more glenohumeral elevation (P = .058). Large rotational differences within subject groups arose from a combination of differences in the resting neutral and maximum internal rotation in adduction poses, not only the terminal arm position. CONCLUSIONS: Individuals who were able to perform high internal rotation in adduction after rTSA demonstrated differences in joint orientation and anatomic biases versus patients with low internal rotation. The high rotation group had 7° more resting scapular upward rotation and used a 15°-30° change in scapular tilt to perform internal rotation in adduction versus patients in the low group. The combination of altered resting scapular posture and restricted scapulothoracic range of motion could prohibit glenohumeral rotation required to reach internal rotation in adduction. In addition, inter-patient variation in humeral torsion may contribute substantially to postoperative internal rotation differences. These data point toward modifiable implant design and placement factors, as well as foci for physical therapy to strengthen and mobilize the scapula and glenohumeral joint in response to rTSA surgery.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Hombro/cirugía , Escápula , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Articulación del Hombro/fisiología , Fluoroscopía , Rango del Movimiento Articular/fisiología , Fenómenos Biomecánicos
15.
Arch Orthop Trauma Surg ; 143(1): 203-211, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34223973

RESUMEN

INTRODUCTION: The purpose of this study was to determine if "off-track" Hill-Sachs lesions in patients with dynamic anteroinferior instability were transformed into "on-track" lesions using iliac bone autografts with screw fixation. The secondary purpose was to observe if postoperative bony remodeling would occur over time, resulting in recurrent "off-track" Hill-Sachs lesions with corresponding instability. MATERIALS AND METHODS: We retrospectively reviewed clinical and CT records of 8 patients with an "off-track" Hill-Sachs lesion who underwent open anatomical glenoid reconstruction with an iliac crest bone autograft. Hill-Sachs lesions, glenoid track widths, and glenoid surface areas were measured on a preoperative and two postoperative (6 weeks, ≥ 2 years) 3D-CT models to determine graft resorption over time. All patients were available for postoperative clinical and CT final follow-up 3 years (2-4 years) postoperatively. RESULTS: In all patients, the Hill-Sachs lesions were "on-track" 6 weeks postoperatively and remained "on-track" at final-follow-up. Compared to preoperative values, the glenoid track width and glenoid surface area both were higher 6 weeks postoperatively (p < 0.001 and p = 0.023, respectively) and at final follow-up (p < 0.001 and p = 0.023, respectively). Whereas the glenoid track width between 6 weeks and final follow-up showed no decrease (p = 0.234), glenoid surface area tended to decrease (p = 0.055). The median SSV was 93 points (85-95 points), the Rowe score 90 points (80-100 points) and the WOSI 1980 points (1783-2067 points) at final follow-up. No recurrent dislocations or subluxations were observed. CONCLUSIONS: An open anatomical glenoid reconstruction with an iliac crest bone autograft technique using screw fixation effectively transformed "off-track" Hill-Sachs lesions to "on-track" lesions, resulting in good short-term clinical outcomes. Whereas glenoid surface area tended to be reduced by bony remodeling processes over time, the glenoid track width did not decrease at final follow-up and consequently no recurrence of "off-track" lesions occurred. LEVEL OF EVIDENCE: Case series; Level of evidence, IV.


Asunto(s)
Lesiones de Bankart , Luxaciones Articulares , Inestabilidad de la Articulación , Luxación del Hombro , Articulación del Hombro , Humanos , Articulación del Hombro/cirugía , Luxación del Hombro/cirugía , Lesiones de Bankart/cirugía , Autoinjertos , Estudios Retrospectivos , Ilion , Inestabilidad de la Articulación/cirugía , Luxaciones Articulares/complicaciones , Artroscopía/métodos
16.
Orthop J Sports Med ; 10(10): 23259671221130700, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36338354

RESUMEN

Background: It is well known that glenoid osseous defects >13.5% of the glenoid width critically destabilize the shoulder, as do labral tears. Chondrolabral defects often occur with anterior dislocation of the shoulder. It is unclear whether glenoid chondrolabral defects contribute to shoulder stability and, if so, at what size they become critical. Purpose/Hypothesis: The purpose of this study was to determine the effect of incremental chondrolabral defect sizes on anterior shoulder stability in the setting of labral deficiency. The hypothesis was that chondrolabral defects ≥13.5% of the glenoid width will decrease anterior shoulder stability. Study Design: Controlled laboratory study. Methods: This controlled laboratory study tested 12 fresh-frozen shoulders. Specimens were attached to a custom testing device in abduction and neutral rotation with 50-N compression applied to the glenoid. The humeral head was translated 10 mm anterior, anteroinferior, and anterosuperior with the conditions of intact cartilage and labrum and anterior full-thickness chondrolabral defects of 3-, 6-, and 9-mm width. Translation force was measured continuously. Peak translation force divided by 50-N compressive force defined the stability ratio. Data were analyzed using analysis of variance. Results: The anterior stability ratio decreased between the intact state (36% ± 7%) and all defects ≥3 mm (≤32% ± 8%; P ≤ .023). The anteroinferior stability ratio decreased between the intact state (52% ± 7%) and all defects ≥3 mm (≤47% ± 7%; P ≤ .006). The anterosuperior stability ratio decreased between the intact state (36% ± 4%) and all defects ≥6 mm (≤33% ± 4%; P ≤ .006). A 3-mm defect equated to 10% of the glenoid width. There were moderate to strong negative correlations between chondrolabral defect size and stability ratio in the anterior, anteroinferior, and anterosuperior directions (r = -0.79, -0.63, and -0.58, respectively; P ≤ .001). There were moderate to strong negative correlations between the percentage of glenoid chondrolabral defect size to the glenoid width and the stability percentage in all directions (r = -0.81, -0.63, and -0.61; P ≤ .001). Conclusion: An anterior glenoid chondrolabral defect ≥3 mm (>10% of the glenoid width) significantly decreased anterior and anteroinferior stability. Chondrolabral defect size negatively correlated with stability. Clinical Relevance: To fully restore glenohumeral stability, in addition to labral repair, it may be necessary to reconstruct chondrolabral defects as small as 3 mm (10% of the glenoid width).

17.
Arch Rehabil Res Clin Transl ; 4(3): 100202, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36123975

RESUMEN

Objective: To develop and test an assessment measuring extended physiological proprioception (EPP). EPP is a learned skill that allows one to extend proprioception to an external tool, which is important for controlling prosthetic devices. The current study examines the ability of this assessment to measure EPP in a nonamputee population for translation into the affected population. Design: Measuring precision and accuracy of an upper extremity (UE) proprioceptive targeting task assessment. Participants completed 2 sessions of a targeting task while seated at a table. The targeting was completed with the dominant and nondominant hand and with eyes open and eyes closed during the task. Participants completed 2 sessions of the clinical test with a 1-week washout period to simulate reasonable time between clinical visits. Setting: Research laboratory. Participants: Twenty right-handed participants (N=20) with no neurologic or orthopedic deficits that would interfere with proprioception, median age of 25 years (range, 19-33 years), completed the assessment (10 men, 10 women). Interventions: Not applicable. Main Outcome Measures: Precision (consistency in targeting) and accuracy (distance between the intended target and participant result) in UE targeting task using EPP; test-retest repeatability between sessions. Results: Both precision and accuracy were significantly decreased in the eyes-closed condition compared with the eyes-open condition regardless of targeting with dominant or nondominant hand (all P<.001). In the eyes-open condition, there was a dominance effect relating to the accuracy; however, in the eyes-closed condition, accuracy between dominant and nondominant hands was statistically equivalent. Based on minimum detectable change with 95% confidence, there was no change in either metric between the first and second sessions. Conclusions: The results of this study support the feasibility of using this assessment to measure EPP-based on the definition of EPP as a learned skill that indicates control over an external, simple tool-because they demonstrate reliance on proprioception in the eyes-closed condition, symmetry in proprioceptive accuracy between hands for within-participant control, and test-retest reliability for longitudinal measurements. The results also establish normative values for this assessment in young, healthy adults. Further research is required in a clinical population to evaluate the UE proprioceptive targeting task assessment further and collect objective data on EPP.

18.
J Shoulder Elbow Surg ; 31(12): 2647-2656, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35931329

RESUMEN

BACKGROUND: Optimal implant placement in reverse total shoulder arthroplasty (rTSA) remains controversial. Specifically, the optimal glenoid inclination is unknown. Therefore, a cadaveric shoulder simulator with 3-dimentional human motion specific to rTSA was used to study joint contact and muscle forces as a function of glenoid component inclination. METHODS: Eight human cadaver shoulders were tested before and after rTSA implantation. Scapular plane abduction kinematics from control subjects and those with rTSA drove a cadaveric shoulder simulator with 3-dimentional scapulothoracic and glenohumeral motion. Glenoid inclination varied from -20° to +20°. Outputs included compression, superior-inferior (S/I) shear, and anterior-posterior shear forces from a 6° of freedom load cell in the joint, and deltoid and rotator cuff muscle forces. Data were evaluated with statistical parametric mapping and t-tests. RESULTS: Inferior glenoid inclination (-) reduced S/I shear by up to 125% relative to superior inclination, with similar compression to the neutral condition (0°). Superior inclinations (+) increased the S/I shear force by approximately the same magnitude, yet decreased compression by 25% in the most superior inclination (+20°). There were few differences in deltoid or rotator cuff forces due to inclination. Only the middle deltoid decreased by approximately 7% for the most inferior inclination (-20°). Compared with native shoulders, the neutral (0°) rTSA inclination showed reduced forces of 30%-75% in the anterior deltoid and a trend toward decreased forces in the middle deltoid. Force demands on the rotator cuff varied as a function of elevation, with a trend toward increased forces in rTSA at peak glenohumeral elevation. CONCLUSIONS: Inferior inclination reduces superior shear forces, without influencing compression. Superior inclination increased S/I shear, while decreasing compression, which may be a source of component loosening and joint instability after rTSA. Inferior inclination of the rTSA glenoid may reduce the likelihood of glenoid loosening by reducing the magnitude of cyclic shear and compressive loading during arm elevation activities, although this may be altered by specific-subject body habitus and motion. These factors are especially important in revision rTSA or glenoid bone grafting where there is already a 3-fold increase in glenoid baseplate loosening vs. primary rTSA.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Humanos , Hombro/cirugía , Escápula/cirugía , Fenómenos Biomecánicos , Cadáver , Rango del Movimiento Articular
19.
Clin Orthop Relat Res ; 480(11): 2254-2265, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-35857295

RESUMEN

BACKGROUND: Reverse total shoulder arthroplasty (rTSA) typically restores active arm elevation. Prior studies in patients with rTSA during tasks that load the arm had limitations that obscured underlying three-dimensional (3D) kinematic changes and the origins of motion restrictions. Understanding the scapulothoracic and glenohumeral contributions to loaded arm elevation will uncover where functional deficits arise and inform strategies to improve rTSA outcomes. QUESTIONS/PURPOSES: In a cohort of patients who had undergone rTSA and a control cohort, we asked: (1) Is there a difference in maximum humerothoracic elevation when scapular plane elevation (scaption) is performed with and without a handheld weight? (2) Is maximum humerothoracic elevation related to factors like demographics, patient-reported outcome scores, isometric strength, and scapular notching (in the rTSA group only)? (3) Are there differences in underlying 3D scapulothoracic and glenohumeral motion during scaption with and without a handheld weight? METHODS: Ten participants who underwent rTSA (six males, four females; age 73 ± 8 years) were recruited at follow-up visits if they were more than 1 year postoperative (24 ± 11 months), had a BMI less than 35 kg/m 2 (29 ± 4 kg/m 2 ), had a preoperative CT scan, and could perform pain-free scaption. Data from 10 participants with a nonpathologic shoulder, collected previously (five males, five females; age 58 ± 7 years; BMI 26 ± 3 kg/m 2 ), were a control group with the same high-resolution quantitative metrics available for comparison. Participants in both groups performed scaption with and without a 2.2-kg handheld weight while being imaged with biplane fluoroscopy. Maximum humerothoracic elevation and 3D scapulothoracic and glenohumeral kinematics across their achievable ROM were collected via dynamic imaging. In the same session the American Shoulder and Elbow Surgeons (ASES) score, the Simple Shoulder Test (SST), and isometric strength were collected. Data were compared between weighted and unweighted scaption using paired t-tests and linear mixed-effects models. RESULTS: When compared with unweighted scaption, maximum humerothoracic elevation decreased during weighted scaption for patients who underwent rTSA (-25° ± 30°; p = 0.03) but not for the control group (-2° ± 5°; p = 0.35). In the rTSA group, maximum elevation correlated with the ASES score (r = 0.72; p = 0.02), and weighted scaption correlated with BMI (r = 0.72; p = 0.02) and the SST (r = 0.76; p = 0.01). Scapular notching was observed in three patients after rTSA (Grades 1 and 2). Four of 10 patients who underwent rTSA performed weighted scaption to less than 90° humerothoracic elevation using almost exclusively scapulothoracic motion, with little glenohumeral contribution. This manifested as changes in the estimated coefficient representing mean differences in slopes in the humerothoracic plane of elevation (-12° ± 2°; p < 0.001) and true axial rotation (-16° ± 2°; p < 0.001), scapulothoracic upward rotation (7° ± 1°; p < 0.001), and glenohumeral elevation (-12° ± 1°; p < 0.001), plane of elevation (-8° ± 3°; p = 0.002), and true axial rotation (-11° ± 2°; p < 0.001). The control group demonstrated small differences between scaption activities (< |2°|), but a 10° increase in humerothoracic and glenohumeral axial rotation (both p < 0.001). CONCLUSION: After rTSA surgery, maximum humerothoracic elevation decreased during weighted scaption by up to 88° compared with unweighted scaption, whereas 4 of 10 patients could not achieve more than 90° of elevation. These patients exhibited appreciable changes in nearly all scapulothoracic and glenohumeral degrees of freedom, most notably a near absence of glenohumeral elevation during weighted scaption. Patients with rTSA have unique strategies to elevate their arms, often with decreased glenohumeral motion and resultant compensation in scapulothoracic motion. In contrast, the control group showed few differences when lifting a handheld weight. CLINICAL RELEVANCE: Functional deficiency in activities that load the shoulder after rTSA surgery can affect patient independence, and they may be prevalent but not captured in clinical studies. Pre- or postoperative rehabilitation to strengthen scapular stabilizers and the deltoid should be evaluated against postoperative shoulder function. Further study is required to determine the etiology of deficient glenohumeral motion after rTSA, and the most effective surgical and/or rehabilitative strategies to restore deficient glenohumeral motion after rTSA.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Anciano , Anciano de 80 o más Años , Artroplastía de Reemplazo de Hombro/efectos adversos , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Escápula/diagnóstico por imagen , Escápula/cirugía , Hombro , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía
20.
J Shoulder Elbow Surg ; 31(10): 2023-2033, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35550434

RESUMEN

BACKGROUND: Although typically favorable in outcome, anatomic total shoulder arthroplasty (aTSA) can require long-term revision. The most common cause for revision is glenoid loosening, which may result from eccentric cyclic forces and joint translations. "Rocking" of the glenoid component may be exacerbated by the joint geometry, such as glenoid inclination and version. Restoration of premorbid glenoid inclination may be preferable, although laboratory and computational models indicate that both superior inclination and inferior inclination have benefits. This discrepancy may arise because previous studies were limited by a lack of physiological conditions to test inclination. Therefore, a cadaveric shoulder simulator with 3-dimensional human motion was used to study joint contact and muscle forces with isolated changes in glenoid inclination. METHODS: Eight human cadaveric shoulders were tested before and after aTSA. Scapular-plane abduction kinematics from human subjects were used to drive a cadaveric shoulder simulator with 3-dimensional scapulothoracic and glenohumeral motion. Glenoid inclination was varied from -10° to +20°, whereas compressive, superior-inferior shear, and anterior-posterior shear forces were collected with a 6-df load cell during motion. Outputs also included muscle forces of the deltoid and rotator cuff. Data were evaluated with statistical parametric mapping repeated-measures analysis of variance and t tests. RESULTS: Inferior glenoid inclination (-10°) reduced both compressive and superior-inferior shear forces vs. neutral 0° inclination by up to 40%, and even more when compared with superior inclination (P < .001). Superior inclinations (+10° and +20°) tended to increase deltoid and rotator cuff forces vs. neutral 0° inclination or inferior inclination, on the order of 20%-40% (P ≤ .045). All force metrics except anterior-posterior shear were lowest for inferior inclination. Most aTSA muscle forces for neutral 0° inclination were not significantly different from native shoulders and decreased 45% and 15% in the posterior deltoid and supraspinatus, respectively (P ≤ .003). Joint translations were similar to prior reports in aTSA patients and did not differ between any inclinations or compared with native shoulders. Joint reaction forces were similar to those observed in human subjects with instrumented aTSA implants, providing confidence in the relative magnitude of our results. CONCLUSIONS: Inferior inclination reduces overall forces in the shoulder. Superior inclinations increase the muscle effort required for the shoulder to achieve similar motion, thus increasing the forces exerted on the glenoid component. These results suggest that a preference toward aTSA glenoid components in inferior inclination may reduce the likelihood of glenoid loosening by reducing excessive muscle and joint contact forces.


Asunto(s)
Articulación del Hombro , Hombro , Fenómenos Biomecánicos/fisiología , Cadáver , Humanos , Manguito de los Rotadores/fisiología , Escápula , Hombro/fisiología , Articulación del Hombro/fisiología , Articulación del Hombro/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA