Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38817687

RESUMEN

Objective: A newly launched endoscopy system (EVIS X1, CV-1500; Olympus) is equipped with texture and color enhancement imaging (TXI). We aimed to investigate the efficacy of TXI for the visibility and diagnostic accuracy of non-polypoid colorectal lesions. Methods: We examined 100 non-polypoid lesions in 42 patients from the same position, angle, and distance of the view in three modes: white light imaging (WLI), narrow-band imaging (NBI), and TXI. The primary outcome was to compare polyp visibility in the three modes using subjective polyp visibility score and objective color difference values. The secondary outcome was to compare the diagnostic accuracy without magnification. Results: Overall, the visibility score of TXI was significantly higher than that of WLI (3.7 ± 1.1 vs. 3.6 ± 1.1; p = 0.008) and lower than that of NBI (3.7 ± 1.1 vs. 3.8 ± 1.1; p = 0.013). Color difference values of TXI were higher than those of WLI (11.5 ± 6.9 vs. 9.1 ± 5.4; p < 0.001) and lower than those of NBI (11.5 ± 6.9 vs. 13.1 ± 7.7; p = 0.002). No significant differences in TXI and NBI (visibility score: 3.7 ± 1.0 vs. 3.8 ± 1.1; p = 0.833, color difference values: 11.6 ± 7.1 vs. 12.9 ± 8.3; p = 0.099) were observed for neoplastic lesions. Moreover, the diagnostic accuracy of TXI was significantly higher than that of NBI (65.5% vs. 57.6%, p = 0.012) for neoplastic lesions. Conclusions: TXI demonstrated higher visibility than that of WLI and lower than that of NBI. Further investigations are warranted to validate the performance of the TXI mode comprehensively.

2.
Endosc Ultrasound ; 13(1): 28-34, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38947114

RESUMEN

Background and Objectives: Endoscopic treatment of obstructive jaundice and pancreatitis due to hepaticojejunostomy (H-J), pancreatojejunostomy (P-J) strictures, and tumor recurrence after pancreatoduodenectomy (PD) is technically challenging. Treatment of P-J strictures results in poor outcomes. Although conventional EUS that has an oblique view is not suitable for such patients, forward-viewing EUS (FV-EUS) may become a useful option. This study aimed to evaluate the feasibility and efficacy of FV-EUS in patients who have undergone PD. Methods: Patients with PD who were scheduled to undergo diagnosis and treatment using FV-EUS for H-J or P-J lesions were enrolled in this single-center prospective study. After observation of the P-J and H-J using FV-EUS according to a predetermined protocol, treatment using FV-EUS was performed as needed. Results: A total of 30 patients were enrolled, and FV-EUS was used to observe P-J and H-J in 24 and 28 patients, respectively. The detection rates of P-J and H-J by endoscopy were 50% (12/24) and 96.4% (27/28), respectively, and by EUS were 70.8% (17/24) and 100% (28/28), respectively. Of these, P-J and H-J were found by endoscopy only after EUS observation in 3 and 1 patient, respectively. The success rates of endoscopic treatment using FV-EUS were 66.7% (2/3), 95.2% (20/21), and 25% (1/4) for benign P-J strictures, benign H-J strictures, and tumor recurrence, respectively. Conclusions: Endoscopic treatment using FV-EUS is feasible and effective for patients after PD. Moreover, FV-EUS increases the P-J lesion detection rate by adding EUS observation.

4.
J Gastroenterol Hepatol ; 39(8): 1571-1579, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38646886

RESUMEN

BACKGROUND AND AIM: Tip-in endoscopic mucosal resection (EMR) has a high en bloc resection rate for large colorectal neoplasms. However, non-experts' performance in Tip-in EMR has not been investigated. We investigated whether Tip-in EMR can be achieved effectively and safely even by non-experts. METHODS: This retrospective study included consecutive patients who underwent Tip-in EMR for 15-25 mm colorectal nonpedunculated neoplasms at a Japanese tertiary cancer center between January 2014 and December 2020. Baseline characteristics, treatment outcomes, learning curve of non-experts, and risk factors of failing self-achieved en bloc resection were analyzed. RESULTS: A total of 597 lesions were analyzed (438 by experts and 159 by non-experts). The self-achieved en bloc resection (69.8% vs 88.6%, P < 0.001) and self-achieved R0 resection (58.3% vs 76.5%, P < 0.001) rates were significantly lower in non-experts with <10 cases of experience than in experts, but not in non-experts with >10 cases. Adverse event (P = 0.165) and local recurrence (P = 0.892) rates were not significantly different between experts and non-experts. Risk factors of failing self-achieved en bloc resection were non-polypoid morphology (OR 3.4, 95% CI 1.6-7.3, P = 0.001), lesions with an underlying semilunar fold (OR 3.6, 95% CI 1.6-7.3, P < 0.001), positive non-lifting sign (OR 3.1, 95% CI 1.2-8.0, P = 0.023), and non-experts with an experience of ≤10 cases (OR 3.6, 95% CI 2.1-6.3, P < 0.001). CONCLUSION: The clinical outcomes of Tip-in EMR for 15-25 mm lesions performed by non-experts were favorable.


Asunto(s)
Neoplasias Colorrectales , Resección Endoscópica de la Mucosa , Curva de Aprendizaje , Humanos , Resección Endoscópica de la Mucosa/métodos , Resección Endoscópica de la Mucosa/educación , Resección Endoscópica de la Mucosa/efectos adversos , Masculino , Estudios Retrospectivos , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Femenino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Factores de Riesgo , Competencia Clínica , Recurrencia Local de Neoplasia
6.
J Gastroenterol Hepatol ; 39(5): 927-934, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38273460

RESUMEN

BACKGROUND AND AIM: Computer-aided detection (CADe) systems can efficiently detect polyps during colonoscopy. However, false-positive (FP) activation is a major limitation of CADe. We aimed to compare the rate and causes of FP using CADe before and after an update designed to reduce FP. METHODS: We analyzed CADe-assisted colonoscopy videos recorded between July 2022 and October 2022. The number and causes of FPs and excessive time spent by the endoscopist on FP (ET) were compared pre- and post-update using 1:1 propensity score matching. RESULTS: During the study period, 191 colonoscopy videos (94 and 97 in the pre- and post-update groups, respectively) were recorded. Propensity score matching resulted in 146 videos (73 in each group). The mean number of FPs and median ET per colonoscopy were significantly lower in the post-update group than those in the pre-update group (4.2 ± 3.7 vs 18.1 ± 11.1; P < 0.001 and 0 vs 16 s; P < 0.001, respectively). Mucosal tags, bubbles, and folds had the strongest association with decreased FP post-update (pre-update vs post-update: 4.3 ± 3.6 vs 0.4 ± 0.8, 0.32 ± 0.70 vs 0.04 ± 0.20, and 8.6 ± 6.7 vs 1.6 ± 1.7, respectively). There was no significant decrease in the true positive rate (post-update vs pre-update: 95.0% vs 99.2%; P = 0.09) or the adenoma detection rate (post-update vs pre-update: 52.1% vs 49.3%; P = 0.87). CONCLUSIONS: The updated CADe can reduce FP without impairing polyp detection. A reduction in FP may help relieve the burden on endoscopists.


Asunto(s)
Pólipos del Colon , Colonoscopía , Diagnóstico por Computador , Humanos , Colonoscopía/métodos , Diagnóstico por Computador/métodos , Reacciones Falso Positivas , Masculino , Femenino , Persona de Mediana Edad , Pólipos del Colon/diagnóstico , Pólipos del Colon/diagnóstico por imagen , Anciano , Grabación en Video , Puntaje de Propensión , Factores de Tiempo
7.
J Gastroenterol Hepatol ; 39(4): 667-673, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38149747

RESUMEN

BACKGROUND AND AIM: Hot snare polypectomy using blend or coagulation current is widely used; however, it causes deeper tissue heat injury, leading to adverse events. We hypothesized that hot polypectomy using low-power pure cut current (PureCut, effect 1 10 W) could reduce deeper tissue heat injury. We conducted animal experiments to evaluate the deeper tissue heat injury and conducted a prospective clinical study to examine its cutting ability. METHODS: In a porcine rectum, hot polypectomy using Blend current (EndoCut, effect 3 40 W) and low-power pure cut current was performed. The deepest part of heat destruction and thickness of the non-burned submucosal layer were evaluated histologically. Based on the results, we performed low-power pure cut current hot polypectomy for 10-14 mm adenoma. The primary endpoint was complete resection defined as one-piece resection with negative for adenoma in quadrant biopsies from the defect margin. RESULTS: In experiments, all low-power pure-cut resections were limited within the submucosal layer whereas blend current resections coagulated the muscular layer in 13% (3/23). The remaining submucosal layer was thicker in low-power pure cut current than in blend current resections. In the clinical study, low-power pure-cut hot polypectomy removed all 100 enrolled polyps. For 98 pathologically neoplastic polyps, complete resection was achieved in 84 (85.7%, 95% confidence interval, 77-92%). The lower limit of the 95% confidence interval was not more than 15% below the pre-defined threshold of 86.6%. No severe adverse events occurred. CONCLUSIONS: A novel low-power pure-cut hot polypectomy may be feasible for adenoma measuring 10-14 mm. (UMIN000037678).


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/cirugía , Pólipos del Colon/patología , Colonoscopía/métodos , Estudios Prospectivos , Estudios de Factibilidad , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Adenoma/cirugía , Adenoma/patología
8.
J Gastroenterol Hepatol ; 38(10): 1802-1807, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37519057

RESUMEN

BACKGROUND AND AIM: It is unclear whether additional treatment should be considered given the recurrence risk after endoscopic submucosal dissection (ESD) for esophageal squamous cell carcinoma (ESCC) when the vertical margin is positive or unclear (VM1/VMX) due to intralesional damage. This study aimed to elucidate the local recurrence risk of ESCC caused by intralesional damage during ESD. METHODS: Among consecutive patients with pT1a ESCCs initially treated by ESD at our institution between January 2006 and December 2018, ESCCs diagnosed as VM1/VMX were retrospectively reviewed. Exclusion criteria were piecemeal resection and any additional treatment after ESD. Intralesional damage included the following three types: a macroscopic hole inside the lesion, an incision from the lateral margin of the specimen into the lesion, and crushing injury or burn effect into the deepest area of the lesion without an obvious hole. The local recurrence rate after ESD was primarily analyzed. RESULTS: Of 1174 pT1a ESCCs initially treated using ESD, 22 lesions were histopathologically diagnosed as VM1/VMX due to intralesional damage (1.9%; 95% confidence interval [CI], 1.2-2.8%). At a median follow-up period of 60.0 (interquartile range, 15.0-84.0) months, no local recurrence was observed (0.0%; 95% CI, 0.0-13.3%) among 21 lesions finally evaluated. CONCLUSIONS: The impact of intralesional damage during ESD for ESCC on local recurrence might be negligible. Follow-up without additional treatment may be acceptable even if intralesional damage occurs and results in VM1/VMX after ESD for pT1a ESCCs.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Esofágicas , Carcinoma de Células Escamosas de Esófago , Humanos , Carcinoma de Células Escamosas de Esófago/cirugía , Carcinoma de Células Escamosas de Esófago/etiología , Neoplasias Esofágicas/patología , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , Estudios Retrospectivos , Recurrencia Local de Neoplasia/patología , Resultado del Tratamiento
9.
J Gastroenterol Hepatol ; 38(10): 1794-1801, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37495215

RESUMEN

BACKGROUND AND AIM: Optimal tumor samples are crucial for successful analysis using commercially available comprehensive genomic profiling (CACGP). However, samples acquired by endoscopic ultrasound-guided tissue acquisition (EUS-TA) are occasionally insufficient, and no consensus on the optimal number of needle passes required for CACGP exists. This study aimed to explore the optimal number of needle passes required for EUS-TA to procure an ideal sample fulfilling the prerequisite criteria of CACGPs. METHODS: Patients who underwent EUS-TA for solid masses between November 2019 and July 2021 were retrospectively studied. The correlation between the acquisition rate of an ideal sample and the number of needle passes mounted on a microscope slide was evaluated. Additionally, the factors predicting a successful analysis were investigated in patients scheduled for CACGP using EUS-TA-obtained samples during the same period. RESULTS: EUS-TAs using 22- and 19-gauge (G) needles were performed in 336 and 57 patients, respectively. There was a positive correlation between the acquisition rate and the number of passes using a 22-G needle (38.9%, 45.0%, 83.7%, and 100% for 1, 2, 3, and 4 passes, respectively), while no correlation was found with a 19-G needle (84.2%, 83.3%, and 85.0% for 1, 2, and 3 passes, respectively). The analysis success rate in patients with scheduled CACGP was significantly higher with ideal samples than with suboptimal samples (94.1% vs 55.0%, P < 0.01). CONCLUSIONS: The optimal estimated number of needle passes was 4 and 1-2 for 22- and 19-G needles, respectively.


Asunto(s)
Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico , Neoplasias Pancreáticas , Humanos , Estudios Retrospectivos , Endosonografía , Agujas , Neoplasias Pancreáticas/patología , Páncreas/diagnóstico por imagen
11.
Gastric Cancer ; 26(6): 988-1001, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37368170

RESUMEN

BACKGROUND: This study aimed to evaluate the risk factors for developing metachronous primary Gastric Cancer (GC) after Endoscopic Resection (ER) for esophageal Squamous Cell Carcinoma (SCC). METHODS: We studied 283 patients with esophageal SCC who underwent ER. The study outcomes were as follows: (1) incidence of metachronous primary GC after ER; and (2) predictors for the development of metachronous primary GC after ER by the Cox proportional hazards model. RESULTS: The median follow-up was 43.1 months (1.81-79.1), and the 3-year cumulative incidence of metachronous primary GC was 6.5% (95%CI: 4.1-10.4). The incidence of metachronous primary GC during the follow-up period was 2.31 per 100 person-years. The frequencies of severe gastric atrophy and macrocytosis at the timing of ER were significantly higher in patients with than without metachronous primary GC (91.7% vs. 73.2%, p = 0.0422, 20.8% vs. 5.2%, p = 0.0046, respectively). Severe gastric atrophy was associated with the development of metachronous primary GC (sex-and-age adjusted hazard ratio (HR) [95%CI] = 4.12 [0.95-27.78], p = 0.0093). Macrocytosis was associated with the development of metachronous primary GC (sex-and-age adjusted HR = 4.76 [1.75-13.0], p = 0.0012) and found to be an independent predictor for metachronous primary GC by multivariate Cox proportional hazards analysis (HR [95%CI] = 4.35 [1.60-11.84], p = 0.004). CONCLUSIONS: Severe gastric atrophy and macrocytosis should be noted in the development of metachronous primary GC after ER for esophageal SCC. In particular, macrocytosis at the timing of ER was considered an important predictor. CLINICAL TRIALS REGISTRY NUMBER: UMIN000001676.


Asunto(s)
Neoplasias Esofágicas , Carcinoma de Células Escamosas de Esófago , Gastritis Atrófica , Neoplasias Primarias Secundarias , Neoplasias Gástricas , Humanos , Carcinoma de Células Escamosas de Esófago/cirugía , Neoplasias Esofágicas/patología , Neoplasias Gástricas/patología , Neoplasias Primarias Secundarias/epidemiología , Neoplasias Primarias Secundarias/etiología , Factores de Riesgo , Gastritis Atrófica/complicaciones , Atrofia , Estudios Retrospectivos
12.
Life (Basel) ; 13(3)2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36983866

RESUMEN

Underwater endoscopic mucosal resection (UEMR) has become a popular endoscopic resection method for large colorectal neoplasms. However, visualization can be poor during UEMR due to the presence of intestinal fluid. Gel immersion endoscopic mucosal resection (GIEMR), using a specially developed gel (Viscoclear®, Otsuka Pharmaceutical Factory, Tokushima, Japan), can improve the visual field. However, reports of GIEMR for colorectal polyps are limited. Herein, we evaluated the short-term outcomes of GIEMR for non-pedunculated colorectal neoplasms (NPCRN). This single-center, retrospective, and observational study includes 25 lesions in 20 patients with NPCRN who underwent GIEMR between January and October 2022. The short-term outcomes and adverse events were evaluated. The lesion locations were as follows: right colon, 18 lesions; left colon, 7 lesions; and rectum, none. The median tumor diameter was 15 (IQR, 10-18) mm. Histological classification was as follows: sessile serrated lesion, 9 cases; adenoma, 12 cases; and intramucosal adenocarcinoma, 4 cases. The overall en bloc resection rates and R0 resection rates were 80% (20/25) and 72% (18/25). For NPCRN in 10-19 mm, the en bloc resection rate was 75% (12/16), with an R0 resection rate of 69% (11/16). No post-polypectomy bleeding, perforation, or post-coagulation syndrome were observed. The findings of our study provide preliminary evidence of the efficacy and safety of GIEMR for NPCRN. Therefore, GIEMR may be a promising novel endoscopic resection method for NPCRN.

14.
Gastrointest Endosc ; 98(5): 735-743.e2, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36849058

RESUMEN

BACKGROUND AND AIMS: Because endoscopic submucosal dissection (ESD) for early gastric cancer (EGC) preserves the entire stomach, missed gastric cancers (MGCs) are often found in the remaining gastric mucosa. However, the endoscopic causes of MGCs remain unclear. Therefore, we aimed to elucidate the endoscopic causes and characteristics of MGCs after ESD. METHODS: From January 2009 to December 2018, all patients undergoing ESD for initially detected EGC were enrolled. According to a review of EGD images before ESD, we identified the endoscopic causes (perceptual, exposure, sampling errors, and inadequate preparation) and characteristics of MGC in each endoscopic cause. RESULTS: Of 2208 patients who underwent ESD for initial EGC, 82 patients (3.7%) had 100 MGCs. The breakdown of endoscopic causes of MGCs was as follows: 69 (69%) perceptual errors, 23 (23%) exposure errors, 7 (7%) sampling errors, and 1 (1%) inadequate preparation. Logistic regression analysis showed that the risk factors for perceptual error were male sex (odds ratio [OR], 2.45; 95% confidence interval [CI], 1.16-5.18), isochromatic coloration (OR, 3.17; 95% CI, 1.47-6.84), greater curvature (OR, 2.31; 95% CI, 1.121-4.40), and lesion size ≤12 mm (OR, 1.74; 95% CI, 1.07-2.84). The sites of exposure errors were around the incisura angularis (11 [48%]), posterior wall of the gastric body (6 [26%]), and antrum (5 [21%]). CONCLUSIONS: We identified MGCs in 4 categories and clarified their characteristics. Quality improvements in EGD observation, with attention to the risks of perceptual and site of exposure errors, can potentially prevent missing EGCs.


Asunto(s)
Resección Endoscópica de la Mucosa , Neoplasias Gástricas , Humanos , Masculino , Femenino , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Gastroscopía/métodos , Resección Endoscópica de la Mucosa/efectos adversos , Resección Endoscópica de la Mucosa/métodos , Estudios Retrospectivos , Mucosa Gástrica/cirugía , Mucosa Gástrica/patología , Resultado del Tratamiento
16.
Scand J Gastroenterol ; 58(6): 700-708, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36573487

RESUMEN

OBJECTIVES: Extension of adenocarcinoma of the esophagogastric junction under the squamous epithelium may lead to errors when determining lateral margins. However, the characteristics of subsquamous extension are unclear. Herein, we evaluated the prevalence and characteristics of subsquamous extension of adenocarcinoma of the esophagogastric junction and the diagnostic performance of endoscopy for this condition. METHODS: Eighty-nine consecutive patients with superficial adenocarcinoma of the esophagogastric junction who underwent endoscopic or surgical resection at a tertiary cancer center between January 2010 and December 2017 were retrospectively evaluated. Endoscopic subsquamous extension was defined as a submucosal tumor-like elevation covered by squamous epithelium and/or a brownish area with abnormal microvessels on the squamous epithelium observed using narrow-band imaging. The diagnostic performance of endoscopy for subsquamous extension was evaluated using histological subsquamous extension as gold standard. RESULTS: Thirty-nine patients (44%) had histological subsquamous extension. Proton pump inhibitor use was significantly associated with histological subsquamous extension [odds ratio: 4.65; 95% confidence interval (CI): 1.77-12.2]. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of endoscopic subsquamous extension were 56% (95% CI: 40-72%), 96% (86-99%), 92% (73-99%), 74% (62-84%) and 79% (69-87%), respectively. The median length difference between histological and endoscopic subsquamous extension was 2 mm (range: -6 to 9 mm). CONCLUSIONS: The sensitivity of endoscopic diagnosis of subsquamous extension was unsatisfactory. The endoscopic length of subsquamous extension tended to be underestimated. An oral safety margin of one centimeter is reasonable during endoscopic resection of adenocarcinoma of the esophagogastric junction.IMPACT STATEMENT This study will contribute significantly to the literature because this is the first study to determine the difference between the lengths of subsquamous extension detected endoscopically and histologically. This study determines the prevalence of subsquamous extension and identifies characteristics associated with subsquamous extension. An understanding of the risk of subsquamous extension is important when choosing a treatment strategy and planning the resection margins in patients with adenocarcinoma of the esophagogastric junction. This study provides patients with subsquamous extension characteristics and suggests a method for accurately diagnosing this condition.


Asunto(s)
Adenocarcinoma , Esófago de Barrett , Carcinoma de Células Escamosas , Neoplasias Esofágicas , Humanos , Esófago de Barrett/diagnóstico , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/cirugía , Estudios Retrospectivos , Esofagoscopía/métodos , Adenocarcinoma/diagnóstico por imagen , Adenocarcinoma/cirugía , Unión Esofagogástrica/patología , Carcinoma de Células Escamosas/patología
18.
Scand J Gastroenterol ; 58(4): 422-428, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36250663

RESUMEN

OBJECTIVES: Colonoscopy with adenomatous polypectomy reduces the incidence and mortality of colorectal cancer. We introduced a strategy of removing all neoplastic polyps in single-session out-patient colonoscopy using cold polypectomy. We aimed to investigate the achievement of single-session complete removal rate of detected colorectal polyps in clinical practice. MATERIALS AND METHODS: This retrospective study included colonoscopy-scheduled 40-79-year-old outpatients, with at least one colorectal neoplasm, between January 2015 and December 2016. Exclusion criteria were: colorectal neoplasms 21 mm or larger in size; pre-examination for colorectal surgery or endoscopic submucosal dissection; colonoscopy performed by health check program; ongoing antithrombotic treatment; inflammatory bowel disease; familial adenomatous polyposis. We defined 'clean colon' as the removal of all detected neoplastic polyps in a single-session colonoscopy. We evaluated clean colon rate, factors relating to clean colon failure and complications. RESULTS: We evaluated 2527 patients (mean age 68 years; 799 women) with 8203 colorectal polyps (7675 adenomas, 423 serrated lesions, 105 Tis and T1 cancers). In 1-4 mm polyps, cold snare polypectomy (CSP; 51.8%) and cold forceps polypectomy (CFP; 45.8%) were applied. Clean colon rates were 95.1% per patient and 97.1% per lesion. The significant factors denoting clean colon failure were inadequate bowel preparation, ≥5 lesions, and the most advanced estimated histology of adenocarcinoma, on multivariate analyses. Post-polypectomy bleeding requiring endoscopic hemostasis occurred in five patients (0.2%) who had undergone endoscopic mucosal resection (EMR) or hot snare polypectomy (HSP). Perforation occurred in one patient (0.04%) with EMR. CONCLUSIONS: The clean colon rates were satisfactory in single-session out-patient colonoscopy using cold polypectomy.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Humanos , Femenino , Anciano , Adulto , Persona de Mediana Edad , Pólipos del Colon/cirugía , Pólipos del Colon/patología , Colonoscopía , Pacientes Ambulatorios , Estudios Retrospectivos , Neoplasias Colorrectales/cirugía , Neoplasias Colorrectales/patología , Adenoma/cirugía
19.
Gastrointest Endosc ; 97(2): 232-240.e4, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36228694

RESUMEN

BACKGROUND AND AIMS: Our aim was to elucidate the clinical outcomes of endoscopic submucosal dissection (ESD) for superficial circumferential esophageal squamous cell carcinoma (cESCC). METHODS: Consecutive patients who underwent ESD for cESCC between 2009 and 2020 were retrospectively reviewed. Short-term outcomes were en-bloc resection, R0 resection, procedure time, and adverse events, whereas long-term outcomes were overall survival (OS), disease-specific survival (DSS), cumulative recurrence rate (CRR), and clinical course. RESULTS: Fifty-two patients with 52 cESCCs (median tumor length, 5.0 cm; interquartile range [IQR], 4.0-6.3) were evaluated. The en-bloc resection and R0 resection rates were 100% (95% confidence interval [CI], 94.4-100) and 69.2% (95% CI, 54.9-81.3), respectively. The median procedure time was 112 minutes (IQR, 87-162). Intraoperative perforations and delayed bleeding occurred in 4 (7.7%) and 1 (1.9%) patients, respectively. Among the 42 patients who underwent ESD alone, 36 (85.7%) experienced esophageal strictures. Within a median follow-up of 49.1 months (IQR, 25.7-74.7), the 4-year OS, DSS, and CRR were 86.2% (95% CI, 71.6-93.6), 95.5% (95% CI, 83.1-98.9), and 11.5% (95% CI, 4.1-23.1), respectively. There was no significant difference in the OS between patients with low-risk cESCC (pT1a, negative lymphovascular invasion, and negative vertical margin) and high-risk lesions, regardless of undergoing additional treatment (P = .93). In 31 patients with low-risk cESCC who were treated with ESD alone, the 4-year OS, DSS, and CRR were 93.2%, 100%, and 0%, respectively. CONCLUSIONS: ESD is a highly curative treatment for cESCC with favorable long-term outcomes, especially in low-risk patients. Stricture-prevention techniques should be improved to optimize the benefits of ESD for cESCC.


Asunto(s)
Carcinoma de Células Escamosas , Resección Endoscópica de la Mucosa , Neoplasias Esofágicas , Carcinoma de Células Escamosas de Esófago , Humanos , Carcinoma de Células Escamosas de Esófago/cirugía , Neoplasias Esofágicas/patología , Resección Endoscópica de la Mucosa/métodos , Carcinoma de Células Escamosas/cirugía , Carcinoma de Células Escamosas/patología , Estudios Retrospectivos , Resultado del Tratamiento
20.
JAMA Netw Open ; 5(8): e2227667, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35984658

RESUMEN

Importance: Single endoscopic examination often misses early gastric cancer (GC), even when both high-definition white light imaging and narrow-band imaging are used. It is unknown whether new GC can be detected approximately 1 year after intensive index endoscopic examination. Objective: To examine whether new GC can be detected approximately 1 year after intensive index endoscopic examination using both white light and narrow-band imaging. Design, Setting, and Participants: This case-control study was a preplanned secondary analysis of a randomized clinical trial involving 4523 patients with a high risk of GC who were enrolled between October 1, 2014, and September 22, 2017. Data were analyzed from December 26, 2019, to April 21, 2021. Participants in the clinical trial received index endoscopy to detect early GC via 2 examinations of the entire stomach using white light and narrow-band imaging. The duration of follow-up was 15 months. The secondary analysis included 107 patients with newly detected GC (case group) and 107 matched patients without newly detected GC (control group) within 15 months after index endoscopy. Interventions: Surveillance endoscopy was scheduled between 9 and 15 months after index endoscopy. If new lesions suspected of being early GC were detected during surveillance endoscopy, biopsies were obtained to confirm the presence of cancer. Main Outcomes and Measures: The primary end point was the rate of new GC detected within 15 months after index endoscopy. The main secondary end point was identification of risk factors associated with new GC detected within 15 months after index endoscopy. Results: Among 4523 patients (mean [SD] age, 70.6 [7.5] years; 3527 men [78.0%]; all of Japanese ethnicity) enrolled in the clinical trial, 4472 received index endoscopy; the rate of early GC detected on index endoscopy was 3.0% (133 patients). Surveillance endoscopy was performed in 4146 of 4472 patients (92.7%) who received an index endoscopy; the rate of new GC detected within 15 months after index endoscopy was 2.6% (107 patients). Among 133 patients for whom early GC was detected during index endoscopy, 110 patients (82.7%) received surveillance endoscopy within 15 months after index endoscopy; the rate of newly detected GC was 10.9% (12 patients). For the secondary analysis of risk factors associated with newly detected GC, characteristics were well balanced between the 107 patients included in the case group vs the 107 patients included in the matched control group (mean [SD] age, 71.7 [7.2] years vs 71.8 [7.0] years; 94 men [87.9%] in each group; 82 patients [76.6%] vs 87 patients [81.3%] with a history of gastric neoplasm). Multivariate analysis revealed that the presence of open-type atrophic gastritis (odds ratio, 6.00; 95% CI, 2.25-16.01; P < .001) and early GC detection by index endoscopy (odds ratio, 4.67; 95% CI, 1.08-20.21; P = .04) were independent risk factors associated with new GC detection. Conclusions and Relevance: In this study, the rate of new GC detected by surveillance endoscopy approximately 1 year after index endoscopy was similar to that of early GC detected by index endoscopy. These findings suggest that 1-year surveillance is warranted for patients at high risk of GC.


Asunto(s)
Neoplasias Gástricas , Anciano , Estudios de Casos y Controles , Detección Precoz del Cáncer , Humanos , Japón/epidemiología , Masculino , Imagen de Banda Estrecha/métodos , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/epidemiología , Neoplasias Gástricas/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA