Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 185
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
2.
EuroIntervention ; 20(16): 1029-1038, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39155753

RESUMEN

BACKGROUND: Limited data are available on transcatheter patent foramen ovale (PFO) closure outcomes in the elderly. AIMS: Through this study, we aimed to determine the incidence and predictors of adverse events (recurrent cerebrovascular events [CVE] and atrial fibrillation [AF]) post-PFO closure in older patients with cryptogenic events. METHODS: This multicentre international study included patients over 60 years undergoing PFO closure for cryptogenic thromboembolic events. A dedicated database compiled baseline, procedural, and follow-up data. Competing risk and adjusted outcome predictor analyses were conducted. RESULTS: A total of 689 patients were included (median age 65 years, 41.2% female, mean Risk of Paradoxical Embolism [RoPE] score 4.5). The procedural success rate was 99.4%. After a median follow-up of 2 (interquartile range 1-5) years, 66 patients (9.6%) had died. CVE and stroke rates were 1.21 and 0.55 per 100 patient-years, respectively. Diabetes (hazard ratio [HR] 3.89, 95% confidence interval [CI]: 1.67-9.07; p=0.002) and atrial septal aneurysm (ASA; HR 5.25, 95% CI: 1.56-17.62; p=0.007) increased the CVE risk. New-onset AF occurred at a rate of 3.30 per 100 patient-years, with 51.3% within one month post-procedure. Older age (HR 1.05 per year, 95% CI: 1.00-1.09; p=0.023) and the absence of hypertension (HR 2.04, 95% CI: 1.19-3.57; p=0.010) were associated with an increased risk of AF. CONCLUSIONS: Older patients undergoing PFO closure had a relatively low rate of CVE and new-onset AF after a median follow-up of 2 years. The presence of diabetes, ASA, and a more advanced age determined an increased risk of adverse clinical events. These factors may be considered in the clinical decision-making process regarding PFO closure in this challenging population.


Asunto(s)
Fibrilación Atrial , Cateterismo Cardíaco , Foramen Oval Permeable , Humanos , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/cirugía , Femenino , Masculino , Anciano , Persona de Mediana Edad , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Fibrilación Atrial/complicaciones , Fibrilación Atrial/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/prevención & control , Embolia Paradójica/etiología , Embolia Paradójica/epidemiología , Embolia Paradójica/prevención & control , Dispositivo Oclusor Septal/efectos adversos , Anciano de 80 o más Años , Factores de Edad , Incidencia
3.
Am Heart J ; 277: 76-92, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-39134216

RESUMEN

The foramen ovale plays a vital role in sustaining life in-utero; however, a patent foramen ovale (PFO) after birth has been associated with pathologic sequelae in the systemic circulation including stroke/transient ischemic attack (TIA), migraine, high altitude pulmonary edema, decompression illness, platypnea-orthodeoxia syndrome (POS) and worsened severity of obstructive sleep apnea. Importantly, each of these conditions is most commonly observed among specific age groups: migraine in the 20 to 40s, stroke/TIA in the 30-50s and POS in patients >50 years of age. The common and central pathophysiologic mechanism in each of these conditions is PFO-mediated shunting of blood and its contents from the right to the left atrium. PFO-associated pathologies can therefore be divided into (1) paradoxical systemic embolization and (2) right to left shunting (RLS) of blood through the PFO. Missing in the extensive literature on these clinical syndromes are mechanistic explanations for the occurrence of RLS, including timing and the volume of blood shunted, the impact of age on RLS, and the specific anatomical pathway that blood takes from the venous system to the left atrium. Visualization of the flow pattern graphically illustrates the underlying RLS and provides a greater understanding of the critical flow dynamics that determine the frequency, volume, and pathway of flow. In the present review, we describe the important role of foramen ovale in in-utero physiology, flow visualization in patients with PFO, as well as contributing factors that work in concert with PFO to result in the diverse pathophysiological sequelae.


Asunto(s)
Foramen Oval Permeable , Humanos , Foramen Oval Permeable/fisiopatología , Foramen Oval Permeable/complicaciones , Trastornos Migrañosos/fisiopatología , Trastornos Migrañosos/etiología , Ataque Isquémico Transitorio/fisiopatología , Ataque Isquémico Transitorio/etiología , Apnea Obstructiva del Sueño/fisiopatología , Apnea Obstructiva del Sueño/complicaciones , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología , Enfermedad de Descompresión/fisiopatología , Enfermedad de Descompresión/complicaciones , Edema Pulmonar/etiología , Edema Pulmonar/fisiopatología , Embolia Paradójica/fisiopatología , Embolia Paradójica/etiología
4.
JACC Cardiovasc Interv ; 17(9): 1079-1090, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38749587

RESUMEN

Tetralogy of Fallot (TOF) is the most common form of cyanotic congenital heart disease. Palliative procedures, either surgical or transcatheter, aim to improve oxygen saturation, affording definitive procedures at a later stage. Transcatheter interventions have been used before and after surgical palliative or definitive repair in children and adults. This review aims to provide an overview of the different catheter-based interventions for TOF across all age groups, with an emphasis on palliative interventions, such as patent arterial duct stenting, right ventricular outflow tract stenting, or balloon pulmonary valvuloplasty in infants and children and transcatheter pulmonary valve replacement in adults with repaired TOF, including the available options for a large, dilated native right ventricular outflow tract.


Asunto(s)
Valvuloplastia con Balón , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Cuidados Paliativos , Stents , Tetralogía de Fallot , Humanos , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/efectos adversos , Lactante , Resultado del Tratamiento , Factores de Edad , Preescolar , Niño , Adulto , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Adolescente , Recién Nacido , Adulto Joven , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Factores de Riesgo , Femenino , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Válvula Pulmonar/fisiopatología , Masculino , Hemodinámica , Persona de Mediana Edad , Recuperación de la Función
5.
J Thorac Dis ; 16(3): 1836-1842, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38617787

RESUMEN

Background: Transcatheter aortic valve implantation (TAVI) has become a viable alternative to palliation in patients with severe aortic stenosis. We compared general anesthesia to conscious sedation for TAVI procedures with respect to post operative morbidity, hospital length of stay, and financial burden. Methods: We conducted a retrospective review of prospectively collected data in patients undergoing transfemoral TAVI procedures from 2012 to 2017. Patients were matched based on age and sex and classed into either general anesthesia or conscious sedation groups respectively. Conscious sedation was provided with a dexmedetomidine infusion, and patients in general anesthesia group received a standard induction, tracheal intubation, and maintenance with sevoflurane. The hospital case costs were compared between the two groups before and after adjustment for inflation. Results: We matched 124 pairs for a total of 248 patients. Both groups were similar with respect to demographic data, past medical history, medications, and intraoperative characteristics. There was no difference in postoperative morbidity and mortality between the two groups. The median hospital length of stay was 5 [interquartile range (IQR): 3, 10] and 7 (IQR: 4, 12) days, P=0.01, and after adjustment for inflation, the total hospital case costs were $48,984 (IQR: $44,802, $61,438) Canadian (CAD) vs. $55,333 (IQR: $46,832, $68,702) CAD, P=0.01, in the conscious sedation and general anesthesia groups, respectively. Conclusions: Advancements in TAVI technologies, conscious sedation and a collaborative, multidisciplinary team approach reduces overall length of hospital stay and procedure costs.

7.
J Invasive Cardiol ; 36(1)2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38224293

RESUMEN

Congenital tricuspid valve stenosis is extremely rare. We describe 2 cases of patients with adult congenital heart disease with hypoplastic tricuspid valve annulus who were symptomatic from annular- and leaflet-level tricuspid stenosis. The patients underwent transcatheter balloon valvuloplasty with good clinical outcomes. An extensive literature review and analysis of various procedural strategies suggests that percutaneous balloon valvuloplasty may be a reasonable therapeutic choice as a first-line therapy or when open surgical repair is associated with prohibitively high mortality. This procedure can be performed either as a destination therapy or as a bridge to valve replacement.


Asunto(s)
Valvuloplastia con Balón , Cardiopatías Congénitas , Estenosis de la Válvula Tricúspide , Adulto , Humanos , Constricción Patológica , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Estenosis de la Válvula Tricúspide/diagnóstico , Estenosis de la Válvula Tricúspide/cirugía
8.
Clin Res Cardiol ; 113(10): 1485-1500, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38112741

RESUMEN

BACKGROUND: Chronic kidney disease (CKD) is a risk factor for embolic stroke, and many nonvalvular atrial fibrillation (NVAF) patients have concomitant CKD. Anticoagulation therapy can be challenging in CKD due to increased bleeding risk, and left atrial appendage occlusion (LAAO) may be a promising alternative. OBJECTIVE: This systematic review aimed to consolidate current evidence on the safety and effectiveness of transcatheter LAAO in patients with CKD and end-stage renal disease (ESRD). METHODS: Medline, Cochrane, and Embase databases were searched from inception to September 2, 2022. We conducted a meta-analysis if an outcome was evaluated in at least two similar studies. RESULTS: We included 15 studies with 77,780 total patients. Of the 15 studies, 11 had a cohort design (five prospective and six retrospective), and four were case series. Patients with CKD were older and had a higher prevalence of comorbidities than non-CKD patients. The two groups did not differ in procedural failure rate, vascular complications, or pericardial tamponade. CKD patients exhibited higher odds of in-hospital acute kidney injury (AKI) and bleeding, longer-term bleeding, and mortality than those without CKD. The risk of in-hospital and longer-term cardioembolic events was similar between CKD and non-CKD populations (odds ratio = 1.01 [95% CI 0.70-1.15] and 1.05 [95% CI 0.55-2.00], respectively). Patients with ESRD had higher odds of in-hospital mortality and cardioembolic events than non-ESRD patients, with no differences in risk of pericardial tamponade. CONCLUSIONS: Based on observational studies, LAAO may be an effective option to prevent cardioembolic events in CKD. However, CKD patients may have higher odds of AKI and in-hospital and long-term bleeding and mortality. The adverse clinical outcomes observed in CKD patients may be attributed to this population's high burden of comorbidities, especially among those with ERSD, rather than the LAAO procedure itself. To ensure maximum clinical benefit, careful patient selection, management, and surveillance involving multidisciplinary teams are essential for CKD patients undergoing LAAO.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cateterismo Cardíaco , Insuficiencia Renal Crónica , Humanos , Apéndice Atrial/cirugía , Insuficiencia Renal Crónica/complicaciones , Fibrilación Atrial/complicaciones , Cateterismo Cardíaco/métodos , Factores de Riesgo
9.
J Invasive Cardiol ; 35(9)2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37983109

RESUMEN

OBJECTIVE: Outcomes after adult coarctation of the aorta (CoA) stenting is scant. We explored predictors of aortic remodeling after stent implantation and report early- and intermediate-term clinical outcomes. METHODS: Adult patients who underwent stenting between July 2003 and December 2017 were included in this single-center retrospective study. We created a novel index of aortic volumetric and diameter changes using computed tomography (CT)/magnetic resonance (MR) images measured through TeraRecon and AngioQ. Predictors of aortic remodeling were explored using univariable linear regression analysis. RESULTS: One hundred and thirty-four patients (mean age 35.2 years, 58.2% men) underwent CoA stenting. Paired aortic diameter measurements were available in 20 patients, and 40 paired patients in volumetric measurements. There was significant reduction in aortic diameter immediately proximal to the left carotid and subclavian arteries, and the aorta distal to the stenosis (P less than .05) at follow-up. There was a significant volumetric reduction in the ascending aorta, aortic arch, and the aortic segment most proximal to the top of the stent (P less than .05). Univariate predictors of aortic remodeling included sex, age, presence of previous surgical repair, aortic valve morphology, and the number of antihypertensive medications. Mean follow-up time was 4.0 ± 3.8 years, where 5% of patients underwent reintervention due to complications, 3% developed aneurysms, and 3% had stent fractures. CONCLUSIONS: This study is the first to examine the anatomical changes that occur in the aorta post stent repair through analysis of serial imaging. Patients with stent-repaired coarctation demonstrated negative remodeling in multiple areas of the aorta with regards to the aortic diameter and volumetric measurements.


Asunto(s)
Coartación Aórtica , Adulto , Masculino , Humanos , Femenino , Coartación Aórtica/diagnóstico , Coartación Aórtica/cirugía , Estudios Retrospectivos , Aorta , Antihipertensivos , Constricción Patológica
10.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37968032

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Asunto(s)
Fibrilación Atrial , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Constricción Patológica/etiología , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Hemodinámica , Sistema de Registros , Diseño de Prótesis
11.
J Cardiovasc Comput Tomogr ; 17(6): 373-383, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37635033

RESUMEN

Different methodologies have been used to assess the role of AV calcification (AVC) on TAVI outcomes. This systematic review aims to describe the burden of AVC, synthesize the different methods of calcium score quantification, and evaluate the impact of AVC on outcomes after TAVI. We included studies of TAVI patients who had reported AV calcium scoring by contrast-enhanced multidetector CT and the Agatston method. The impact of calcification on TAVI outcomes without restrictions on follow-up time or outcome type was evaluated. Results were reported descriptively, and a meta-analysis was conducted when feasible. Sixty-eight articles were included, with sample sizes ranging from 23 to 1425 patients. Contrast-enhanced calcium scoring was reported in 30 studies, calcium volume score in 28 studies, and unique scoring methods in two. All studies with calcium volume scores had variable protocols, but most utilized a modified Agatston method with variable attenuation threshold values of 300-850 HU. Eight studies used the Agatston method, with the overall mean AV calcium score in studies published from 2010 to 2012 of 3342.9 AU [95%CI: 3150.4; 3535.4, I2 â€‹= â€‹0%]. The overall mean score was lower and heterogenous in studies published from 2014 to 2020 (2658.9 AU [95% CI: 2517.3; 2800.5, I2 â€‹= â€‹79%]. Most studies reported a positive association between calcium burden and increased risk of adverse outcomes, including implantation of permanent pacemaker (7/8 studies), paravalvular leak (13/13 studies), and risk of aortic rupture (2/2 studies). AVC quantification methodology with contrast-enhanced CT is still variable. AVC negatively impacts TAVI outcomes independently of the quantification method.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Calcio , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Valor Predictivo de las Pruebas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Tomografía Computarizada Multidetector , Calcinosis/cirugía , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Resultado del Tratamiento
13.
Am J Cardiol ; 201: 232-238, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37392606

RESUMEN

The natural history of an unrepaired isolated partial anomalous pulmonary venous connection(s) (PAPVC) and the absence of other congenital anomalies remains unclear. This study aimed to expand the understanding of the clinical outcomes in this population. Isolated PAPVC with an intact atrial septum is a relatively uncommon condition. There is the perception that patients with isolated PAPVC are usually asymptomatic, that the lesion generally has a limited hemodynamic impact, and that surgical repair is rarely justified. For this retrospective study, we reviewed our institutional database to identify patients with either 1 or 2 anomalous pulmonary veins that drain a portion of but not the complete ipsilateral lung. Patients with previous surgical cardiac repair, coexistence of other congenital cardiac anomalies that would result in either pretricuspid or post-tricuspid loading of the right ventricle (RV), or scimitar syndrome were excluded. We reviewed their clinical course over the follow-up period. We identified 53 patients; 41 with a single and 12 with 2 anomalous PAPVC. A total of 30 patients (57%) were men, with a mean age at the latest clinic visit of 47 ± 19 years (18 to 84 years). Turner syndrome (6 of 53, 11.3%), bicuspid aortic valve (6 of 53, 11.3%), and coarctation of the aorta (5 of 53, 9.4%) were commonly associated anomalies. A single anomalous left upper lobe vein was the most commonly identified variation. More than half of the patients were asymptomatic. Cardiopulmonary exercise test demonstrated a maximal oxygen consumption of 73 ± 20% expected (36 to 120). Transthoracic echocardiography demonstrated a mean RV basal diameter of 4.4 ± 0.8 cm, RV systolic pressure of 38 ± 13 (16 to 84) mm Hg. A total of 8 patients (14.8%) had ≥moderate tricuspid regurgitation. Cardiac magnetic resonance in 42 patients demonstrated a mean RV end-diastolic volume index of 122 ±3 0 ml/m2 (66 to 188 ml/m2), of which in 8 (14.8%), it was >150 ml/m2. Magnetic resonance imaging-based Qp:Qs was 1.6 ± 0.3. A total of 5 patients (9.3%) had established pulmonary hypertension (mean pulmonary artery pressure ≥25 mm Hg). In conclusion, isolated single or dual anomalous pulmonary venous connection is not necessarily a benign congenital anomaly because a proportion of patients develop pulmonary hypertension and/or RV dilation. Regular follow-up and on-going patient surveillance with cardiac imaging is advised.


Asunto(s)
Tabique Interatrial , Cardiopatías Congénitas , Hipertensión Pulmonar , Venas Pulmonares , Síndrome de Cimitarra , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Síndrome de Cimitarra/diagnóstico por imagen , Síndrome de Cimitarra/cirugía , Hipertensión Pulmonar/etiología , Estudios Retrospectivos , Corazón , Cardiopatías Congénitas/complicaciones , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía
14.
JACC Cardiovasc Interv ; 16(11): 1360-1366, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37316146

RESUMEN

BACKGROUND: Patients with thrombophilia are underrepresented in studies evaluating outcomes after closure of patent foramen ovale (PFO). Real-world data on long term outcomes in this population are very limited. OBJECTIVES: This study compared outcomes in patients with and without thrombophilia undergoing PFO closure, using data from a large, clinical database linked to population-based databases. METHODS: This retrospective cohort study included consecutive patients who had a transcatheter PFO closure and had preprocedural thrombophilia screening. Data from a retrospective, clinical registry were linked to population-based administrative databases in Ontario Canada to evaluate outcomes. Outcomes were reported as rates per 100 person-years and compared using Poisson regression. RESULTS: We included 669 patients, with a mean age of 56.4 years, 97.9% of whom underwent PFO closure for a cryptogenic stroke. Thrombophilia was diagnosed among 174 (26.0%), of which 86% had inherited mutations. In-hospital, procedural complications were observed in 3.1% of patients with no difference by thrombophilia status. Similarly, no differences were observed in 30-day emergency department visits and readmissions. Over the median follow-up of 11.6 years, the most common adverse outcome was new-onset atrial fibrillation (1.0 per 100 person-years; 95% CI: 0.8-1.2), followed by recurrent cerebrovascular events (0.8 per 100 person-years; 95% CI: 0.6-1.1) with no differences between the groups (P > 0.05). CONCLUSIONS: After PFO closure, no differences were observed in long-term adverse outcomes between patients with and without thrombophilia. Though these patients have been excluded from randomized clinical trials of PFO closure in the past, real-world evidence supports their eligibility for the procedure.


Asunto(s)
Foramen Oval Permeable , Trombofilia , Humanos , Persona de Mediana Edad , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico por imagen , Foramen Oval Permeable/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Ontario , Trombofilia/complicaciones , Trombofilia/diagnóstico
15.
EuroIntervention ; 19(5): e442-e449, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37128805

RESUMEN

BACKGROUND: Data regarding the safety and long-term effectiveness of percutaneous closure of paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) are scarce. AIMS: This study aims to present a large multicentre international experience of percutaneous post-TAVI PVL closure. METHODS: All patients who underwent percutaneous post-TAVI PVL closure in 14 hospitals across Europe and North America between January 2018 and October 2022 were included. RESULTS: Overall, 45 patients (64% male) were enrolled. The median age was 80 years (75-84). Among them, 67% and 33% had self-expanding and balloon-expandable valve implantations, respectively. Baseline post-TAVI PVL was severe in 67% of cases and moderate in the rest. The time from index TAVI to PVL closure procedure was 16.1 (8.7-34.8) months. Most patients were in NYHA Class III and IV (73%) before the procedure, and 40% had referred hospitalisations for heart failure between TAVI and the PVL closure procedure. Successful PVL closure was achieved in 94%, reducing regurgitation to ≤mild in 91% and moderate in the rest. The Amplatzer Valvular Plug III was the most frequently used device (27 cases), followed by the Amplatzer Valvular Plug 4. The incidence of severe adverse events was 11%. None of the patients died during the index hospitalisation. During long-term follow-up (21.7±16.2 months), the all-cause mortality rate was 14%, and patients presented improvement in functional status and a significant reduction in the rate of hospitalisation for heart failure (from 40% to 6%). CONCLUSIONS: Percutaneous PVL closure is a feasible and safe option for treating post-TAVI leaks. Successful PVL reduction to mild or less could be associated with acute and long-lasting improvements in clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Sistema de Registros , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
18.
Int J Cardiol ; 371: 109-115, 2023 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-36165815

RESUMEN

BACKGROUND: Patent foramen ovale (PFO) is a congenital heart defect associated with an increased risk of cryptogenic stroke. We aimed to evaluate real-world outcomes of adult patients undergoing transcatheter PFO closure with the Amplatzer PFO Occluder. METHODS: In this single centre, retrospective cohort study, we linked a detailed clinical registry with provincial administrative databases to obtain short and long-term outcomes. Validated algorithms were used to established baseline comorbidities and adverse outcomes. RESULTS: Between 1999 and 2017, 479 patients had PFO closure with an Amplatzer PFO Occluder. The average age of the patients was 47.3 years (standard deviation (SD) = 12.4), and 54.7% were males. The procedural success was 100%, and 96% of patients were discharged on the same day. Any in-hospital complication was observed in 2.5% (n = 12) of patients. At 30 days post-discharge, 18% of patients had an ED visit and 5% a hospitalization. Over a mean follow-up of 9.1 (SD = 3.8) years, 4% experienced TIA, 1.5% stroke, and 7.6% atrial fibrillation. The composite outcome of stroke/TIA/death was observed in 10.9% of patients (1.22 events per 100 person-years). Patients >60 years old experienced higher rates of adverse events than younger patients. CONCLUSIONS: In this large real-world cohort of patients with cryptogenic stroke, we observed excellent safety and effectiveness outcomes for PFO closure conducted with Amplatzer PFO Occluder, similar to randomized controlled trials or other long-term cohort studies. New onset atrial fibrillation was one of the most commonly adverse events. Future studies should investigate early post-discharge management of patients to prevent readmissions.


Asunto(s)
Fibrilación Atrial , Foramen Oval Permeable , Accidente Cerebrovascular Isquémico , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Adulto , Masculino , Humanos , Persona de Mediana Edad , Femenino , Estudios Retrospectivos , Fibrilación Atrial/complicaciones , Cuidados Posteriores , Cateterismo Cardíaco/efectos adversos , Alta del Paciente , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/complicaciones , Dispositivo Oclusor Septal/efectos adversos , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular Isquémico/complicaciones , Resultado del Tratamiento
19.
JACC Adv ; 2(2): 100257, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938308

RESUMEN

Background: The risk of erosion of an atrial septal closure device, in particular the Amplatzer Septal Occluder, has been described as higher in patients with a short aortic rim. Similar concern has been applied to patent foramen ovale (PFO) closure devices, but there are only rare reported cases of erosion. It may be that smaller devices are chosen due to fear of device erosion in PFO patients when this is not necessarily an issue. Objectives: The authors aimed to assess outcomes after PFO closure with the Amplatzer PFO device in patients with a short (<9 mm) aortic rim. Methods: We performed a retrospective analysis of PFO closure for any indication, between 2006 and 2017 at a quaternary center. Preprocedural transesophageal echocardiographic parameters including the aortic rim were remeasured. Long-term outcomes were obtained by linkage to provincial administrative databases. Results: Over the study period, 324 patients underwent PFO closure with the Amplatzer PFO device, with a mean age of 49.8 years; 61% had a short aortic rim (<9 mm). The most common indication was cryptogenic stroke (72%); those with longer aortic distance were more likely to have a non-stroke indication for closure, diabetes (15% vs 6.5%, P = 0.04), and heart failure (15.7% vs 4%, P < 0.001). Over a median 7 years of follow-up, there were no cases of device erosion or embolization requiring cardiac surgery. Conclusions: In a large cohort with long-term administrative follow-up (1,394 patient-years), implantation of an Amplatzer PFO device was performed safely even in patients with a short aortic rim.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA