Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Interv Cardiol ; 2023: 8907315, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38125031

RESUMEN

Objectives: The aim of this postmarket clinical study was to assess the safety and efficacy of the latest generation polymer-free sirolimus-eluting stents (PF-SES) in an all-comers population comparing outcomes in stable coronary artery disease (CAD) versus acute coronary syndrome (ACS) in France. Background: The efficacy and safety of the first-generation PF-SES have already been demonstrated by randomized controlled trials and "all-comers" observational studies. Methods: For this all-comers observational, prospective, multicenter study, 1456 patients were recruited in 22 French centers. The primary endpoint was target lesion revascularization (TLR) rate at 12 months and secondary endpoints included major adverse cardiac events (MACE) and bleeding. Results: 895 patients had stable CAD and 561 had ACS. At 12 months, 2% of patients had a TLR, with similar rates between stable CAD and ACS (1.9% vs 2.2%, p = 0.7). The overall MACE rate was 5.2% with an expected higher rate in patients with ACS as compared to those with stable CAD (7.3% vs 3.9%, p = 0.007). The overall bleeding event rate was 4.5%, with similar rates in stable CAD as compared to ACS patients (3.8% vs 5.6%, p = 0.3). Dual antiplatelet therapy (DAPT) interruptions prior to the recommended duration occurred in 41.7% of patients with no increase in MACE rates as compared to patients who did not prematurely interrupt DAPT (3.9% vs 6.1%, p = 0.073). Conclusions: The latest generation PF-SES is associated with low clinical event rates in these all-comers patients. There was a high rate of prematurely terminated DAPT, without any effect on MACE at 12 months. This trial is registered with NCT03809715.


Asunto(s)
Síndrome Coronario Agudo , Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Sirolimus , Humanos , Síndrome Coronario Agudo/cirugía , Síndrome Coronario Agudo/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos/efectos adversos , Hemorragia/inducido químicamente , Hospitales , Polímeros , Estudios Prospectivos , Sirolimus/efectos adversos , Resultado del Tratamiento , Terapia Antiplaquetaria Doble
2.
Arch Cardiovasc Dis ; 116(12): 590-596, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37891058

RESUMEN

Vasospastic angina, also described as Prinzmetal angina, was first described as a variant form of angina at rest with transient ST-segment elevation; it is common and present in many clinical scenarios, including chronic and acute coronary syndromes, sudden cardiac death, arrhythmia and syncope. However, vasospastic angina remains underdiagnosed, and provocative tests are rarely performed. The gold-standard diagnostic approach uses invasive coronary angiography to induce coronary spasm using ergonovine, methylergonovine or acetylcholine as provocative stimuli. The lack of uniform protocol decreases the use and performance of these tests, accounting for vasospastic angina underestimation. This position paper from the French Coronary Atheroma and Interventional Cardiology Group (GACI) aims to review the indications for provocative tests, the testing conditions, drug protocols and positivity criteria.


Asunto(s)
Angina Pectoris Variable , Cardiología , Enfermedad de la Arteria Coronaria , Vasoespasmo Coronario , Placa Aterosclerótica , Humanos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasoespasmo Coronario/diagnóstico , Vasoespasmo Coronario/diagnóstico por imagen , Espasmo
3.
Catheter Cardiovasc Interv ; 101(1): 60-71, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378683

RESUMEN

BACKGROUND: The polymer-free biolimus coated stent (BioFreedom) was shown to be superior to bare metal stents in the LEADERS FREE randomized trial in high bleeding risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT). However, there is limited outcome data with this device in an all-comers' population. METHODS: We conducted a prospective single-arm study of patients undergoing percutaneous coronary intervention with the polymer-free biolimus coated stent in 25 centers in France with wide inclusion criteria including multivessel disease, complex lesions, and acute coronary syndromes. The primary endpoint was the incidence of target lesion failure (TLF), a composite of cardiac death or target-vessel myocardial infarction (MI) or clinically indicated target lesion revascularization (ci-TLR) at 1-year. The patient population was classified according to the presence (or not) of HBR criteria according to the recent ARC-HBR definition. RESULTS: Between April 2019 and April 2020, 1497 patients were enrolled. TLF occurred in 101 (6.9%) patients, including cardiac death in 35 (2.4%), target vessel MI in 20 (1.4%) and ci-TLR in 65 (4.5%) of them. There were 491 HBR patients (32.8%) and 1006 non-HBR patients. The median duration of DAPT was 74 days in the HBR group versus 348 days in the non-HBR group (p < 0.0001). TLF occurred in 44 (9.2%) of the HBR group and in 57 (5.8%) of the non-HBR group (relative risk 1.62 [95% confidence interval: 1.10-2.41], p = 0015). Compared to the non-HBR group, HBR patients had higher rates of cardiac death (4.4% vs. 1.4%, p = 0.0005) and target vessel MI (2.9% vs. 0.6%, p = 0.0003), but similar rates of ci-TLR. BARC 3-5 bleeding occurred in 6.2% of the HBR group versus 1.4% of the non-HBR group (p < 0.0001). CONCLUSION: In this multicenter all-comers study, HBR patients treated with a polymer-free biolimus coated stent had, compared to non-HBR patients, an increased risk of cardiac death and MI, and despite a shorter duration of DAPT, continued to have higher rates of BARC 3-5 bleeding.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Inhibidores de Agregación Plaquetaria/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Stents Liberadores de Fármacos/efectos adversos , Sirolimus/efectos adversos , Diseño de Prótesis , Resultado del Tratamiento , Stents/efectos adversos , Infarto del Miocardio/etiología , Hemorragia/inducido químicamente , Francia , Muerte
4.
J Invasive Cardiol ; 31(4): 94-100, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30927531

RESUMEN

BACKGROUND: Prolonged dual-antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients undergoing percutaneous coronary intervention can be challenging. We assessed the clinical safety of bare-metal stent (BMS) implantation followed by drug-coated balloon (DCB) treatment in HBR patients for whom drug-eluting stent implantation could be problematic in maintaining low ischemic event rate without increasing hemorrhagic events. METHODS: The study included patients with at least 1 de novo lesion who were either under long-term anticoagulant treatment or required semi-urgent non-coronary intervention. The strategy consisted of PRO-Kinetic Energy BMS stent (Biotronik AG) implantation followed by Pantera Lux DCB (Biotronik AG) and patients were followed for up to 12 months in 37 French centers. RESULTS: Between October 2013 and April 2015, a total of 432 patients with 623 de novo lesions who were either under long-term anticoagulant treatment (n = 300) or required semi-urgent non-cardiac surgery (n = 132) were treated by BMS plus DCB. Mean patient age was 74.1 ± 9.1 years, 76.4% were men, and 38% were diabetic. The composite primary endpoint rate (defined as target-lesion failure at 12 months) was 5.6% (95% confidence interval, 3.3-7.9). Median duration for DAPT treatment was 33 days. Hemorrhagic events, as defined by the Bleeding Academic Research Consortium, occurred in 31 patients (7.2%) and definite stent thrombosis occurred in 5 patients (1.3%). CONCLUSIONS: The combination of BMS plus DCB intervention is safe even with a short duration of DAPT. This strategy might be an alternative to DES implantation in HBR patients if future randomized trials support this approach.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Hemorragia/prevención & control , Paclitaxel/uso terapéutico , Intervención Coronaria Percutánea , Inhibidores de Agregación Plaquetaria/efectos adversos , Anciano , Anciano de 80 o más Años , Antineoplásicos Fitogénicos/uso terapéutico , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Progresión de la Enfermedad , Francia , Hemorragia/inducido químicamente , Humanos , Masculino , Evaluación de Resultado en la Atención de Salud , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Diseño de Prótesis , Ajuste de Riesgo/métodos , Tiempo
5.
Catheter Cardiovasc Interv ; 90(6): 890-897, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28544186

RESUMEN

OBJECTIVES: The French Ebiomatrix registry aimed to confirm the results of the Leaders trial in an all-comer population in France. BACKGROUND: The Leaders trial showed the Biolimus-eluting-sent (BES) to be equivalent to the Cypher stent in terms of safety and efficacy at 1 year and superior regarding stent thrombosis after 1 year. METHODS: BES recipients were enrolled in 42 French centers with up to 24-month clinical follow up. RESULTS: 2365 patients were included. Mean age: 65.7 ±11.2 years, 76.1% males, 31.8% had diabetes, 36.5% ACS (28.7% non-ST-elevation MI and 7.8% with ST-elevation MI). 1.7 ± 1.0 stents/patient were implanted and procedural success was 99.5%. 12-month follow-up was completed in 94.3% patients and 24 months in 91.4%. MACCE rates at 12 and 24 months were 5.8% and 9% (all cause-death 1.5% and 2.2%; stent thrombosis definite/probable 0.4% and 0.6%), respectively. MACCE were not significantly higher in diabetic patients compared with non-diabetics but cardiac death was higher (1.6% vs. 0.6%, P = 0.01 at 1 year and 1.9% vs. 0.6, P = 0.005 at 2 years) as was stent thrombosis (0.9% vs. 0.2%, P = 0.009 and 1.2 vs. 0.3% P = 0.008). Compared with non-ACS patients, MACCE was significantly higher in the ACS subgroup (7.5% vs. 4.8%, P = 0.001 at 1 year and 10.3% vs.8.1%, P = 0.07 at 2 years). CONCLUSION: In this large real-world registry, the BES with biodegradable polymer showed excellent acute and mid-term outcomes with a 5.8% and 9% rate of MACCE at one and 2 years and a very low rate of stent thrombosis between 1 and 2 years (0.2%), thus demonstrating the replicability of the LEADERS trial in a registry population. © 2017 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
7.
Arch Cardiovasc Dis ; 105(2): 60-7, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22424323

RESUMEN

BACKGROUND: Coronary stents have evolved over time, from bare-metal stents to drug-eluting stents, and now to bioactive stents. AIMS: We sought to explore the immediate outcome of the titanium-nitride-oxide-coated bioactive stent, Titan2(®), in real-world practice, and the incidence of major cardiac events at follow-up. METHODS: Consecutive patients admitted for percutaneous intervention for at least one significant (≥50%) lesion in a native coronary artery were treated with Titan2(®) stent implantation. The primary endpoint was total major adverse cardiac events at 12-month follow-up. Secondary endpoints included target lesion revascularization at 12-month follow-up and the duration of dual antiplatelet therapy. RESULTS: Among 356 patients (mean age 67.4 ± 12.1 years), 77.2% were male and 39.3% were treated for myocardial infarction (MI). A total of 546 Titan2(®) stents were implanted in 420 lesions. Angiographic and clinical procedural success was achieved in all cases. No cases of in-hospital major adverse cardiac events or acute stent thrombosis were reported. Of 335 patients (94.1%) with 12-month clinical follow-up, four (1.2%) died, MI occurred in five (1.5%), target lesion revascularization was performed in 17 (5.1%) and major adverse cardiac events occurred in 24 (7.2%). One patient (0.3%) suffered late stent thrombosis during follow-up, but no cases of acute or subacute stent thrombosis occurred. Dual antiplatelet therapy continued beyond 6 months in 64.5% of patients. CONCLUSIONS: In real-world practice, Titan2(®) stent implantation achieves an excellent immediate outcome, with a low incidence of major adverse cardiac events at 12-month follow-up.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Materiales Biocompatibles Revestidos , Estenosis Coronaria/terapia , Infarto del Miocardio/terapia , Stents , Titanio , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Quimioterapia Combinada , Femenino , Francia , Agencias Gubernamentales , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA