Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Geophys Res Atmos ; 125(8): e2019JD031433, 2020 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-32714723

RESUMEN

An analysis is presented of electric fields in thunderclouds using a recently proposed method based on measuring radio emission from extensive air shower events during thunderstorm conditions. This method can be regarded as a tomography of thunderclouds using cosmic rays as probes. The data cover the period from December 2011 till August 2014. We have developed an improved fitting procedure to be able to analyze the data. Our measurements show evidence for the main negative-charge layer near the -10° isotherm. This we have seen for a winter as well as for a summer cloud where multiple events pass through the same cloud and also the vertical component of the electric field could be reconstructed. On the day of measurement of some cosmic-ray events showing evidence for strong fields, no lightning activity was detected within 100 km distance. For the winter events, the top heights were between 5 and 6 km, while in the summer, typical top heights of 9 km were seen. Large horizontal components in excess of 70 kV/m of the electric fields are observed in the middle and top layers.

2.
Science ; 315(5815): 1097, 2007 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-17322054

RESUMEN

By using a combination of radio frequency time-of-arrival and interferometer measurements, we observed a sequence of lightning and electrical activity during one of Mount St. Augustine's eruptions. The observations indicate that the electrical activity had two modes or phases. First, there was an explosive phase in which the ejecta from the explosion appeared to be highly charged upon exiting the volcano, resulting in numerous apparently disorganized discharges and some simple lightning. The net charge exiting the volcano appears to have been positive. The second phase, which followed the most energetic explosion, produced conventional-type discharges that occurred within plume. Although the plume cloud was undoubtedly charged as a result of the explosion itself, the fact that the lightning onset was delayed and continued after and well downwind of the eruption indicates that in situ charging of some kind was occurring, presumably similar in some respects to that which occurs in normal thunderstorms.

3.
Science ; 201(4350): 9-16, 1978 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-17777737

RESUMEN

A lightning flash that struck the 150-meter weather tower at Kennedy Space Center was studied by several research groups using varioul techniques. The flash had unusually large peak currents and a stepped leader of relatively short duration. The charged regions neutralized by the three return strokes were located within a horizontal layer between heights of about 6 and 8 kilometers, where environmental temperatures were about -10 degrees to -20 degrees C. The charge source for the first return stroke coincided with a vertical shaft of precipitation inferred to have been graupel or hail. Charge sources for subsequent strokes were near the edge of the detectable precipitation echo. The overall channel length was about 10 kilometers. A Vertically oriented intracloud discharge occurred after the three return strokes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA