Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38970594

RESUMEN

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

2.
Cardiol Clin ; 42(3): 433-446, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38910026

RESUMEN

Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Imagen Multimodal , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/fisiopatología , Imagen Multimodal/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Miocardio/patología , Imagen por Resonancia Cinemagnética/métodos
3.
Artículo en Inglés | MEDLINE | ID: mdl-38841916

RESUMEN

BACKGROUND: Residual transprosthetic gradient (TG) after transcatheter aortic valve replacement (TAVR) with balloon-expandable valves (BEV) may be due to suboptimal valve expansion. AIMS: To compare hemodynamics after TAVR with small BEV according to postdilation strategy. METHODS: This observational, retrospective cohort study included 184 consecutive patients from a single center treated with 23 mm Sapien 3 Ultra (Edwards Lifesciences) BEV implantation in the aortic position and enrolled between January 2020 and April 2023. Patients treated with routine postdilation (RP, n = 73) were compared to patients treated according to local standard practice (SP, n = 111). Primary endpoint was 30-day mean TG. Secondary endpoints were incidence of 30-day prosthesis-patient mismatch (PPM), technical success and device success. RESULTS: Thirty-day mean TG was lower in RP versus SP (12.3 ± 4.6 mmHg vs. 14.1 ± 5.7 mmHg, p = 0.031), and incidence of PPM was less common with RP versus SP (47.3% vs. 71.0%, p = 0.006). Technical success (98.6% vs. 99.1%, p = 0.637) and device success (93.1% vs. 90.1%, p = 0.330) did not differ between groups. Differences in 30-day mean TG were driven by patients at normal flow (12.1 ± 4.0 mmHg vs. 15.0 ± 5.5 mmHg, p = 0.014), while no differences were evident among patients at low flow (12.5 ± 5.5 mmHg vs. 11.7 ± 5.5 mmHg, p = 0.644). RP decreased height and increased width of BEV, and a linear regression established that final BEV width could predict 30-day mean TG (r = -0.6654, p < 0.0001). CONCLUSIONS: RP after TAVR with small BEV was associated with more favorable forward-flow hemodynamics than SP.

4.
J Am Coll Cardiol ; 83(20): 2002-2014, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38749619

RESUMEN

Orthotopic transcatheter tricuspid valve replacement (TTVR) devices have been shown to be highly effective in reducing tricuspid regurgitation (TR), and interest in this therapy is growing with the recent commercial approval of the first orthotopic TTVR. Recent TTVR studies report preexisting cardiac implantable electronic device (CIED) transvalvular leads in ∼35% of patients, with entrapment during valve implantation. Concerns have been raised regarding the safety of entrapping leads and counterbalanced against the risks of transvenous lead extraction (TLE) when indicated. This Heart Valve Collaboratory consensus document attempts to define the patient population with CIED lead-associated or lead-induced TR, describe the risks of lead entrapment during TTVR, delineate the risks and benefits of TLE in this setting, and develop a management algorithm for patients considered for TTVR. An electrophysiologist experienced in CIED management should be part of the multidisciplinary heart team and involved in shared decision making.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/cirugía , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Índice de Severidad de la Enfermedad
5.
Circulation ; 149(22): e1223-e1238, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38660790

RESUMEN

Tricuspid valve disease is an often underrecognized clinical problem that is associated with significant morbidity and mortality. Unfortunately, patients will often present late in their disease course with severe right-sided heart failure, pulmonary hypertension, and life-limiting symptoms that have few durable treatment options. Traditionally, the only treatment for tricuspid valve disease has been medical therapy or surgery; however, there have been increasing interest and success with the use of transcatheter tricuspid valve therapies over the past several years to treat patients with previously limited therapeutic options. The tricuspid valve is complex anatomically, lying adjacent to important anatomic structures such as the right coronary artery and the atrioventricular node, and is the passageway for permanent pacemaker leads into the right ventricle. In addition, the mechanism of tricuspid pathology varies widely between patients, which can be due to primary, secondary, or a combination of causes, meaning that it is not possible for 1 type of device to be suitable for treatment of all cases of tricuspid valve disease. To best visualize the pathology, several modalities of advanced cardiac imaging are often required, including transthoracic echocardiography, transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance imaging, to best visualize the pathology. This detailed imaging provides important information for choosing the ideal transcatheter treatment options for patients with tricuspid valve disease, taking into account the need for the lifetime management of the patient. This review highlights the important background, anatomic considerations, therapeutic options, and future directions with regard to treatment of tricuspid valve disease.


Asunto(s)
American Heart Association , Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/patología , Estados Unidos , Enfermedades de las Válvulas Cardíacas/terapia , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/terapia , Implantación de Prótesis de Válvulas Cardíacas
7.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38099912

RESUMEN

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Valor Predictivo de las Pruebas , Recuperación de la Función , Índice de Severidad de la Enfermedad , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Resultado del Tratamiento , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Anciano , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Factores de Tiempo , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Estudios de Factibilidad , Medición de Riesgo , Diseño de Prótesis , Ecocardiografía Tridimensional
8.
Front Cardiovasc Med ; 10: 1180299, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38045907

RESUMEN

New generation 3-dimensional matrix array intracardiac echocardiography catheters have become commercially available recently, increasing image plane options compared to 2-dimensional and older generation 3-dimensional intracardiac echocardiography catheters. They are beginning to play an important role in structural heart interventions, especially for transcatheter tricuspid interventions, due to advantages in some situations that increase image quality over transesophageal echocardiography.

9.
Heart Fail Clin ; 19(4): 491-504, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37714589

RESUMEN

Current guidelines of aortic stenosis (AS) management focus on valve parameters, LV systolic dysfunction, and symptoms; however, emerging data suggest that there may be benefit of aortic valve replacement before it becomes severe by present criteria. Myocardial assessment using novel multimodality imaging techniques exhibits subclinical myocardial injury and remodeling at various stages before guideline-directed interventions, which predicts adverse outcomes. This raises the question of whether implementing serial myocardial assessment should become part of the standard appraisal, thereby identifying high-risk patients aiming to minimize adverse outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Imagen Multimodal , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Miocardio
10.
Int J Cardiol ; 390: 131139, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37355239

RESUMEN

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Persona de Mediana Edad , Volumen Sistólico , Función Ventricular Izquierda , Factores de Tiempo , Trasplante de Corazón/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Implantación de Prótesis de Válvulas Cardíacas/métodos
11.
JACC Case Rep ; 12: 101776, 2023 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-37091051

RESUMEN

Patients with tricuspid regurgitation are often referred late in their disease course and present with volume overload, which is a detrimental factor leading to right-sided chamber dilatation and dysfunction. Treatment of volume overload can 1) improve patient functional status; 2) avoid repeated invasive examinations; and 3) establish eligibility for transcatheter tricuspid intervention. (Level of Difficulty: Intermediate.).

12.
Artículo en Inglés | MEDLINE | ID: mdl-36948892

RESUMEN

BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.

13.
J Clin Med ; 12(1)2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36615141

RESUMEN

Transcatheter aortic valve implantation (TAVI) has risen over the past 20 years as a safe and effective alternative to surgical aortic valve replacement for treatment of severe aortic stenosis, and is now a well-established and recommended treatment option in suitable patients irrespective of predicted risk of mortality after surgery. Studies of numerous devices, either newly developed or reiterations of previous prostheses, have been accruing. We hereby review TAVI devices, with a focus on commercially available options, and aim to present a guide for prosthesis tailoring according to patient-related anatomical and clinical factors that may favor particular designs.

14.
Eur Heart J ; 44(10): 822-832, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36445158

RESUMEN

AIMS: The impact of sexuality in patients with significant tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve intervention (TTVI) is unknown. The aim of this study was to investigate sex-specific outcomes in patients with significant TR treated with TTVI vs. medical therapy alone. METHODS AND RESULTS: The Transcatheter Tricuspid Valve Therapies (TriValve) registry collected data on patients with significant TR from 24 centres who underwent TTVI from 2016 to 2021. A control cohort was formed by medically managed patients with ≥severe isolated TR diagnosed in 2015-18. The primary endpoint was freedom from all-cause mortality. Secondary endpoints were heart failure (HF) hospitalization, New York Heart Association (NYHA) functional status, and TR severity. One-year outcomes were assessed for the TriValve cohort and compared with the control cohort with the inverse probability of treatment weighting (IPTW). A total of 556 and 2072 patients were included from the TriValve and control groups, respectively. After TTVI, there was no difference between women and men in 1-year freedom from all-cause mortality 80.9% vs. 77.9%, P = 0.56, nor in HF hospitalization (P = 0.36), NYHA Functional Classes III and IV (P = 0.17), and TR severity >2+ at last follow-up (P = 0.42). Multivariable Cox-regression weighted by IPTW showed improved 1-year survival after TTVI compared with medical therapy alone in both women (adjusted hazard ratio 0.45, 95% confidence interval 0.23-0.83, P = 0.01) and men (adjusted hazard ratio 0.42, 95% confidence interval 0.18-0.89, P = 0.03). CONCLUSION: After TTVI in high-risk patients, there were no sex-related differences in terms of survival, HF hospitalization, functional status, and TR reduction up to 1 year. The IPTW analysis shows a survival benefit of TTVI over medical therapy alone in both women and men.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Masculino , Humanos , Femenino , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Sistema de Registros , Insuficiencia Cardíaca/complicaciones
16.
JACC Cardiovasc Interv ; 15(16): 1664-1674, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35981841

RESUMEN

BACKGROUND: The clinical course of patients with moderate aortic stenosis (AS) remains incompletely defined. OBJECTIVES: This study sought to analyze the clinical course of moderate AS and compare it with other stages of the disease. METHODS: Multiple electronic databases were searched to identify studies on adult moderate AS. Random-effects models were used to derive pooled estimates. The primary endpoint was all-cause death. The secondary endpoints were cardiac death, heart failure, sudden death, and aortic valve replacement. RESULTS: Among a total of 25 studies (12,143 moderate AS patients, 3.7 years of follow-up), pooled rates per 100 person-years were 9.0 (95% CI: 6.9 to 11.7) for all-cause death, 4.9 (95% CI: 3.1 to 7.5) for cardiac death, 3.9 (95% CI: 1.9 to 8.2) for heart failure, 1.1 (95% CI: 0.8 to 1.5) for sudden death, and 7.2 (95% CI: 4.3 to 12.2) for aortic valve replacement. Meta-regression analyses detected that diabetes (P = 0.019), coronary artery disease (P = 0.017), presence of symptoms (P < 0.001), and left ventricle (LV) dysfunction (P = 0.009) were associated with a significant impact on the overall estimate of all-cause death. All-cause mortality was higher in patients with reduced LV ejection fraction (<50%) than with normal LV ejection fraction: 16.5 (95% CI: 5.2 to 52.3) and 4.2 (95% CI: 1.4 to 12.8) per 100 person-years, respectively. Compared with moderate AS, the incidence rate difference of all-cause mortality was -3.9 (95% CI: -6.7 to -1.1) for no or mild AS and +2.2 (95% CI: +0.8 to +3.5) for severe AS patients. CONCLUSIONS: Moderate AS appears to be associated with a mortality risk higher than no or mild AS but lower than severe AS, which increases in specific population subsets. The impact of early intervention in moderate AS patients having high-risk features deserves further investigation.


Asunto(s)
Estenosis de la Válvula Aórtica , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Muerte , Muerte Súbita , Insuficiencia Cardíaca , Humanos , Reemplazo de la Válvula Aórtica Transcatéter , Resultado del Tratamiento
17.
Int J Cardiol ; 364: 35-37, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35662560

RESUMEN

INTRODUCTION: Despite the technological advances and increasing operator experience, the rate of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) has not decreased over time. With a continuous downward trend in post-TAVR length of stay, prolonged home-monitoring may have a key role in detecting potentially serious conduction abnormalities after TAVR discharge. METHODS: In this study, the ZioPatch-AT monitor was used to detect conduction abnormalities after TAVR discharge. The cardiac monitoring device was systematically provided to all patients having pre-existing right bundle branch block or developing intra-/peri-procedural conduction disturbances, in the absence of guideline indication for PPI at discharge. RESULTS: From a total of 75 patients at high-risk of conduction disturbances, 8 (11%) of them underwent PPI and most of them (6/8) were detected before symptoms' occurrence. Paired analysis between baseline and discharge electrocardiograms detected a significant widening of the QRS in all patients; on the contrary, PR length was significantly increased only in the group experiencing HAVB after discharge (p < 0.01). CONCLUSIONS: In an early post-TAVR discharge era, 30-day outpatient cardiac rhythm monitoring is potentially a safe solution to allow timely recognition of new conduction disturbances requiring PPI.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Trastorno del Sistema de Conducción Cardíaco/etiología , Trastorno del Sistema de Conducción Cardíaco/terapia , Estimulación Cardíaca Artificial , Estudios de Factibilidad , Humanos , Marcapaso Artificial/efectos adversos , Alta del Paciente , Factores de Riesgo , Telemetría , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
J Am Coll Cardiol ; 79(5): 448-461, 2022 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-35115101

RESUMEN

BACKGROUND: The right ventricular (RV)-pulmonary arterial (PA) coupling ratio relates the efficiency with which RV stroke work is transferred into the PA. Lower ratios indicate an inadequate RV contractile response to increased afterload. OBJECTIVES: This study sought to evaluate the prognostic significance of RV-PA coupling in patients with tricuspid regurgitation (TR) who were undergoing transcatheter tricuspid valve repair or replacement (TTVR). METHODS: The study investigators calculated RV-PA coupling ratios for patients enrolled in the global TriValve registry by dividing the tricuspid annular plane systolic excursion (TAPSE) by the PA systolic pressure (PASP) from transthoracic echocardiograms performed before the procedure and 30 days after the procedure. The primary endpoint was all-cause mortality at 1-year follow-up. RESULTS: Among 444 patients analyzed, their mean age was 76.9 ± 9.1 years, and 53.8% of the patients were female. The median TAPSE/PASP ratio was 0.406 mm/mm Hg (interquartile range: 0.308-0.567 mm/mm Hg). Sixty-three patients died within 1 year of TTVR, 21 with a TAPSE/PASP ratio >0.406 and 42 with a TAPSE/PASP ratio ≤0.406. In multivariable Cox regression analysis, a TAPSE/PASP ratio >0.406 vs ≤0.406 was associated with a decreased risk of all-cause mortality (HR: 0.57; 95% CI: 0.35-0.93; P = 0.023). In 234 (52.7%) patients with echocardiograms 30 days after TTVR, a decline in RV-PA coupling was independently associated with reduced odds of all-cause mortality (odds ratio [OR]: 0.42; 95% CI: 0.19-0.93; P = 0.032). The magnitude of TR reduction after TTVR (≥1+ vs <1+; OR: 2.53; 95% CI: 1.06-6.03; P = 0.037) was independently associated with a reduction in post-TTVR RV-PA coupling. CONCLUSIONS: RV-PA coupling is a powerful, independent predictor of all-cause mortality in patients with TR undergoing TTVR. These data suggest that the TAPSE/PASP ratio can inform patient selection and prognostication following TTVR.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Arteria Pulmonar/fisiopatología , Presión Esfenoidal Pulmonar/fisiología , Volumen Sistólico/fisiología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Función Ventricular Derecha/fisiología , Anciano , Ecocardiografía Doppler , Femenino , Estudios de Seguimiento , Humanos , Masculino , Periodo Posoperatorio , Sistema de Registros , Estudios Retrospectivos , Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología , Función Ventricular Izquierda
19.
Interv Cardiol Clin ; 11(1): 67-80, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34838298

RESUMEN

The tricuspid valve often is referred to as "the forgotten valve" because it frequently is managed conservatively due to poor prognostic outcomes with conventional surgical intervention, in particular, in high-risk patients. Nevertheless, a paradigm shift has occurred in recent years, due to a growing evidence base supporting the independent prognostic influence of severe tricuspid regurgitation (TR) on patient outcomes. Both transcatheter valve replacement and valve repair have emerged as feasible and efficacious interventions for TR correction. Novel transcatheter repair techniques that replicate surgical annuloplasty are evolving as potentially lower-risk alternatives.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Cateterismo Cardíaco , Humanos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA