Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 317
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
2.
Nat Commun ; 15(1): 8256, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39313509

RESUMEN

H2O transforms to two forms of superionic (SI) ice at high pressures and temperatures, which contain highly mobile protons within a solid oxygen sublattice. Yet the stability field of both phases remains debated. Here, we present the results of an ultrafast X-ray heating study utilizing MHz pulse trains produced by the European X-ray Free Electron Laser to create high temperature states of H2O, which were probed using X-ray diffraction during dynamic cooling. We confirm an isostructural transition during heating in the 26-69 GPa range, consistent with the formation of SI-bcc. In contrast to prior work, SI-fcc was observed exclusively above ~50 GPa, despite evidence of melting at lower pressures. The absence of SI-fcc in lower pressure runs is attributed to short heating timescales and the pressure-temperature path induced by the pump-probe heating scheme in which H2O was heated above its melting temperature before the observation of quenched crystalline states, based on the earlier theoretical prediction that SI-bcc nucleates more readily from the fluid than SI-fcc. Our results may have implications for the stability of SI phases in ice-rich planets, for example during dynamic freezing, where the preferential crystallization of SI-bcc may result in distinct physical properties across mantle ice layers.

4.
Braz J Med Biol Res ; 56: e12408, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36790289

RESUMEN

Globally, cardiac arrest (CA) is a leading cause of death and disability. Asphyxial CA (ACA)-induced kidney damage is a crucial factor in reducing the survival rate. The purpose of this study was to investigate the role of antioxidant enzymes in histopathological renal damage in an ACA rat model at different time points. A total of 88 rats were divided into five groups and exposed to ACA except for the sham group. To evaluate glomerular function and oxidative stress, serum levels of blood urea nitrogen (BUN) and creatinine (Crtn) and malondialdehyde (MDA) levels in renal tissues were measured. To determine histopathological damage, hematoxylin and eosin staining, periodic acid-Schiff staining, and Masson's trichrome staining were performed. Expression levels of antioxidant enzymes including superoxide dismutase-1 (SOD-1), superoxide dismutase-2 (SOD-2), catalase (CAT), and glutathione peroxidase (GPx) were measured by immunohistochemistry (IHC). Survival rate of the experimental rats was reduced to 80% at 6 h, 55% at 12 h, 42.9% at 1 day, and 33% at 2 days after return of spontaneous circulation. Levels of BUN, Crtn, and MDA started to increase significantly in the early period of CA induction. Renal histopathological damage increased markedly from 6 h until two days post-CA. Additionally, expression levels of antioxidant enzymes were significantly decreased at 6 h, 12 h, 1 day, and 2 days after CA. CA-induced oxidative stress and decreased levels of antioxidant enzymes (SOD-1, SOD-2, CAT, GPx) from 6 h to two days could be possible mediators of severe renal tissue damage and increased mortality rate.


Asunto(s)
Antioxidantes , Enfermedades Renales , Ratas , Animales , Antioxidantes/farmacología , Riñón/patología , Catalasa , Estrés Oxidativo , Enfermedades Renales/patología , Superóxido Dismutasa , Glutatión Peroxidasa/metabolismo , Malondialdehído/metabolismo
5.
Braz. j. med. biol. res ; 56: e12408, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1420768

RESUMEN

Globally, cardiac arrest (CA) is a leading cause of death and disability. Asphyxial CA (ACA)-induced kidney damage is a crucial factor in reducing the survival rate. The purpose of this study was to investigate the role of antioxidant enzymes in histopathological renal damage in an ACA rat model at different time points. A total of 88 rats were divided into five groups and exposed to ACA except for the sham group. To evaluate glomerular function and oxidative stress, serum levels of blood urea nitrogen (BUN) and creatinine (Crtn) and malondialdehyde (MDA) levels in renal tissues were measured. To determine histopathological damage, hematoxylin and eosin staining, periodic acid-Schiff staining, and Masson's trichrome staining were performed. Expression levels of antioxidant enzymes including superoxide dismutase-1 (SOD-1), superoxide dismutase-2 (SOD-2), catalase (CAT), and glutathione peroxidase (GPx) were measured by immunohistochemistry (IHC). Survival rate of the experimental rats was reduced to 80% at 6 h, 55% at 12 h, 42.9% at 1 day, and 33% at 2 days after return of spontaneous circulation. Levels of BUN, Crtn, and MDA started to increase significantly in the early period of CA induction. Renal histopathological damage increased markedly from 6 h until two days post-CA. Additionally, expression levels of antioxidant enzymes were significantly decreased at 6 h, 12 h, 1 day, and 2 days after CA. CA-induced oxidative stress and decreased levels of antioxidant enzymes (SOD-1, SOD-2, CAT, GPx) from 6 h to two days could be possible mediators of severe renal tissue damage and increased mortality rate.

6.
Appl Radiat Isot ; 179: 110022, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34781075

RESUMEN

The 129I standardization, using the movable 4πß(LS)-X(NaI(Tl)) coincidence system, was performed for two 129I radioactive sources - one was dissolved in 0.1M NaOH solution and the other in 0.1M HNO3 solution. The system incorporates three movable PM tubes for a ß-counter placed on a plane and a X-ray detector that can be moved up to the bottom of the vial. The ß-efficiency depending on the amount of radioactive solution was investigated with 14 liquid scintillation samples prepared by gravimetrically dispensing 4.4-145 mg of 129I radioactive solution. The ß-efficiencies above 90% were observed at less than 56 mg, but it was at most 70% at 145 mg. This occurred regardless of the activity of the sample or the type of chemical solution used to dissolve 129I source. The activity concentration of each 129I source was determined by efficiency-extrapolation method for samples with an activity range of 0.28-4.5 kBq. The ß-efficiency points were derived over 10 intervals by moving 3-PM tubes in fine steps of about 1 mm from the sample. The highest value for ß-efficiency was 95%. The combined uncertainty were 0.25% and 0.26%, respectively. The stated precision obtained using the system is better than that previously reported in the literature obtained by the triple to double coincidence ratio (TDCR) or the CIEMAT/NIST efficiency tracing method.

7.
Science ; 373(6551): 213-216, 2021 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-34244413

RESUMEN

The discovery of superconductivity in infinite-layer nickelates brings us tantalizingly close to a material class that mirrors the cuprate superconductors. We measured the magnetic excitations in these nickelates using resonant inelastic x-ray scattering at the Ni L 3-edge. Undoped NdNiO2 possesses a branch of dispersive excitations with a bandwidth of approximately 200 milli-electron volts, which is reminiscent of the spin wave of strongly coupled, antiferromagnetically aligned spins on a square lattice. The substantial damping of these modes indicates the importance of coupling to rare-earth itinerant electrons. Upon doping, the spectral weight and energy decrease slightly, whereas the modes become overdamped. Our results highlight the role of Mottness in infinite-layer nickelates.

8.
J Synchrotron Radiat ; 28(Pt 3): 688-706, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33949979

RESUMEN

The high-precision X-ray diffraction setup for work with diamond anvil cells (DACs) in interaction chamber 2 (IC2) of the High Energy Density instrument of the European X-ray Free-Electron Laser is described. This includes beamline optics, sample positioning and detector systems located in the multipurpose vacuum chamber. Concepts for pump-probe X-ray diffraction experiments in the DAC are described and their implementation demonstrated during the First User Community Assisted Commissioning experiment. X-ray heating and diffraction of Bi under pressure, obtained using 20 fs X-ray pulses at 17.8 keV and 2.2 MHz repetition, is illustrated through splitting of diffraction peaks, and interpreted employing finite element modeling of the sample chamber in the DAC.

9.
ESMO Open ; 6(3): 100132, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33940348

RESUMEN

BACKGROUND: Metastatic small bowel adenocarcinoma (SBA) has a poor prognosis. Due to its rarity, high-quality data are lacking to guide treatment. This retrospective analysis was conducted to help characterize the treatment options for patients with metastatic SBA while providing clinically meaningful prognostic information. PATIENTS AND METHODS: In total, 437 patients who initially presented with or developed metastatic SBA between September 1977 and September 2019 were identified from the MD Anderson Tumor Registry. Clinical data were collected from review of the medical record. Overall response rates (ORR), time to progression (TTP), and overall survival (OS) were assessed across various treatments and treatment lines. RESULTS: The median OS from diagnosis of metastatic disease was 15.9 months [95% confidence interval (CI): 14.3-17.9]. Seventy-five patients (17.1%) underwent metastasectomy, which was associated with a median OS of 34.5 versus 17.1 months among patients who received chemotherapy alone (P < 0.001). Fluoropyrimidine plus platinum (n = 164) was the most common first-line chemotherapy, associated with an ORR of 59% and TTP of 8.1 months. Irinotecan with 5-FU (n = 101) was the most common second-line therapy associated with an ORR of 31% and TTP of 4.0 months. Twenty-two patients received immunotherapy; 5 of 6 patients with deficient mismatch repair (dMMR) responded, while 0 of 16 with proficient mismatch repair (pMMR) responded. Taxane-based chemotherapy was given to 34 patients with an ORR of 21% and a median TTP of 2.4 months. Among 11 patients who received anti-epidermal-growth-factor-receptor (EGFR) monotherapy, the best response was stable disease (SD) in 1 patient. CONCLUSIONS: In well-selected patients with SBA, metastasectomy appears to be associated with improved OS. This improvement was seen across metastasectomy sites, including liver, lung and peritoneal. Anti-programmed cell death protein 1 (PD-1) based immunotherapy was active for dMMR SBA but not pMMR SBA. While taxane-based chemotherapy demonstrates therapeutic activity, the activity of anti-EGFR therapy was limited.


Asunto(s)
Adenocarcinoma , Neoplasias Intestinales , Metastasectomía , Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/cirugía , Humanos , Neoplasias Intestinales/tratamiento farmacológico , Neoplasias Intestinales/cirugía , Intestino Delgado/cirugía , Estudios Retrospectivos
10.
Appl Radiat Isot ; 174: 109743, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33915348

RESUMEN

A new movable 3PM-γ coincidence system, based on 4πß(LS)-γ coincidence counting, for activity measurement of ß-γ emitters has been designed at the Korea Research Institute of Standards and Science (KRISS). The system incorporates 3 PM tubes on the plane and two detectors placed above and below the center of the plane. The 3 PM tubes for ß-counters in the plane are movable up to 100 mm from a liquid scintillation vial, thus enabling the variation of ß-detection efficiencies by a geometrical technique. A NaI(Tl) γ-counter was set above for the present work. The ß-event is determined by counting the logical sum of three double coincidences. All the necessary electronics, i.e., logical sum, adjusting the duration of dead-time of each counting channel and coincidence resolving times, and analyzing coincidence relation, were specially designed to be fabricated in an integrated circuit. Details of the detectors, the electronics, the overall movable 3PM-γ coincidence system are presented, as well as the results of investigations to assess its operating characteristics. Validation measurements have been performed with 60Co and 57Co sources. The highest ß-detection efficiency achieved with 60Co and 57Co was 97% and 95%, respectively. The activity concentration determined with a new system agreed with calibrated values within the uncertainty range. Further results from validation measurements and the corresponding uncertainty budgets are presented.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA