Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 247
Filtrar
Más filtros

Base de datos
Tipo del documento
Intervalo de año de publicación
1.
Eur Urol ; 2024 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-39379236

RESUMEN

BACKGROUND AND OBJECTIVE: Delivering radiotherapy to the bladder is challenging as it is a mobile, deformable structure. Dose-escalated adaptive image-guided radiotherapy could improve outcomes. RAIDER aimed to demonstrate the safety of such a schedule. METHODS: RAIDER is an international phase 2 noncomparative randomised controlled trial (ISRCTN26779187). Patients with unifocal T2-T4a urothelial bladder cancer were randomised (1:1:2) to standard whole bladder radiotherapy (WBRT), standard-dose adaptive radiotherapy (SART), or dose-escalated adaptive radiotherapy (DART). Two fractionation (f) schedules recruited independently. WBRT and SART dose was 55 Gy/20f or 64 Gy/32f, and DART dose was 60 Gy/20f or 70 Gy/32f. For SART and DART, a radiotherapy plan (small, medium, or large) was chosen daily. The primary endpoint was the proportion of patients with radiotherapy-related late Common Terminology Criteria for Adverse Events grade ≥3 toxicity; the trial was designed to rule out >20% toxicity with DART. KEY FINDINGS AND LIMITATIONS: A total of 345 patients were randomised between October 2015 and April 2020: 41/46 WBRT, 41/46 SART, and 81/90 DART patients in the 20f/32f cohorts, respectively. The median age was 72/73 yr; 78%/85% had T2 tumours, 46%/52% had neoadjuvant chemotherapy, and 70%/71% had radiosensitising therapy. The median follow-up was 42.1/38.2 mo. Sixty-six of 77 (86%) 20f and 74 of 82 (90%) 32f participants planned for DART met the mandatory medium plan dose constraints. Radiotherapy-related grade ≥3 toxicity was reported in one of 58 patients (90% confidence interval [CI] 0.1, 7.9) with 20f DART and zero of 56 patients with 32f DART. Two-year overall survival was 77% (95% CI 69, 82) for WBRT + SART and 80% (95% CI 73, 85) for DART (hazard ratio = 0.84, 95% CI 0.59, 1.21, p = 0.4). Thirteen of 345 (3.8%) participants had salvage cystectomy. CONCLUSIONS AND CLINICAL IMPLICATIONS: Grade ≥3 late toxicity was low. DART was safe and feasible to deliver, meeting preset toxicity thresholds. Disease-related outcomes are promising for dose-escalated treatments, with a low salvage cystectomy rate and overall survival similar to that seen in cystectomy cohorts.

3.
Phys Med ; 125: 104490, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39142028

RESUMEN

PURPOSE: Lattice radiation therapy (LRT) alternates regions of high and low doses inside the tumour. Whilst this technique reported positive results in tumour size reduction, optimal lattice parameters are still unknown. We introduce an automated LRT planning method personalised to tumour shape and designed to allow investigation of lattice geometry. METHODS: Patients with retroperitoneal sarcoma were considered for inclusion. Automation was performed with the Eclipse Scripting Application Interface (v16, Varian Medical Systems, Palo Alto). By iterating over vertex size (V) and centre-to-centre distance (D), vertices were segmented within the gross tumour volume (GTV) in an alternating square pattern. Iterations stopped when the number of inserted vertices was contained between a prespecified lower and upper bound. Forty sets of lattices were considered, produced by varying V and D in five lower/upper bound pairs. Best-scoring sets were determined with a score favouring the maximization of GTV dose uniformity and heterogeneity whilst minimizing the maximum dose to organs at risk. RESULTS: Fifty patients with tumour volumes between 150 cm3 and 10,000 cm3 were included. Best-scoring sets were characterised by a low number of vertices (<15). Based on the best-scoring set, the predicted parameters to use for new patients were V = 0.19 (GTV volume)1/3 and D = 2V, in centimetres. The number of vertices (N) to insert in the GTV can be estimated with N ≤ (24 × 3% GTV volume)/(4πV3). CONCLUSIONS: The automated LRT treatment planning personalised to tumour size allows investigation of lattice geometry over a large range of GTV volumes.


Asunto(s)
Automatización , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Medicina de Precisión , Sarcoma/radioterapia , Sarcoma/diagnóstico por imagen , Dosificación Radioterapéutica , Órganos en Riesgo/efectos de la radiación , Neoplasias Retroperitoneales/radioterapia , Neoplasias Retroperitoneales/diagnóstico por imagen , Neoplasias Retroperitoneales/patología
4.
Phys Med Biol ; 69(18)2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39159668

RESUMEN

Objective.Upright positioning has seen a surge in interest as a means to reduce radiotherapy (RT) cost, improve patient comfort, and, in selected cases, benefit treatment quality. In particle therapy (PT) in particular, eliminating the need for a gantry can present massive cost and facility footprint reduction. This review discusses the opportunities of upright RT in perspective of the open challenges.Approach.The clinical, technical, and workflow challenges that come with the upright posture have been extracted from an extensive literature review, and the current state of the art was collected in a synergistic perspective from photon and particle therapy. Considerations on future developments and opportunities are provided.Main results.Modern image guidance is paramount to upright RT, but it is not clear which modalities are essential to acquire in upright posture. Using upright MRI or upright CT, anatomical differences between upright/recumbent postures have been observed for nearly all body sites. Patient alignment similar to recumbent positioning was achieved in small patient/volunteer cohorts with prototype upright positioning systems. Possible clinical advantages, such as reduced breathing motion in upright position, have been reported, but limited cohort sizes prevent resilient conclusions on the treatment impact. Redesign of RT equipment for upright positioning, such as immobilization accessories for various body regions, is necessary, where several innovations were recently presented. Few clinical studies in upright PT have already reported promising outcomes for head&neck patients.Significance.With more evidence for benefits of upright RT emerging, several centers worldwide, particularly in PT, are installing upright positioning devices or have commenced upright treatment. Still, many challenges and open questions remain to be addressed to embed upright positioning firmly in the modern RT landscape. Guidelines, professionals trained in upright patient positioning, and large-scale clinical studies are required to bring upright RT to fruition.


Asunto(s)
Posicionamiento del Paciente , Humanos , Radioterapia/métodos , Radioterapia/instrumentación
5.
Comput Med Imaging Graph ; 116: 102403, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38878632

RESUMEN

BACKGROUND AND OBJECTIVES: Bio-medical image segmentation models typically attempt to predict one segmentation that resembles a ground-truth structure as closely as possible. However, as medical images are not perfect representations of anatomy, obtaining this ground truth is not possible. A surrogate commonly used is to have multiple expert observers define the same structure for a dataset. When multiple observers define the same structure on the same image there can be significant differences depending on the structure, image quality/modality and the region being defined. It is often desirable to estimate this type of aleatoric uncertainty in a segmentation model to help understand the region in which the true structure is likely to be positioned. Furthermore, obtaining these datasets is resource intensive so training such models using limited data may be required. With a small dataset size, differing patient anatomy is likely not well represented causing epistemic uncertainty which should also be estimated so it can be determined for which cases the model is effective or not. METHODS: We use a 3D probabilistic U-Net to train a model from which several segmentations can be sampled to estimate the range of uncertainty seen between multiple observers. To ensure that regions where observers disagree most are emphasised in model training, we expand the Generalised Evidence Lower Bound (ELBO) with a Constrained Optimisation (GECO) loss function with an additional contour loss term to give attention to this region. Ensemble and Monte-Carlo dropout (MCDO) uncertainty quantification methods are used during inference to estimate model confidence on an unseen case. We apply our methodology to two radiotherapy clinical trial datasets, a gastric cancer trial (TOPGEAR, TROG 08.08) and a post-prostatectomy prostate cancer trial (RAVES, TROG 08.03). Each dataset contains only 10 cases each for model development to segment the clinical target volume (CTV) which was defined by multiple observers on each case. An additional 50 cases are available as a hold-out dataset for each trial which had only one observer define the CTV structure on each case. Up to 50 samples were generated using the probabilistic model for each case in the hold-out dataset. To assess performance, each manually defined structure was matched to the closest matching sampled segmentation based on commonly used metrics. RESULTS: The TOPGEAR CTV model achieved a Dice Similarity Coefficient (DSC) and Surface DSC (sDSC) of 0.7 and 0.43 respectively with the RAVES model achieving 0.75 and 0.71 respectively. Segmentation quality across cases in the hold-out datasets was variable however both the ensemble and MCDO uncertainty estimation approaches were able to accurately estimate model confidence with a p-value < 0.001 for both TOPGEAR and RAVES when comparing the DSC using the Pearson correlation coefficient. CONCLUSIONS: We demonstrated that training auto-segmentation models which can estimate aleatoric and epistemic uncertainty using limited datasets is possible. Having the model estimate prediction confidence is important to understand for which unseen cases a model is likely to be useful.


Asunto(s)
Imagenología Tridimensional , Humanos , Incertidumbre , Imagenología Tridimensional/métodos , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/diagnóstico por imagen , Masculino , Ensayos Clínicos como Asunto , Conjuntos de Datos como Asunto , Algoritmos , Tomografía Computarizada por Rayos X
6.
Pract Radiat Oncol ; 2024 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-38705233

RESUMEN

PURPOSE: Functional lung avoidance (FLA) radiation therapy is an evolving field. The aim of FLA planning is to reduce dose to areas of functioning lung, with comparable target coverage and dose to organs at risk. Multicriteria optimization (MCO) is a planning tool that may assist with FLA planning. This study assessed the feasibility of using MCO to adapt radiation therapy plans to avoid functional regions of lung that were identified using a 68Ga-4D-V/Q positron emission tomography/computed tomography. METHODS AND MATERIALS: A prospective clinical trial U1111-1138-4421 was performed in which patients had a 68Ga-4D-V/Q positron emission tomography/computed tomography before radiation treatment. Of the 72 patients enrolled in this trial, 38 patients had stage III non-small cell lung cancer and were eligible for selection into this planning study. Functional lung target volumes HF lung (highly functioning lung) and F lung (functional lung) were defined using the ventilated and perfused lung. Using knowledge-based planning, a baseline anatomic plan was created, and then a functional adapted plan was generated using multicriteria optimization. The primary aim was to spare dose to HF lung. Using the MCO tools, a clinician selected the final FLA plan. Dose to functional lung, target volumes, organs at risk and measures of plan quality were compared using standard statistical methods. RESULTS: The HF lung volume was successfully spared in all patients. The F lung volume was successfully spared in 36 of the 38 patients. There were no clinically significant differences in dose to anatomically defined organs at risk. There were differences in the planning target volume near maximum and minimum doses. Across the entire population, there was a statistically significant reduction in the functional mean lung dose but not in the functional volume receiving 20 Gy. All trade-off decisions were made by the clinician. CONCLUSIONS: Using MCO for FLA was achievable but did result in changes to planning target volume coverage. A distinct advantage in using MCO was that all decisions regarding the cost and benefits of FLA could be made in real time.

7.
Int J Radiat Oncol Biol Phys ; 120(3): 648-654, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-38679212

RESUMEN

PURPOSE: Stereotactic ablative body radiotherapy (SABR) is a novel option to treat primary renal cell carcinoma. However, a high radiation dose may be received by the treated kidney, which may affect its function posttreatment. This study investigates the dose-effect relationship of kidney SABR with posttreatment renal function. METHODS AND MATERIALS: This was a prespecified secondary endpoint of the multicenter FASTRACK II (Focal Ablative STereotactic RAdiotherapy for Cancers of the Kidney phase II) clinical trial (National Clinical Trial 02613819). Patients received either 26 Gy in a single fraction (SF) for tumors with a maximal diameter of 4 cm or less or 42 Gy in 3 fractions (multifraction [MF]) for larger tumors. To determine renal function change, 99mTc-dimercaptosuccinic acid (DMSA) single-photon emission computed tomography/computed tomography (SPECT/CT) scans were acquired, and the glomerular filtration rate was estimated at baseline, 12, and 24 months posttreatment. Imaging data sets were rigidly registered to the planning CT where kidneys were segmented to calculate dose-response curves. RESULTS: From 71 enrolled patients, 36 (51%) and 26 (37%) patients were included in this study based on availability of posttreatment data at 12 and 24 months, respectively. The ipsilateral kidney glomerular filtration rate decreased from baseline by 42% and 39% in the SF cohort and by 45% and 62% in the MF cohort, at 12 and 24 months, respectively (P < .03). The loss in renal function was 3.6%/Gy ± 0.8%/Gy and 4.5%/Gy ± 1.0%/Gy in the SF cohort and 1.7%/Gy ± 0.1%/Gy and 1.7%/Gy ± 0.2%/Gy in the MF cohort at 12 and 24 months, respectively. The major loss in renal function occurred in high-dose regions, where dose-response curves converged to a plateau. CONCLUSIONS: For the first time in a multicenter study, the dose-effect relationship at 12 and 24 months post-SABR treatment for primary renal cell carcinoma was quantified. Kidney function reduces linearly with dose up to 100 Gy BED3.


Asunto(s)
Carcinoma de Células Renales , Relación Dosis-Respuesta en la Radiación , Tasa de Filtración Glomerular , Neoplasias Renales , Riñón , Radiocirugia , Humanos , Carcinoma de Células Renales/radioterapia , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Carcinoma de Células Renales/cirugía , Neoplasias Renales/radioterapia , Neoplasias Renales/diagnóstico por imagen , Masculino , Radiocirugia/efectos adversos , Radiocirugia/métodos , Femenino , Riñón/efectos de la radiación , Riñón/diagnóstico por imagen , Riñón/fisiopatología , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único , Radiofármacos , Adulto , Ácido Dimercaptosuccínico de Tecnecio Tc 99m , Fraccionamiento de la Dosis de Radiación
9.
Radiother Oncol ; 194: 110185, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38412905

RESUMEN

BACKGROUND: Locally advanced, bulky, unresectable sarcomas cause significant tumour mass effects, leading to burdensome symptoms. We have developed a novel Partially Ablative Body Radiotherapy (PABR) technique that delivers a high, ablative dose to the tumour core and a low, palliative dose to its periphery aiming to increase overall tumour response without significantly increasing treatment toxicity. AIM: This study aims to report the safety and oncologic outcomes of PABR in patients with bulky, unresectable sarcomas. METHODS AND MATERIALS: A total of 18 patients with histologically proven sarcoma treated with PABR from January 2020 to October 2023 were retrospectively reviewed. The primary endpoints were symptomatic and structural response rates. Secondary endpoints were overall survival, freedom from local progression, freedom from distant progression, and acute and late toxicity rates. RESULTS: All patients had tumours ≥5 cm with a median tumour volume of 985 cc, and the most common symptom was pain. The median age is 72.5 years and 44.5 % were ECOG 2-3. The most common regimen used was 20 Gy in 5 fractions with an intratumoral boost dose of 50 Gy (83.3 %). After a median follow-up of 11 months, 88.9 % of patients exhibited a partial response with a mean absolute tumour volume reduction of 49.5 %. All symptomatic patients experienced symptom improvement. One-year OS, FFLP and FFDP were 61 %, 83.3 % and 34.8 %, respectively. There were no grade 3 or higher toxicities. CONCLUSION: PABR for bulky, unresectable sarcomas appears to be safe and may provide good symptomatic response, tumour debulking, and local control. Further study is underway.


Asunto(s)
Cuidados Paliativos , Sarcoma , Humanos , Sarcoma/radioterapia , Sarcoma/patología , Sarcoma/cirugía , Sarcoma/mortalidad , Masculino , Cuidados Paliativos/métodos , Femenino , Anciano , Estudios Retrospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Carga Tumoral , Adulto , Dosificación Radioterapéutica
10.
J Appl Clin Med Phys ; 25(6): e14276, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38414322

RESUMEN

PURPOSE: Patient-specific quality assurance (PSQA) for vertebra stereotactic body radiation therapy (SBRT) presents challenges due to highly modulated small fields with high-dose gradients between the target and spinal cord. This study aims to explore the use of the SRS MapCHECK® (SRSMC) for vertebra SBRT PSQA. METHODS: Twenty vertebra SBRT treatment plans including prescriptions 20 Gy/1 fraction and 24 Gy/2 fractions were selected for each of Millennium (M)-Multileaf Collimator (MLC), and high-definition (HD)-MLC. All 40 plans were measured using Gafchromic EBT3 film (film) and SRSMC, using the StereoPHAN phantom. Plan complexity was assessed using modulation complexity score (MCS), edge metric (EM) (mm-1), modulation factor (MU/cGy), and average leaf pair opening (ALPO) (mm) and its correlation with gamma-pass rate was investigated. The high dose gradient between the target and the spinal cord was analyzed for film and SRSMC and compared against the treatment planning system (TPS). Applying the methodology proposed by AAPM TG-218, action and tolerance values specific to the SRSMC for vertebra SBRT were determined for ß values ranging from 5 to 8. RESULTS: Film and SRSMC gamma-pass rates showed no correlation (p > 0.05). A moderate negative correlation (R = -0.57, p = 0.01) is present between EM and SRSMC 3%/1 mm gamma-pass rate for HD-MLC plans. Both film and SRSMC accurately measured high dose gradients between the target and the spinal cord (R2 > 0.86, p ≤ 0.05). Notably, dose-gradient of HD-MLC plans is 22% steeper and has a smaller standard deviation to M-MLC plans (p ≤ 0.05). Applying TG-218, the film tolerance limit was 96% with action limit 95% for 5%/1 mm (ß = 6) and for the SRSMC tolerance limit was 97% with an action limit of 96% for 4%/1 mm (ß = 6). CONCLUSION: Our findings suggest that universal TG-218 limits may not be suitable for vertebra SBRT PSQA. This study demonstrates that SRSMC is a viable tool for vertebra SBRT PSQA, supported by TG-218 implementation of process-based tolerance and action limits.


Asunto(s)
Órganos en Riesgo , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud , Radiocirugia , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Garantía de la Calidad de Atención de Salud/normas , Órganos en Riesgo/efectos de la radiación , Neoplasias de la Columna Vertebral/cirugía , Neoplasias de la Columna Vertebral/radioterapia
11.
J Med Radiat Sci ; 71 Suppl 2: 82-89, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38305062

RESUMEN

Proton-beam therapy (PBT) is a cutting-edge radiation therapy modality that is currently not available in Australia. Comparative photon-proton (CPP) planning is required for the medical treatment overseas programme (MTOP) and will be required for access to PBT in Australia in the future. Comparative planning brings professional development benefits to all members of the radiation therapy team. This service was also created to support future proposals for a PBT facility in Victoria. We report our experience developing an in-house CPP service at Peter MacCallum Cancer Centre. A set of resources to support CPP planning was established. Training of relevant staff was undertaken after which an in-house training programme was developed. A standard protocol for PBT planning parameters was established. All CPP plans were reviewed. Future goals for the CPP planning programme were described. In total, 62 cases were comparatively planned over 54 months. Of these, 60% were paediatric cases, 14% were adolescents and young adults (15-25 years) and 26% were adults. The vast majority (over 75%) of patients comparatively planned required irradiation to the central nervous system including brain and cranio-spinal irradiation. A variety of proton plans were reviewed by international PBT experts to confirm their deliverability. Our team at Peter MacCallum Cancer Centre has gained significant experience in CPP planning and will continue to develop this further. Local expertise will help support decentralisation of patient selection for proton treatments in the near future and the PBT business case in Victoria.


Asunto(s)
Neoplasias , Terapia de Protones , Humanos , Niño , Adolescente , Protones , Victoria , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
12.
Lancet Oncol ; 25(3): 308-316, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38423047

RESUMEN

BACKGROUND: Stereotactic ablative body radiotherapy (SABR) is a novel non-invasive alternative for patients with primary renal cell cancer who do not undergo surgical resection. The FASTRACK II clinical trial investigated the efficacy of SABR for primary renal cell cancer in a phase 2 trial. METHODS: This international, non-randomised, phase 2 study was conducted in seven centres in Australia and one centre in the Netherlands. Eligible patients aged 18 years or older had biopsy-confirmed diagnosis of primary renal cell cancer, with only a single lesion; were medically inoperable, were at high risk of complications from surgery, or declined surgery; and had an Eastern Cooperative Oncology Group performance status of 0-2. A multidisciplinary decision that active treatment was warranted was required. Key exclusion criteria were a pre-treatment estimated glomerular filtration rate of less than 30 mL/min per 1·73 m2, previous systemic therapies for renal cell cancer, previous high-dose radiotherapy to an overlapping region, tumours larger than 10 cm, and direct contact of the renal cell cancer with the bowel. Patients received either a single fraction SABR of 26 Gy for tumours 4 cm or less in maximum diameter, or 42 Gy in three fractions for tumours more than 4 cm to 10 cm in maximum diameter. The primary endpoint was local control, defined as no progression of the primary renal cell cancer, as evaluated by the investigator per Response Evaluation Criteria in Solid Tumours (version 1.1). Assuming a 1-year local control of 90%, the null hypothesis of 80% or less was considered not to be worthy of proceeding to a future randomised controlled trial. All patients who commenced trial treatment were included in the primary outcome analysis. This trial is registered with ClinicalTrials.gov, NCT02613819, and has completed accrual. FINDINGS: Between July 28, 2016, and Feb 27, 2020, 70 patients were enrolled and initiated treatment. Median age was 77 years (IQR 70-82). Before enrolment, 49 (70%) of 70 patients had documented serial growth on initial surveillance imaging. 49 (70%) of 70 patients were male and 21 (30%) were female. Median tumour size was 4·6 cm (IQR 3·7-5·5). All patients enrolled had T1-T2a and N0-N1 disease. 23 patients received single-fraction SABR of 26 Gy and 47 received 42 Gy in three fractions. Median follow-up was 43 months (IQR 38-60). Local control at 12 months from treatment commencement was 100% (p<0·0001). Seven (10%) patients had grade 3 treatment-related adverse events, with no grade 4 adverse events observed. Grade 3 treatment-related adverse events were nausea and vomiting (three [4%] patients), abdominal, flank, or tumour pain (four [6%]), colonic obstruction (two [3%]), and diarrhoea (one [1%]). No treatment-related or cancer-related deaths occurred. INTERPRETATION: To our knowledge, this is the first multicentre prospective clinical trial of non-surgical definitive therapy in patients with primary renal cell cancer. In a cohort with predominantly T1b or larger disease, SABR was an effective treatment strategy with no observed local failures or cancer-related deaths. We observed an acceptable side-effect profile and renal function after SABR. These outcomes support the design of a future randomised trial of SABR versus surgery for primary renal cell cancer. FUNDING: Cancer Australia Priority-driven Collaborative Cancer Research Scheme.


Asunto(s)
Carcinoma de Células Renales , Neoplasias Renales , Radiocirugia , Anciano , Femenino , Humanos , Masculino , Carcinoma de Células Renales/radioterapia , Neoplasias Renales/radioterapia , Neoplasias Renales/patología , Estudios Prospectivos , Radiocirugia/efectos adversos , Radiocirugia/métodos , Resultado del Tratamiento , Anciano de 80 o más Años
13.
Phys Eng Sci Med ; 47(2): 551-561, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38285272

RESUMEN

Bolus is commonly used to improve dose distributions in radiotherapy in particular if dose to skin must be optimised such as in breast or head and neck cancer. We are documenting four years of experience with 3D printed bolus at a large cancer centre. In addition to this we review the quality assurance (QA) program developed to support it. More than 2000 boluses were produced between Nov 2018 and Feb 2023 using fused deposition modelling (FDM) printing with polylactic acid (PLA) on up to five Raise 3D printers. Bolus is designed in the radiotherapy treatment planning system (Varian Eclipse), exported to an STL file followed by pre-processing. After checking each bolus with CT scanning initially we now produce standard quality control (QC) wedges every month and whenever a major change in printing processes occurs. A database records every bolus printed and manufacturing details. It takes about 3 days from designing the bolus in the planning system to delivering it to treatment. A 'premium' PLA material (Spidermaker) was found to be best in terms of homogeneity and CT number consistency (80 HU +/- 8HU). Most boluses were produced for photon beams (93.6%) with the rest used for electrons. We process about 120 kg of PLA per year with a typical bolus weighing less than 500 g and the majority of boluses 5 mm thick. Print times are proportional to bolus weight with about 24 h required for 500 g material deposited. 3D printing using FDM produces smooth and reproducible boluses. Quality control is essential but can be streamlined.


Asunto(s)
Impresión Tridimensional , Humanos , Garantía de la Calidad de Atención de Salud/normas , Control de Calidad , Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada por Rayos X , Dosificación Radioterapéutica , Poliésteres/química
14.
Int J Radiat Oncol Biol Phys ; 119(4): 1297-1306, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38246249

RESUMEN

PURPOSE: Artificial intelligence (AI)-based auto-segmentation models hold promise for enhanced efficiency and consistency in organ contouring for adaptive radiation therapy and radiation therapy planning. However, their performance on pediatric computed tomography (CT) data and cross-scanner compatibility remain unclear. This study aimed to evaluate the performance of AI-based auto-segmentation models trained on adult CT data when applied to pediatric data sets and explore the improvement in performance gained by including pediatric training data. It also examined their ability to accurately segment CT data acquired from different scanners. METHODS AND MATERIALS: Using the nnU-Net framework, segmentation models were trained on data sets of adult, pediatric, and combined CT scans for 7 pelvic/thoracic organs. Each model was trained on 290 to 300 cases per category and organ. Training data sets included a combination of clinical data and several open repositories. The study incorporated a database of 459 pediatric (0-16 years) CT scans and 950 adults (>18 years), ensuring all scans had human expert ground-truth contours of the selected organs. Performance was evaluated based on Dice similarity coefficients (DSC) of the model-generated contours. RESULTS: AI models trained exclusively on adult data underperformed on pediatric data, especially for the 0 to 2 age group: mean DSC was below 0.5 for the bladder and spleen. The addition of pediatric training data demonstrated significant improvement for all age groups, achieving a mean DSC of above 0.85 for all organs in every age group. Larger organs like the liver and kidneys maintained consistent performance for all models across age groups. No significant difference emerged in the cross-scanner performance evaluation, suggesting robust cross-scanner generalization. CONCLUSIONS: For optimal segmentation across age groups, it is important to include pediatric data in the training of segmentation models. The successful cross-scanner generalization also supports the real-world clinical applicability of these AI models. This study emphasizes the significance of data set diversity in training robust AI systems for medical image interpretation tasks.


Asunto(s)
Aprendizaje Profundo , Tomografía Computarizada por Rayos X , Humanos , Niño , Preescolar , Lactante , Adolescente , Adulto , Recién Nacido , Bazo/diagnóstico por imagen , Conjuntos de Datos como Asunto , Vejiga Urinaria/diagnóstico por imagen , Hígado/diagnóstico por imagen , Pelvis/diagnóstico por imagen , Masculino , Riñón/diagnóstico por imagen , Femenino , Factores de Edad , Persona de Mediana Edad
15.
Med Phys ; 51(1): 682-693, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37797078

RESUMEN

BACKGROUND: Lattice radiation therapy (LRT) alternates regions of high and low doses within the target. The heterogeneous dose distribution is delivered to a geometrical structure of vertices segmented inside the tumor. LRT is typically used to treat patients with large tumor volumes with cytoreduction intent. Due to the geometric complexity of the target volume and the required dose distribution, LRT treatment planning demands additional resources, which may limit clinical integration. PURPOSE: We introduce a fully automated method to (1) generate an ordered lattice of vertices with various sizes and center-to-center distances and (2) perform dose optimization and calculation. We aim to report the dosimetry associated with these lattices to help clinical decision-making. METHODS: Sarcoma cancer patients with tumor volume between 100 cm3 and 1500 cm3 who received radiotherapy treatment between 2010 and 2018 at our institution were considered for inclusion. Automated segmentation and dose optimization/calculation were performed by using the Eclipse Scripting Application Programming Interface (ESAPI, v16, Varian Medical Systems, Palo Alto, USA). Vertices were modeled by spheres segmented within the gross tumor volume (GTV) with 1 cm/1.5 cm/2 cm diameters (LRT-1 cm/1.5 cm/2 cm) and 2 to 5 cm center-to-center distance on square lattices alternating along the superior-inferior direction. Organs at risk were modeled by subtracting the GTV from the body structure (body-GTV). The prescription dose was that 50% of the vertice volume should receive at least 20 Gy in one fraction. The automated dose optimization included three stages. The vertices optimization objectives were refined during optimization according to their values at the end of the first and second stages. Lattices were classified according to a score based on the minimization of body-GTV max dose and the maximization of GTV dose uniformity (measured with the equivalent uniform dose [EUD]), GTV dose heterogeneity (measured with the GTV D90%/D10% ratio), and the number of patients with more than one vertex inserted in the GTV. Plan complexity was measured with the modulation complexity score (MCS). Correlations were assessed with the Spearman correlation coefficient (r) and its associated p-value. RESULTS: Thirty-three patients with GTV volumes between 150 and 1350 cm3 (median GTV volume = 494 cm3 , IQR = 272-779 cm3 were included. The median time required for segmentation/planning was 1 min/21 min. The number of vertices was strongly correlated with GTV volume in each LRT lattice for each center-to-center distance (r > 0.85, p-values < 0.001 in each case). Lattices with center-to-center distance = 2.5 cm/3 cm/3.5 cm in LRT-1.5 cm and center-to-center distance = 4 cm in LRT-1 cm had the best scores. These lattices were characterized by high heterogeneity (median GTV D90%/D10% between 0.06 and 0.19). The generated plans were moderately complex (median MCS ranged between 0.19 and 0.40). CONCLUSIONS: The automated LRT planning method allows for the efficacious generation of vertices arranged in an ordered lattice and the refinement of planning objectives during dose optimization, enabling the systematic evaluation of LRT dosimetry from various lattice geometries.


Asunto(s)
Neoplasias , Radioterapia Conformacional , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Dosificación Radioterapéutica
16.
Int J Radiat Oncol Biol Phys ; 118(4): 944-951, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37871885

RESUMEN

PURPOSE: The TROG 13.01 (SAFRON II) trial was a phase 2 multicenter trial comparing single-fraction (SF) and multifraction (MF) stereotactic body radiation therapy. Patients with 1 to 3 peripheral pulmonary oligometastases were randomized 1:1 between 28 Gy in 1 fraction and 48 Gy in 4 fractions. There were no differences between arms in efficacy or toxicity. We performed an analysis to assess changes in pulmonary function tests (PFTs) between arms over time and assessed the effect of the number and total volume of targets on PFT change over time. METHODS AND MATERIALS: A linear mixed model was used to describe the PFTs by treatment arm over time. The effect of number and volume of targets on PFTs at 6 and 12 months was assessed by a simple linear model. RESULTS: Ninety patients were randomized; 87 were treated for 133 pulmonary oligometastases. Forty-four were randomized to the SF arm and 43 to the MF arm. There were no differences in absolute or relative PFT measures of forced expiratory volume in 1 second (FEV1), diffusing capacity of the lungs for carbon monoxide (DLCO), or forced vital capacity (FVC) between the 2 arms. At 12 months, there was a reduction in absolute DLCO from baseline (-1.7 mL/min/mm Hg [95% CI, -2.5 to -1.0]), relative DLCO (-5.5% [95% CI, -8.4% to -2.6%]), absolute FEV1 (-0.17 L [95% CI, -0.23 to -0.11]), and absolute FVC (-0.20 L [95% CI, -0.27 to -0.13]). In patients with multiple pulmonary targets, increase in target number (per lesion) was associated with a reduction in the absolute FEV1 at 6 months of -0.10 L (95% CI, -0.18 to -0.03; P = .007), FEV1 at 12 months of -0.10 L (95% CI, -0.20 to -0.01; P = .04), FVC at 6 months of -0.11 L (95% CI, -0.20 to -0.03; P = .014), and FVC at 24 months of -0.13 L (95% CI, -0.25 to -0.01; P = .036). Reduction in FEV1 was also seen per 10-mL increase in PTV at 12 months (-0.03 L [95% CI, -0.06 to -0.00], P = .036). The number of targets and PTV were not associated with DLCO. CONCLUSIONS: Treating multiple targets resulted in increased loss of FEV1 and FVC but not DLCO. There were no significant differences in PFT decline between SF and MF stereotactic body radiation therapy.


Asunto(s)
Enfermedades Pulmonares , Pulmón , Humanos , Volumen Espiratorio Forzado , Capacidad Vital , Pruebas de Función Respiratoria
17.
Int J Radiat Oncol Biol Phys ; 118(4): 1135-1143, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-37914141

RESUMEN

PURPOSE: Radiation therapy treatment for non-small cell lung cancer (NSCLC) may result in radiation damage to the perfused lung. The loss in perfusion may be measured from positron tomography emission (PET) perfusion imaging; however, this modality may not be widely available. Dual-energy computed tomography (DECT) with contrast may be an alternative to PET/CT. The purpose of this work is to investigate the equivalence of dose-response curves (DRCs) determined from PET and DECT in NSCLC. METHODS AND MATERIALS: PET and DECT data sets from the prospective clinical trial HI-FIVE (NTC03569072) were included in this preplanned trial analysis. Patients underwent 68Ga-macroaggregated albumin PET/CT examination and DECT with contrast on the same day at baseline and at 3 and 12 months after treatment. The perfused lung was defined from a threshold based on the maximum standardized uptake value (%SUVmax)/iodine concentration (%IoMax) in PET/DECT. The equivalence between PET and DECT DRC was established by comparing (1) the average of the normalized overlap of the 2 DRCs ranging from 0 (no overlap) to 1 (perfect overlap) and (2) the slope of a linear model applied to DRCs. RESULTS: Of the 19 patients enrolled in the clinical trial, 14/10 patients had a posttreatment imaging session at a median of 4.5/13.5 months, respectively. With 30%SUVmax/35%IoMax, the average normalized overlap was maximized, and the difference between PET and DECT slopes of the linear model was minimized at each time point (slope = 0.76%/Gy / 0.75%/Gy at 3 months and 0.86%/Gy / 0.87%/Gy at 12 months determined from PET/DECT). CONCLUSIONS: The dose-response relationship determined from DECT was comparable to that from PET at 3 and 12 months after treatment in patients with NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Prospectivos , Pulmón/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Perfusión , Fluorodesoxiglucosa F18
18.
Int J Radiat Oncol Biol Phys ; 117(5): 1096-1106, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37393022

RESUMEN

PURPOSE: The TOPGEAR phase 3 trial hypothesized that adding preoperative chemoradiation therapy (CRT) to perioperative chemotherapy will improve survival in patients with gastric cancer. Owing to the complexity of gastric irradiation, a comprehensive radiation therapy quality assurance (RTQA) program was implemented. Our objective is to describe the RTQA methods and outcomes. METHODS AND MATERIALS: RTQA was undertaken in real time before treatment for the first 5 patients randomized to CRT from each center. Once acceptable quality was achieved, RTQA was completed for one-third of subsequent cases. RTQA consisted of evaluating (1) clinical target volume and organ-at-risk contouring and (2) radiation therapy planning parameters. Protocol violations between high- (20+ patients enrolled) and low-volume centers were compared using the Fisher exact test. RESULTS: TOPGEAR enrolled 574 patients, of whom 286 were randomized to receive preoperative CRT and 203 (71%) were included for RTQA. Of these, 67 (33%) and 136 (67%) patients were from high- and low-volume centers, respectively. The initial RTQA pass rate was 72%. In total, 28% of cases required resubmission. In total, 200 of 203 cases (99%) passed RTQA before treatment. Cases from low-volume centers required resubmission more often (44/136 [33%] vs 13/67 [18%]; P = .078). There was no change in the proportion of cases requiring resubmission over time. Most cases requiring resubmission had multiple protocol violations. At least 1 aspect of the clinical target volume had to be adjusted in all cases. Inadequate coverage of the duodenum was most common (53% major violation, 25% minor violation). For the remaining cases, the resubmission process was triggered secondary to poor contour/plan quality. CONCLUSIONS: In a large multicenter trial, RTQA is feasible and effective in achieving high-quality treatment plans. Ongoing education should be performed to ensure consistent quality during the entire study period.


Asunto(s)
Neoplasias Gástricas , Humanos , Neoplasias Gástricas/terapia , Terapia Neoadyuvante , Estudios de Factibilidad , Garantía de la Calidad de Atención de Salud , Quimioradioterapia
19.
J Med Imaging Radiat Oncol ; 67(6): 684-690, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37343142

RESUMEN

INTRODUCTION: Total body irradiation (TBI) practices vary considerably amongst centres, and the risk of treatment related toxicities remains unclear. We report lung doses for 142 TBI patients who underwent either standing TBI with lung shield blocks or lying TBI without blocks. METHODS: Lung doses were calculated for 142 TBI patients treated between June 2016 and June 2021. Patients were planned using Eclipse (Varian Medical Systems) using AAA_15.6.06 for photon dose calculations and EMC_15.6.06 for electron chest wall boost fields. Mean and maximum lung doses were calculated. RESULTS: Thirty-seven patients (26.2%) were treated standing using lung shielding blocks with 104 (73.8%) treated lying down. Lowest relative mean lung doses were achieved using lung shielding blocks in standing TBI, reducing the mean lung doses to 75.2% of prescription (9.9 Gy), ±4.1% (range 68.6-84.1%) for a prescribed dose of 13.2 Gy in 11 fractions, including contributions from electron chest wall boost fields, compared to 12 Gy in 6 fraction lying TBI receiving 101.6% mean lung dose (12.2 Gy) ±2.4% (range 95.2-109.5%) (P ≪ 0.05). Patients treated lying down with 2 Gy single fraction received the highest relative mean lung dose on average, with 108.4% (2.2 Gy) ±2.6% of prescription (range 103.2-114.4%). CONCLUSION: Lung doses have been reported for 142 TBI patients using the lying and standing techniques described herein. Lung shielding blocks significantly reduced mean lung doses despite the addition of electron boost fields to the chest wall.


Asunto(s)
Neoplasias Hematológicas , Irradiación Corporal Total , Humanos , Irradiación Corporal Total/efectos adversos , Irradiación Corporal Total/métodos , Pulmón , Neoplasias Hematológicas/etiología , Neoplasias Hematológicas/terapia , Dosificación Radioterapéutica
20.
Artículo en Inglés | MEDLINE | ID: mdl-37269265

RESUMEN

PURPOSE: Children who receive cranial radiation therapy (RT) as a component of treatment for malignancy are often at risk of long-term central endocrine toxicity secondary to radiation to the hypothalamic-pituitary axis (HPA). A comprehensive analysis was performed of central endocrine late effects in survivors of childhood cancer treated with RT as part of the Pediatric Normal Tissue Effects in the Clinic (PENTEC) consortium. METHODS AND MATERIALS: A systematic review of the risk of RT-related central endocrine effects was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). A total of 4629 publications were identified, of which 16 met criteria for inclusion in dose modeling analysis, with a total of 570 patients in 19 cohorts. Eighteen cohorts reported outcomes for growth hormone deficiency (GHD), 7 reported outcomes for central hypothyroidism (HT), and 6 reported outcomes for adrenocorticotropic hormone (ACTH) deficiency. RESULTS: Normal tissue complication probability modeling for GHD (18 cohorts, 545 patients) yielded D50 = 24.9 Gy (95% CI, 20.9-28.0) and γ50 = 0.5 (95% CI, 0.27-0.78). The normal tissue complication probability model fit for whole brain irradiation in children with a median age of >5 years indicated a 20% risk of GHD for patients who receive a mean dose of 21 Gy in 2-Gy fractions to the HPA. For HT, among 7 cohorts (250 patients), D50 = 39 Gy (95% CI, 34.1-53.2) and γ50 = 0.81 (95% CI, 0.46-1.35), with a 20% risk of HT in children who receive a mean dose of 22 Gy in 2-Gy fractions to the HPA. For ACTH deficiency (6 cohorts, 230 patients), D50 = 61 Gy (95% CI, 44.7-119.4) and γ50 = 0.76 (95% CI, 0.5-1.19); there is a 20% risk of ACTH deficiency in children who receive a mean dose of 34 Gy in 2-Gy fractions to the HPA. CONCLUSIONS: RT dose to the HPA increases the risk of central endocrine toxicity, including GHD, HT, and ACTH deficiency. In some clinical situations, these toxicities may be difficult to avoid, and counseling of patients and families with respect to anticipated outcomes is important.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA