Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Heart Rhythm O2 ; 4(2): 111-118, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36873309

RESUMEN

Background: Favorable clinical outcomes are difficult to achieve in long-standing persistent atrial fibrillation (LSPAF) with catheter ablation (CA). The CONVERGE (Convergence of Epicardial and Endocardial Ablation for the Treatment of Symptomatic Persistent Atrial FIbrillation) trial evaluated the effectiveness of hybrid convergent (HC) ablation vs endocardial CA. Objective: The study sought to evaluate the safety and effectiveness of HC vs CA in the LSPAF subgroup from the CONVERGE trial. Methods: The CONVERGE trial was a prospective, multicenter, randomized trial that enrolled 153 patients at 27 sites. A post hoc analysis was performed on LSPAF patients. The primary effectiveness was freedom from atrial arrhythmias off new or increased dose of previously failed or intolerant antiarrhythmic drugs (AADs) through 12 months. The primary safety endpoint was major adverse event incidence through 30 days with HC. Key secondary effectiveness measures included (1) percent of patients achieving ≥90% AF burden reduction vs baseline and (2) AF freedom. Results: Sixty-five patients (42.5% of total enrollment) had LSPAF; 38 in HC and 27 in CA. Primary effectiveness was 65.8% (95% confidence interval [CI] 50.7%-80.9%) with HC vs 37.0% (95% CI 5.1%-52.4%) with CA (P = .022). Through 18 months, these rates were 60.5% (95% CI 50.0%-76.1%) with HC vs 25.9% (95% CI 9.4%-42.5%) with CA (P = .006). Secondary effectiveness rates were higher than CA with HC at 12 and 18 months. Freedom from atrial arrhythmias off AADs was 52.6% (95% CI 36.8%-68.5%) and 47.4% (95% CI 31.5%-63.2%) with HC at 12 and 18 months vs 25.9% (95% CI 9.4%-42.5%) and 22.2% (95% CI 6.5%-37.9%) with CA, respectively (12 months: P = .031; 18 months: P = .038). Three (7.9%) major adverse events occurred within 30 days of HC. Conclusion: Post hoc analysis demonstrated effectiveness and acceptable safety of HC compared with CA in LSPAF.

2.
Ann Card Anaesth ; 26(1): 105-108, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36722599

RESUMEN

Three different patients presented to our institution with right-sided infective endocarditis (IE). All three were found to have vegetation on the tricuspid valve. These patients were started on appropriate antimicrobial therapy according to their blood cultures sensitivities. Despite this management, the patients' clinical status did not improve solely on antimicrobials. Surgery was, therefore, indicated to remove the vegetations. Traditionally, the appropriate management would have been invasive surgery. However, these patients were subjected to a novel treatment in our institution for right-sided IE: percutaneous mechanical vegetation debulking with an AngioVac system. After this procedure, all three patients' clinical status improved drastically. This new less invasive approach seems to offer the same results as the traditional invasive surgery, with faster recovery time. More comparative studies are needed to confirm this idea.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Humanos , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/tratamiento farmacológico , Endocarditis Bacteriana/cirugía , Endocarditis/tratamiento farmacológico , Endocarditis/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
3.
Innovations (Phila) ; 16(1): 43-51, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33269957

RESUMEN

OBJECTIVE: Risk-scoring systems for surgical aortic valve replacement (AVR) were largely derived from sternotomy cases. We evaluated the accuracy of current risk scores in predicting outcomes after minimally invasive AVR (mini-AVR). Because transcatheter AVR (TAVR) is being considered for use in low-risk patients with aortic stenosis, accurate mini-AVR risk assessment is necessary. METHODS: We reviewed 1,018 consecutive isolated mini-AVR cases (2009 to 2015). After excluding patients with Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) scores ≥4, we calculated each patient's European System for Cardiac Operative Risk Evaluation (EuroSCORE) II, TAVR Risk Score (TAVR-RS), and age, creatinine, and ejection fraction score (ACEF). We compared all 4 scores' accuracy in predicting mini-AVR 30-day mortality by computing each score's observed-to-expected mortality ratio (O:E). Area under the receiver operating characteristic (ROC) curves tested discrimination, and the Hosmer-Lemeshow goodness-of-fit tested calibration. RESULTS: Among 941 patients (mean age, 72 ± 12 years), 6 deaths occurred within 30 days (actual mortality rate, 0.6%). All 4 scoring systems overpredicted expected mortality after mini-AVR: ACEF (1.4%), EuroSCORE II (1.9%), STS-PROM (2.0%), and TAVR-RS (2.1%). STS-PROM best estimated risk for patients with STS-PROM scores 0 to <1 (0.6 O:E), ACEF for patients with STS-PROM scores 2 to <3 (0.6 O:E), and TAVR-RS for patients with STS-PROM scores 3 to <4 (0.7 O:E). ROC curves showed only fair discrimination and calibration across all risk scores. CONCLUSIONS: In low-risk patients who underwent mini-AVR, current surgical scoring systems overpredicted mortality 2-to-3-fold. Alternative dedicated scoring systems for mini-AVR are needed for more accurate outcomes assessment.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Persona de Mediana Edad , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
4.
J Thorac Dis ; 9(Suppl 7): S607-S613, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28740714

RESUMEN

BACKGROUND: We evaluated the outcomes of patients with aortic valve pathology in the setting of a left ventricular ejection fraction ≤35% who underwent minimally invasive aortic valve replacement (AVR), with or without concomitant mitral valve (MV) surgery. METHODS: All minimally invasive AVR in patients with a left ventricular ejection fraction ≤35%, performed via a right thoracotomy for aortic stenosis or regurgitation between January 2009 and March 2013, were retrospectively evaluated. The operative characteristics, perioperative outcomes, and 30-day mortality were analyzed. RESULTS: There were 75 patients identified: 51 who underwent isolated AVR, and 24 who had combined AVR plus MV surgery for moderate to severe mitral regurgitation. In patients undergoing MV surgery, there were 22 (91.7%) MV repairs [ring annuloplasty =7 (37.5%), transaortic edge-to-edge repair =15 (62.5%)], and 2 (8.3%) replacements. No patient required conversion to sternotomy for inadequate surgical field exposure. The median total mechanical ventilation time and intensive care unit length of stay were 14 (IQR, 8-20) and 42 hours (IQR, 26-93 hours) in the isolated AVR group, and 16.5 hours (IQR, 12-61.5 hours) and 95.5 hours (IQR, 43.5-159 hours) in the AVR plus MV surgery group, respectively. The most common post-operative complication was new-onset atrial fibrillation, which occurred in 15 (29.4%) isolated AVR and 4 (16.7%) AVR plus MV surgery patients. The median hospital length of stay and 30-day mortality was 7 days (IQR, 5-12 days) and 1 (2%) in the isolated AVR group, and 10.5 days (IQR, 5-21 days) and 1 (4.3%) for AVR plus MV surgery. CONCLUSIONS: In patients with aortic valve pathology in the setting of a left ventricular ejection fraction ≤35%, minimally invasive AVR can be performed, with or without concomitant MV surgery, with a low morbidity and mortality.

5.
JACC Cardiovasc Interv ; 9(14): e141-3, 2016 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-27372192
6.
Innovations (Phila) ; 9(4): 302-5, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25062103

RESUMEN

OBJECTIVE: We present our experience of concomitant right coronary artery bypass grafting (CABG) and aortic valve replacement performed via a right minithoracotomy in patients with coronary lesions not amenable to percutaneous intervention. METHODS: A total of 17 patients underwent concomitant aortic valve replacement and right CABG between April 2008 and July 2013. A 5- to 6-cm minithoracotomy incision was made over the right second or third intercostal space, and the costochondral cartilage was transected. A saphenous vein bypass to the right coronary artery was then performed, initiating the anastomosis from the toe of the graft. Subsequently, the aortic valve was replaced using standard techniques. RESULTS: There were 6 men and 11 women. The median European System for Cardiac Operative Risk Evaluation II score mortality risk was 5% [interquartile range (IQR), 2%-8%]. The mean (SD) age was 77 (10) years, the left ventricular ejection fraction was 59% (8%), and the New York Heart Association functional class was 2.4 (0.8). One patient had a history of CABG. The mean (SD) cardiopulmonary bypass time was 168 (57) minutes, and the aortic cross-clamp time was 133 (36) minutes. Three patients underwent concomitant mitral valve surgery (replacement, 2; repair, 1). The median intensive care unit and hospital lengths of stay were 47 hours (IQR, 24-90) and 9 days (IQR, 5-13), respectively. There was one reoperation for bleeding, and there was one postoperative stroke. All patients were alive at a mean (SD) follow-up of 2 (1.1) years. CONCLUSIONS: Aortic valve replacement with concomitant CABG performed via a right minithoracotomy approach is feasible.


Asunto(s)
Válvula Aórtica/cirugía , Puente de Arteria Coronaria/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Toracotomía/métodos , Anciano , Femenino , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA