Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
3.
QJM ; 111(10): 745-746, 2018 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-29660083
4.
Bone Joint J ; 99-B(8): 1047-1052, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28768781

RESUMEN

AIMS: The aim of this study was to evaluate the effects of using a portable, accelerometer-based surgical navigation system (KneeAlign2) in total knee arthroplasty (TKA) on the alignment of the femoral component, and blood loss. PATIENTS AND METHODS: A total of 241 consecutive patients with primary osteoarthritis of the knee were enrolled in this prospective, randomised controlled study. There were 207 women and 34 men. The mean age of the patients was 74.0 years (57 to 89). The KneeAlign2 system was used for distal femoral resection in 121 patients (KA2 group) and a conventional intramedullary femoral guide was used in 120 patients (IM group). RESULTS: One patient (0.8%) in the KA2 group and 19 in the IM group had an alignment which was > 3° away from the neutral mechanical axis (p < 0.01). The mean deviation from neutral alignment was 1.01° (standard deviation (sd) 1.0°) in the KA2 group and 1.93° (sd 1.7°) in the IM group (p < 0.01). Blood loss was significantly less in the KA2 group compared with the IM group (784 ml (sd 357) versus 1071 ml (sd 310), p < 0.001). CONCLUSION: The KneeAlign2 system provides a technically straightforward method for identifying the femoral head and performing an accurate distal femoral resection at TKA with significantly less blood loss compared with a conventional intramedullary guide. Cite this article: Bone Joint J 2017;99-B:1047-52.


Asunto(s)
Acelerometría/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico , Estudios Prospectivos , Radiografía , Resultado del Tratamiento
5.
QJM ; 109(7): 495, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27247430
6.
Nat Commun ; 2: 594, 2011 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-22186890

RESUMEN

The study of carrier multiplication has become an essential part of many-body physics and materials science as this multiplication directly affects nonlinear transport phenomena, and has a key role in designing efficient solar cells and electroluminescent emitters and highly sensitive photon detectors. Here we show that a 1-MVcm(-1) electric field of a terahertz pulse, unlike a DC bias, can generate a substantial number of electron-hole pairs, forming excitons that emit near-infrared luminescence. The bright luminescence associated with carrier multiplication suggests that carriers coherently driven by a strong electric field can efficiently gain enough kinetic energy to induce a series of impact ionizations that can increase the number of carriers by about three orders of magnitude on the picosecond time scale.


Asunto(s)
Electrónica/métodos , Electricidad , Electrónica/instrumentación , Electrones , Rayos Infrarrojos , Luminiscencia , Dispositivos Ópticos , Fotones , Radiación Terahertz , Termodinámica
7.
Opt Express ; 19(9): 8277-84, 2011 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-21643077

RESUMEN

We report a terahertz near-field microscope with a high dynamic range that can capture images of a 370 x 740 µm2 area at 35 frames per second. We achieve high spatial resolution (14 µm corresponding to λ/30 for a center frequency at 0.7 THz) on a large area by combining two novel techniques: terahertz generation by tilted-pulse-front excitation and electro-optic balanced imaging detection using a thin crystal. To demonstrate the microscope capability, we reveal the field enhancement at the gap position of a dipole antenna after the irradiation of a terahertz pulse.


Asunto(s)
Aumento de la Imagen/instrumentación , Microscopía/instrumentación , Imágen por Terahertz/instrumentación , Sistemas de Computación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Blood Purif ; 27(3): 253-60, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19218793

RESUMEN

AIMS: The higher ultrafiltration (UF) induces poor outcomes. The impact of higher UF on the volume status was investigated. METHODS: 60 hemodialysis (HD) patients were divided into three groups according to the ratio of total UF to post-dialysis body weight (TUF/PDW) (<3%, 3-5%, > or =5%). ANP, the ratio of extracellular water to total body water and excess fluid mass (ExF/PDW) by bioimpedance spectroscopy, inferior vena cava diameter by ultrasound were measured at the end of HD. The ratio of post-HD blood volume to pre-HD (BVpost/BVpre) and standardized filtration coefficients (Lpst) of the microvasculature in the vicinity of PDW were calculated. RESULTS: Only Lpst and BVpost/BVpre showed significant differences among the three groups. A stepwise multiple linear regression model revealed that BVpost/BVpre was correlated with TUF/PDW, ExF/PDW and Lpst (R = 0.778, p < 0.001), independently. CONCLUSION: Higher UF causes decreases in BVpost/BVpre and Lpst. BVpost/BVpre was determined by TUF/PDW, ExF/PDW and Lpst.


Asunto(s)
Volumen Sanguíneo , Diálisis Renal/métodos , Ultrafiltración/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Agua Corporal , Impedancia Eléctrica , Líquido Extracelular , Espacio Extracelular , Humanos , Persona de Mediana Edad , Ultrasonografía , Vena Cava Inferior/diagnóstico por imagen , Equilibrio Hidroelectrolítico
9.
J Phys Condens Matter ; 19(40): 406224, 2007 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-22049122

RESUMEN

We performed optical-pump terahertz-probe measurements of a Mott insulator YTiO(3) and a band semiconductor Si using a laser diode (1.47 eV) and a femtosecond-pulse laser (1.55 eV). Both samples possess long energy-relaxation times (1.5 ms for YTiO(3) and 15 µs for Si); therefore, it is possible to extract terahertz complex conductivities of photoinduced carriers under equilibrium. We observed highly contrasting behaviour-Drude conductivity in Si and localized conductivity possibly obeying the Jonscher law in YTiO(3). The carrier number at the highest carrier-concentration layer in YTiO(3) is estimated to be 0.015 per Ti site. Anisotropic conductivity of YTiO(3) is determined. Our study indicates that localized carriers might play an important role in the incipient formation of photoinduced metallic phases in Mott insulators. In addition, this study shows that the transfer-matrix method is effective for extracting an optical constant of a sample with a spatially inhomogeneous carrier distribution.

10.
J Bone Joint Surg Br ; 88(10): 1327-30, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17012422

RESUMEN

The shape of the flexion gap in 20 normal knees was evaluated by axial radiography of the distal femur, and the results compared with those obtained in a previous study by MRI. The observed asymmetry was reduced by 29% using radiography, with a mean value of 3.6 degrees (1.5 degrees to 6.3 degrees) compared with that obtained by MRI of 5.1 degrees (2.6 degrees to 9.5 degrees), a mean discrepancy of 1.49 degrees. The results obtained by radiography and MRI showed a strong correlation (r = 0.78). Axial radiography is acceptable for the evaluation of the flexion gap and is less expensive and more comfortable to perform than MRI. Additionally, no metallic artefact occurs when the radiological method is used for assessment after arthroplasty.


Asunto(s)
Fémur/diagnóstico por imagen , Articulación de la Rodilla/diagnóstico por imagen , Adolescente , Adulto , Femenino , Fémur/patología , Humanos , Articulación de la Rodilla/patología , Masculino , Persona de Mediana Edad , Radiografía
11.
J Bone Joint Surg Br ; 86(8): 1133-6, 2004 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-15568525

RESUMEN

Varus and valgus joint laxity of the normal living knee in flexion was assessed using MRI. Twenty knees were flexed to 90 degrees and were imaged in neutral and under a varus-valgus stress in an open MRI system. The configuration of the tibiofemoral joint gap was studied in slices which crossed the epicondyles of the femur. When a varus stress was applied, the lateral joint gap opened by 6.7 +/- 1.9 mm (mean +/- SD; 2.1 to 9.2) whereas the medial joint gap opened by only by a mean of 2.1 +/- 1.1 mm (0.2 to 4.2). These discrepancies indicate that the tibiofemoral flexion gap in the normal knee is not rectangular and that the lateral joint gap is significantly lax. These results may be useful for adequate soft-tissue balancing and bone resection in total knee arthroplasty and reconstruction surgery on ligaments.


Asunto(s)
Articulación de la Rodilla/anatomía & histología , Postura/fisiología , Adolescente , Adulto , Femenino , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estrés Mecánico
12.
J Bone Joint Surg Am ; 85(7): 1238-42, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12851348

RESUMEN

BACKGROUND: Little information is available on the kinematics of the normal knee in deep flexion. The purpose of this study was to use magnetic resonance imaging to analyze the patellofemoral articulation in deep flexion. METHODS: Axial scans were made of the patellofemoral joint of twenty healthy Japanese volunteers with the knee in approximately 90 degrees of flexion, in maximum active flexion (mean [and standard deviation], 140 degrees +/- 10 degrees ), and in maximum passive flexion (mean, 156 degrees +/- 5 degrees ). A fat-suppressed, three-dimensional, fast low-angle shot sequence was used to visualize the articular cartilage. The patellofemoral contact area was determined on sequential images and was reconstructed three-dimensionally. RESULTS: At 90 degrees of flexion, the contact area on the patella was continuous over the medial and lateral facets in fourteen knees and was located in the proximal half of the articular surface. At maximum active and passive flexion, the odd facet engaged in fifteen and eighteen knees, respectively. At maximum passive flexion, the contact area of the lateral facet moved distally and decreased significantly (p = 0.0002). From 90 degrees of flexion to maximum active flexion, the mean total contact area remained constant (3.43 +/- 0.70 and 3.62 +/- 0.72 cm (2), respectively); it then decreased significantly in maximum passive flexion (2.96 +/- 0.78 cm (2), p = 0.04). CONCLUSIONS: The contact area on the patella was divided into two parts (the odd and lateral facets) and moved distally in deep knee flexion. The size of the contact area on the lateral facet significantly decreased in maximum passive flexion.


Asunto(s)
Articulación de la Rodilla/fisiología , Imagen por Resonancia Magnética , Rótula/fisiología , Rango del Movimiento Articular , Actividades Cotidianas , Adulto , Fenómenos Biomecánicos , Femenino , Fémur/fisiología , Humanos , Japón , Prótesis de la Rodilla , Estilo de Vida , Imagen por Resonancia Magnética/métodos , Masculino , Diseño de Prótesis , Rotación , Tibia/fisiología , Soporte de Peso
13.
J Arthroplasty ; 17(8): 1028-32, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12478514

RESUMEN

Anthropometric data on proximal tibiae of 100 knees in 80 Japanese patients undergoing total knee arthroplasty were obtained. Anterior-posterior (AP) and medial-lateral (ML) lengths of the tibia were measured on computed tomography scans and intraoperatively on tibial resection surfaces. A special small component is unnecessary, and size variation should focus on ML length of 65 to 75 mm because this includes 90% of women's knees. AP-to-ML ratio had a negative correlation with ML length, indicating that small knees were longer in the AP direction. Most prostheses had AP mismatch up to 5 mm for small women's knees. These data could provide the basis for designing the optimal tibial component for most of the Asian-Pacific population.


Asunto(s)
Antropometría , Prótesis de la Rodilla , Tibia/anatomía & histología , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla , Pueblo Asiatico , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Diseño de Prótesis
14.
Clin Orthop Relat Res ; (402): 196-201, 2002 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-12218484

RESUMEN

The purpose of the current study was to investigate the bone anatomy in determining the rotational alignment in total knee arthroplasty using computed tomography. Axial images of 109 knees in 83 patients with varus osteoarthritis who had total knee arthroplasty were analyzed. On the images of the distal femur and the proximal tibia, a baseline for the anteroposterior axis of each component was drawn based on the epicondylar axis for the femur and the medial (1/3) of the tibial tuberosity for the tibia. The angle between these two lines was analyzed as the rotational mismatch between the components when they were aligned to the anatomic landmarks of each bone. Fifty-four knees (49.5%) had an angle of 5 degrees or greater and 13 knees (11.9%) had an angle of 10 degrees or greater. There was a tendency to align the tibial component in external rotation relative to the femoral component. The results indicated that the landmarks of each bone were the intrinsic cause of the rotational mismatch in knees with varus osteoarthritis. Surgeons doing total knee arthroplasties should be aware of this and check the rotational mismatch between the components. When it is present, the tibial component should be realigned to match the femoral component rotation to minimize problems caused by the mismatch.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Desviación Ósea/etiología , Osteoartritis de la Rodilla/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Fémur/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Rótula , Radiografía , Rotación , Tibia/diagnóstico por imagen , Resultado del Tratamiento
15.
FEBS Lett ; 509(3): 382-8, 2001 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-11749960

RESUMEN

The induction of apoptosis by cell cycle regulator molecules under conditions optimal for exponential growth was examined in rat pheochromocytoma PC12 cells by overexpression of cyclins and cyclin-dependent kinases (cdks). By flow cytometry and by immunofluorescence, only cells overexpressing cdk4 or cyclin D1 underwent apoptosis, which was not associated with G1-arrest. Cdk4 kinase activity was significantly higher in cdk4-, or cyclin D1-expressing cells. Furthermore, induction of apoptosis by cdk4 was abrogated by co-transfection of p16(INK4), or dominant negative cdk4. These results suggest that upregulation of cdk4 kinase activity is a primary and critical mediator of apoptosis in PC12 cells under physiological conditions.


Asunto(s)
Apoptosis , Ciclina D1/metabolismo , Quinasas Ciclina-Dependientes/metabolismo , Proteínas Proto-Oncogénicas , Animales , Bromodesoxiuridina/metabolismo , Tamaño de la Célula , Ciclina D1/genética , Quinasa 4 Dependiente de la Ciclina , Inhibidor p16 de la Quinasa Dependiente de Ciclina/metabolismo , Quinasas Ciclina-Dependientes/antagonistas & inhibidores , Quinasas Ciclina-Dependientes/genética , Citometría de Flujo , Fluoresceína-5-Isotiocianato , Fase G1 , Expresión Génica , Genes Dominantes , Mutación , Células PC12 , Ratas , Factores de Tiempo
17.
Clin Orthop Relat Res ; (391): 210-7, 2001 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11603671

RESUMEN

The effect of posterior cruciate ligament resection on the tibiofemoral joint gap was analyzed in 30 patients with varus osteoarthritis of thee knee who underwent total knee replacement. The medial soft tissue was released and the bone cut was made without preserving the bone segment of the tibia to which the posterior cruciate ligament was attached. Then the medial and lateral joint gaps in full extension and 90 degrees flexion were measured before and after the posterior cruciate ligament was resected using a tensioning device. After the resection, the flexion gap significantly increased in the medial and the lateral sides (4.8 +/- 0.4 and 4.5 +/- 0.4 mm, respectively, mean +/- standard error) compared with those seen in the extension gap (0.9 +/- 0.2 and 0.8 +/- 0.2 mm). There was no significant difference between the changes in the medial and lateral gaps. The mean value of the flexion gap was 2 mm smaller than the extension gap before the resection and 1.7 mm larger after the sacrifice. Overall, posterior cruciate ligament resection resulted in an increase in the flexion gap and made space for approximately 3-mm thicker polyethylene. The flexion gap can be controlled selectively with posterior cruciate ligament release.


Asunto(s)
Fémur , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Ligamento Cruzado Posterior/cirugía , Tibia , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Fémur/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/fisiopatología , Examen Físico/instrumentación , Rango del Movimiento Articular , Tibia/fisiopatología
18.
J Arthroplasty ; 16(6): 784-9, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11547378

RESUMEN

Results of total hip arthroplasties with a modified cementing technique using hydroxyapatite were evaluated. Femoral and acetabular components were inserted with cement after hydroxyapatite granules (phi = 100-300 microm). The study group comprised 268 hips in 232 patients. The diagnosis was osteoarthritis in 197 patients. After a mean follow-up of 10.3 years, 5 patients died and 30 patients were lost to follow-up, leaving 218 hips (197 patients; mean age, 58.2 years) for evaluation. Three hips were revised because aseptic (1) and septic (2) loosening of acetabular components. Six other sockets were defined as radiologically loose, and no femoral component was loose. Osteolysis was identified in 2 femora and 0 acetabula. The overall loosening rate was 3.2% for acetabular components and 0% for femoral components. These results show that the loosening rate of cemented total hip arthroplasty components, especially the acetabulum, is reduced markedly with this modified cementing technique.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Durapatita , Osteoartritis de la Cadera/cirugía , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/diagnóstico por imagen , Osteólisis/cirugía , Diseño de Prótesis , Falla de Prótesis , Radiografía , Reoperación , Instrumentos Quirúrgicos
19.
J Biomech ; 34(8): 1031-7, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11448695

RESUMEN

The relationship between the coefficient of friction and pH value or protein constituents of lubricating fluid, together with viscosity, were studied within a bearing surface model for artificial joint, ultra-high molecular weight polyethylene (UHMWPE) against stainless steel (SUS), using a mechanical spectrometer. Four lubricants were tested in this study: sodium hyaluronate (HA), HA with albumin, HA with gamma-globulin, and HA with (L)alpha-dipalmitoyl phosphatidylcholine ((L)alpha-DPPC). The coefficient of friction between UHMWPE and SUS in HA with albumin or HA with gamma-globulin varied from 0.035 to 0.070 depending on angular velocity and pH. The coefficient of friction in HA or HA with (L)alpha-DPPC varied from 0.023 to 0.045 depending on angular velocity and pH. The variation in pH for HA with albumin had a large effect on the coefficient of friction at low range of angular velocity with viscosity independence. The variation in pH for HA with gamma-globulin had a large effect on the coefficient of friction with viscosity dependence at high angular velocity. The addition of (L)alpha-DPPC showed a small effect on the coefficient of friction at low angular velocity. This study confirms that the presence of albumin in the lubricant promotes pH dependence and viscosity independence of the tribological properties at low speed while the presence of globulin promotes pH and viscosity independence at low speed and promotes pH and viscosity dependence at high speed in the lubrication of UHMWPE against SUS. This study supports the clinical hypothesis that the effect of constituents and pH changes in periprosthetic fluid for the lubrication is a clue toward resolving many complications after total joint replacement.


Asunto(s)
Ácido Hialurónico/química , Prótesis Articulares , 1,2-Dipalmitoilfosfatidilcolina/química , Albúminas/química , Fricción , Humanos , Concentración de Iones de Hidrógeno , Lubrificación , Polietilenos , Acero Inoxidable , Estadística como Asunto , Viscosidad , gammaglobulinas/química
20.
J Biomed Mater Res ; 58(2): 167-71, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11241335

RESUMEN

The purpose of this study was to evaluate the mechanical and chemical characteristics of gamma-irradiated, cross-linked polyethylene after long-term service in vivo. Two gamma-irradiated ultra high molecular weight polyethylene (RCH 1000, molecular weight: 10(6)) total hip replacement sockets were retrieved at 15 and 16 years after implantation. Mechanical and chemical characteristics of the sockets were evaluated in comparison with nonirradiated sockets. Significant surface oxidation occurred in the nonirradiated sockets; up to 75% of that seen in the irradiated ones. The mechanical properties of the irradiated sockets were not subject to increased deterioration in the presence of high free radical content. The cross-link was stable and was retained for a long period both in vivo and in ambient air. These data indicate that gamma-irradiated polyethylene was not subject to increased oxidative degradation during long-term service in vivo and confirmed the usefulness of this material as an articulating surface in total hip replacement.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Materiales Biocompatibles , Polietileno , Reactivos de Enlaces Cruzados , Rayos gamma , Humanos , Prótesis e Implantes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA