Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Phys Imaging Radiat Oncol ; 27: 100474, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37560512

RESUMEN

Inter- and intra-fractional prostate motion can deteriorate the dose distribution in extremely hypofractionated intensity-modulated proton therapy. We used verification CTs and prostate motion data calculated from 1024 intra-fractional prostate motion records to develop a voxel-wise based 4-dimensional method, which had a time resolution of 1 s, to assess the dose impact of prostate motion. An example of 100 fractional simulations revealed that motion had minimal impact on planning dose, the accumulated dose in 95 % of the scenarios fulfilled the clinical goals for target coverage (D95 > 37.5 Gy). This method can serve as a complementary measure in clinical setting to guarantee plan quality.

2.
J Biomed Opt ; 27(6)2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35726130

RESUMEN

SIGNIFICANCE: Bioluminescence imaging and tomography (BLT) are used to study biologically relevant activity, typically within a mouse model. A major limitation is that the underlying optical properties of the volume are unknown, leading to the use of a "best" estimate approach often compromising quantitative accuracy. AIM: An optimization algorithm is presented that localizes the spatial distribution of bioluminescence by simultaneously recovering the optical properties and location of bioluminescence source from the same set of surface measurements. APPROACH: Measured data, using implanted self-illuminating sources as well as an orthotopic glioblastoma mouse model, are employed to recover three-dimensional spatial distribution of the bioluminescence source using a multi-parameter optimization algorithm. RESULTS: The proposed algorithm is able to recover the size and location of the bioluminescence source while accounting for tissue attenuation. Localization accuracies of <1 mm are obtained in all cases, which is similar if not better than current "gold standard" methods that predict optical properties using a different imaging modality. CONCLUSIONS: Application of this approach, using in-vivo experimental data has shown that quantitative BLT is possible without the need for any prior knowledge about optical parameters, paving the way toward quantitative molecular imaging of exogenous and indigenous biological tumor functionality.


Asunto(s)
Mediciones Luminiscentes , Tomografía Óptica , Algoritmos , Animales , Mediciones Luminiscentes/métodos , Ratones , Fantasmas de Imagen , Tomografía/métodos , Tomografía Óptica/métodos , Tomografía Computarizada por Rayos X/métodos
3.
Adv Radiat Oncol ; 6(2): 100655, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33732963

RESUMEN

PURPOSE: In patients undergoing stereotactic body radiation therapy (SBRT) for pancreatic adenocarcinoma, the reproducibility of tumor positioning between deep-inspiration breath holds is unclear. We characterized this variation with fiducials at simulation and treatment and investigated whether a patient-specific breath-hold (PSBH) margin would help account for intrafraction variation at treatment. METHODS AND MATERIALS: We analyzed 20 consecutive patients with pancreatic cancer who underwent SBRT with deep-inspiration breath holds. At simulation, 3 additional breath-hold scans were acquired immediately after the contrast-enhanced planning computed tomography (CT) scan and used to quantify the mean and maximum variations in the simulation fiducial position (Sim_Var avg and Sim_Var max ), as well as to design the internal target volume (ITV) incorporating a PSBH margin. RESULTS: At treatment, a mean of 5 breath-hold cone beam CT (CBCT) scans were acquired per fraction for each patient to quantify the mean and maximum variations in the treatment fiducial position (Tx_Var avg and Tx_Var max ). Various planning target volume (PTV) margins on the gross tumor volume (GTV) versus ITV were evaluated using CBCT scans, with the goal of >95% of fiducials being covered at treatment. The Sim_Var avg and Sim_Var max were 0.9 ± 0.5 mm and 1.5 ± 0.8 mm in the left-right (LR) direction, 0.9 ± 0.4 mm and 1.4 ± 0.4 mm in the anteroposterior (AP) direction, and 1.5 ± 0.9 mm and 2.1 ± 1.0 mm in the superoinferior (SI) direction, respectively. The Tx_Var avg and Tx_Var max were 1.2 ± 0.4 mm and 2.0 ± 0.7 mm in the LR direction, 1.1 ± 0.4 mm and 1.8 ± 0.6 mm in the AP direction, and 1.9 ± 1.0 mm and 3.1 ± 1.4 mm in the SI direction, respectively. The ITV was increased by 21.0% ± 8.6% compared with the GTV alone. The PTV margin necessary to encompass >95% of the fiducial locations was 2 mm versus 4 mm in both LR and AP and 4 mm versus 6 mm in SI for the ITV and the GTV, respectively. CONCLUSIONS: The interbreath-hold variation is not insignificant, especially in the SI direction. Acquiring multiple breath-hold CT scans at simulation can help quantify the reproducibility of the interbreath hold and design a PSBH margin for treatment.

4.
Adv Radiat Oncol ; 5(2): 260-268, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32280826

RESUMEN

PURPOSE: Stereotactic ablative radiation therapy (SABR) for oligometastatic prostate cancer (OMPC) may improve clinical outcomes, but current challenges in intrafraction tracking of multiple small targets limits treatment accuracy. A biology-guided radiation therapy (BgRT) delivery system incorporating positron emission tomography (PET) detectors is being developed to use radiotracer uptake as a biologic fiducial for intrafraction tumor tracking to improve geometric accuracy. This study simulates prostate-specific membrane antigen (PSMA)-directed BgRT using a cohort from our phase II randomized trial of SABR in men with recurrent hormone sensitive OMPC and compares dose distributions to clinical SABR (CSABR). METHODS AND MATERIALS: A research treatment planning system (RTPS) was used to replan 15 patients imaged with PSMA-targeted 18F-DCFPyL PET/computed tomography and previously treated with CSABR using conventional linear accelerators (linacs). The RTPS models a prototype ring-mounted linac incorporating PET and kilo-voltage computed tomography imaging subsystems and can be used to optimize BgRT plans, as well as research SABR (RSABR) plans, which use the prototype linac without radiotracer guidance. CSABR, RSABR, and BgRT plans were compared in terms of maximum planning target volume (PTV) dose (Dmax), mean dose to proximal organs at risk (DOAR), conformity index, as well as voxel-wise correlation of dose with PET specific uptake values to investigate possible dose-painting effects. RESULTS: RSABR and BgRT plans resulted in mean ± standard deviation increases in Dmax of 4 ± 11% (P = .21) and 18 ± 15% (P < .001) and reductions in DOAR of -20 ± 19% (P <.001) and -10 ± 19% (P = .02) compared with CSABR. Similar target coverage was maintained with conformity indices of 0.81 ± 0.04 (P < .001) and 0.72 ± 0.08 (P = .44) for RSABR and BgRT compared with 0.74 ± 0.08 for CSABR. Dose and log (specific uptake values) had Pearson correlation coefficients of 0.10 (CSABR), 0.16 (RSABR), and 0.31 (BgRT). CONCLUSIONS: BgRT plans provided similar PTV coverage and conformity compared with CSABR while incorporating underlying PET activity. These results demonstrate feasibility of BgRT optimization enabling online PSMA-targeted, PET-based tracked dose delivery for OMPC.

5.
Pract Radiat Oncol ; 9(6): e591-e598, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31252089

RESUMEN

PURPOSE: Nonhomogeneous dose optimization (NHDO) is exploited in stereotactic body radiation therapy (SBRT) to increase dose delivery to the tumor and allow rapid dose falloff to surrounding normal tissues. We investigate changes in plan quality when NHDO is applied to inverse-planned conventionally fractionated radiation therapy (CF-RT) plans in patients with non-small cell lung cancer. METHODS AND MATERIALS: Patients with near-central non-small cell lung cancer treated with CF-RT in 2018 at a single institution were identified. CF-RT plans were replanned using NHDO techniques, including normalizing to a lower isodose line, while maintaining clinically acceptable normal tissue constraints and target coverage. Tumor control probabilities were calculated. We compared delivered CF-RT plans using homogenous dose optimization (HDO) versus NHDO using Wilcoxon signed-rank tests. Median values are reported. RESULTS: Thirteen patients were replanned with NHDO techniques. Planning target volume coverage by the prescription dose was similar (NHDO = 96% vs HDO = 97%, P = .3). All normal-tissue dose constraints were met. NHDO plans were prescribed to a lower-prescription isodose line compared with HDO plans (85% vs 97%, P = .001). NHDO increased mean dose to the planning target volume (73 Gy vs 67 Gy), dose heterogeneity, and dose falloff gradient (P < .03). NHDO decreased mean dose to surrounding lungs, esophagus, and heart (relative reduction of 6%, 14%, and 15%, respectively; P < .05). Other normal tissue objectives improved with NHDO, including total lung V40 and V60, heart V30, and maximum esophageal dose (P < .05). Tumor control probabilities doubled from 31.6% to 65.4% with NHDO (P = .001). CONCLUSIONS: In select patients, NHDO principles used in SBRT optimization can be applied to CF-RT. NHDO results in increased tumor dose, reduction in select organ-at-risk dose objectives, and better maintenance of target coverage and normal-tissue constraints compared with HDO. Our data demonstrate that principles of NHDO used in SBRT can also improve plan quality in CF-RT.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Dosificación Radioterapéutica , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA