Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 83(5): 729-38, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24323486

RESUMEN

OBJECTIVES: To evaluate practices for the protection from radiation of patients during coronary angiography (CA) and percutaneous coronary intervention (PCI), and to update reference values for the main radiation dose parameters. BACKGROUND: Few multicenter data from large populations exist on radiation doses to patients during CA and PCI. METHODS: RAY'ACT is a multicenter, nationwide French survey, with retrospective analysis of radiation parameters routinely registered in professional software from 33,937 CAs and 27,826 PCIs performed at 44 centers from January 1, through December 31, 2010. RESULTS: Kerma-area product (KAP) was registered in 91.7% (44/48) of centers and in 91.5% of procedures for CA (median, 27.2 Gy·cm(2) , interquartile range [IQR], 15.5-45.2) and 91.1% for PCI (median, 56.8 Gy·cm(2) , IQR, 32.8-94.6). Fluoroscopy time was registered in 87.5% (42/48) of centers and in 83.1% of procedures (median, 3.7 min, IQR, 2.3-6.3 for CA; 10.3 min, 6.7-16.2 for PCI). Variability across centers was high. Old equipment and routine left ventriculography were more common and number of registered frames and frame rate were higher in centers delivering high doses. The radial route was associated with lower doses than the femoral route (median KAP 26.8 Gy·cm(2) [15.1-44.25] vs. 28.1 [16.4-46.9] for CA, respectively; and 55.6 Gy·cm(2) [32.2-92.1] vs. 59.4 [24.6-99.9] for PCI, respectively; P < 0.01). CONCLUSIONS: This survey showed a very high rate of compliance with dose registration during CA and PCI in French nonacademic hospitals. Updated diagnostic reference values are established for the main dose parameters (KAP, 45 Gy·cm(2) for CA, 95 Gy·cm(2) for PCI).


Asunto(s)
Angiografía Coronaria , Intervención Coronaria Percutánea , Dosis de Radiación , Traumatismos por Radiación/prevención & control , Radiografía Intervencional , Anciano , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/normas , Femenino , Arteria Femoral/diagnóstico por imagen , Fluoroscopía , Francia , Adhesión a Directriz , Encuestas de Atención de la Salud , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/normas , Guías de Práctica Clínica como Asunto , Pautas de la Práctica en Medicina , Valor Predictivo de las Pruebas , Arteria Radial/diagnóstico por imagen , Traumatismos por Radiación/etiología , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/normas , Valores de Referencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
2.
J Emerg Med ; 42(4): e73-5, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19327932

RESUMEN

BACKGROUND: Acute coronary syndromes after hymenoptera stings and other environmental exposures are referred to as the Kounis syndrome or allergic myocardial ischemia and infarction. CASE REPORT: We report the case of a 58-year-old man with transient inferior ST-segment elevation consistent with myocardial ischemia after a single wasp sting. Urgent cardiac catheterization revealed normal coronary arteries with a normal left ventriculogram. The evaluation and treatment of cardiac ischemia associated with an allergic reaction is discussed. CONCLUSION: ST elevation myocardial infarction after wasp envenomation is an exceptional and interesting pathology with a partially elucidated pathogenesis. The management of cardiac ischemia in this setting is uncertain.


Asunto(s)
Mordeduras y Picaduras de Insectos/complicaciones , Infarto del Miocardio/etiología , Venenos de Avispas/efectos adversos , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad
3.
Intern Med ; 49(22): 2451-3, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21088348

RESUMEN

Retroperitoneal fibrosis is an uncommon collagen vascular disease of unknown etiology, characterized by the replacement of normal retroperitoneal tissue with fibrosis and/or chronic inflammation usually surrounding the abdominal aorta and the iliac arteries and extending into adjacent anatomic structures. No cases of acute coronary syndrome in the setting of retroperitoneal disorder have been published as yet. We report a 37-year-old man with a 14-year history of type I diabetes mellitus who was admitted to the endocrinology department for a routine check up and glycemic re-equilibration and who was later diagnosed to have an idiopathic retroperitoneal fibrosis. The patient presented during his hospitalisation with a non ST elevation myocardial infarction caused by an isolated thrombus located inside the left main coronary artery successfully treated with manual thrombectomy.


Asunto(s)
Trombosis Coronaria/etiología , Diabetes Mellitus Tipo 1/complicaciones , Fibrosis Retroperitoneal/complicaciones , Adulto , Humanos , Masculino , Factores de Tiempo
5.
J Electrocardiol ; 42(5): 414-9, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19376526

RESUMEN

ST-segment elevation during dobutamine stress echocardiography is a serious complication usually related to severe coronary artery disease. However, it can occur in absence of significant coronary artery disease supposedly as a consequence of an occlusive dobutamine-induced coronary artery spasm. We report the case of a 56-year-old man without cardiovascular history who presented during a dobutamine stress echocardiography an intense precordial pain along with an impressive 10-mm ST elevation and in whom urgent catheterization documented the absence of significant coronary artery stenoses.


Asunto(s)
Vasoespasmo Coronario/inducido químicamente , Vasoespasmo Coronario/diagnóstico , Vasos Coronarios/efectos de los fármacos , Dobutamina/efectos adversos , Electrocardiografía/efectos de los fármacos , Prueba de Esfuerzo/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico , Electrocardiografía/métodos , Humanos , Masculino , Persona de Mediana Edad , Vasodilatadores/efectos adversos
6.
Eur J Echocardiogr ; 10(4): 556-61, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19202147

RESUMEN

AIMS: The aim of this article was to assess whether abnormal dobutamine stress echocardiography (DSE) can be due to a dobutamine-induced coronary spasm in patients with angiographically documented vasospastic coronary arteries. METHODS AND RESULTS: Between January 2004 and April 2008, we prospectively evaluated all patients with known or suspected coronary artery disease (CAD) referred to the echocardiography laboratory for dobutamine stress tests (6061 examinations). Those with abnormal DSE underwent coronary angiogram with a systematic methylergometrine intracoronary injection in the case of absence of significant coronary stenosis or spontaneous occlusive coronary spasm. Patients who had spontaneous occlusive coronary spasm or positive methylergometrine test, but no significant stenoses, were ultimately included in this study. About 581 patients had abnormal DSE, among them only 20 (3.4%) fulfilled the inclusion criteria. There were 15 males and 5 females, and mean age was 64.35 years (range 52-85); 8 patients had a known history of CAD and all of them had at least two established cardiovascular risk factors. The culprit vessel was the left anterior descending artery in 10 cases (50%), right coronary artery in 8 cases (40%), and left circumflex in 2 cases (10%). There was a systematic correspondence between the culprit arteries and dobutamine-induced wall motion abnormality territories. No complications occurred during examination or during the provocation test. All the patients were discharged with a calcium channel blocker and were doing well after 13 months of mean follow-up. CONCLUSION: Coronary artery spasm can be induced at DSE, but is a rare finding; it could, though, be clinically relevant as it may partly explain some erroneously labelled 'false-positive' examinations. Methylergometrine provocation test is a safe and advisable approach in such situations.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasoespasmo Coronario/etiología , Ecocardiografía de Estrés/efectos adversos , Agonistas Adrenérgicos beta/administración & dosificación , Anciano , Anciano de 80 o más Años , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Vasoespasmo Coronario/diagnóstico por imagen , Dobutamina/administración & dosificación , Ecocardiografía , Electrocardiografía , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Metilergonovina , Persona de Mediana Edad , Oxitócicos , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA