Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Med Phys ; 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39008812

RESUMEN

BACKGROUND: Lesion detection is one of the most important clinical tasks in positron emission tomography (PET) for oncology. An anthropomorphic model observer (MO) designed to replicate human observers (HOs) in a detection task is an important tool for assessing task-based image quality. The channelized Hotelling observer (CHO) has been the most popular anthropomorphic MO. Recently, deep learning MOs (DLMOs), mostly based on convolutional neural networks (CNNs), have been investigated for various imaging modalities. However, there have been few studies on DLMOs for PET. PURPOSE: The goal of the study is to investigate whether DLMOs can predict HOs better than conventional MOs such as CHO in a two-alternative forced-choice (2AFC) detection task using PET images with real anatomical variability. METHODS: Two types of DLMOs were implemented: (1) CNN DLMO, and (2) CNN-SwinT DLMO that combines CNN and Swin Transformer (SwinT) encoders. Lesion-absent PET images were reconstructed from clinical data, and lesion-present images were reconstructed with adding simulated lesion sinogram data. Lesion-present and lesion-absent PET image pairs were labeled by eight HOs consisting of four radiologists and four image scientists in a 2AFC detection task. In total, 2268 pairs of lesion-present and lesion-absent images were used for training, 324 pairs for validation, and 324 pairs for test. CNN DLMO, CNN-SwinT DLMO, CHO with internal noise, and non-prewhitening matched filter (NPWMF) were compared in the same train-test paradigm. For comparison, six quantitative metrics including prediction accuracy, mean squared errors (MSEs) and correlation coefficients, which measure how well a MO predicts HOs, were calculated in a 9-fold cross-validation experiment. RESULTS: In terms of the accuracy and MSE metrics, CNN DLMO and CNN-SwinT DLMO showed better performance than CHO and NPWMF, and CNN-SwinT DLMO showed the best performance among the MOs evaluated. CONCLUSIONS: DLMO can predict HOs more accurately than conventional MOs such as CHO in PET lesion detection. Combining SwinT and CNN encoders can improve the DLMO prediction performance compared to using CNN only.

2.
JCO Precis Oncol ; 8: e2300687, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635935

RESUMEN

Radiomics, the science of extracting quantifiable data from routine medical images, is a powerful tool that has many potential applications in oncology. The Response Evaluation Criteria in Solid Tumors Working Group (RWG) held a workshop in May 2022, which brought together various stakeholders to discuss the potential role of radiomics in oncology drug development and clinical trials, particularly with respect to response assessment. This article summarizes the results of that workshop, reviewing radiomics for the practicing oncologist and highlighting the work that needs to be done to move forward the incorporation of radiomics into clinical trials.


Asunto(s)
Neoplasias , Medicina de Precisión , Humanos , Medicina de Precisión/métodos , Criterios de Evaluación de Respuesta en Tumores Sólidos , Radiómica , Oncología Médica , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico
3.
EJNMMI Res ; 14(1): 32, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38536511

RESUMEN

BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients that have bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases. METHODS: For this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified by the most commonly used PET parameter, the maximum tumor voxel normalized by dose and body weight (SUVmax) and also by the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals for SUVmax and SULpeak were used to determine the limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax and SULpeak in 38 bone tumors of the first cohort were 4.3% and 6.7%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and - 16.3% for SUVmax, and 21.2% and - 17.5% for SULpeak. 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification using SULpeak for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria for SULpeak changed the status of 3 patients compared to the standard Positron Emission Tomography Response Criteria in Solid Tumors of ± 30% SULpeak. CONCLUSION: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG SUVmax, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions in these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.

4.
Res Sq ; 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38313279

RESUMEN

BACKGROUND: Standard measures of response such as Response Evaluation Criteria in Solid Tumors are ineffective for bone lesions, often making breast cancer patients with bone-dominant metastases ineligible for clinical trials with potentially helpful therapies. In this study we prospectively evaluated the test-retest uptake variability of 2-deoxy-2-[18F]fluoro-D-glucose (18F-FDG) in a cohort of breast cancer patients with bone-dominant metastases to determine response criteria. The thresholds for 95% specificity of change versus no-change were then applied to a second cohort of breast cancer patients with bone-dominant metastases.In this study, nine patients with 38 bone lesions were imaged with 18F-FDG in the same calibrated scanner twice within 14 days. Tumor uptake was quantified as the maximum tumor voxel normalized by dose and body weight (SUVmax) and the mean of a 1-cc maximal uptake volume normalized by dose and lean-body-mass (SULpeak). The asymmetric repeatability coefficients with confidence intervals of SUVmax and SULpeak were used to determine limits of 18F-FDG uptake variability. A second cohort of 28 breast cancer patients with bone-dominant metastases that had 146 metastatic bone lesions was imaged with 18F-FDG before and after standard-of-care therapy for response assessment. RESULTS: The mean relative difference of SUVmax in 38 bone tumors of the first cohort was 4.3%. The upper and lower asymmetric limits of the repeatability coefficient were 19.4% and -16.3%, respectively. The 18F-FDG repeatability coefficient confidence intervals resulted in the following patient stratification for the second patient cohort: 11-progressive disease, 5-stable disease, 7-partial response, and 1-complete response with three inevaluable patients. The asymmetric repeatability coefficients response criteria changed the status of 3 patients compared to standard the standard Positron Emission Tomography Response Criteria in Solid Tumors of ±30% SULpeak. CONCLUSIONS: In evaluating bone tumor response for breast cancer patients with bone-dominant metastases using 18F-FDG uptake, the repeatability coefficients from test-retest studies show that reductions of more than 17% and increases of more than 20% are unlikely to be due to measurement variability. Serial 18F-FDG imaging in clinical trials investigating bone lesions from these patients, such as the ECOG-ACRIN EA1183 trial, benefit from confidence limits that allow interpretation of response.

5.
IEEE Trans Radiat Plasma Med Sci ; 7(4): 333-343, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37396797

RESUMEN

Historically, patient datasets have been used to develop and validate various reconstruction algorithms for PET/MRI and PET/CT. To enable such algorithm development, without the need for acquiring hundreds of patient exams, in this article we demonstrate a deep learning technique to generate synthetic but realistic whole-body PET sinograms from abundantly available whole-body MRI. Specifically, we use a dataset of 56 18F-FDG-PET/MRI exams to train a 3-D residual UNet to predict physiologic PET uptake from whole-body T1-weighted MRI. In training, we implemented a balanced loss function to generate realistic uptake across a large dynamic range and computed losses along tomographic lines of response to mimic the PET acquisition. The predicted PET images are forward projected to produce synthetic PET (sPET) time-of-flight (ToF) sinograms that can be used with vendor-provided PET reconstruction algorithms, including using CT-based attenuation correction (CTAC) and MR-based attenuation correction (MRAC). The resulting synthetic data recapitulates physiologic 18F-FDG uptake, e.g., high uptake localized to the brain and bladder, as well as uptake in liver, kidneys, heart, and muscle. To simulate abnormalities with high uptake, we also insert synthetic lesions. We demonstrate that this sPET data can be used interchangeably with real PET data for the PET quantification task of comparing CTAC and MRAC methods, achieving ≤ 7.6% error in mean-SUV compared to using real data. These results together show that the proposed sPET data pipeline can be reasonably used for development, evaluation, and validation of PET/MRI reconstruction methods.

6.
Cancers (Basel) ; 15(13)2023 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-37444527

RESUMEN

The clinical management of patients with indeterminate pulmonary nodules is associated with unintended harm to patients and better methods are required to more precisely quantify lung cancer risk in this group. Here, we combine multiple noninvasive approaches to more accurately identify lung cancer in indeterminate pulmonary nodules. We analyzed 94 quantitative radiomic imaging features and 41 qualitative semantic imaging variables with molecular biomarkers from blood derived from an antibody-based microarray platform that determines protein, cancer-specific glycan, and autoantibody-antigen complex content with high sensitivity. From these datasets, we created a PSR (plasma, semantic, radiomic) risk prediction model comprising nine blood-based and imaging biomarkers with an area under the receiver operating curve (AUROC) of 0.964 that when tested in a second, independent cohort yielded an AUROC of 0.846. Incorporating known clinical risk factors (age, gender, and smoking pack years) for lung cancer into the PSR model improved the AUROC to 0.897 in the second cohort and was more accurate than a well-characterized clinical risk prediction model (AUROC = 0.802). Our findings support the use of a multi-omics approach to guide the clinical management of indeterminate pulmonary nodules.

7.
Tomography ; 9(3): 995-1009, 2023 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-37218941

RESUMEN

Preclinical imaging is a critical component in translational research with significant complexities in workflow and site differences in deployment. Importantly, the National Cancer Institute's (NCI) precision medicine initiative emphasizes the use of translational co-clinical oncology models to address the biological and molecular bases of cancer prevention and treatment. The use of oncology models, such as patient-derived tumor xenografts (PDX) and genetically engineered mouse models (GEMMs), has ushered in an era of co-clinical trials by which preclinical studies can inform clinical trials and protocols, thus bridging the translational divide in cancer research. Similarly, preclinical imaging fills a translational gap as an enabling technology for translational imaging research. Unlike clinical imaging, where equipment manufacturers strive to meet standards in practice at clinical sites, standards are neither fully developed nor implemented in preclinical imaging. This fundamentally limits the collection and reporting of metadata to qualify preclinical imaging studies, thereby hindering open science and impacting the reproducibility of co-clinical imaging research. To begin to address these issues, the NCI co-clinical imaging research program (CIRP) conducted a survey to identify metadata requirements for reproducible quantitative co-clinical imaging. The enclosed consensus-based report summarizes co-clinical imaging metadata information (CIMI) to support quantitative co-clinical imaging research with broad implications for capturing co-clinical data, enabling interoperability and data sharing, as well as potentially leading to updates to the preclinical Digital Imaging and Communications in Medicine (DICOM) standard.


Asunto(s)
Metadatos , Neoplasias , Animales , Ratones , Humanos , Reproducibilidad de los Resultados , Diagnóstico por Imagen , Neoplasias/diagnóstico por imagen , Estándares de Referencia
8.
Tomography ; 9(2): 750-758, 2023 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-37104131

RESUMEN

Providing method descriptions that are more detailed than currently available in typical peer reviewed journals has been identified as an actionable area for improvement. In the biochemical and cell biology space, this need has been met through the creation of new journals focused on detailed protocols and materials sourcing. However, this format is not well suited for capturing instrument validation, detailed imaging protocols, and extensive statistical analysis. Furthermore, the need for additional information must be counterbalanced by the additional time burden placed upon researchers who may be already overtasked. To address these competing issues, this white paper describes protocol templates for positron emission tomography (PET), X-ray computed tomography (CT), and magnetic resonance imaging (MRI) that can be leveraged by the broad community of quantitative imaging experts to write and self-publish protocols in protocols.io. Similar to the Structured Transparent Accessible Reproducible (STAR) or Journal of Visualized Experiments (JoVE) articles, authors are encouraged to publish peer reviewed papers and then to submit more detailed experimental protocols using this template to the online resource. Such protocols should be easy to use, readily accessible, readily searchable, considered open access, enable community feedback, editable, and citable by the author.


Asunto(s)
Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Imagen por Resonancia Magnética
9.
Tomography ; 9(2): 657-680, 2023 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-36961012

RESUMEN

The availability of high-fidelity animal models for oncology research has grown enormously in recent years, enabling preclinical studies relevant to prevention, diagnosis, and treatment of cancer to be undertaken. This has led to increased opportunities to conduct co-clinical trials, which are studies on patients that are carried out parallel to or sequentially with animal models of cancer that mirror the biology of the patients' tumors. Patient-derived xenografts (PDX) and genetically engineered mouse models (GEMM) are considered to be the models that best represent human disease and have high translational value. Notably, one element of co-clinical trials that still needs significant optimization is quantitative imaging. The National Cancer Institute has organized a Co-Clinical Imaging Resource Program (CIRP) network to establish best practices for co-clinical imaging and to optimize translational quantitative imaging methodologies. This overview describes the ten co-clinical trials of investigators from eleven institutions who are currently supported by the CIRP initiative and are members of the Animal Models and Co-clinical Trials (AMCT) Working Group. Each team describes their corresponding clinical trial, type of cancer targeted, rationale for choice of animal models, therapy, and imaging modalities. The strengths and weaknesses of the co-clinical trial design and the challenges encountered are considered. The rich research resources generated by the members of the AMCT Working Group will benefit the broad research community and improve the quality and translational impact of imaging in co-clinical trials.


Asunto(s)
Neoplasias , Animales , Ratones , Humanos , Neoplasias/diagnóstico por imagen , Neoplasias/terapia , Neoplasias/patología , Modelos Animales de Enfermedad , Diagnóstico por Imagen
10.
Tomography ; 9(1): 375-386, 2023 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-36828382

RESUMEN

Relevant to co-clinical trials, the goal of this work was to assess repeatability, reproducibility, and bias of the apparent diffusion coefficient (ADC) for preclinical MRIs using standardized procedures for comparison to performance of clinical MRIs. A temperature-controlled phantom provided an absolute reference standard to measure spatial uniformity of these performance metrics. Seven institutions participated in the study, wherein diffusion-weighted imaging (DWI) data were acquired over multiple days on 10 preclinical scanners, from 3 vendors, at 6 field strengths. Centralized versus site-based analysis was compared to illustrate incremental variance due to processing workflow. At magnet isocenter, short-term (intra-exam) and long-term (multiday) repeatability were excellent at within-system coefficient of variance, wCV [±CI] = 0.73% [0.54%, 1.12%] and 1.26% [0.94%, 1.89%], respectively. The cross-system reproducibility coefficient, RDC [±CI] = 0.188 [0.129, 0.343] µm2/ms, corresponded to 17% [12%, 31%] relative to the reference standard. Absolute bias at isocenter was low (within 4%) for 8 of 10 systems, whereas two high-bias (>10%) scanners were primary contributors to the relatively high RDC. Significant additional variance (>2%) due to site-specific analysis was observed for 2 of 10 systems. Base-level technical bias, repeatability, reproducibility, and spatial uniformity patterns were consistent with human MRIs (scaled for bore size). Well-calibrated preclinical MRI systems are capable of highly repeatable and reproducible ADC measurements.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Benchmarking
11.
Nat Rev Clin Oncol ; 20(2): 69-82, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36443594

RESUMEN

Computer-extracted tumour characteristics have been incorporated into medical imaging computer-aided diagnosis (CAD) algorithms for decades. With the advent of radiomics, an extension of CAD involving high-throughput computer-extracted quantitative characterization of healthy or pathological structures and processes as captured by medical imaging, interest in such computer-extracted measurements has increased substantially. However, despite the thousands of radiomic studies, the number of settings in which radiomics has been successfully translated into a clinically useful tool or has obtained FDA clearance is comparatively small. This relative dearth might be attributable to factors such as the varying imaging and radiomic feature extraction protocols used from study to study, the numerous potential pitfalls in the analysis of radiomic data, and the lack of studies showing that acting upon a radiomic-based tool leads to a favourable benefit-risk balance for the patient. Several guidelines on specific aspects of radiomic data acquisition and analysis are already available, although a similar roadmap for the overall process of translating radiomics into tools that can be used in clinical care is needed. Herein, we provide 16 criteria for the effective execution of this process in the hopes that they will guide the development of more clinically useful radiomic tests in the future.

12.
Med Phys ; 50(5): 2998-3007, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36576853

RESUMEN

PURPOSE: The main goal of this work is to describe a phantom design, data acquisition and data analysis methodology enabling comparison of small lesion detectability between PET imaging systems and reconstruction algorithms. Several methods are currently available to characterize intrinsic and image quality performance, but none focus exclusively on small lesion detectability. METHODS: We previously developed a small-lesion detection phantom and described initial results using a head-size phantom. Unlike most fillable nuclear medicine phantoms, this phantom offers a semi-realistic heterogenous background and wall-less contrast features. In this work, the methodology is extended to include (a) the use of both head- and body-sized phantoms and (b) a multi-scan data collection and analysis method. We present an example use case of the phantom and detection estimation methodology, comparing the small-lesion detection performance across four commercial PET/CT systems. RESULTS: Repeat acquisitions of the phantom enabled estimation of model observer performance and surrogates of detectability. As anticipated, estimated detectability increased with the square root of system sensitivity and TOF offered marked improvement in detectability, especially for the body sized object. The proposed approach characterizing detectability at different times during the decay of the phantom enabled comparison of small lesion detectability at matched activity concentrations (and scan durations) across different scanners. CONCLUSION: The proposed approach offers a reproducible tool for evaluating relative tradeoffs of system performance on small lesion detectability.


Asunto(s)
Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Algoritmos , Fantasmas de Imagen , Tomografía de Emisión de Positrones/métodos , Procesamiento de Imagen Asistido por Computador/métodos
14.
Acad Radiol ; 30(2): 196-214, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36273996

RESUMEN

Combinations of multiple quantitative imaging biomarkers (QIBs) are often able to predict the likelihood of an event of interest such as death or disease recurrence more effectively than single imaging measurements can alone. The development of such multiparametric quantitative imaging and evaluation of its fitness of use differs from the analogous processes for individual QIBs in several key aspects. A computational procedure to combine the QIB values into a model output must be specified. The output must also be reproducible and be shown to have reasonably strong ability to predict the risk of an event of interest. Attention must be paid to statistical issues not often encountered in the single QIB scenario, including overfitting and bias in the estimates of model performance. This is the fourth in a five-part series on statistical methodology for assessing the technical performance of multiparametric quantitative imaging. Considerations for data acquisition are discussed and recommendations from the literature on methodology to construct and evaluate QIB-based models for risk prediction are summarized. The findings in the literature upon which these recommendations are based are demonstrated through simulation studies. The concepts in this manuscript are applied to a real-life example involving prediction of major adverse cardiac events using automated plaque analysis.


Asunto(s)
Diagnóstico por Imagen , Humanos , Diagnóstico por Imagen/métodos , Biomarcadores , Simulación por Computador
15.
J Nucl Med ; 64(2): 294-303, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36137760

RESUMEN

A standardized approach to acquiring amyloid PET images increases their value as disease and drug response biomarkers. Most 18F PET amyloid brain scans often are assessed only visually (per regulatory labels), with a binary decision indicating the presence or absence of Alzheimer disease amyloid pathology. Minimizing technical variance allows precise, quantitative SUV ratios (SUVRs) for early detection of ß-amyloid plaques and allows the effectiveness of antiamyloid treatments to be assessed with serial studies. Methods: The Quantitative Imaging Biomarkers Alliance amyloid PET biomarker committee developed and validated a profile to characterize and reduce the variability of SUVRs, increasing statistical power for these assessments. Results: On achieving conformance, sites can justify a claim that brain amyloid burden reflected by the SUVR is measurable to a within-subject coefficient of variation of no more than 1.94% when the same radiopharmaceutical, scanner, acquisition, and analysis protocols are used. Conclusion: This overview explains the claim, requirements, barriers, and potential future developments of the profile to achieve precision in clinical and research amyloid PET imaging.


Asunto(s)
Enfermedad de Alzheimer , Procesamiento de Imagen Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía de Emisión de Positrones/métodos , Enfermedad de Alzheimer/patología , Péptidos beta-Amiloides/metabolismo , Encéfalo/metabolismo , Biomarcadores , Amiloide/metabolismo , Compuestos de Anilina
16.
Discov Oncol ; 13(1): 85, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36048266

RESUMEN

BACKGROUND: Patients undergoing chemoradiation and immune checkpoint inhibitor (ICI) therapy for locally advanced non-small cell lung cancer (NSCLC) experience pulmonary toxicity at higher rates than historical reports. Identifying biomarkers beyond conventional clinical factors and radiation dosimetry is especially relevant in the modern cancer immunotherapy era. We investigated the role of novel functional lung radiomics, relative to functional lung dosimetry and clinical characteristics, for pneumonitis risk stratification in locally advanced NSCLC. METHODS: Patients with locally advanced NSCLC were prospectively enrolled on the FLARE-RT trial (NCT02773238). All received concurrent chemoradiation using functional lung avoidance planning, while approximately half received consolidation durvalumab ICI. Within tumour-subtracted lung regions, 110 radiomics features (size, shape, intensity, texture) were extracted on pre-treatment [99mTc]MAA SPECT/CT perfusion images using fixed-bin-width discretization. The performance of functional lung radiomics for pneumonitis (CTCAE v4 grade 2 or higher) risk stratification was benchmarked against previously reported lung dosimetric parameters and clinical risk factors. Multivariate least absolute shrinkage and selection operator Cox models of time-varying pneumonitis risk were constructed, and prediction performance was evaluated using optimism-adjusted concordance index (c-index) with 95% confidence interval reporting throughout. RESULTS: Thirty-nine patients were included in the study and pneumonitis occurred in 16/39 (41%) patients. Among clinical characteristics and anatomic/functional lung dosimetry variables, only the presence of baseline chronic obstructive pulmonary disease (COPD) was significantly associated with the development of pneumonitis (HR 4.59 [1.69-12.49]) and served as the primary prediction benchmark model (c-index 0.69 [0.59-0.80]). Discrimination of time-varying pneumonitis risk was numerically higher when combining COPD with perfused lung radiomics size (c-index 0.77 [0.65-0.88]) or shape feature classes (c-index 0.79 [0.66-0.91]) but did not reach statistical significance compared to benchmark models (p > 0.26). COPD was associated with perfused lung radiomics size features, including patients with larger lung volumes (AUC 0.75 [0.59-0.91]). Perfused lung radiomic texture features were correlated with lung volume (adj R2 = 0.84-1.00), representing surrogates rather than independent predictors of pneumonitis risk. CONCLUSIONS: In patients undergoing chemoradiation with functional lung avoidance therapy and optional consolidative immune checkpoint inhibitor therapy for locally advanced NSCLC, the strongest predictor of pneumonitis was the presence of baseline chronic obstructive pulmonary disease. Results from this novel functional lung radiomics exploratory study can inform future validation studies to refine pneumonitis risk models following combinations of radiation and immunotherapy. Our results support functional lung radiomics as surrogates of COPD for non-invasive monitoring during and after treatment. Further study of clinical, dosimetric, and radiomic feature combinations for radiation and immune-mediated pneumonitis risk stratification in a larger patient population is warranted.

17.
EJHaem ; 3(2): 406-414, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35846039

RESUMEN

Image texture analysis (radiomics) uses radiographic images to quantify characteristics that may identify tumour heterogeneity and associated patient outcomes. Using fluoro-deoxy-glucose positron emission tomography/computed tomography (FDG-PET/CT)-derived data, including quantitative metrics, image texture analysis and other clinical risk factors, we aimed to develop a prognostic model that predicts survival in patients with previously untreated diffuse large B-cell lymphoma (DLBCL) from GOYA (NCT01287741). Image texture features and clinical risk factors were combined into a random forest model and compared with the international prognostic index (IPI) for DLBCL based on progression-free survival (PFS) and overall survival (OS) predictions. Baseline FDG-PET scans were available for 1263 patients, 832 patients of these were cell-of-origin (COO)-evaluable. Patients were stratified by IPI or radiomics features plus clinical risk factors into low-, intermediate- and high-risk groups. The random forest model with COO subgroups identified a clearer high-risk population (45% 2-year PFS [95% confidence interval (CI) 40%-52%]; 65% 2-year OS [95% CI 59%-71%]) than the IPI (58% 2-year PFS [95% CI 50%-67%]; 69% 2-year OS [95% CI 62%-77%]). This study confirms that standard clinical risk factors can be combined with PET-derived image texture features to provide an improved prognostic model predicting survival in untreated DLBCL.

18.
Adv Radiat Oncol ; 7(2): 100857, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35387421

RESUMEN

Purpose: We sought to examine the prognostic value of fluorodeoxyglucose-positron emission tomography (PET) imaging during chemoradiation for unresectable non-small cell lung cancer for survival and hypothesized that tumor PET response is correlated with peripheral T-cell function. Methods and Materials: Forty-five patients with American Joint Committee on Cancer version 7 stage IIB-IIIB non-small cell lung cancer enrolled in a phase II trial and received platinum-doublet chemotherapy concurrent with 6 weeks of radiation (NCT02773238). Fluorodeoxyglucose-PET was performed before treatment start and after 24 Gy of radiation (week 3). PET response status was prospectively defined by multifactorial radiologic interpretation. PET responders received 60 Gy in 30 fractions, while nonresponders received concomitant boosts to 74 Gy in 30 fractions. Peripheral blood was drawn synchronously with PET imaging, from which germline DNA sequencing, T-cell receptor sequencing, and plasma cytokine analysis were performed. Results: Median follow-up was 18.8 months, 1-year overall survival (OS) 82%, 1-year progression-free survival 53%, and 1-year locoregional control 88%. Higher midtreatment PET total lesion glycolysis was detrimental to OS (1 year 87% vs 63%, P < .001), progression-free survival (1 year 60% vs 26%, P = .044), and locoregional control (1 year 94% vs 65%, P = .012), even after adjustment for clinical/treatment factors. Twenty-nine of 45 patients (64%) were classified as PET responders based on a priori definition. Higher tumor programmed death-ligand 1 expression was correlated with response on PET (P = .017). Higher T-cell receptor richness and clone distribution slope were associated with improved OS (P = .018-0.035); clone distribution slope was correlated with PET response (P = .031). Conclusions: Midchemoradiation PET imaging is prognostic for survival; PET response may be linked to tumor and peripheral T-cell biomarkers.

19.
Radiol Clin North Am ; 60(2): 339-358, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35236598

RESUMEN

AI can improve the quality of CT, MR and PET/CT images, while simultaneously reducing imaging time, and doses of radiation and contrast. AI can improve radiologist workflow and decrease interpretation times. AI may someday be capable of accurately locating, classifying and segmenting bone and soft tissue tumors. The goal of radiomics is to use radiomic and other biomarkers to achieve "precision medicine", ie, to predict the right diagnosis and the right treatment of the right patient at the right time. Radiomic information may be helpful in guiding biopsies, classifying and grading tumors and predicting prognosis and treatment response.


Asunto(s)
Inteligencia Artificial , Neoplasias de los Tejidos Blandos , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Medicina de Precisión , Pronóstico , Neoplasias de los Tejidos Blandos/diagnóstico por imagen
20.
J Nucl Med ; 63(4): 615-621, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34301784

RESUMEN

PET/MRI scanners cannot be qualified in the manner adopted for hybrid PET/CT devices. The main hurdle with qualification in PET/MRI is that attenuation correction (AC) cannot be adequately measured in conventional PET phantoms because of the difficulty in converting the MR images of the physical structures (e.g., plastic) into electron density maps. Over the last decade, a plethora of novel MRI-based algorithms has been developed to more accurately derive the attenuation properties of the human head, including the skull. Although promising, none of these techniques has yet emerged as an optimal and universally adopted strategy for AC in PET/MRI. In this work, we propose a path for PET/MRI qualification for multicenter brain imaging studies. Specifically, our solution is to separate the head AC from the other factors that affect PET data quantification and use a patient as a phantom to assess the former. The emission data collected on the integrated PET/MRI scanner to be qualified should be reconstructed using both MRI- and CT-based AC methods, and whole-brain qualitative and quantitative (both voxelwise and regional) analyses should be performed. The MRI-based approach will be considered satisfactory if the PET quantification bias is within the acceptance criteria specified here. We have implemented this approach successfully across 2 PET/MRI scanner manufacturers at 2 sites.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Tomografía de Emisión de Positrones , Encéfalo/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen , Tomografía de Emisión de Positrones/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA