Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Diagnostics (Basel) ; 13(13)2023 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-37443569

RESUMEN

We investigated prognostic strategies for predicting good outcomes in the early stage of post-cardiac-arrest care using multiple prognostic tests that are available until 24 h after the return of spontaneous circulation (ROSC). A retrospective analysis was conducted on 138 out-of-hospital cardiac-arrest patients who underwent prognostic tests, including the gray-white-matter ratio (GWR-BG), the Glasgow Coma Scale motor (GCS-M) score before sedative administration, and the neuron-specific enolase (NSE) level measured at 24 h after the ROSC. We investigated the prognostic performances of the tests as single predictors and in various combination strategies. Classification and regression-tree analysis were used to provide a reliable model for the risk stratification. Out of all the patients, 55 (44.0%) had good outcomes. The NSE level showed the highest prognostic performance as a single prognostic test and provided improved specificities (>70%) and sensitivities (>98%) when used in combination strategies. Low NSE levels (≤32.1 ng/mL) and high GCS-M (≥4) scores identified good outcomes without misclassification. The overall accuracy for good outcomes was 81.8%. In comatose patients with low NSE levels or high GCS-M scores, the premature withdrawal of life-sustaining therapy should be avoided, thereby complying with the formal prognostication-strategy algorithm after at least 72 h from the ROSC.

2.
J Nucl Med ; 52(4): 572-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21421723

RESUMEN

UNLABELLED: Silicon photomultiplier (SiPM; also called a Geiger-mode avalanche photodiode) is a promising semiconductor photosensor in PET and PET/MRI because it is intrinsically MRI-compatible and has internal gain and timing properties comparable to those of a photomultiplier tube. In this study, we have developed a small-animal PET system using SiPMs and lutetium gadolinium oxyorthosilicate (LGSO) crystals and performed physical evaluation and animal imaging studies to show the feasibility of this system. METHODS: The SiPM PET system consists of 8 detectors, each of which comprises 2 × 6 SiPMs and 4 × 13 LGSO crystals. Each crystal has dimensions of 1.5 × 1.5 × 7 mm. The crystal face-to-face diameter and axial field of view are 6.0 cm and 6.5 mm, respectively. Bias voltage is applied to each SiPM using a finely controlled voltage supply because the gain of the SiPM strongly depends on the supply voltage. The physical characteristics were studied by measuring energy resolution, sensitivity, and spatial resolution. Various mouse and rat images were obtained to study the feasibility of the SiPM PET system in in vivo animal studies. Reconstructed PET images using a maximum-likelihood expectation maximization algorithm were coregistered with animal CT images. RESULTS: All individual LGSO crystals within the detectors were clearly distinguishable in flood images obtained by irradiating the detector using a (22)Na point source. The energy resolution for individual crystals was 25.8% ± 2.6% on average for 511-keV photopeaks. The spatial resolution measured with the (22)Na point source in a warm background was 1.0 mm (2 mm off-center) and 1.4 mm (16 mm off-center) when the maximum-likelihood expectation maximization algorithm was applied. A myocardial (18)F-FDG study in mice and a skeletal (18)F study in rats demonstrated the fine spatial resolution of the scanner. The feasibility of the SiPM PET system was also confirmed in the tumor images of mice using (18)F-FDG and (68)Ga-RGD and in the brain images of rats using (18)F-FDG. CONCLUSION: These results indicate that it is possible to develop a PET system using a promising semiconductor photosensor, which yielded reasonable PET performance in phantom and animal studies.


Asunto(s)
Fantasmas de Imagen , Tomografía de Emisión de Positrones/instrumentación , Animales , Huesos/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Electrónica , Diseño de Equipo , Fluorodesoxiglucosa F18 , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Compuestos Organometálicos , Ácido Pentético/análogos & derivados , Radiofármacos , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA