1.
Radiography (Lond) ; 28(2): 433-439, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34716089

RESUMEN

INTRODUCTION: While tin prefiltration is established in various CT applications, its value in extremity cone-beam CT relative to optimized spectra has not been thoroughly assessed thus far. This study aims to investigate the effect of tin filters in extremity cone-beam CT with a twin-robotic X-ray system. METHODS: Wrist, elbow and ankle joints of two cadaveric specimens were examined in a laboratory setup with different combinations of prefiltration (copper, tin), tube voltage and current-time product. Image quality was assessed subjectively by five radiologists with Fleiss' kappa being computed to measure interrater agreement. To provide a semiquantitative criterion for image quality, contrast-to-noise ratios (CNR) were compared for standardized regions of interest. Volume CT dose indices were calculated for a 16 cm polymethylmethacrylate phantom. RESULTS: Radiation dose ranged from 17.4 mGy in the clinical standard protocol without tin filter to as low as 0.7 mGy with tin prefiltration. Image quality ratings and CNR for tin-filtered scans with 100 kV were lower than for 80 kV studies with copper prefiltration despite higher dose (11.2 and 5.6 vs. 4.5 mGy; p < 0.001). No difference was ascertained between 100 kV scans with tin filtration and 60 kV copper-filtered scans with 75% dose reduction (subjective: p = 0.101; CNR: p = 0.706). Fleiss' kappa of 0.597 (95% confidence interval 0.567-0.626; p < 0.001) indicated moderate interrater agreement. CONCLUSION: Considerable dose reduction is feasible with tin prefiltration, however, the twin-robotic X-ray system's low-dose potential for extremity 3D imaging is maximized with a dedicated low-kilovolt scan protocol in situations without extensive beam-hardening artifacts. IMPLICATIONS FOR PRACTICE: Low-kilovolt imaging with copper prefiltration provides a superior trade-off between dose reduction and image quality compared to tin-filtered cone-beam CT scan protocols with higher tube voltage.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Estaño , Tomografía Computarizada de Haz Cónico/métodos , Cobre , Extremidades , Humanos , Dosis de Radiación , Rayos X
2.
AJNR Am J Neuroradiol ; 38(12): 2257-2263, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28982793

RESUMEN

BACKGROUND AND PURPOSE: Photon-counting detectors offer the potential for improved image quality for brain CT but have not yet been evaluated in vivo. The purpose of this study was to compare photon-counting detector CT with conventional energy-integrating detector CT for human brains. MATERIALS AND METHODS: Radiation dose-matched energy-integrating detector and photon-counting detector head CT scans were acquired with standardized protocols (tube voltage/current, 120 kV(peak)/370 mAs) in both an anthropomorphic head phantom and 21 human asymptomatic volunteers (mean age, 58.9 ± 8.5 years). Photon-counting detector thresholds were 22 and 52 keV (low-energy bin, 22-52 keV; high-energy bin, 52-120 keV). Image noise, gray matter, and white matter signal-to-noise ratios and GM-WM contrast and contrast-to-noise ratios were measured. Image quality was scored by 2 neuroradiologists blinded to the CT detector type. Reproducibility was assessed with the intraclass correlation coefficient. Energy-integrating detector and photon-counting detector CT images were compared using a paired t test and the Wilcoxon signed rank test. RESULTS: Photon-counting detector CT images received higher reader scores for GM-WM differentiation with lower image noise (all P < .001). Intrareader and interreader reproducibility was excellent (intraclass correlation coefficient, ≥0.86 and 0.79, respectively). Quantitative analysis showed 12.8%-20.6% less image noise for photon-counting detector CT. The SNR of photon-counting detector CT was 19.0%-20.0% higher than of energy-integrating detector CT for GM and WM. The contrast-to-noise ratio of photon-counting detector CT was 15.7% higher for GM-WM contrast and 33.3% higher for GM-WM contrast-to-noise ratio. CONCLUSIONS: Photon-counting detector brain CT scans demonstrated greater gray-white matter contrast compared with conventional CT. This was due to both higher soft-tissue contrast and lower image noise for photon-counting CT.


Asunto(s)
Encéfalo/diagnóstico por imagen , Neuroimagen/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Fotones , Reproducibilidad de los Resultados , Relación Señal-Ruido
3.
Artículo en Inglés | MEDLINE | ID: mdl-28943700

RESUMEN

This study evaluates the capabilities of a whole-body photon counting CT system to differentiate between four common kidney stone materials, namely uric acid (UA), calcium oxalate monohydrate (COM), cystine (CYS),and apatite (APA) ex vivo. Two different x-ray spectra (120 kV and 140 kV) were applied and two acquisition modes were investigated; The macro-mode generates two energy threshold based image-volumes and two energy bin based image-volumes. In the chesspattern-mode, however, four energy thresholds are applied. A virtual low energy image, as well as a virtual high energy image are derived from initial threshold-based images, while considering their statistically correlated nature. The energy bin based images of the macro-mode, as well as the virtual low and high energy image of the chesspattern-mode serve as input for our dual energy evaluation. The dual energy ratio of the individually segmented kidney stones were utilized to quantify the discriminability of the different materials. The dual energy ratios of the two acquisition modes showed high correlation for both applied spectra. Wilcoxon-rank sum tests and the evaluation of the area under the receiver operating characteristics curves suggest that the UA kidney stones are best differentiable from all other materials (AUC = 1.0), followed by CYS (AUC ≈ 0.9 compared against COM and APA). COM and APA, however, are hardly distinguishable (AUC between 0.63 and 0.76). The results hold true for the measurements of both spectra and both acquisition modes.

4.
Proc SPIE Int Soc Opt Eng ; 101322017 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-28458443

RESUMEN

In addition to the standard-resolution (SR) acquisition mode, a high-resolution (HR) mode is available on a research photon-counting-detector (PCD) whole-body CT system. In the HR mode each detector consists of a 2x2 array of 0.225 mm × 0.225 mm subpixel elements. This is in contrast to the SR mode that consists of a 4x4 array of the same sub-elements, and results in 0.25 mm isotropic resolution at iso-center for the HR mode. In this study, we quantified ex vivo the capabilities of the HR mode to characterize renal stones in terms of morphology and mineral composition. Forty pure stones - 10 uric acid (UA), 10 cystine (CYS), 10 calcium oxalate monohydrate (COM) and 10 apatite (APA) - and 14 mixed stones were placed in a 20 cm water phantom and scanned in HR mode, at radiation dose matched to that of routine dual-energy stone exams. Data from micro CT provided a reference for the quantification of morphology and mineral composition of the mixed stones. The area under the ROC curve was 1.0 for discriminating UA from CYS, 0.89 for CYS vs COM and 0.84 for COM vs APA. The root mean square error (RMSE) of the percent UA in mixed stones was 11.0% with a medium-sharp kernel and 15.6% with the sharpest kernel. The HR showed qualitatively accurate characterization of stone morphology relative to micro CT.

5.
Proc SPIE Int Soc Opt Eng ; 101322017 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-28392613

RESUMEN

A new ultra high-resolution (UHR) mode has been implemented on a whole body photon counting-detector (PCD) CT system. The UHR mode has a pixel size of 0.25 mm by 0.25 mm at the iso-center, while the conventional (macro) mode is limited to 0.5 mm by 0.5 mm. A set of synthetic lung nodules (two shapes, five sizes, and two radio-densities) was scanned using both the UHR and macro modes and reconstructed with 2 reconstruction kernels (4 sets of images in total). Linear regression analysis was performed to compare measured nodule volumes from CT images to reference volumes. Surface curvature was calculated for each nodule and the full width half maximum (FWHM) of the curvature histogram was used as a shape index to differentiate sphere and star shape nodules. Receiver operating characteristic (ROC) analysis was performed and area under the ROC curve (AUC) was used as a figure of merit for the differentiation task. Results showed strong linear relationship between measured nodule volume and reference standard for both UHR and macro mode. For all nodules, volume estimation was more accurate using UHR mode with sharp kernel (S80f), with lower mean absolute percent error (MAPE) (6.5%) compared with macro mode (11.1% to 12.9%). The improvement of volume measurement from UHR mode was more evident particularly for small nodule size (3mm, 5mm), or star-shape nodules. Images from UHR mode with sharp kernel (S80f) consistently demonstrated the best performance (AUC = 0.85) when separating star from sphere shape nodules among all acquisition and reconstruction modes. Our results showed the advantages of UHR mode on a PCD CT scanner in lung nodule characterization. Various clinical applications, including quantitative imaging, can benefit substantially from this high resolution mode.

6.
Proc SPIE Int Soc Opt Eng ; 101322017 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-28392615

RESUMEN

Two ultra-high-resolution (UHR) imaging modes, each with two energy thresholds, were implemented on a research, whole-body photon-counting-detector (PCD) CT scanner, referred to as sharp and UHR, respectively. The UHR mode has a pixel size of 0.25 mm at iso-center for both energy thresholds, with a collimation of 32 × 0.25 mm. The sharp mode has a 0.25 mm pixel for the low-energy threshold and 0.5 mm for the high-energy threshold, with a collimation of 48 × 0.25 mm. Kidney stones with mixed mineral composition and lung nodules with different shapes were scanned using both modes, and with the standard imaging mode, referred to as macro mode (0.5 mm pixel and 32 × 0.5 mm collimation). Evaluation and comparison of the three modes focused on the ability to accurately delineate anatomic structures using the high-spatial resolution capability and the ability to quantify stone composition using the multi-energy capability. The low-energy threshold images of the sharp and UHR modes showed better shape and texture information due to the achieved higher spatial resolution, although noise was also higher. No noticeable benefit was shown in multi-energy analysis using UHR compared to standard resolution (macro mode) when standard doses were used. This was due to excessive noise in the higher resolution images. However, UHR scans at higher dose showed improvement in multi-energy analysis over macro mode with regular dose. To fully take advantage of the higher spatial resolution in multi-energy analysis, either increased radiation dose, or application of noise reduction techniques, is needed.

7.
Artículo en Inglés | MEDLINE | ID: mdl-27330238

RESUMEN

A high-resolution (HR) data collection mode has been introduced to the whole-body, research photon-counting-detector CT system installed in our laboratory. In this mode, 64 rows of 0.45 mm × 0.45 mm detectors pixels were used, which corresponded to a pixel size of 0.225 mm × 0.225 mm at the iso-center. Spatial resolution of this HR mode was quantified by measuring the MTF from a scan of a 50 micron wire phantom. An anthropomorphic lung phantom, cadaveric swine lung, temporal bone and heart specimens were scanned using the HR mode, and image quality was subjectively assessed by two experienced radiologists. Comparison of the HR mode images against their energy integrating system (EID) equivalents using comb filters was also performed. High spatial resolution of the HR mode was evidenced by the MTF measurement, with 15 lp/cm and 20 lp/cm at 10% and 2% MTF. Images from anthropomorphic phantom and cadaveric specimens showed clear delineation of small structures, such as lung vessels, lung nodules, temporal bone structures, and coronary arteries. Temporal bone images showed critical anatomy (i.e. stapes superstructure) that was clearly visible in the PCD system but hardly visible with the EID system. These results demonstrated the potential application of this imaging mode in lung, temporal bone, and vascular imaging. Other clinical applications that require high spatial resolution, such as musculoskeletal imaging, may also benefit from this high resolution mode.

9.
Diabet Med ; 23(2): 156-63, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16433713

RESUMEN

AIMS: The hypothesis was tested in an exploratory study that individuals at high risk of developing Type 1 diabetes mellitus have altered systemic levels of cytokines and chemokines. SUBJECTS AND METHODS: Forty-two non-diabetic first-degree relatives of patients with Type 1 diabetes mellitus were recruited. Of these, 18 had multiple islet autoantibodies (islet cell antibody, glutamic acid decarboxylase antibody, IA-2 antibody). Follow-up for 9-11 years confirmed high vs. moderate diabetes risk in islet autoantibody-positive vs. -negative relatives. Cytokines and chemokines were determined by enzyme-linked immunosorbent assay (ELISA). RESULTS: Serum concentrations of classic Th1-associated cytokines (IFN-gamma, IL-12, IL-18) or Th2/Treg-associated cytokines (IL-5, IL-10, IL-13) did not significantly differ in high vs. moderate diabetes risk group. However, of six chemokines analysed, levels of CCL3 and CCL4 were increased (P = 0.0442 and P = 0.0334) while CCL2 was decreased (P = 0.0318) in the multiple islet autoantibody-positive group. No significant differences were seen for CCL5, CCL11, CXCL10. There was a significant correlation between the two closely related chemokines CCL3 and CCL4 in individuals at risk (r = 0.84, P = 0.00005), but not in the autoantibody-negative group. CONCLUSION: Relatives at high risk of developing Type 1 diabetes mellitus have abnormal cellular immune regulation at the level of systemic chemokines. The up-regulation of CCL3 and CCL4 vs. down-regulation of CCL2 suggests opposed functions of these chemokines in the disease process. These findings need to be confirmed by independent studies.


Asunto(s)
Quimiocinas/sangre , Citocinas/sangre , Diabetes Mellitus Tipo 1/sangre , Autoanticuerpos/análisis , Quimiocina CCL2/sangre , Quimiocina CCL3 , Quimiocina CCL4 , Quimiocinas CC/sangre , Estudios de Cohortes , Diabetes Mellitus Tipo 1/inmunología , Humanos , Interferón gamma/sangre , Interleucina-10/sangre , Interleucina-12/sangre , Interleucina-13/sangre , Interleucina-18/sangre , Interleucina-5/sangre , Islotes Pancreáticos/química , Proteínas Inflamatorias de Macrófagos/sangre , Factores de Riesgo
10.
J Trace Elem Med Biol ; 14(3): 179-83, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11130856

RESUMEN

The important role of selenium in the mammalian organism has been manifested by the detection of several selenoenzymes, and there are still numerous selenium-containing proteins to be identified. After in vivo labeling of rats with [75Se]-selenite, gel electrophoretic separation of the proteins in tissue homogenates and autoradiography of the labeled bands, information on the selenium-containing proteins present in the different tissues was obtained. In the separation by SDS-PAGE and two-dimensional IEF/SDS-PAGE a large number of selenium-containing proteins or protein subunits with apparent molecular masses in the range from 116 to 8 kDa could be distinguished. This range was extended by applying a modified Tricine-SDS-PAGE, which allows the determination of smaller proteins. Using this method in the separation of the homogenates of the adrenal, brain, diaphragm, epididymis, heart, kidney, liver, lung, pituitary, prostate, skeletal muscle, spleen, thymus and thyroid, four additional selenium-containing proteins with molecular masses of approximately 7 kDa, 5kDa, 4 kDa and 3kDa were detected. The 5 kDa protein and the 7 kDa protein were identified as selenocysteine-containing selenoproteins.


Asunto(s)
Glicina/análogos & derivados , Proteínas/análisis , Animales , Cromatografía Líquida de Alta Presión , Electroforesis en Gel Bidimensional/métodos , Electroforesis en Gel de Poliacrilamida/métodos , Focalización Isoeléctrica/métodos , Masculino , Peso Molecular , Proteínas/aislamiento & purificación , Ratas , Ratas Wistar , Selenio/análisis , Radioisótopos de Selenio/análisis , Selenoproteínas , Dodecil Sulfato de Sodio , Distribución Tisular
11.
Phys Rev Lett ; 74(2): 212-215, 1995 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-10058331