Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Base de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Magn Reson Imaging ; 111: 202-209, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38547936

RESUMEN

BACKGROUND: We devised a method that combines the 3D-Dixon-gradientecho (GRE) method with an improved motion-sensitized driven-equilibrium (iMSDE) to suppress blood flow signals. PURPOSE: The purpose of this study was to evaluate the effectiveness of the new method we developed plaque imaging method (3D-Dixon-GRE with the iMSDE method). STUDY TYPE: Retrospective cohort. POPULATION: Thirty-nine patients who underwent cervical plaque imaging. FIELD STRENGTH/SEQUENCE: 3.0 T/3D-GRE. ASSESSMENT: Signal intensities of the common carotid artery, aorta, plaque, muscle, and subcutaneous fat were measured through the VISTA and the 3D-Dixon-GRE with iMSDE methods, and each contrast was calculated. STATISTICAL TEST: Used the Mann Whitney U test. P-values below 0.05 were considered statistically significant. RESULTS: Plaque and muscle contrast estimated through the VISTA method and 3D-Dixon-GRE with iMSDE method was 1.60 ± 0.96 and 2.04 ± 1.06, respectively, (P < 0.05). The contrast between the flow (common carotid artery and Aorta) and muscle according to the VISTA method and 3D-Dixon-GRE with iMSDE method was 0.24 ± 0.11 and 0.40 ± 0.12, respectively (P < 0.001). Finally, the mean contrast for subcutaneous fat and muscle at six locations was 3.05 ± 1.25 and 0.81 ± 0.23 for the VISTA method and 3D-Dixon-GRE with the iMSDE method, respectively (P < 0.001). DATA CONCLUSION: Compared to the conventional method (VISTA), the 3D-Dixon-GRE with iMSDE method is preferable in relation to the fat suppression effect, but it is disadvantageous regarding blood flow signal suppression. Therefore, the 3D-Dixon-GRE with the iMSDE method could be considered useful for plaque imaging.


Asunto(s)
Imagenología Tridimensional , Placa Aterosclerótica , Humanos , Femenino , Masculino , Imagenología Tridimensional/métodos , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Aorta/diagnóstico por imagen , Arterias Carótidas/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Anciano de 80 o más Años
2.
J Appl Clin Med Phys ; 24(12): e14205, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37975638

RESUMEN

In magnetic resonance imaging (MRI), it is necessary to reduce image distortion as much as possible because it suppresses the increase in the planning target volume. This study investigated the relationship between imaging parameters and image distortion when using G-frames. The images were obtained using a 1.5-T MRI system with a 09-101 Pro-MRI phantom. Image distortion was measured by changing the RF pulse mode, gradient mode, asymmetric echo, and bandwidth (BW). The image distortion was increased in the high RF mode than in the Normal mode. The image distortion increased in the following order: Whisper â‰¦ Normal < Fast in the different gradient modes. The image distortion increased in the following order: Without â‰¦ Weak < Strong in the different asymmetric echo modes. The image distortion increased in the following order: 300 Hz/pixel > 670 Hz/pixel â‰§ REF (150 Hz/pixel) in the different Bw. The relationship between parameters and image distortion was clarified in this study when G-frames were used for gamma knife therapy. There is had relationship between the parameters causing variation in the gradient magnetic field and image distortion. Therefore, these parameters should be adjusted to minimize distortion.


Asunto(s)
Imagen por Resonancia Magnética , Radiocirugia , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos
3.
J Magn Reson ; 355: 107560, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37748233

RESUMEN

This study aimed to investigate the effect of using slice partial Fourier (SPF), phase partial Fourier (PPF), and radial scan (Elliptical scanning) methods on image quality. Changes in signal-to-noise ratio (SNR), effective slice thickness, and in-plane resolution were measured in 3D-gradient echo when SPF, PPF, and radial scan were used. Effective slice thickness increased and SNR increased when SPF was used; in-plane resolution decreased and SNR decreased when PPF was used; effective slice thickness did not change, in-plane resolution decreased, and SNR increased when the radial scan method was used. The radial scan method reduces image quality and imaging time compared to those in the SPF and PPF methods.

4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 78(6): 582-592, 2022 Jun 20.
Artículo en Japonés | MEDLINE | ID: mdl-35569957

RESUMEN

PURPOSE: This study investigated the effectiveness of assistive work of radiological technologists (RTs) in conducting computed tomography (CT)/magnetic resonance imaging (MRI) during emergencies. METHODS: In total, 2681 examinations in 2294 patients who underwent CT or MRI during our after-hours clinic hours were conducted. The emergency of the diseases was classified into three categories: emergency diseases, semi-emergency diseases, and non-emergency diseases. The reading report of the RTs group, resident physicians (RPs) group, and senior physicians (SPs) group were used to calculate the sensitivity, specificity, and accuracy. RESULTS: The RTs group had an accuracy of 87.0% for emergency and semi-emergency diseases. The sensitivity of the combined RTs/RPs/SPs group was higher than that of the RPs and SPs group alone. CONCLUSION: After-hours help from RTs for emergency and semi-emergency diseases enhanced sensitivity and thus demonstrated the effectiveness in emergency care.


Asunto(s)
Urgencias Médicas , Tomografía Computarizada por Rayos X , Humanos , Imagen por Resonancia Magnética , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA