J Orthop ; 35: 115-119, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36467427

RESUMEN

Background: Parallax is poorly understood and can mislead surgeons using intraoperative fluoroscopy (IF) to guide cup placement during anterior approach (AA) total hip arthroplasty. The purpose of this study was to examine how changes in fluoroscopic beam positioning in relation to the hip and pelvis affects the projected acetabular image. Methods: An acetabular component was positioned in an anatomic pelvis model in 45° and 20° of abduction and anteversion, respectively using a computer assisted cup targeting system. Fluoroscopic images were taken at various caudal and cranially directed angles with the fluoroscopic beam centered over the hip then pelvis. In each position, four independent observers measured the abduction and anteversion angles of the projected cup image using the same computer targeting system. Results: Cup abduction and anteversion measured 43.5° and 19.5° when IF was centered over the hip and 40.5 and 27.5° when centered over the pelvis in the neutral position. Increasing the caudal direction of the beam 20° increased the projected abduction/anteversion angles by approximately 7°/12° and 9°/16° when centered over the hip and pelvis respectively. Increasing the cranial direction of the beam 20° decreased the measured abduction/anteversion angles by roughly 4°/20° and 4°/24° when centered over the hip and pelvis, respectively. Conclusion: The projected image of the acetabular component can change dramatically depending on fluoroscopic beam position relative to the hip and pelvis. Recognizing the approximate direction and magnitude of change with differing fluoroscopy positions may help surgeons avoid cup malpositioning.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA