RESUMEN
OBJECTIVE: Three-dimensional (3D) printed temporal bone model draws great attention as a promising alternative for conventional cadaveric model in education of otologic surgery. However, its high price and requirement for specialized tools hinder widespread use. We devised a simple educational model based on lattice structure to overcome these problems and compared it with a commercial model. METHODS: We converted high-resolution temporal bone computed tomography images into stereolithography format, and printed it using the G005 3D printing system from CUBICON©. In this process, the part to be drilled out was made of lattice structure. We evaluated the model by a questionnaire prepared in advance, and compared the results with those of a commercial model. RESULTS: We created an educational 3D printed temporal bone lattice model one-tenth the cost of commercial temporal bone. Our model reproduced the important structures of the temporal bone, produced less dust, and had similar strength and grinding sensation compared to the commercial model. The surface texture and reproducibility were comparable to the commercial model. Although most of structures were remodeled more elaborately in the commercial model than our model, our model demonstrated significant potential as a cost-effective educational tool for medical students and residents. CONCLUSION: 3D printed temporal bone lattice model has potential for widespread use due to low cost and easy accessibility. Further improvements in the fine structures of the temporal bone are necessary to enhance its utility as an educational model.
RESUMEN
Although the adverse effects of long-term use of vitamin K oral anticoagulant (OAC), warfarin, on the coronary vasculature are well-established, it remains unknown whether nonvitamin K oral anticoagulants play a role in the attenuation of plaque progression and coronary calcification. This study aimed to compare the changes in atherosclerotic plaques and calcification of the coronary arteries in patients with atrial fibrillation (AF) treated with edoxaban and warfarin. A total of 150 OAC-naïve patients with AF and atherosclerotic lesions on coronary computed tomography angiography (CCTA) were enrolled and randomly assigned to the edoxaban or warfarin treatment groups. All enrolled patients received rosuvastatin 10 mg and 119 patients completed the entire study protocol. A total of 12 months after the assigned OAC treatment, follow-up CCTA was performed and changes in plaque and calcium volumes of the coronary arteries were analyzed. The baseline characteristics of the 2 groups were well-balanced. The percentage of time in therapeutic range in the warfarin group was 61.1%. Compared with the baseline CCTA, there was a significant reduction in plaque volume after 12 months of OAC and rosuvastatin administration in both groups, and the extent of regression did not differ significantly between the groups. The increase in calcium volume was greater in the warfarin group than in the edoxaban group; however, the difference was not significant. In OAC-naïve patients with AF and atherosclerotic coronary lesions who were treated with moderate-intensity statin, edoxaban use did not have a positive effect on atherosclerotic plaques and coronary calcification compared with warfarin use over a 12-month follow-up period.
Asunto(s)
Anticoagulantes , Fibrilación Atrial , Enfermedad de la Arteria Coronaria , Progresión de la Enfermedad , Inhibidores del Factor Xa , Placa Aterosclerótica , Piridinas , Tiazoles , Calcificación Vascular , Warfarina , Humanos , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/complicaciones , Masculino , Femenino , Tiazoles/uso terapéutico , Warfarina/uso terapéutico , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Anciano , Piridinas/uso terapéutico , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/complicaciones , Inhibidores del Factor Xa/uso terapéutico , Anticoagulantes/uso terapéutico , Calcificación Vascular/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Persona de Mediana Edad , Vasos Coronarios/diagnóstico por imagen , Estudios de SeguimientoRESUMEN
Blooming artifacts caused by calcifications appearing on computed tomography (CT) images lead to an underestimation of the coronary artery lumen size, and higher X-ray energy levels are suggested to reduce the blooming artifacts with subjective visual assessment. This study aimed to evaluate the effect of higher X-ray energy levels on the quantitative measurement of adjacent pixels affected by calcification using CT images. In this two-part study, CT images were acquired from dual-energy CT scanners by changing the X-ray energy levels such as kilovoltage peak (kVp) and kilo-electron volts (keV). Adjacent pixels affected by calcification were measured using the brightened length, excluding the actual calcified length, as determined by the full width at third maximum. In a separate clinical study, the adjacent affected pixels associated with 23 calcifications across 10 patients were measured using the same method as that used in the phantom study. Phantom and clinical studies showed that the change in kVp (field of view [FOV] 300 mm: p = 0.167, 0.494, and 0.861 for vendors 1, 2, and 3, respectively) and keV levels (p = 0.178 for vendor 2) failed to reduce the adjacent pixels affected by calcification, respectively. Moreover, the change in keV levels showed different aspects of adjacent pixels affected by calcification in the phantom study (FOV 300 mm: no significant difference [p = 0.191], increase [p < 0.001], and decrease [p < 0.001] for vendors 1, 2, and 3, respectively). Quantitative measurements revealed no significant relationship between higher X-ray energy levels and the adjacent pixels affected by calcification.
Asunto(s)
Artefactos , Calcinosis , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Calcinosis/diagnóstico por imagen , Masculino , Femenino , Persona de Mediana Edad , Anciano , Vasos Coronarios/diagnóstico por imagen , Rayos XRESUMEN
Automatic segmentation of the coronary artery using coronary computed tomography angiography (CCTA) images can facilitate several analyses related to coronary artery disease (CAD). Accurate segmentation of the lumen or plaque region is one of the most important factors. This study aimed to analyze the performance of the coronary artery segmentation of a software platform with a deep learning-based location-adaptive threshold method (DL-LATM) against commercially available software platforms using CCTA. The dataset from intravascular ultrasound (IVUS) of 26 vessel segments from 19 patients was used as the gold standard to evaluate the performance of each software platform. Statistical analyses (Pearson correlation coefficient [PCC], intraclass correlation coefficient [ICC], and Bland-Altman plot) were conducted for the lumen or plaque parameters by comparing the dataset of each software platform with IVUS. The software platform with DL-LATM showed the bias closest to zero for detecting lumen volume (mean difference = -9.1 mm3, 95% confidence interval [CI] = -18.6 to 0.4 mm3) or area (mean difference = -0.72 mm2, 95% CI = -0.80 to -0.64 mm2) with the highest PCC and ICC. Moreover, lumen or plaque area in the stenotic region was analyzed. The software platform with DL-LATM showed the bias closest to zero for detecting lumen (mean difference = -0.07 mm2, 95% CI = -0.16 to 0.02 mm2) or plaque area (mean difference = 1.70 mm2, 95% CI = 1.37 to 2.03 mm2) in the stenotic region with significantly higher correlation coefficient than other commercially available software platforms (p < 0.001). The result shows that the software platform with DL-LATM has the potential to serve as an aiding system for CAD evaluation.
Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Aprendizaje Profundo , Placa Aterosclerótica , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Ultrasonografía Intervencional , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angiografía Coronaria/métodos , Reproducibilidad de los Resultados , Vasos Coronarios/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Anciano , Estudios RetrospectivosRESUMEN
OBJECTIVE: To investigate performance of 1-mm, sharp kernel, low-dose chest computed tomography (LDCT) for coronary artery calcium scoring (CACS) using deep learning (DL)-based denoising technique. METHODS: This retrospective, intra-individual comparative study consisted of four image datasets of 131 participants who underwent LDCT and calcium CT on the same day between January and February 2020; 1-mm LDCT with DL, 1-mm LDCT with iterative reconstruction (IR), 3-mm LDCT, and calcium CT. CACS from calcium CT were considered as reference and CACS were categorized as 0, 1-10, 11-100, 101-400, and > 400. We compared CACS from LDCTs with that from calcium CT. RESULTS: Mean CACS was 104.8 ± 249.1 and proportion of positive CACS was 45% (59/131). CACS from LDCT images tended to be underestimated than those from calcium CT: 1-mm LDCT with DL (93.5 ± 249.6, p = 0.002), 1-mm LDCT with IR (94.7 ± 249.9, p < 0.001), and 3-mm LDCT (90.3 ± 245.3, p = 0.004). All LDCT datasets showed excellent agreement with calcium CT: intraclass correlation coefficient (ICC) = 0.961 (95% confidence interval (CI), 0.945-0.972) for DL, 0.969 (95% CI, 0.956-0.978) for IR, and 0.952 (95% CI, 0.932-0.966) for 3-mm LDCT; weighted kappa for CACS classification, 0.930 (95% CI, 0.893-0.966) for 1-mm LDCT with DL, 0.908 (95% CI, 0.866-0.950) for 1-mm LDCT with IR, and 0.846 (95% CI, 0.780-0.912) for 3-mm LDCT. The accuracy of CACS classification of 1-mm LDCT with DL (90%) tended to be better than 1-mm LDCT with IR (87%) and 3-mm LDCT (84.7%) (p = 0.10). CONCLUSION: DL-based noise reduction algorithm can offer reliable calcium scores in 1-mm LDCT reconstructed with sharp kernel. KEY POINTS: ⢠Deep learning (DL)-based noise reduction enables calcium scoring at 1-mm, sharp kernel reconstructed low-dose chest CT (LDCT). ⢠Both iterative reconstruction and DL-based noise reduction underestimated calcium score, but agreement were excellent with those from calcium CT. ⢠Accuracy of categorical classification of calcium scoring tended to be highest in 1-mm LDCT with DL compared to 1-mm LDCT with IR and 3-mm LDCT (90%, 87%, and 84.7%, p = 0.10).
Asunto(s)
Enfermedad de la Arteria Coronaria , Aprendizaje Profundo , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Calcio , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodosRESUMEN
OBJECTIVE: To evaluate the impact of surgical simulation training using a three-dimensional (3D)-printed model of tetralogy of Fallot (TOF) on surgical skill development. MATERIALS AND METHODS: A life-size congenital heart disease model was printed using a Stratasys Object500 Connex2 printer from preoperative electrocardiography-gated CT scans of a 6-month-old patient with TOF with complex pulmonary stenosis. Eleven cardiothoracic surgeons independently evaluated the suitability of four 3D-printed models using composite Tango 27, 40, 50, and 60 in terms of palpation, resistance, extensibility, gap, cut-through ability, and reusability of. Among these, Tango 27 was selected as the final model. Six attendees (two junior cardiothoracic surgery residents, two senior residents, and two clinical fellows) independently performed simulation surgeries three times each. Surgical proficiency was evaluated by an experienced cardiothoracic surgeon on a 1-10 scale for each of the 10 surgical procedures. The times required for each surgical procedure were also measured. RESULTS: In the simulation surgeries, six surgeons required a median of 34.4 (range 32.5-43.5) and 21.4 (17.9-192.7) minutes to apply the ventricular septal defect (VSD) and right ventricular outflow tract (RVOT) patches, respectively, on their first simulation surgery. These times had significantly reduced to 17.3 (16.2-29.5) and 13.6 (10.3-30.0) minutes, respectively, in the third simulation surgery (p = 0.03 and p = 0.01, respectively). The decreases in the median patch appliance time among the six surgeons were 16.2 (range 13.6-17.7) and 8.0 (1.8-170.3) minutes for the VSD and RVOT patches, respectively. Summing the scores for the 10 procedures showed that the attendees scored an average of 28.58 ± 7.89 points on the first simulation surgery and improved their average score to 67.33 ± 15.10 on the third simulation surgery (p = 0.008). CONCLUSION: Inexperienced cardiothoracic surgeons improved their performance in terms of surgical proficiency and operation time during the experience of three simulation surgeries using a 3D-printed TOF model using Tango 27 composite.