Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Transl Psychiatry ; 7(4): e1091, 2017 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-28398340

RESUMEN

Dopamine function is broadly implicated in multiple neuropsychiatric conditions believed to have a genetic basis. Although a few positron emission tomography (PET) studies have investigated the impact of single-nucleotide polymorphisms (SNPs) in the dopamine D2 receptor gene (DRD2) on D2/3 receptor availability (binding potential, BPND), these studies have often been limited by small sample size. Furthermore, the most commonly studied SNP in D2/3 BPND (Taq1A) is not located in the DRD2 gene itself, suggesting that its linkage with other DRD2 SNPs may explain previous PET findings. Here, in the largest PET genetic study to date (n=84), we tested for effects of the C957T and -141C Ins/Del SNPs (located within DRD2) as well as Taq1A on BPND of the high-affinity D2 receptor tracer 18F-Fallypride. In a whole-brain voxelwise analysis, we found a positive linear effect of C957T T allele status on striatal BPND bilaterally. The multilocus genetic scores containing C957T and one or both of the other SNPs produced qualitatively similar striatal results to C957T alone. The number of C957T T alleles predicted BPND in anatomically defined putamen and ventral striatum (but not caudate) regions of interest, suggesting some regional specificity of effects in the striatum. By contrast, no significant effects arose in cortical regions. Taken together, our data support the critical role of C957T in striatal D2/3 receptor availability. This work has implications for a number of psychiatric conditions in which dopamine signaling and variation in C957T status have been implicated, including schizophrenia and substance use disorders.


Asunto(s)
Alelos , Polimorfismo de Nucleótido Simple/genética , Putamen/metabolismo , Receptores de Dopamina D2/genética , Receptores de Dopamina D3/genética , Estriado Ventral/metabolismo , Adolescente , Adulto , Benzamidas , Dopamina/fisiología , Femenino , Radioisótopos de Flúor , Determinismo Genético , Ligamiento Genético , Genotipo , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Tomografía de Emisión de Positrones , Putamen/diagnóstico por imagen , Receptores de Dopamina D2/metabolismo , Transducción de Señal/genética , Estriado Ventral/diagnóstico por imagen , Adulto Joven
2.
Pediatr Radiol ; 31(12): 848-51, 2001 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-11727018

RESUMEN

Mycobacterium avium complex (MAC) is a rare cause of isolated intrathoracic disease in the immunocompetent child; delays in diagnosis and treatment are common. The current case is an 11-month-old girl with symptoms, signs, and radiographic findings of bronchial obstruction. Comparison of this case to the literature revealed that there is a characteristic presentation of intrathoracic MAC infection in immunocompetent children (children aged 3 years or less, without exposure to Mycobacterium tuberculosis, presenting with clinical and radiographic evidence of bronchial obstruction) that should increase our index of suspicion for this diagnosis. This is particularly important since M. tuberculosis can present in a similar pattern.


Asunto(s)
Pulmón/diagnóstico por imagen , Infección por Mycobacterium avium-intracellulare/diagnóstico por imagen , Broncografía , Diagnóstico Diferencial , Femenino , Humanos , Inmunocompetencia , Lactante , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Infección por Mycobacterium avium-intracellulare/diagnóstico , Atelectasia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X
3.
Seizure ; 8(7): 427-31, 1999 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10600585

RESUMEN

Two cases of patients with paraneoplastic limbic encephalitis, difficult to control seizures, and unilateral hippocampal hypermetabolism on positron emission tomography (PET) are described. Two women aged 33 and 61 presented with uncontrolled complex partial seizures, profound memory loss and cognitive decline. One was later diagnosed with breast cancer and the other with lung cancer. Video-EEG on the first patient recorded multifocal sharp waves and bilateral independent seizure onsets. The second patient had no epileptiform discharges and bitemporal ictal onset, even though the clinical seizures suggested a right temporal onset. Magnetic resonance imaging (MRI) was normal in both patients. PET scans obtained in the interictal state showed right hippocampal hypermetabolism in both patients. In the second patient, the lung cancer was irradiated with resolution of seizures and improvement of memory function. A PET scan six months later was normal. Subsequent seizure recurrence and worsening of memory led to the discovery of widespread metastases. Limbic encephalitis should be considered in the differential diagnosis of intractable partial epilepsy, particularly if accompanied by severe memory loss and cognitive decline. Treatment of the underlying cancer may be lead to improved seizure control. Hippocampal hypermetabolism may be a common feature on PET, and may indicate subclinical seizure activity.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encefalitis Límbica/diagnóstico , Tomografía Computarizada de Emisión , Adulto , Diagnóstico Diferencial , Electroencefalografía , Femenino , Humanos , Persona de Mediana Edad
4.
IEEE Trans Med Imaging ; 18(2): 144-50, 1999 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-10232671

RESUMEN

The primary objective of this study is to perform a blinded evaluation of two groups of retrospective image registration techniques, using as a gold standard a prospective marker-based registration method, and to compare the performance of one group with the other. These techniques have already been evaluated individually [27]. In this paper, however, we find that by grouping the techniques as volume based or surface based, we can make some interesting conclusions which were not visible in the earlier study. In order to ensure blindness, all retrospective registrations were performed by participants who had no knowledge of the gold-standard results until after their results had been submitted. Image volumes of three modalities: X-ray computed tomography (CT), magnetic resonance (MR), and positron emission tomography (PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/or from PET to MR. These investigators communicated their transformations, again via the Internet, to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOI's). Our results indicate that the volume-based techniques in this study tended to give substantially more accurate and reliable results than the surface-based ones for the CT-to-MR registration tasks, and slightly more accurate results for the PET-to-MR tasks. Analysis of these results revealed that the rotational component of error was more pronounced for the surface-based group. It was also apparent that all of the registration techniques we examined have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.


Asunto(s)
Cabeza , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Cabeza/diagnóstico por imagen , Cabeza/patología , Humanos , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía Computarizada de Emisión , Tomografía Computarizada por Rayos X
6.
J Comput Assist Tomogr ; 21(4): 554-66, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9216759

RESUMEN

PURPOSE: The primary objective of this study is to perform a blinded evaluation of a group of retrospective image registration techniques using as a gold standard a prospective, marker-based registration method. To ensure blindedness, all retrospective registrations were performed by participants who had no knowledge of the gold standard results until after their results had been submitted. A secondary goal of the project is to evaluate the importance of correcting geometrical distortion in MR images by comparing the retrospective registration error in the rectified images, i.e., those that have had the distortion correction applied, with that of the same images before rectification. METHOD: Image volumes of three modalities (CT, MR, and PET) were obtained from patients undergoing neurosurgery at Vanderbilt University Medical Center on whom bone-implanted fiducial markers were mounted. These volumes had all traces of the markers removed and were provided via the Internet to project collaborators outside Vanderbilt, who then performed retrospective registrations on the volumes, calculating transformations from CT to MR and/ or from PET to MR. These investigators communicated their transformations again via the Internet to Vanderbilt, where the accuracy of each registration was evaluated. In this evaluation, the accuracy is measured at multiple volumes of interest (VOIs), i.e., areas in the brain that would commonly be areas of neurological interest. A VOI is defined in the MR image and its centroid c is determined. Then, the prospective registration is used to obtain the corresponding point c' in CT or PET. To this point, the retrospective registration is then applied, producing c" in MR. Statistics are gathered on the target registration error (TRE), which is the distance between the original point c and its corresponding point c". RESULTS: This article presents statistics on the TRE calculated for each registration technique in this study and provides a brief description of each technique and an estimate of both preparation and execution time needed to perform the registration. CONCLUSION: Our results indicate that retrospective techniques have the potential to produce satisfactory results much of the time, but that visual inspection is necessary to guard against large errors.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Telerradiología/métodos , Tomografía Computarizada de Emisión/métodos , Tomografía Computarizada por Rayos X/métodos , Redes de Comunicación de Computadores , Errores Diagnósticos , Humanos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/normas , Imagen por Resonancia Magnética/estadística & datos numéricos , Variaciones Dependientes del Observador , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad , Telerradiología/normas , Telerradiología/estadística & datos numéricos , Tomografía Computarizada de Emisión/instrumentación , Tomografía Computarizada de Emisión/normas , Tomografía Computarizada de Emisión/estadística & datos numéricos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/normas , Tomografía Computarizada por Rayos X/estadística & datos numéricos
7.
Chest ; 110(1): 102-6, 1996 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-8681611

RESUMEN

STUDY OBJECTIVE: To determine the success and complication rates of fibrinolytic therapy (FL) in the treatment of thoracic empyema. DESIGN AND PATIENTS: Between December 1992 and November 1994, all patients referred with empyema thoracis (ET) were offered FL. FL consisted of streptokinase (275,000 +/- 170,000 IU) or urokinase (121,000 +/- 57,000 IU) daily for a mean of 6.2 +/- 2.1 days. SETTING: The University of New Mexico Health Sciences Center and the Albuquerque Veterans Affairs Medical Center. RESULTS: Twenty-six patients were treated. Sixty-two percent (16/26) had complete resolution (CR) of symptoms, near or complete normalization of chest radiographic findings, and required no surgery or empyema tubes. Eight percent (2/26) had relief of symptoms and partial resolution (PR) of radiographic abnormalities and were discharged from the hospital with empyema tubes in place. All patients with PR had empyema tubes removed within 30 days of hospital discharge. Thirty-one percent (8/26) of patients failed to completely improve clinically or radiographically (nonresponse) and were treated with decortication or empyema tubes for greater than 30 days. Bleeding occurred in a single patient (4%). There was no mortality associated with FL use. CONCLUSIONS: The use of FL is associated with resolution of ET in 69% (18/26) of patients. This modality is safe, effective, and spares most patients with empyema the morbidity and mortality of thoracotomy.


Asunto(s)
Empiema Pleural/tratamiento farmacológico , Terapia Trombolítica , Adulto , Tubos Torácicos , Empiema Pleural/diagnóstico por imagen , Empiema Pleural/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estreptoquinasa/uso terapéutico , Terapia Trombolítica/efectos adversos , Tomografía Computarizada por Rayos X , Activador de Plasminógeno de Tipo Uroquinasa/uso terapéutico
8.
J Comput Assist Tomogr ; 20(3): 482-3, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8626917

RESUMEN

We present a case of cardiac hemangioma in a symptomatic patient. MR and CT each have specific characteristics that should make one consider including or excluding this in the differential diagnosis of a cardiac tumor.


Asunto(s)
Neoplasias Cardíacas/diagnóstico , Hemangioma Cavernoso/diagnóstico , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Femenino , Neoplasias Cardíacas/diagnóstico por imagen , Hemangioma Cavernoso/diagnóstico por imagen , Humanos
9.
Invest Radiol ; 31(5): 261-6, 1996 May.
Artículo en Inglés | MEDLINE | ID: mdl-8724123

RESUMEN

RATIONAL AND OBJECTIVE: The purpose of this study is to evaluate the relation between a focus of temporal lobe hypometabolism, including comparison between mesial and lateral asymmetry on fluorine-18-labeled-deoxyglucose-positron emission tomography (18FDG-PET) and surgical outcome in patients with uncontrolled partial seizures. METHODS: Case histories, electroencephalogram (EEG) findings, radiographic findings, and surgical outcome (36 +/- 11 months of follow-up) were reviewed in 38 consecutive patients who had a interictal 18FDG-PET scan and subsequent temporal resection. RESULTS: Among the 36 patients who had a temporal lobe focus of hypometabolism (more than 15% asymmetry to contralateral side), 61% (22 of 36) became seizure-free, 33% (12 of 36) markedly improved and 6% (2 of 36) did not improve. The focus of hypometabolism on PET was in agreement with the epileptic focus on the noninvasive EEG in 30 of 36 patients and in 19 of the 22 patients who underwent an invasive EEG. The asymmetry index for the mesial temporal lobe was significantly higher in the group of patients who became seizure-free compared with the other patients. CONCLUSION: This study confirms that a focus of interictal temporal hypometabolism on PET is associated with marked improvement of seizure control after surgery in 94% (34 of 36) of the patients. Hypometabolism in the mesial temporal lobe appears to be associated with a seizure-free outcome.


Asunto(s)
Desoxiglucosa , Epilepsia Parcial Compleja/diagnóstico por imagen , Epilepsia del Lóbulo Temporal/diagnóstico por imagen , Radioisótopos de Flúor , Lóbulo Temporal/diagnóstico por imagen , Lóbulo Temporal/metabolismo , Tomografía Computarizada de Emisión/métodos , Adolescente , Adulto , Epilepsia Parcial Compleja/metabolismo , Epilepsia Parcial Compleja/cirugía , Epilepsia del Lóbulo Temporal/metabolismo , Epilepsia del Lóbulo Temporal/cirugía , Femenino , Glucosa/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Lóbulo Temporal/cirugía , Resultado del Tratamiento
10.
Ann Thorac Surg ; 61(1): 216-8, 1996 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8561560

RESUMEN

Adenomatous polyps of the esophagus are rare in comparison with those of the lower gastrointestinal tract. Like adenomatous colon polyps, they have been associated with malignancy. We describe a case of early adenocarcinoma and multiple polyposis of the esophagus arising in a Barrett's epithelium, treated with surgical resection.


Asunto(s)
Adenocarcinoma/complicaciones , Pólipos Adenomatosos/complicaciones , Esófago de Barrett/complicaciones , Neoplasias Esofágicas/complicaciones , Neoplasias Primarias Múltiples , Adenocarcinoma/patología , Adenocarcinoma/cirugía , Pólipos Adenomatosos/patología , Pólipos Adenomatosos/cirugía , Anciano , Esófago de Barrett/patología , Esófago de Barrett/cirugía , Neoplasias Esofágicas/patología , Neoplasias Esofágicas/cirugía , Humanos , Masculino , Neoplasias Primarias Múltiples/patología , Neoplasias Primarias Múltiples/cirugía
11.
IEEE Trans Med Imaging ; 15(4): 418-28, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-18215924

RESUMEN

Analysis of brain images often requires accurate localization of cortical convolutions. Although magnetic resonance (MR) brain images offer sufficient resolution for identifying convolutions in theory, the nature of tomographic imaging prevents clear definition of convolutions in individual slices. Existing methods for solving this problem rely on heuristic adaptation of brain atlases created from a small number of individuals. These methods do not usually provide high accuracy because of large biological variations among individuals. The authors propose to localize convolutions by linking realistic visualizations of the cortical surface with the original image volume. They have developed a system so that a user can quickly localize key convolutions in several visualizations of an entire brain surface. Because of the links between the visualizations and the original volume, these convolutions are simultaneously localized in the original image slices. In the process of the authors' development, they have implemented a fast and easy method for visualizing cortical surfaces in MR images, thereby making their scheme usable in practical applications.

12.
Ann Intern Med ; 123(8): 594-8, 1995 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-7677300

RESUMEN

OBJECTIVE: To determine whether a noninvasive method for evaluating contrast-enhancing brain lesions in patients with the acquired immunodeficiency syndrome (AIDS) can accurately differentiate between lymphoma and nonlymphoma diagnoses. This method is based on Toxoplasma serologic testing and positron emission tomography. DESIGN: Prospective, nonrandomized, criterion-standard clinical study. SETTING: An academic center in the mid-southeastern United States. PATIENTS: 20 patients with AIDS and contrast-enhancing brain lesions. INTERVENTIONS: Positron emission tomographic scanning and Toxoplasma serologic testing. MAIN OUTCOME MEASURE: Diagnoses were confirmed by clinical response, autopsy, or brain biopsy. RESULTS: Eight patients had a confirmed diagnosis of toxoplasmosis, six had lymphoma, four had other diagnoses, and two were not evaluable. Seven of eight patients with toxoplasmosis had positron emission tomographic scans; all of these scans showed hypometabolic lesions consistent with a nonlymphoma diagnosis. The six patients with lymphoma all had hypermetabolic lesions on positron emission tomographic scans. The difference between these two sets of results was statistically significant (P < 0.001, Fisher exact test, two-tailed). The anti-Toxoplasma titer was greater than or equal to 1:4 in all patients with confirmed toxoplasmosis who had serologic testing and in three of six patients with lymphoma. CONCLUSIONS: Evaluating contrast-enhancing brain lesions in patients with AIDS by using Toxoplasma serologic testing and positron emission tomography can accurately guide therapy and obviate the need for most brain biopsies in these patients. A larger, national, multicenter study is needed to confirm our findings and to determine the effect of earlier diagnosis and treatment on morbidity and mortality in patients with AIDS and primary central nervous system lymphoma.


Asunto(s)
Infecciones Oportunistas Relacionadas con el SIDA/diagnóstico por imagen , Linfoma Relacionado con SIDA/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Toxoplasmosis Cerebral/diagnóstico por imagen , Infecciones Oportunistas Relacionadas con el SIDA/tratamiento farmacológico , Adulto , Animales , Anticuerpos Antiprotozoarios/sangre , Diagnóstico Diferencial , Humanos , Linfoma Relacionado con SIDA/radioterapia , Persona de Mediana Edad , Estudios Prospectivos , Toxoplasma/aislamiento & purificación , Toxoplasmosis Cerebral/tratamiento farmacológico
13.
Ann Thorac Surg ; 60(2): 440-2, 1995 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7646113

RESUMEN

Fistula formation between the esophagus and airway in acquired immunodeficiency syndrome is extremely unusual. We report 2 cases, the first in a patient who did not undergo definitive surgical management and died shortly after diagnosis. The second patient was managed successfully for 5 months by insertion of a Celestin endoesophageal prosthesis. This procedure can be performed with low morbidity and mortality, and may become the treatment of choice for this complex problem.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida/complicaciones , Fístula Bronquial/complicaciones , Fístula Esofágica/complicaciones , Adulto , Fístula Bronquial/terapia , Fístula Esofágica/terapia , Resultado Fatal , Humanos , Masculino , Stents , Fístula Traqueoesofágica/complicaciones
14.
J Nucl Med ; 36(7): 1316-21, 1995 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-7790962

RESUMEN

UNLABELLED: Substituted benzamides have been shown to have very high affinity and specificity for the dopamine D2 receptor. One of these is radiolabeled epidepride, an iodine-substituted benzamide currently under evaluation as a SPECT imaging agent. Detailed estimates of the radiation absorbed dose to 26 organs and the whole body from [123I]epidepride have been calculated. METHODS: The dosimetry calculations use a combination of in vivo uptake and biodistribution data from one rhesus monkey and seven humans to estimate residence times in eight organs. The computer program MIRDOSE2 was used to calculate the dosimetry. RESULTS: Results indicate that 75% of the radioactivity is cleared through the urinary tract while the remaining radioactivity clears through the gallbladder and intestinal tract. The radiation absorbed dose can be minimized by administering a high lipid content meal 1.5 hr postinjection to empty the gallbladder and by giving large volumes of fluids throughout the study to induce increased urinary output. CONCLUSION: By emptying the gallbladder and urinary bladder, the lower large intestine becomes the critical organ, 0.102 mGy/MBq (0.38 rad/mCi) followed by the upper large intestine, 0.092 mGy/MBq (0.34 rad/mCi). The effective dose equivalent is 0.025 mSv/MBq (0.092 rem/mCi).


Asunto(s)
Benzamidas/farmacocinética , Radioisótopos de Yodo/farmacocinética , Pirrolidinas/farmacocinética , Receptores de Dopamina D2/análisis , Animales , Femenino , Humanos , Macaca mulatta , Masculino , Dosis de Radiación , Distribución Tisular , Tomografía Computarizada de Emisión de Fotón Único
15.
J Nucl Med ; 36(6): 988-95, 1995 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-7769457

RESUMEN

UNLABELLED: The clinical utility of FDG-PET imaging in the evaluation of patients with cardiac, oncologic and neurologic diseases is well documented. The major disadvantages of PET continue to be its high cost and limited availability. METHODS: With the goal of providing equivalent diagnostic information using a widely available, less expensive modality, we evaluated the clinical utility of FDG-SPECT imaging with a conventional dual-headed camera as compared to PET in 21 patients. RESULTS: To compare the image quality of the two modalities, major physical parameters and phantom determinations were obtained. By using the 511-keV collimators, we achieved resolution and system volume sensitivity that were less than those for PET by factors of 2.6 and 8, respectively. The SPECT system, on the other hand, could easily resolve 2 x 0.5-cm cold defects in the heart phantom and 2-cm hot lesions in a 22-cm cylindrical phantom with a target-to-background ratio of 5:1. FDG-SPECT imaging of nine patients with heart disease yielded similar diagnostic information of the amount of viable myocardium present when compared to PET. In seven of eight patients, malignant tissue visualized with FDG-PET was seen equally well with SPECT. The lesions not visualized with FDG-SPECT were either small (< or = 1.5 cm) or benign. SPECT imaging of four patients with cerebral lesions was inconclusive due to the small sample size but seemed promising. CONCLUSION: FDG-SPECT with 511-keV collimation is less expensive, more available and technically simpler than PET. We believe that FDG-SPECT has achieved sufficient sensitivity and resolution to detect myocardial viability and diagnose malignant tumors > or = 2 cm in diameter.


Asunto(s)
Desoxiglucosa/análogos & derivados , Radioisótopos de Flúor , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada de Emisión , Adulto , Anciano , Encéfalo/diagnóstico por imagen , Femenino , Fluorodesoxiglucosa F18 , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico por imagen , Sensibilidad y Especificidad
16.
Radiology ; 195(1): 47-52, 1995 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-7892494

RESUMEN

PURPOSE: To determine the optimal cutoff level of fluorine-18-labeled fluorodeoxyglucose (FDG) uptake in the differentiation of low-grade from high-grade cerebral tumors at position emission tomography (PET). MATERIALS AND METHODS: The authors retrospectively reviewed images from PET, magnetic resonance imaging, and computed tomography performed in 58 consecutive patients with histologically proved brain tumors. There were 32 high-grade tumors (20 gliomas) and 26 low-grade tumors (18 gliomas). RESULTS: The best cutoff level of FDG uptake ratios in the differentiation of high-grade from low-grade tumors was 1.5 for tumor-to-white matter (T/WM) ratios and 0.6 for tumor-to-cortex (T/C) ratios. These levels were the same when only gliomas were analyzed and when all tumors were analyzed. When a T/WM ratio of more than 1.5 was considered indicative of a high-grade tumor, the sensitivity and specificity were 94% and 77%, respectively. The results were similar for the T/C ratio. CONCLUSION: Cutoff levels of 1.5 for the T/WM FDG uptake ratio and 0.6 for the T/C ratio are useful in the differentiation of low-grade from high-grade gliomas with PET.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Desoxiglucosa/análogos & derivados , Radioisótopos de Flúor , Glioma/diagnóstico por imagen , Tomografía Computarizada de Emisión , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Neoplasias Encefálicas/patología , Diagnóstico Diferencial , Femenino , Fluorodesoxiglucosa F18 , Glioma/patología , Humanos , Imagen por Resonancia Magnética , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
18.
Acta Neurol Scand ; 91(2): 103-8, 1995 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-7785419

RESUMEN

Six adults and 2 children with focal inhibitory motor seizures (ictal paralysis) were evaluated during a 4-year period. Paresthesias at seizure onset occurred during some seizures in all patients, and focal clonic activity followed paralysis in 4. EEG-CCTV recordings of the seizures in 2 patients showed that ictal paralysis coincided with an ictal discharge starting in one centroparietal area. MRI showed centroparietal structural lesions in six patients. One patient with a normal MRI scan had right centroparietal hypometabolism on PET. Inhibitory motor seizures must be differentiated from transient ischemic attacks and migraine. In our patients a centroparietal epileptogenic focus was suggested by neuroimaging studies, and in 2 instances by ictal EEG.


Asunto(s)
Epilepsia Generalizada/fisiopatología , Hemiplejía/fisiopatología , Inhibición Neural/fisiología , Parálisis/fisiopatología , Lóbulo Parietal/fisiopatología , Adolescente , Adulto , Astrocitoma/patología , Astrocitoma/fisiopatología , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/fisiopatología , Niño , Preescolar , Dominancia Cerebral/fisiología , Electroencefalografía , Metabolismo Energético/fisiología , Epilepsia Generalizada/patología , Potenciales Evocados/fisiología , Femenino , Glioblastoma/patología , Glioblastoma/fisiopatología , Hemiplejía/patología , Humanos , Lipomatosis/patología , Lipomatosis/fisiopatología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Parálisis/patología , Lóbulo Parietal/patología , Tomografía Computarizada de Emisión , Grabación en Video
19.
J Comput Assist Tomogr ; 18(5): 800-10, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-8089332

RESUMEN

OBJECTIVE: We present a validation study of an algorithm for retrospective registration of PET and MR brain images. MATERIALS AND METHODS: This algorithm involves two steps. In the first step, the two volumes are reformatted by aligning their interhemispheric fissure planes (midsagittal plane). In the second step, the corresponding planes parallel to the midsagittal plane are further aligned in the reformatted volumes to produce a 3D rigid body registration of the two original volumes. It is an efficient algorithm because both steps are performed in 2D spaces, and in each step only a small number of landmarks are required. A user-friendly system has been implemented to facilitate easy and fast processing of registration and reformatting of image volumes. The accuracy of this algorithm is validated using clinical scans of neurosurgical patients with a stereotaxic frame attached to their skull. The frame-based stereotaxic system provides an effective method for transforming image coordinates from different image volumes into a common coordinate system. This common coordinate system is used for assessing the spatial correspondence of each pixel in the registered image volumes. Validation using the stereotaxic image volumes enables objective estimation of retrospective registration accuracy. RESULTS: Analysis of 11 MR/PET image pairs indicates that our registration method not only is efficient but also provides adequate accuracy for most clinical evaluation of PET studies. CONCLUSION: We have implemented and validated an efficient algorithm for retrospective registration of PET and MR brain images.


Asunto(s)
Algoritmos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Técnicas Estereotáxicas , Tomografía Computarizada de Emisión , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/diagnóstico por imagen , Desoxiglucosa/análogos & derivados , Femenino , Radioisótopos de Flúor , Fluorodesoxiglucosa F18 , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Modelos Estructurales , Reproducibilidad de los Resultados , Técnicas Estereotáxicas/instrumentación
20.
J Pharm Sci ; 83(3): 305-15, 1994 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8207673

RESUMEN

Lipophilic properties of 92 dopamine D-2 receptor antagonists belonging to the substituted benzamide class of compounds (orthopramides and methoxysalicylamides) were determined by octadecylsilane reversed-phase HPLC. The apparent lipophilicity at pH 7.5 (log kw) was obtained from the chromatographic capacity factors in 0.02 M3-(morpholino)propanesulfonic acid (MOPS) buffer at various concentrations of methanol. The experimental log kw values were validated by comparison with the apparent octanol-water partitioning (log Papp) of 15 compounds of low to medium lipophilicity. The global lipophilicity of the neutral molecule (log kwo) was obtained by correcting for ionization of the amine and the phenol, using known relationships for the effects on the pKa (where Ka is the dissociation constant) of aromatic and aliphatic substituents. Multiple regression analysis showed that log kwo can be expressed as the sum of pi contributions and a cross correlation term (sigma rho sigma) for interactions between the aromatic substituents. Comparison between the methoxysalicylamide (raclopride) series and the orthopramide (sulpiride) series demonstrated that an aromatic 6-hydroxy group increased log kw by 0.4 in the 5-halogen series and by 0.8 in the 5-alkyl series, and that a 6-methoxy group decreased log kw by 0.5. These paradoxical effects can be explained by the masking of the polarity of the amide caused by the 6-hydroxy group forming an intramolecular hydrogen bond with the amide carbonyl group. Introduction of an additional ortho-methoxy substituent had the opposite effect because the resulting steric hindrance prevents the amide moiety from adopting a coplanar conformation with the benzene ring. The presence of a substituent in the aromatic 3-position lowered log kw by 0.3 via a combination of steric and electronic influences on the adjacent 2-methoxy group, causing a weakening of the hydrogen bond between the amide and the oxygen atom of the 2-methoxy group. As a result, halogen and alkyl substituents in the 3-position increase the apparent lipophilicity only half that of similar substituents in the 5-position. Substitution with omega-fluoroalkoxyl groups in the aromatic 2- and 3-positions and with omega-fluoroalkyl groups in the 5-position reduced lipophilicities by 0.5 as compared with the corresponding desfluoro derivatives, thereby making them equivalent to an alkyl derivative with one less carbon atom in the chain. In contrast, substitution on the pyrrolidine nitrogen atom with a 2-fluoroethyl or a 3-fluoropropyl group produced compounds with apparent lipophilicities approximately 1.5 and approximately 0.5 higher, respectively, than those of the corresponding N-ethyl derivatives.(ABSTRACT TRUNCATED AT 400 WORDS)


Asunto(s)
Benzamidas/química , Antagonistas de los Receptores de Dopamina D2 , Pirrolidinas/química , Aminas/química , Benzamidas/síntesis química , Fenómenos Químicos , Química Física , Cromatografía Líquida de Alta Presión , Flúor/química , Yodo/química , Lípidos/química , Espectroscopía de Resonancia Magnética , Conformación Molecular , Pirrolidinas/síntesis química , Análisis de Regresión , Solubilidad , Relación Estructura-Actividad , Tomografía Computarizada de Emisión , Tomografía Computarizada de Emisión de Fotón Único
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA