Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 157
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-39269656

RESUMEN

PURPOSE: Quantification of PSMA expression via PSMA PET is well-established, however quantification of PSMA via immunohistochemistry (IHC) is not standardized. Our aim was to determine the most optimal PSMA IHC scoring system to quantify PSMA expression with PSMA PET as reference standard. METHODS: Primary intermediate- and high-risk prostate cancer patients received an [18F]PSMA-1007 PET/MRI followed by radical prostatectomy. SUVmax, SUVmean and Ki of the prostate tumor was determined. Prostate tumors were stained with anti-PSMA antibodies and scored by 2 readers via 10 IHC scoring systems: histochemical score (H-score), immunoreactivity scorepredominant intensity (IRSpredominant intensity), IRS classificationpredominant intensity, IRSmean intensity, IRS classificationmean intensity, Allred score, predominant expression pattern, Shannon diversity index (SDI), percentage negatively stained cells and total percentage positively stained cells. Spearman's rank correlation coefficients (ρ) were calculated between PET parameters and IHC scoring systems. Interreader agreement for the IHC scoring systems was measured by the intraclass correlation coefficient (ICC). RESULTS: Fifty tumors in 46 patients were analysed. H-score had the best correlation with SUVmax (ρ 0.615 p < 0.0001) and SUVmean (ρ 0.570, p < 0.0001) and the second best correlation with Ki (ρ 0.411, p = 0.0030). SDI had the best correlation with Ki (ρ -0.440, p = 0.0014) and the second best correlation with SUVmax (ρ -0.516, p = 0.0001) and SUVmean (ρ -0.490, p = 0.0003). A moderate interreader agreement was observed for H-score (ICC 0.663, 95% CI 0.495-0.797) and SDI (ICC 0.546, 95% CI 0.354-0.725). CONCLUSION: H-score had the best correlation with PSMA PET quantification and an acceptable interreader agreement. Therefore, we deem H-score the most optimal PSMA IHC scoring system.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39107144

RESUMEN

OBJECTIVE: To investigate whether tau accumulation is higher in late life depression (LLD) compared to non-depressed cognitively unimpaired (CU) older adults. To situate these findings in the neurodegeneration model of LLD by assessing group differences in tau and grey matter volume (GMV) between LLD, non-depressed CU and mild cognitive impairment due to Alzheimer's Disease (MCI). DESIGN: Monocentric, cross-sectional study. SETTING: University Psychiatric hospital, memory clinic and outpatient neurology practice. PARTICIPANTS: A total of 102 adults over age 60, of whom 19 currently depressed participants with LLD, 19 with MCI and 36 non-depressed CU participants completed neuropsychological testing and tau PET-MR imaging. MEASUREMENTS: PET-MRI: 18F-MK-6240 tracer SUVR for tau assessment; 3D T1-weighted structural MRI derived GMV in seven brain regions (temporal, cingulate, prefrontal and parietal regions); amyloid PET to assess amyloid positivity; Neuropsychological test scores: MMSE, RAVLT, GDS, MADRS. ANCOVA and Spearman's rank correlations to investigate group differences in tau and GMV, and correlations with neuropsychological test scores respectively. RESULTS: Compared to non-depressed CU participants, LLD patients showed lower GMV in temporal and anterior cingulate regions but similar tau accumulation and amyloid positivity rate. In contrast, MCI patients had significantly higher tau accumulation in all regions. Tau did not correlate with any neuropsychological test scores in LLD. CONCLUSION: Our findings suggest AD-type tau is not higher in LLD compared to non-depressed, cognitively unimpaired older adults and appears unlikely to contribute to lower gray matter volume in LLD, further underscoring the need to distinguish major depressive disorder from depressive symptoms occurring in early AD.

4.
J Nucl Med ; 2024 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-39209546

RESUMEN

Preclinical data have shown that 161Tb-labeled peptides targeting the somatostatin receptor are therapeutically more effective for peptide receptor radionuclide therapy than are their 177Lu-labeled counterparts. To further substantiate this enhanced therapeutic effect, we performed cellular dosimetry to quantify the absorbed dose to the cell nucleus and compared dose-response curves to evaluate differences in relative biological effectiveness in vitro. Methods: CA20948 cell survival was assessed after treatment with [161Tb]Tb- and [177Lu]Lu-DOTATATE (agonist) and with [161Tb]Tb- and [177Lu]Lu-DOTA-LM3 (antagonist) via a clonogenic assay. Cell binding, internalization, and dissociation assays were performed up to 7 d to acquire time-integrated activity coefficients. Separate S values for each type of particle emission (Auger/internal conversion [IC] electrons and ß- particles) were computed via Monte Carlo simulations, while considering spheric cells. Once the absorbed dose to the cell nucleus was calculated, survival curves were fitted to the appropriate linear or linear-quadratic model and corresponding relative biological effectiveness was evaluated. Results: Although the radiopeptide uptake was independent of the radionuclide, [161Tb]Tb-DOTATATE and [161Tb]Tb-DOTA-LM3 delivered a 3.6 and 3.8 times higher dose to the nucleus, respectively, than their 177Lu-labeled counterparts on saturated receptor binding. This increased nucleus-absorbed dose was mainly due to the additional emission of IC and not Auger electrons by 161Tb. When activity concentrations were considered, both [161Tb]Tb-DOTATATE and [161Tb]Tb-DOTA-LM3 showed a lower survival fraction than did labeling with 177Lu. When the absorbed dose to the nucleus was considered, no significant difference could be observed between the dose-response curves for [161Tb]Tb- and [177Lu]Lu-DOTATATE. [161Tb]Tb-DOTA-LM3 showed a linear-quadratic dose response, whereas [161Tb]Tb-DOTATATE showed only a linear dose response within the observed dose range, suggesting additional cell membrane damage by Auger electrons. Conclusion: The IC, rather than Auger, electrons emitted by 161Tb resulted in a higher absorbed dose to the cell nucleus and lower clonogenic survival for [161Tb]Tb-DOTATATE and [161Tb]Tb-DOTA-LM3 than for the 177Lu-labeled analogs. In contrast, [161Tb]Tb-DOTATATE showed no higher dose response than [177Lu]Lu-DOTATATE, whereas for [161Tb]Tb-DOTA-LM3 an additional quadratic response was observed. Because of this quadratic response, potentially caused by cell membrane damage, [161Tb]Tb-DOTA-LM3 is a more effective radiopeptide than [161Tb]Tb-DOTATATE for labeling with 161Tb.

5.
Artículo en Inglés | MEDLINE | ID: mdl-39008066

RESUMEN

The aim of this guideline is to provide recommendations for the implementation of an effective and efficient quality control (QC) programme for SPECT and PET systems in a preclinical imaging lab. These recommendations aim to strengthen the translational power of preclinical imaging results obtained using preclinical SPECT and PET. As for clinical imaging, reliability, reproducibility, and repeatability are essential when groups of animals are used in a longitudinal imaging experiment. The larger the variability of the imaging endpoint, the more animals are needed to be able to observe statistically significant differences between groups. Therefore, preclinical imaging requires quality control procedures to maintain reliability, reproducibility, and repeatability of imaging procedures, and to ensure the accuracy and precision of SPECT and PET quantification. While the Physics Committee of the European Association of Nuclear Medicine (EANM) has already published excellent procedure guidelines for Routine Quality Control Recommendations for Nuclear Medicine Instrumentation that also includes procedures for small animal PET systems, and important steps have already been made concerning preclinical quality control aspects, this new guideline provides a review and update of these previous guidelines such that guidelines are also adapted to new technological developments.

6.
J Neuroendocrinol ; 36(8): e13420, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38837825

RESUMEN

[18F]AlF-NOTA-octreotide ([18F]AlF-OC) is a promising alternative for [68Ga]Ga-DOTA-somatostatin analogs (SSAs) in positron emission tomography (PET) imaging of the somatostatin receptor (SSTR). Our aim is to assess changes in TNM staging and differences in patient management between [18F]AlF-OC PET/CT and [68Ga]Ga-DOTA-SSA PET/CT in the work-up of neuroendocrine tumor (NET) patients. Patients who underwent both [18F]AlF-OC and [68Ga]Ga-DOTA-TATE or [68Ga]Ga-DOTA-NOC PET/CT in our multicenter study (Pauwels et al., J Nucl Med.2023;63:632-638) with a NET were included for analysis. TNM staging was determined and compared for both tracers. For each patient, the blinded [68Ga]Ga-DOTA-SSA or [18F]AlF-OC PET/CT images were presented in random order at a multidisciplinary team board. The images were presented together with clinical information and compared with previous SSTR and [18F]FDG PET/CT imaging. After a consensus decision for patient management was recorded, the board was presented with the PET/CT images from the other SSTR tracer and a decision was made for the second tracer. Differences in management were classified as major if it entailed an intermodality change and minor if it led to an intramodality change. Compared with [68Ga]Ga-DOTA-SSA, the use of [18F]AlF-OC led to a change in 16/75 patients: TNM staging changes in 10/75 patients (13.3%; downstaging in 3/10, upstaging in 7/10) and differences in clinical management were seen in 10/75 patients (13.3%), leading to a major difference in 7/10 cases and a minor change in 3/10 cases. All 10 cases with a difference in patient management between both PET tracers were caused by additional lesion detection by [18F]AlF-OC. The use of [18F]AlF-OC did not impact TNM staging or clinical management in the large majority of the patients (86.7%), further validating the potential for routine clinical use of [18F]AlF-OC PET/CT as an alternative for [68Ga]Ga-DOTA-SSA PET/CT. The trial is registered under ClinicalTrials.gov identifier NCT04552847 and EudraCT 2020-000549-15.


Asunto(s)
Tumores Neuroendocrinos , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Masculino , Persona de Mediana Edad , Femenino , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/patología , Anciano , Estudios Prospectivos , Adulto , Octreótido/análogos & derivados , Radiofármacos , Somatostatina/análogos & derivados , Compuestos Organometálicos , Radioisótopos de Galio , Estadificación de Neoplasias/métodos
7.
Phys Med ; 124: 103392, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38862325

RESUMEN

The International Commission on Radiological Protection (ICRP), recently expressed concern that "a shortage of investment in training, education, research, and infrastructure seen in many sectors and countries may compromise society's ability to properly manage radiation risks" and in 2022 announced the "Vancouver call for action to strengthen expertise in radiological protection worldwide". As representatives of organisations in formal relations with ICRP, we decided to promote this position paper to declare and emphasise that strengthening the expertise in radiological protection is a collective priority for all of us.


Asunto(s)
Agencias Internacionales , Protección Radiológica , Humanos
8.
Med Phys ; 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38889361

RESUMEN

BACKGROUND: The distance traveled by the positron before annihilation with an electron, the so-called positron range, negatively effects the positron emission tomography (PET) image quality for radionuclides emitting high-energy positrons such as Gallium-68 (68Ga). PURPOSE: In this study, the effect of a tissue-independent positron range correction for Gallium-68 (68Ga-PRC) was investigated based on phantom measurements. The effect of the 68Ga-PRC was also explored in four patients. METHODS: The positron range distribution profile of 68Ga in water was generated via Monte Carlo simulation. That profile was mapped to a spatially invariant 3D convolution kernel which was incorporated in the OSEM and Q.Clear reconstruction algorithms to perform the 68Ga-PRC. In addition, each reconstruction method included point spread function (PSF) modeling and time-of-flight information. For both Fluorine-18 (18F) and 68Ga, the NEMA IQ phantom was filled with a sphere-to-background ratio of 10:1 and scanned with the GE Discovery MI 5R PET/CT system. Standard non-positron range correction (PRC) reconstructions were performed for both radionuclides, while also PRC reconstructions were performed for 68Ga. Reconstructions parameters (OSEM: number of updates, Q.Clear: beta value) were adapted to achieve similar noise levels between the corresponding reconstructions. The effect of 68Ga-PRC was assessed for both OSEM and Q.Clear reconstructions and compared to non-PRC reconstructions for 68Ga and 18F in terms of image contrast, noise, recovery coefficient (RC), and spatial resolution. For the clinical validation, 68Ga-labeled prostate-specific membrane antigen (68Ga-PSMA) and 68Ga-DOTATOC PET scans were included of two patients each. For each PET scan, patients were injected with 1.5 MBq/kg of 68Ga-PSMA or 68Ga-DOTATOC and the contrast-to-noise ratio (CNR) was calculated and compared to the non-PRC reconstructions. RESULTS: For OSEM reconstructions, including the 68Ga-PRC improved the RC by 9.4% (3.7%-19.3%) and spatial resolution by 21.7% (4.6 mm vs. 3.6 mm) for similar noise levels. For Q.Clear reconstructions, 68Ga-PRC modeling improved the RC by 6.7% (2.8%-10.5%) and spatial resolution by 15.3% (5.9 mm vs. 5.0 mm) while obtaining similar noise levels. In the patient data, the use of 68Ga-PRC enhanced the CNR by 13.2%. CONCLUSIONS: Including 68Ga-PRC in the PET reconstruction enhanced the image quality of 68Ga PET data compared to the standard non-PRC reconstructions for similar noise levels. Limited patient results also supported this improvement.

9.
EJNMMI Phys ; 11(1): 52, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38937408

RESUMEN

BACKGROUND: Although the importance of quantitative SPECT has increased tremendously due to newly developed therapeutic radiopharmaceuticals, there are still no accreditation programs to harmonize SPECT imaging. Work is currently underway to develop an accreditation for quantitative 177Lu SPECT/CT. The aim of this study is to verify whether the positioning of the spheres within the phantom has an influence on the recovery and thus needs to be considered in SPECT harmonization. In addition, the effects of these recovery coefficients on a potential partial volume correction as well as absorbed-dose estimates are investigated. METHODS: Using a low-dose CT of a SPECT/CT acquisition, a computerized version of the NEMA body phantom was created using a semi-automatic threshold-based method. Based on the mass-density map, the detector orbit, and the sphere centers, realistic SPECT acquisitions of all possible 720 sphere configurations of both the PET and the SPECT versions of the NEMA Body Phantom were generated using Monte Carlo simulations. SPECT reconstructions with different numbers of updates were performed without (CASToR) and with resolution modeling (STIR). Recovery coefficients were calculated for all permutations, reconstruction methods, and phantoms, and their dependence on the sphere positioning was investigated. Finally, the simulation-based findings were validated using SPECT/CT acquisitions of six different sphere configurations. RESULTS: Our analysis shows that sphere positioning has a significant impact on the recovery for both of the reconstruction methods and the phantom type. Although resolution modeling resulted in significantly higher recovery, the relative variation in recovery within the 720 permutations was even larger. When examining the extreme values of the recovery, reconstructions without resolution modeling were influenced primarily by the sphere position, while with resolution modeling the volume of the two adjacent spheres had a larger influence. The SPECT measurements confirmed these observations, and the recovery curves showed good overall agreement with the simulated data. CONCLUSION: Our study shows that sphere positioning has a significant impact on the recovery obtained in NEMA sphere phantom measurements and should therefore be considered in a future SPECT accreditation. Furthermore, the single-measurement method normally performed for PVC should be reconsidered to account for the position dependency.

11.
Transl Psychiatry ; 14(1): 145, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485934

RESUMEN

Late-life depression has been consistently associated with lower gray matter volume, the origin of which remains largely unexplained. Recent in-vivo PET findings in early-onset depression and Alzheimer's Disease suggest that synaptic deficits contribute to the pathophysiology of these disorders and may therefore contribute to lower gray matter volume in late-life depression. Here, we investigate synaptic density in vivo for the first time in late-life depression using the synaptic vesicle glycoprotein 2A receptor radioligand 11C-UCB-J. We included 24 currently depressed adults with late-life depression (73.0 ± 6.2 years, 16 female, geriatric depression scale = 19.5 ± 6.8) and 36 age- and gender-matched healthy controls (70.4 ± 6.2 years, 21 female, geriatric depression scale = 2.7 ± 2.9) that underwent simultaneous 11C-UCB-J positron emission tomography (PET) and 3D T1- and T2-FLAIR weighted magnetic resonance (MR) imaging on a 3-tesla PET-MR scanner. We used analyses of variance to test for 11C-UCB-J binding and gray matter volumes differences in regions implicated in depression. The late-life depression group showed a trend in lower gray matter volumes in the hippocampus (p = 0.04), mesial temporal (p = 0.02) and prefrontal cortex (p = 0.02) compared to healthy control group without surviving correction for multiple comparison. However, no group differences in 11C-UCB-J binding were found in these regions nor were any associations between 11C-UCB-J and depressive symptoms. Our data suggests that, in contrast to Alzheimer's Disease, lower gray matter volume in late-life depression is not associated with synaptic density changes. From a therapeutic standpoint, preserved synaptic density in late-life depression may be an encouraging finding.


Asunto(s)
Enfermedad de Alzheimer , Depresión , Humanos , Femenino , Anciano , Depresión/diagnóstico por imagen , Enfermedad de Alzheimer/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Hipocampo/diagnóstico por imagen , Corteza Prefrontal
12.
EJNMMI Phys ; 11(1): 29, 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38499797

RESUMEN

PURPOSE: Next-generation SPECT/CT systems with CdZnTe (CZT) digital detectors in a ring-like setup are emerging to perform quantitative Lu-177 SPECT imaging in clinical routine. It is essential to assess how the shorter acquisition time might affect the image quality and uncertainty on the mean absorbed dose of the tumors and organs at risk compared to a conventional system. METHODS: A NEMA Image Quality phantom was scanned with a 3D CZT SPECT/CT system (Veriton, by Spectrum Dynamics) using 6 min per bed position and with a conventional SPECT/CT system (Symbia T16, by Siemens) using 16 min per bed position. The sphere-to-background ratio was 12:1 and the background activity concentration ranged from 0.52 to 0.06 MBq/mL. A clinical reconstruction protocol for dosimetry purposes was determined for both systems by maximizing the sphere-to-background ratio while keeping the coefficient of variation of the background as low as possible. The corresponding image resolution was determined by the matching filter method and used for a dose uncertainty assessment of both systems following an established uncertainty model.. RESULTS: The optimized iterative reconstruction protocol included scatter and attenuation correction for both systems and detector response modeling for the Siemens system. For the 3D CZT system, 6 iterations and 8 subsets were combined with a Gaussian post-filter of 3 mm Full Width Half Maximum (FWHM) for post-smoothing. For the conventional system, 16 iterations and 16 subsets were applied with a Gaussian post-smoothing filter of 1 mm FWHM. For these protocols, the sphere-to-background ratio was 18.5% closer to the true ratio for the conventional system compared to the 3D CZT system when considering the four largest spheres. Meanwhile, the background coefficient of variation was very similar for both systems. These protocols resulted in SPECT image resolution of 14.8 mm and 13.6 mm for the 3D CZT and conventional system respectively. Based on these resolution estimates, a 50% dose uncertainty corresponded to a lesion volume of 28 mL for the conventional system and a lesion volume of 33 mL for the 3D CZT system. CONCLUSIONS: An optimized reconstruction protocol for a Veriton system with 6 min of acquisition time per bed position resulted in slightly higher dose uncertainties than a conventional Symbia system using 16 min of acquisition time per bed position. Therefore, a 3D CZT SPECT/CT allows to significantly reduce the acquisition times with only a very limited impact on dose uncertainties such that quantitative Lu-177 SPECT/CT imaging becomes much more accessible for treatment concurrent dosimetry. Nevertheless, the uncertainty of SPECT-based dose estimates remains high.

13.
Nucl Med Biol ; 132-133: 108906, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38518400

RESUMEN

BACKGROUND: The C-X-C chemokine receptor type 4 (CXCR4) is overexpressed in many cancers, e.g. multiple myeloma and acute leukemia, yet solely [68Ga]PentixaFor is used for clinical PET imaging. The aim of this study was to develop and assess a second generation Al18F-labeled D-amino acid peptide based on the viral macrophage inflammatory protein II for CXCR4 targeted molecular imaging. METHODS: We designed a library of monomer and multimer constructs and evaluated their binding affinity for human and mouse CXCR4. Based on these results, we selected the best vector molecule for development of an Al18F-labeled ligand, [18F]AlF-NOTA-2xDV1(c11sc12s), which was further evaluated in a cell-based binding assay to assess its binding properties and specificity for CXCR4. Next, pharmacokinetics and tumor uptake of [18F]AlF-NOTA-2xDV1(c11sc12s) were evaluated in naïve mice and mice with xenografts derived from U87.CXCR4 cells. Finally, we performed an imaging study in a non-human primate to assess the in vivo distribution of this novel radioligand in a species closely related to humans. RESULTS: The lead ligand AlF-NOTA-2xDV1(c11sc12s) showed six-fold higher affinity for human CXCR4 compared to Ga-Pentixafor. The corresponding radiotracer was obtained in a good radiochemical yield of 40.1 ± 13.5 % (n = 4) and apparent molar activity of 20.4 ± 3.3 MBq/nmol (n = 4) after optimization. In U87.CD4.CXCR4 cell binding assays, the total bound fraction of [18F]AlF-NOTA-(2×)DV1(c11sc12s) was 32.4 ± 1.8 %. This fraction could be reduced by 82.5 % in the presence of 75 µM AMD3100. In naïve mice, [18F]AlF-NOTA-2xDV1(c11sc12s) accumulated in organs expressing mouse CXCR4, e.g. the liver (SUVmean (mean standardized uptake value) 75 min p.i. 11.7 ± 0.6), which was blockable by co-injecting AMD3100 (5 mg/kg). In U87.CXCR4 xenografted tumor mice, the tumor uptake of [18F]AlF-NOTA-2xDV1(c11sc12s) remained low (SUVmean 0.5 ± 0.1), but was reduced by co-administration of AMD3100. Surprisingly, [18F]AlF-NOTA-2xDV1(c11sc12s) exhibited a similar biodistribution in a non-human primate as in mice indicating off-target binding of [18F]AlF-NOTA-2xDV1(c11sc12s) in liver tissue. We confirmed that [18F]AlF-NOTA-2xDV1(c11sc12s) is taken up by hepatocytes using in vitro studies and that the uptake can be blocked with AMD3100 and rifampicin, a potent organic anion-transporting-polypeptide (OATP)1B1 and OATP1B3 inhibitor. CONCLUSION: The second generation D-peptide AlF-NOTA-2xDV1(c11sc12s) showed high affinity for human CXCR4 and the corresponding radiotracer was produced in good radiochemical yields. However, [18F]AlF-NOTA-2xDV1(c11sc12s) is not specific for CXCR4 and is also a substrate for OATP1B1 and/or OATP1B3, known to mediate hepatic uptake. Therefore, D-amino acid peptides, based on the viral macrophage inflammatory protein II, are not the prefered vector molecule for the development of CXCR4 targeting molecular imaging tools.


Asunto(s)
Radioisótopos de Flúor , Receptores CXCR4 , Receptores CXCR4/metabolismo , Animales , Ratones , Humanos , Radioisótopos de Flúor/química , Péptidos/química , Péptidos/farmacocinética , Línea Celular Tumoral , Distribución Tisular , Marcaje Isotópico , Imagen Molecular/métodos , Tomografía de Emisión de Positrones/métodos , Radioquímica
14.
Theranostics ; 14(4): 1720-1743, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38389843

RESUMEN

Terbium features four clinically interesting radionuclides for application in nuclear medicine: terbium-149, terbium-152, terbium-155, and terbium-161. Their identical chemical properties enable the synthesis of radiopharmaceuticals with the same pharmacokinetic character, while their distinctive decay characteristics make them valuable for both imaging and therapeutic applications. In particular, terbium-152 and terbium-155 are useful candidates for positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging, respectively; whereas terbium-149 and terbium-161 find application in α- and ß--/Auger electron therapy, respectively. This unique characteristic makes the terbium family ideal for the "matched-pair" principle of theranostics. In this review, the advantages and challenges of terbium-based radiopharmaceuticals are discussed, covering the entire chain from radionuclide production to bedside administration. It elaborates on the fundamental properties of terbium, the production routes of the four interesting radionuclides and gives an overview of the available bifunctional chelators. Finally, we discuss the preclinical and clinical studies as well as the prospects of this promising development in nuclear medicine.


Asunto(s)
Medicina Nuclear , Terbio , Medicina de Precisión , Radiofármacos/uso terapéutico , Radioisótopos/uso terapéutico , Tomografía de Emisión de Positrones
15.
J Neurotrauma ; 41(3-4): 420-429, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38038357

RESUMEN

Epidemiological studies have identified prior traumatic brain injury (TBI) as a risk factor for developing Alzheimer's disease (AD). Neurofibrillary tangles (NFTs) are common to AD and chronic traumatic encephalopathy following repetitive mild TBI. However, it is unclear if a single TBI is sufficient to cause accumulation of NFTs. We performed a [18F]MK-6240 positron emission tomography (PET) imaging study to assess NFTs in patients who had sustained a single TBI at least 2 years prior to study inclusion. Fourteen TBI patients (49 ± 20 years; 5 M/9 F; 8 moderate-severe, 1 mild-probable, 5 symptomatic-possible TBI) and 40 demographically similar controls (57 ± 19 years; 19 M/21 F) underwent simultaneous [18F]MK-6240 PET and magnetic resonance imaging (MRI) as well as neuropsychological assessment including the Cambridge Neuropsychological Test Automated Battery (CANTAB). A region-based voxelwise partial volume correction was applied, using parcels obtained by FreeSurfer v6.0, and standardized uptake value ratios (SUVR) were calculated relative to the cerebellar gray matter. Group differences were assessed on both a voxel- and a volume-of-interest-based level and correlations of [18F]MK-6240 SUVR with time since injury as well as with clinical outcomes were calculated. Visual assessment of TBI images did not show global or focal increases in tracer uptake in any subject. On a group level, [18F]MK-6240 SUVR was not significantly different in patients versus controls or between subgroups of moderate-severe TBI versus less severe TBI. Within the TBI group, One Touch Stockings problem solving and spatial working memory (executive function), reaction time (attention), and Mini-Mental State Examination (MMSE) (global cognition) were associated with [18F]MK-6240 SUVR. We found no group-based increase of [18F]MK-6240 brain uptake in patients scanned at least 2 years after a single TBI compared with healthy volunteers, which suggests that no NFTs are building up in the first years after a single TBI. Nonetheless, correlations with cognitive outcomes were found that warrant further investigation.


Asunto(s)
Enfermedad de Alzheimer , Conmoción Encefálica , Lesiones Traumáticas del Encéfalo , Isoquinolinas , Humanos , Tomografía de Emisión de Positrones , Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Lesiones Traumáticas del Encéfalo/patología , Encéfalo/patología , Enfermedad de Alzheimer/patología , Conmoción Encefálica/patología , Proteínas tau/metabolismo
16.
Ther Adv Med Oncol ; 15: 17588359231189133, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37885461

RESUMEN

Background: Somatostatin receptor (SSTR) positron emission tomography (PET) is a cornerstone of neuroendocrine tumor (NET) management. Hybrid PET/magnetic resonance imaging (MRI) is now available for NET-imaging, next to PET/computed tomography (CT). Objectives: To determine whether CT or MRI is the best hybrid partner for [68Ga]Ga-DOTATATE PET. Design: Monocentric, prospective study. Methods: Patients received a same-day [68Ga]Ga-DOTATATE PET/CT and subsequent PET/MRI, for suspicion of NET, (re)staging or peptide receptor radionuclide therapy-selection. The union (PETunion) of malignant lesions detected on PETCT and PETMRI was the reference standard. Concordance of detection of malignant lesions in an organ was measured between PETunion and CT and PETunion and MRI. Seven bins were used to categorize the number of malignant lesions, containing following ordinal variables: 0, 1, 2-5, 6-10, 11-20, >20 countable and diffuse/uncountable. The difference in number of malignant lesions was obtained as the difference in bin level ('Δbin') between PETunion and CT and PETunion and MRI with a Δbin closer to zero implying a higher concordance rate. Results: Twenty-nine patients were included. Primary tumors included 17 gastroenteropancreatic-NETs, 1 colon neuroendocrine carcinoma, 7 lung-NETs and 2 meningiomas. Patient level concordance with PETunion was 96% for MRI and 67% for CT (p = 0.039). Organ level concordance with PETunion was 74% for MRI and 40% for CT (p < 0.0001). In bone, there was a higher concordance rate for MRI compared to CT, 92% and 33%, respectively (p = 0.016). Overall, a mean Δbin of 0.5 ± 1.1 for PETunion/MRI and 1.4 ± 1.2 for PETunion/CT (p < 0.0001) was noted. In liver, a mean Δbin of 0.0 ± 1.1 for PETunion/MRI and 1.7 ± 1.2 for PETunion/CT was observed (p = 0.0078). In bone, a mean Δbin closer to zero was observed for PETunion/MRI compared to PETunion/CT, 0.6 ± 1.4 and 2.0 ± 1.5, respectively (p = 0.0098). Conclusions: Compared to SSTR PET/CT, SSTR PET/MRI had a higher patient and organ level concordance for malignant tumoral involvement and number of malignant lesions, with a clear added value in bone and liver specifically.

18.
Front Neuroimaging ; 2: 1115965, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37645694

RESUMEN

With the increasing success of mapping brain networks and availability of multiple MR- and PET-based connectivity measures, the need for novel methodologies to unravel the structure and function of the brain at multiple spatial and temporal scales is emerging. Therefore, in this work, we used hybrid PET-MR data of healthy volunteers (n = 67) to identify multiplex core nodes in the human brain. First, monoplex networks of structural, functional and metabolic connectivity were constructed, and consequently combined into a multiplex SC-FC-MC network by linking the same nodes categorically across layers. Taking into account the multiplex nature using a tensorial approach, we identified a set of core nodes in this multiplex network based on a combination of eigentensor centrality and overlapping degree. We introduced a coreness coefficient, which mitigates the effect of modeling parameters to obtain robust results. The proposed methodology was applied onto young and elderly healthy volunteers, where differences observed in the monoplex networks persisted in the multiplex as well. The multiplex core showed a decreased contribution to the default mode and salience network, while an increased contribution to the dorsal attention and somatosensory network was observed in the elderly population. Moreover, a clear distinction in eigentensor centrality was found between young and elderly healthy volunteers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA