1.
Clinicoecon Outcomes Res ; 11: 385-393, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31239735

RESUMEN

Background: The hOLter for Efficacy analysis (OLE) study demonstrated that current device pacing diagnostics overestimate the amount of cardiac resynchronization therapy (CRT) pacing that effectively stimulates the cardiac tissue. Sub-optimal pacing increases mortality, hospitalizations, and associated health-care costs. We sought to estimate the expected number of hospital admissions due to heart failure (HF) and its respective financial impact in patients with maximized effective pacing versus conventional pacing. Methods: A Markov model was developed to project HF hospitalizations and quantify the costs that could be avoided if pacing was maximally effective. OLE data were used to inform the prevalence of ineffective pacing among CRT patients and and average loss of pacing by causes. Adaptive CRT trial data quantified the reduction in underlying hospitalization risk by increasing effective pacing delivered. Survival was informed by a meta-analysis of 5 randomized clinical trials. Costs were analyzed from a US payer perspective. Results: Projected average hospitalizations totaled 4.58 over a lifetime horizon for CRT patients with conventional pacing. Maximizing effective pacing delivery was projected to avoid 1.83 HF admissions/patient over the lifetime. This equates to a savings of 40% (US$22,802) compared with conventional pacing from the Medicare perspective. In a sensitivity analysis, CRT with effective pacing was projected to provide cost savings in all scenarios. Conclusions: Maximized effective pacing leads to a lower number of HF hospitalizations, thus allowing significant cost offsets in the US setting.

2.
Heart Rhythm ; 15(3): 369-375, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29132930

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) requires a high percentage of ventricular pacing (%Vp) to maximize its clinical benefits. Atrial fibrillation (AF) has been shown to reduce %Vp in CRT due to competition with irregular intrinsic atrioventricular (AV) conduction. We report the results of a prospective randomized crossover trial evaluating the amount of effective CRT delivered during AF with a novel algorithm (eCRTAF). OBJECTIVE: The purpose of this study was to determine whether eCRTAF increases the amount of effective CRT delivered during AF compared to a currently available rate regularization algorithm. METHODS: Patients previously implanted with a cardiac resynchronization therapy-defibrillator and with a history of AF and intact AV conduction received up to 4 weeks of control (Conducted AF Response) and up to 4 weeks of eCRTAF in a randomized sequence. The percent effective CRT (%eCRT) pacing, which excludes beats without left ventricular capture, %Vp, and mean heart rate (HR) were recorded during AF and sinus rhythm. RESULTS: The eCRTAF algorithm resulted in a significantly higher %eCRT during AF than control (87.8% ± 7.8% vs 80.8% ± 14.3%; P <.001) and %Vp during AF than control (90.0% ± 5.9% vs 83.2% ± 11.9%; P <.001), with a small but statistically significant increase in mean HR of 2.5 bpm (79.5 ± 9.7 bpm vs 77.0 ± 9.9 bpm; P <.001). CONCLUSION: In a cohort of CRT patients with a history of AF, eCRTAF significantly increased %eCRT pacing and %Vp during AF with a small increase in mean HR. This algorithm may represent a novel noninvasive method of significantly increasing effective CRT delivery during AF, potentially improving CRT response.


Asunto(s)
Algoritmos , Fibrilación Atrial/terapia , Terapia de Resincronización Cardíaca/métodos , Sistema de Conducción Cardíaco/fisiopatología , Ventrículos Cardíacos/fisiopatología , Fibrilación Atrial/fisiopatología , Estudios Cruzados , Humanos , Estudios Prospectivos , Resultado del Tratamiento
4.
Heart Rhythm ; 14(4): 541-547, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28104482

RESUMEN

BACKGROUND: A high percentage of biventricular (BiV) or left ventricular (LV) pacing in cardiac resynchronization therapy (CRT) devices has been associated with superior clinical outcomes. However, the percent ventricular (%V) pacing reported by CRT devices simply indicates the number of paces the device has delivered and not the proportion of pacing that has captured the LV effectively. OBJECTIVE: The purpose of this study was to determine whether a beat-by-beat evaluation of effective pacing would provide a more accurate evaluation of CRT delivery. METHODS: An automatic electrogram (EGM)-based algorithm that classifies each LV pace as effective or ineffective based on detection of QS/QS-r morphology on the unipolar LV EGM during pacing was developed and validated. LV EGMs that were recorded by 24-hour Holter from 57 CRT patients were postprocessed. The percent effective CRT (%e-CRT) pacing was calculated by dividing the time spent in e-CRT pacing by the total time of the recording. RESULTS: In this CRT cohort, the average %V pacing (94.8% ± 8%) significantly overestimated the %e-CRT pacing (87.5% ± 23%; P <.001). A significant minority of subjects (18%) had a discrepancy of at least 3 percentage points between %V pacing and %e-CRT pacing (mean 39% ± 41%). CONCLUSION: Current device pacing diagnostics overestimate the amount of CRT pacing actually delivered. The new algorithm quantifies ineffective CRT pacing, which enables clinicians to identify patients with this issue and to address the reasons behind suboptimal CRT delivery.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Electrocardiografía Ambulatoria/métodos , Técnicas Electrofisiológicas Cardíacas , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , España/epidemiología , Resultado del Tratamiento
5.
Heart Fail Rev ; 16(3): 315-25, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21104313

RESUMEN

In this review, we report on electrical modalities, which do not fit the definition of pacemaker, but increase cardiac performance either by direct application to the heart (e.g., post-extrasystolic potentiation or non-excitatory stimulation) or indirectly through activation of the nervous system (e.g., vagal or sympathetic activation). The physiological background of the possible mechanisms of these electrical modalities and their potential application to treat heart failure are discussed.


Asunto(s)
Estimulación Eléctrica , Insuficiencia Cardíaca/fisiopatología , Contracción Miocárdica , Sistema Nervioso Simpático/fisiopatología , Nervio Vago/fisiopatología , Estimulación Eléctrica/métodos , Insuficiencia Cardíaca/terapia , Humanos
6.
J Card Fail ; 14(1): 35-40, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18226771

RESUMEN

BACKGROUND: Postextrasystolic potentiation (PESP) is a property of cardiac tissue whereby two closely timed depolarizations cause the subsequent contraction to be of increased magnitude. METHODS AND RESULTS: Ten subjects were studied in a single-blind study to evaluate the safety and performance of an atrioventricular coupled pacing (A-VCP) algorithm to produce sustained PESP among subjects with moderate heart failure. The primary end points were algorithm safety, patient perception, and cardiac function. The effects of A-VCP on cardiac function were assessed by comparing echocardiographic parameters before and after 15 to 20 minutes of A-VCP. A-VCP produced no arrhythmic episodes, ejection fraction increased by 8 ejection fraction points (31%) (P < or = .001), end-systolic volume decreased by 10% (P < or = .05), and a trend toward increasing end-diastolic volume was observed (P = .084). Stroke volume increased by 43% (P < or = .001), and the pulse rate decreased by 41% (P < or = .001) during A-VCP. This resulted in decreased cardiac output of 15% (P < or = .05). Six of the 10 subjects felt no effects from A-VCP, and four subjects felt a change with A-VCP turned on. CONCLUSION: Short-term A-VCP was found to be safe and well tolerated in a majority of patients. Hemodynamic effects were mixed with improved ejection fraction and stroke volume but decreased cardiac output.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Hemodinámica/fisiología , Adulto , Anciano , Algoritmos , Ecocardiografía Doppler de Pulso , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/mortalidad , Pruebas de Función Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Probabilidad , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Método Simple Ciego , Volumen Sistólico/fisiología , Tasa de Supervivencia , Resultado del Tratamiento