Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Base de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
JACC Case Rep ; 10: 101760, 2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36974056

RESUMEN

The authors report a closed-chest, transcatheter large-vessel connection (hepatic conduit to azygous vein) to reverse pulmonary arteriovenous malformations in a 10-year-old patient after Fontan for heterotaxy/interrupted inferior vena cava, with an increase in oxygen saturation from 78% to 96%. Computational fluid dynamics estimated a 14-fold increase in hepatic blood flow to the left pulmonary artery (from 1.3% to 14%). (Level of Difficulty: Advanced.).

2.
J Invasive Cardiol ; 33(12): E978-E985, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34866050

RESUMEN

BACKGROUND: Intravascular ultrasound (IVUS) is a catheter-based imaging modality that generates cross-sectional views of vessel walls and lumens. This technique is used in adult interventional and vascular surgeries to guide the management of coronary artery and peripheral arterial disease. IVUS has been described as superior to angiography in providing data about lesions of interest, including degree of vessel stenosis and stent apposition following intervention. IVUS use to guide transcatheter management of congenital heart disease is limited. OBJECTIVE: We reviewed our experience using IVUS as an adjunctive tool to diagnose lesions and assess intervention in pediatric patients during cardiac catheterization. METHODS AND RESULTS: A retrospective chart review of all pediatric patients who underwent IVUS during cardiac catheterization to evaluate the cross-sectional lumen of non-coronary vessel(s) at Rady Children's Hospital from January 2018 to December 2019 was performed. Median patient age was 637 days (range, 44-4328 days), with mean weight of 12.1 ± 9 kg. Twenty-six vessels were interrogated with IVUS (pulmonary venous stenosis [n = 8], coarctation [n = 5], branch pulmonary artery stenosis [n = 6], systemic shunts and conduits [n = 3], and other peripheral vasculature [n = 4]). IVUS added value in all cases (100%). We found that IVUS guided the intervention in 88% of procedures and defined the endpoint in 62% of transcatheter interventions. There were no IVUS-related complications. CONCLUSIONS: IVUS enhanced our diagnostic interpretation and identified occult lesions not visualized by angiography. IVUS was valuable in guiding and defining the endpoints of these interventions.


Asunto(s)
Cardiología , Angiografía , Niño , Estudios Transversales , Humanos , Estudios Retrospectivos , Ultrasonografía Intervencional
3.
JACC Case Rep ; 2(11): 1734-1735, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33000000

RESUMEN

Limited arterial vascular access precluded necessary transcatheter intervention in a 22-year-old woman with repaired interrupted aortic arch type B. Alternative transcaval vascular access enabled percutaneous therapy. This practice evolution is likely to benefit the growing numbers of adults with congenital heart disease. (Level of Difficulty: Advanced.).

4.
Catheter Cardiovasc Interv ; 96(7): 1439-1444, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32979038

RESUMEN

OBJECTIVES: We intend to describe early experience using a new, commercially available Micro Plug Set for preterm neonate and infant transcatheter patent ductus arteriosus (PDA) occlusion. BACKGROUND: Transcatheter PDA occlusion in premature neonates and small infants is safe and effective. The procedure is early in its evolution. METHODS: Procedural and short-term outcomes of preterm neonates and infants undergoing transcatheter PDA occlusion with a new, commercially available device were reviewed. RESULTS: Eight preterm neonates and infants born at median 27 weeks gestation (23-36 weeks) underwent transcatheter PDA device closure with the Micro Plug Set. The device is short (2.5 mm) with a range of diameters (3, 4, 5, 6 mm) and delivered through a microcatheter. Procedures were performed at median 41 days of age (12-88 days) and at 1690 g (760-3,310 g). Transvenous PDA device occlusion was performed with fluoroscopic and echocardiography guidance. All procedures were successful with complete PDA occlusion. There were no procedural or short-term adverse events. CONCLUSIONS: Preterm neonate and infant transcatheter PDA device closure with a new, commercially available short and microcatheter delivered device (Micro Plug Set) was safe and effective in a small, early series of patients.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Conducto Arterioso Permeable/terapia , Peso al Nacer , Cateterismo Cardíaco/efectos adversos , Conducto Arterioso Permeable/diagnóstico por imagen , Conducto Arterioso Permeable/fisiopatología , Diseño de Equipo , Edad Gestacional , Humanos , Recién Nacido de Bajo Peso , Recién Nacido , Recien Nacido Prematuro , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento