Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Radiol Clin North Am ; 57(1): 113-125, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30454807

RESUMEN

Congenital abnormalities of the thoracic aorta encompass a variety of disorders with variable clinical manifestations ranging from asymptomatic to life threatening. A variety of imaging modalities are available for the evaluation of these anomalies with computed tomography (CT) commonly preferred due to its excellent spatial resolution and rapid acquisitions, avoiding the need of general anesthesia or even sedation. We review the embryology, imaging findings, and associations of multiple congenital thoracic aorta malformations with emphasis in the role of CT angiography in the evaluation of these pathologies.


Asunto(s)
Aorta Torácica/anomalías , Enfermedades de la Aorta/congénito , Enfermedades de la Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Aorta Torácica/embriología , Medios de Contraste , Humanos
3.
Radiology ; 261(1): 156-64, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21873253

RESUMEN

PURPOSE: To prospectively compare adequacy of colonic cleansing, adequacy of solid stool and fluid tagging, and patient acceptance by using reduced-volume, 2-L polyethylene glycol (PEG) versus magnesium citrate bowel preparations for CT colonography. MATERIALS AND METHODS: This study was approved by the institutional Committee on Human Research and was compliant with HIPAA; all patients provided written consent. In this randomized, investigator-blinded study, 50 patients underwent oral preparation with either a 2-L PEG or a magnesium citrate solution, tagging with oral contrast agents, and subsequent CT colonography and segmentally unblinded colonoscopy. The residual stool (score 0 [best] to 3 [worst]) and fluid (score 0 [best] to 4 [worst]) burden and tagging adequacy were qualitatively assessed. Residual fluid attenuation was recorded as a quantitative measure of tagging adequacy. Patients completed a tolerance questionnaire within 2 weeks of scanning. Preparations were compared for residual stool and fluid by using generalized estimating equations; the Mann-Whitney test was used to compare the qualitative tagging score, mean residual fluid attenuation, and adverse effects assessed on the patient experience questionnaire. RESULTS: The mean residual stool (0.90 of three) and fluid burden (1.05 of four) scores for PEG were similar to those for magnesium citrate (0.96 [P = .58] and 0.98 [P = .48], respectively). However, the mean fecal and fluid tagging scores were significantly better for PEG (0.48 and 0.28, respectively) than for magnesium citrate (1.52 [P < .01] and 1.28 [P < .01], respectively). Mean residual fluid attenuation was higher for PEG (765 HU) than for magnesium citrate (443 HU, P = .01), and mean interpretation time was shorter for PEG (14.8 minutes) than for magnesium citrate (18.0 minutes, P = .04). Tolerance ratings were not significantly different between preparations. CONCLUSION: Reduced-volume PEG and magnesium citrate bowel preparations demonstrated adequate cleansing effectiveness for CT colonography, with better tagging and shorter interpretation time observed in the PEG group. Adequate polyp detection was maintained but requires further validation because of the small number of clinically important polyps.


Asunto(s)
Catárticos , Ácido Cítrico , Colonografía Tomográfica Computarizada , Compuestos Organometálicos , Polietilenglicoles , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Método Simple Ciego
4.
Radiology ; 248(3): 910-6, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18632527

RESUMEN

PURPOSE: To determine the effect of the number of detectors and peak tube voltage on renal cyst pseudoenhancement in a phantom model. MATERIALS AND METHODS: This study on computed tomographic (CT) phantoms did not require institutional review board approval. The renal compartments of a CT phantom were filled with iodinated contrast material diluted to attain attenuations of 40, 140, and 240 HU. Saline-filled cylinders simulating cysts of varying diameters (range, 0.7-3.0 cm) were serially suspended in the renal compartments and scanned at 80, 90, 100, 120, and 140 kVp in 16-detector (n = 3) and 64-detector (n = 2) CT scanners. Generalized estimating equations were used to determine predictors of cyst pseudoenhancement (defined as a >10 HU increase in cyst attenuation when the background renal attenuation increased from 40 to 140 or 240 HU). RESULTS: Pseudoenhancement was seen with higher frequency (59 [61%] of 96 cysts vs 52 [39%] of 132 cysts, P < .05) and magnitude (17 vs 13 HU, P < .005) with 64- rather than with 16-detector scanners. Pseudoenhancement was also seen with higher frequency (25 [42%] of 60 cysts vs 11 [18%] of 60 cysts, P < .005) and magnitude (18 vs 13 HU, P < .05) at 140 kVp than at 80 or 90 kVp. Cyst pseudoenhancement increased with higher background renal enhancement (P < .005) and smaller cyst diameter (P < .05). The number of detectors, peak tube voltage, renal parenchymal enhancement level, and cyst diameter were independent predictors of cyst pseudoenhancement. CONCLUSION: Lower tube voltage settings may be useful when accurate differentiation between small renal cysts and solid masses is critical, particularly for 64-detector CT scanners.


Asunto(s)
Enfermedades Renales Quísticas/diagnóstico por imagen , Riñón/diagnóstico por imagen , Intensificación de Imagen Radiográfica/instrumentación , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
Radiol Clin North Am ; 45(2): 333-45, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17502221

RESUMEN

Virtual colonoscopy (VC) has acquired an important role in evaluation of the colon. In some situations it may be a safer method to visualize the colon effectively, or it may be the only available option when other techniques have failed. This article reviews state-of-the art VC technique and the results of current performance trials. It discusses the rationale for using various colonic cleansing regimens for VC. It also discusses the two distending agents for VC (room air and carbon dioxide) and presents practical tips for administration and the role of antispasmodic drugs.


Asunto(s)
Enfermedades del Colon/diagnóstico por imagen , Colonografía Tomográfica Computarizada/métodos , Aire , Dióxido de Carbono , Catárticos/administración & dosificación , Diagnóstico Diferencial , Humanos , Parasimpatolíticos/administración & dosificación , Postura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA