2.
JACC Adv ; 3(8): 101116, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39108421

RESUMEN

Background: Transcatheter aortic valve replacement (TAVR) is an important treatment option for patients with severe symptomatic aortic stenosis. It is important to identify predictors of excellent outcomes (good clinical outcomes, more time spent at home) after TAVR that are potentially amenable to improvement. Objectives: The purpose of the study was to use machine learning to identify potentially modifiable predictors of clinically relevant patient-centered outcomes after TAVR. Methods: We used data from 8,332 TAVR cases (January 2016-December 2021) from 21 hospitals to train random forest models with 57 patient characteristics (demographics, comorbidities, surgical risk score, lab values, health status scores) and care process parameters to predict the end point, a composite of parameters that designated an excellent outcome and included no major complications (in-hospital or at 30 days), post-TAVR length of stay of 1 day or less, discharge to home, no readmission, and alive at 30 days. We used recursive feature elimination with cross-validation and Shapley Additive Explanation feature importance to identify parameters with the highest predictive values. Results: The final random forest model retained 29 predictors (15 patient characteristics and 14 care process components); the area under the curve, sensitivity, and specificity were 0.77, 0.67, and 0.73, respectively. Four potentially modifiable predictors with relatively high Shapley Additive Explanation values were identified: type of anesthesia, direct movement to stepdown unit post-TAVR, time between catheterization and TAVR, and preprocedural length of stay. Conclusions: This study identified four potentially modifiable predictors of excellent outcome after TAVR, suggesting that machine learning combined with hospital-level data can inform modifiable components of care, which could support better delivery of care for patients undergoing TAVR.

3.
Circ Cardiovasc Interv ; : e013782, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39034924

RESUMEN

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03193801.

4.
Ann Thorac Surg ; 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38878949

RESUMEN

BACKGROUND: The utility of operating room extubation (ORE) after cardiac surgery over fast-track extubation (FTE) within 6 hours remains contested. We hypothesized ORE would be associated with equivalent rates of morbidity and mortality, relative to FTE. METHODS: Patients undergoing nonemergent cardiac surgery were identified in The Society of Thoracic Surgeons Adult Cardiac Surgery Database between July 2017 and December 2022. Only procedures with The Society of Thoracic Surgeons risk models were included. Risk-adjusted outcomes of ORE and FTE were compared by observed-to-expected ratios with 95% CIs aggregated over all procedure types, and ORE vs FTE adjusted odds ratios (ORs) specific to each procedure type using multivariable logistic regression. Analyzed outcomes were operative mortality, prolonged length of stay, composite reoperation for bleeding and reintubation, and composite morbidity and mortality. RESULTS: The study population of 669,099 patients across 1069 hospitals included 36,298 ORE patients in 296 hospitals. Risk-adjusted analyses found that ORE was associated with statistically similar or better results across each of the 4 outcomes and procedure subtypes. Notably, rates of postoperative mortality were significantly lower in ORE patients undergoing coronary artery bypass grafting (OR, 0.54; 95% CI, 0.46-0.65), aortic valve replacement (OR, 0.43; 95% CI, 0.24-0.77), and mitral valve replacement (OR, 0.48; 95% CI, 0.26-0.89). CONCLUSIONS: Extubation in the OR was safe and effective in a selected patient population and may be associated with superior outcomes in coronary artery bypass, aortic valve replacement, and mitral valve replacement. These national data appear to confirm institutional experiences regarding the potential benefit of OR extubation. Further refinement of optimal populations may justify randomized investigation.

6.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Asunto(s)
Endocarditis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Endocarditis/cirugía , Endocarditis/mortalidad , Remoción de Dispositivos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
7.
Ann Thorac Surg ; 118(1): 155-162, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38580202

RESUMEN

BACKGROUND: Reports of cardiac operations after transcatheter aortic valve replacement (TAVR) and early TAVR explantation are increasing. The purpose of this report is to document trends and outcomes of cardiac surgery after initial TAVR. METHODS: The Society of Thoracic Surgeons Adult Cardiac Surgery Database was queried for all adult patients undergoing cardiac surgery after a previously placed TAVR between January 2012 and March 2023. This identified an overall cohort and 2 subcohorts: nonaortic valve operations and surgical aortic valve replacement (SAVR) after previous TAVR. Cohorts were examined with descriptive statistics, trend analyses, and 30-day outcomes. RESULTS: Of 5457 patients who were identified, 2485 (45.5%) underwent non-SAVR cardiac surgery, and 2972 (54.5%) underwent SAVR. The frequency of cardiac surgery after TAVR increased 4235.3% overall and 144.6% per year throughout the study period. The incidence of operative mortality and stroke were 15.5% and 4.5%, respectively. Existing The Society of Thoracic Surgeons risk models performed poorly, because observed-to-expected mortality ratios were significantly >1.0. Among those undergoing SAVR after TAVR, increasing preoperative surgical urgency, age, dialysis, need for SAVR, and concomitant procedures were associated with increased mortality, whereas type of TAVR explant was not. CONCLUSIONS: The need for cardiac surgery, including redo SAVR after TAVR, is increasing rapidly. Risks are higher, and outcomes are worse than predicted. These data should closely inform heart team decisions if TAVR is considered at lowering age and risk profiles in the absence of longitudinal evidence.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Complicaciones Posoperatorias/epidemiología , Reoperación/estadística & datos numéricos , Estados Unidos/epidemiología , Incidencia
9.
Artículo en Inglés | MEDLINE | ID: mdl-38657782

RESUMEN

OBJECTIVES: The long-term impact of permanent pacemaker (PPM) implantation on survival after cardiac surgery remains ill defined. We aimed to investigate the effect of PPM on survival and explore factors driving outcomes using meta-regression according to the type of surgery. METHODS: MEDLINE, EMBASE, and the Cochrane Library Central Register of Controlled Trials were searched through October 2023 to identify studies reporting the long-term outcomes of PPM implantation. The primary outcome was all-cause mortality during follow-up. The secondary outcome was heart failure rehospitalization. The subgroup analysis and meta-regression analysis were performed according to the type of surgery. RESULTS: A total of 28 studies met the inclusion criteria. 183,555 patients (n = 6298; PPM, n = 177,257; no PPM) were analyzed for all-cause mortality, with a weighted median follow-up of 79.7 months. PPM implantation was associated with increased risks of all-cause mortality during follow-up (hazard ratio, 1.22; confidence interval, 1.08-1.38, P < .01) and heart failure rehospitalization (hazard ratio, 1.24; confidence interval, 1.01-1.52, P = .04). Meta-regression demonstrated the adverse impact of PPM was less prominent in patients undergoing mitral or tricuspid valve surgery, whereas studies with a greater proportion with aortic valve replacement were associated with worse outcomes. Similarly, a greater proportion with atrioventricular block as an indication of PPM was associated with worse survival. CONCLUSIONS: PPM implantation after cardiac surgery is associated with a greater risk of long-term all-cause mortality and heart failure rehospitalization. This impact is more prominent in patients undergoing aortic valve surgery or atrioventricular block as an indication than those undergoing mitral or tricuspid valve surgery.

11.
JTCVS Tech ; 23: 63-71, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38351990

RESUMEN

Objective: The Impella 5.5 (Abiomed, Inc), a surgically implanted endovascular microaxial left ventricular assist device, is increasingly used worldwide and there have been more than 10,000 implants. The purpose of this study is to describe a large-volume, single-center experience with the use of the Impella 5.5. Methods: Data were obtained retrospectively from patients supported with the Impella 5.5 implanted at our institution from May 1, 2020, to December 31, 2022. Demographic, operative, and postoperative outcomes for each group are described. Results are reported in median (interquartile range) or n (%). The entire cohort was divided into 5 main groups based on the intention to treat at the time of the Impella 5.5 implantation: (1) patients who had a planned Impella 5.5 implanted at the time of high-risk cardiac surgery; (2) patients with cardiogenic shock; (3) patients bridged to a durable left ventricular assist device; (4) patients bridged to transplant; and (5) patients with postcardiotomy shock who received an unplanned Impella 5.5 implant. Results: A total of 126 patients were supported with the Impella 5.5. Overall survival to device explant was 76.2%, with 67.5% surviving to discharge. Midterm survival was assessed with a median follow-up time of 318 days and demonstrated an overall survival of 60.3% and a median of 650 days (549-752). Conclusions: Outcomes after using the Impella 5.5 are variable depending on the indication of use. Patient selection may be of utmost importance and requires further experience with this device to determine who will benefit from insertion.

12.
JACC Cardiovasc Interv ; 17(4): 505-515, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38340102

RESUMEN

BACKGROUND: A single, multitiered valve center designation has been proposed to publicly identify centers with expertise for all valve therapies. The correlation between transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (MTEER) procedures is unknown. OBJECTIVES: The authors sought to examine the relationship between site-level volumes and outcomes for TAVR and MTEER. We further explored variability between sites for MTEER outcomes. METHODS: Using the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) national registry, TAVR and MTEER procedures at sites offering both therapies from 2013 to 2022 were examined. Sites were ranked into deciles of adjusted in-hospital and 30-day outcomes separately for TAVR and MTEER and compared. Stepwise, hierarchical multivariable models were constructed for MTEER outcomes, and the median OR was calculated. RESULTS: Between 2013 and 2022, 384,394 TAVRs and 53,274 MTEERs (median annualized volumes: 93.6 and 18.8, respectively) were performed across 453 U.S. sites. Annualized TAVR and MTEER volumes were moderately correlated (r = 0.48; P < 0.001). After adjustment, 14.3% of sites had the same decile rank for TAVR and MTEER 30-day composite outcome, 50.6% were within 2 decile ranks; 35% had more discordant outcomes for the 2 procedures (P = 0.0005). For MTEER procedures, the median OR for the 30-day composite outcome was 1.57 (95% CI: 1.51-1.64), indicating a 57% variability in outcome by site. CONCLUSIONS: There is modest correlation between hospital-level volumes for TAVR and MTEER but low interprocedural correlation of outcomes. For similar patients, site-level variability for mortality/morbidity following MTEER was high. Factors influencing outcomes and "centers of excellence" as a whole may differ for TAVR and MTEER.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Sistema de Registros , Hospitales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
13.
Ann Thorac Surg ; 118(2): 430-438, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38286202

RESUMEN

BACKGROUND: The management of aortic stenosis has evolved to stratification by age as reflected in recent societal guidelines. We evaluated age-stratified surgical aortic valve replacement (SAVR) trends and outcomes in patients with bicuspid aortic valve (BAV) or tricuspid aortic valve (TAV) from The Society of Thoracic Surgeons Adult Cardiac Surgery Database. METHODS: This cohort included adults (≥18 years) undergoing SAVR for severe aortic stenosis between July 2011 and December 2022. Comparisons were stratified by age (<65 years, 65-79 years, ≥80 years) and BAV or TAV status. Primary end points included operative mortality, composite morbidity and mortality, and permanent stroke. Observed to expected ratios by The Society of Thoracic Surgeons predicted risk of mortality were calculated. RESULTS: In total, 200,849 SAVR patients (55,326 BAV [27.5%], 145,526 TAV [72.5%]) from 1238 participating hospitals met study criteria. Annual SAVR volumes decreased by 45% (19,560 to 10,851) during the study period. The decrease was greatest (96%) for patients ≥80 years of age (4914 to 207). The relative prevalence of BAV was greater in younger patients (<65 years, 69,068 [49.5% BAV]; 65-79 years, 104,382 [19.1% BAV]; ≥80 years, 27,399 [4.5% BAV]). The observed mortality in <80-year-old BAV patients (<65 years, 1.08; 65-79 years, 1.21; ≥80 years, 3.68) was better than the expected mortality rate (<65 years, 1.22; 65-79 years, 1.54; ≥80 years, 3.14). CONCLUSIONS: SAVR volume in the transcatheter era has decreased substantially, particularly for patients ≥80 years old and for those with TAV. Younger patients with BAV have better than expected outcomes, which should be carefully considered during shared decision-making in the treatment of aortic stenosis. SAVR should remain the preferred therapy in this population.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Anciano , Masculino , Femenino , Anciano de 80 o más Años , Factores de Edad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Estudios Retrospectivos , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología
14.
Struct Heart ; 8(1): 100215, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38283569
15.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38276658

RESUMEN

(1) Background: This study examines frailty's impact on proximal aortic surgery outcomes. (2) Methods: All patients with a thoracic aortic aneurysm who underwent aortic root, ascending aorta, or arch surgery from the 2016-2017 National Inpatient Sample were included. Frailty was defined by the Adjusted Clinical Groups Frailty Indicator. Outcomes of interest included in-hospital mortality and a composite of death, stroke, acute kidney injury (AKI), and major bleeding (MACE). (3) Results: Among 5745 patients, 405 (7.0%) met frailty criteria. Frail patients were older, with higher rates of chronic pulmonary disease, diabetes, and chronic kidney disease. There was no difference in in-hospital death (4.9% vs. 2.4%, p = 0.169); however, the frail group exhibited higher rates of stroke and AKI. Frail patients had a longer length of stay (17 vs. 8 days), and higher rates of non-home discharge (74.1% vs. 54.3%) than non-frail patients (both p < 0.001). Sensitivity analysis confirmed increased morbidity and mortality in frail individuals. After adjusting for patient comorbidities and hospital characteristics, frailty independently predicted MACE (OR 4.29 [1.88-9.78], p = 0.001), while age alone did not (OR 1.00 [0.99-1.02], p = 0.568). Urban teaching center status predicted a lower risk of MACE (OR 0.27 [0.08-0.94], p = 0.039). (4) Conclusions: Frailty is associated with increased morbidity in proximal aortic surgery and is a more significant predictor of mortality than age. Coordinated treatment in urban institutions may enhance outcomes for this high-risk group.

16.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38224255

RESUMEN

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Remoción de Dispositivos , Catéteres , Válvulas Cardíacas , Sistema de Registros
17.
Ann Thorac Surg ; 117(4): 761-768, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37031768

RESUMEN

BACKGROUND: Substantial socioeconomics-based disparities exist in cardiac surgery. Although there are robust data for revascularization and valve procedures, the effect of race and socioeconomic status on proximal aortic surgery is not well studied. This study analyzed the impact of race and socioeconomic status on in-hospital outcomes after proximal aortic surgery. METHODS: All adult patients who underwent proximal aortic surgery for aortic dissection or thoracic aneurysm from the 2016 to 2018 National Inpatient Sample were included. Primary outcomes included in-hospital mortality and in-hospital composite morbidity (stroke, pulmonary embolus, major bleeding, acute kidney injury, or permanent pacemaker insertion). Adjusted outcomes were assessed with multivariable analysis. RESULTS: A weighted total of 32,895 patients were included; 25,461 (77.4%) classified as White, 3224 (9.8%) Black, 2039 (6.2%) Hispanic, and 2171 (6.6%) other. Black and Hispanic patients had significantly lower median household income, higher proportion of self-pay insurance status, younger age, higher comorbidity burden, and a higher proportion of urgent or emergency procedures compared with White patients. There was no significant difference in observed in-hospital mortality by patient race, but non-White patients had significantly higher composite morbidity. On adjusted analysis, there was no difference in in-hospital mortality, but non-White race was an independent predictor of in-hospital morbidity (adjusted odds ratio, 1.6; 95% CI, 1.4-1.8; P < .001). CONCLUSIONS: Patients of non-White race who undergo proximal aortic surgery have less insurance coverage, more urgent procedures, and a higher comorbidity burden than White patients, disparities that translate to significantly higher morbidity in non-White. A greater focus on nonfatal outcome differentials and improving access to care likely will improve aortic surgery disparities.


Asunto(s)
Aneurisma de la Aorta Torácica , Disparidades Socioeconómicas en Salud , Adulto , Humanos , Estados Unidos/epidemiología , Factores de Riesgo , Hispánicos o Latinos , Renta , Aneurisma de la Aorta Torácica/cirugía , Disparidades en Atención de Salud , Estudios Retrospectivos
18.
Clin Res Cardiol ; 113(1): 48-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37138103

RESUMEN

BACKGROUND: Transaxillary (TAx) transcatheter aortic valve implantation (TAVI) is a preferred alternative access in patients ineligible for transfemoral TAVI. AIMS: This study used the Trans-AXillary Intervention (TAXI) registry to compare procedural success according to different types of transcatheter heart valves (THV). METHODS: For the TAXI registry anonymized data of patients treated with TAx-TAVI were collected from 18 centers. Acute procedural, early and 1-month clinical outcomes were adjudicated in accordance with standardized VARC-3 definitions. RESULTS: From 432 patients, 368 patients (85.3%, SE group) received self-expanding (SE) THV and 64 patients (14.8%, BE group) received balloon-expandable (BE) THV. Imaging revealed lower axillary artery diameters in the SE group (max/min diameter in mm: 8.4/6.6 vs 9.4/6.8 mm; p < 0.001/p = 0.04) but a higher proportion of axillary tortuosity in BE group (62/368, 23.6% vs 26/64, 42.6%; p = 0.004) with steeper aorta-left ventricle (LV) inflow (55° vs 51°; p = 0.002) and left ventricular outflow tract (LVOT)-LV inflow angles (40.0° vs 24.5°; 0.002). TAx-TAVI was more often conducted by right sided axillary artery in the BE group (33/368, 9.0% vs 17/64, 26.6%; p < 0.001). Device success was higher in the SE group (317/368, 86.1% vs 44/64, 68.8%, p = 0.0015). In logistic regression analysis, BE THV were a risk factor for vascular complications and axillary stent implantation. CONCLUSIONS: Both, SE and BE THV can be safely used in TAx-TAVI. However, SE THV were more often used and were associated with a higher rate of device success. While SE THV were associated with lower rates of vascular complications, BE THV were more often used in cases with challenging anatomical circumstances.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Sistema de Registros , Diseño de Prótesis
19.
Ann Surg ; 279(5): 891-899, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-37753657

RESUMEN

OBJECTIVE: To associate surgeon-anesthesiologist team familiarity (TF) with cardiac surgery outcomes. BACKGROUND: TF, a measure of repeated team member collaborations, has been associated with improved operative efficiency; however, examination of its relationship to clinical outcomes has been limited. METHODS: This retrospective cohort study included Medicare beneficiaries undergoing coronary artery bypass grafting (CABG), surgical aortic valve replacement (SAVR), or both (CABG+SAVR) between January 1, 2017, and September 30, 2018. TF was defined as the number of shared procedures between the cardiac surgeon and anesthesiologist within 6 months of each operation. Primary outcomes were 30- and 90-day mortality, composite morbidity, and 30-day mortality or composite morbidity, assessed before and after risk adjustment using multivariable logistic regression. RESULTS: The cohort included 113,020 patients (84,397 CABG; 15,939 SAVR; 12,684 CABG+SAVR). Surgeon-anesthesiologist dyads in the highest [31631 patients, TF median (interquartile range)=8 (6, 11)] and lowest [44,307 patients, TF=0 (0, 1)] TF terciles were termed familiar and unfamiliar, respectively. The rates of observed outcomes were lower among familiar versus unfamiliar teams: 30-day mortality (2.8% vs 3.1%, P =0.001), 90-day mortality (4.2% vs 4.5%, P =0.023), composite morbidity (57.4% vs 60.6%, P <0.001), and 30-day mortality or composite morbidity (57.9% vs 61.1%, P <0.001). Familiar teams had lower overall risk-adjusted odds of 30-day mortality or composite morbidity [adjusted odds ratio (aOR) 0.894 (0.868, 0.922), P <0.001], and for SAVR significantly lower 30-day mortality [aOR 0.724 (0.547, 0.959), P =0.024], 90-day mortality [aOR 0.779 (0.620, 0.978), P =0.031], and 30-day mortality or composite morbidity [aOR 0.856 (0.791, 0.927), P <0.001]. CONCLUSIONS: Given its relationship with improved 30-day cardiac surgical outcomes, increasing TF should be considered among strategies to advance patient outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Medicare , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA