Artículo en Inglés | MEDLINE | ID: mdl-38083568

RESUMEN

Optical imaging techniques such as spectral imaging show promise for the assessment of tissue health during surgery; however, the validation and translation of such techniques into clinical practise is limited by the lack of representative tissue models. In this paper, we demonstrate the application of an organ perfusion machine as an ex vivo tissue model for optical imaging. Three porcine livers are perfused at stepped blood oxygen saturations. Over the duration of each perfusion, spectral data of the tissue are captured via diffuse optical spectroscopy and multispectral imaging. These data are synchronised with blood oxygen saturation measurements recorded by the perfusion machine. Shifts in the optical properties of the tissue are demonstrated over the duration of the each perfusion, as the tissue becomes reperfused and as the oxygen saturation is varied.


Asunto(s)
Hígado , Imagen Óptica , Porcinos , Animales , Perfusión/métodos , Hígado/diagnóstico por imagen
2.
Methods Protoc ; 6(4)2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37489433

RESUMEN

BACKGROUND: Machine perfusion (MP) is increasingly used for human transplant organ preservation. The use of MP for research purposes is another opportunity for this technology. The porcine pancreas and liver are similar in anatomical size and function to their human counterparts, making them an excellent resource for research, but they have some important differences from human organs which can influence their research use. In this paper, we describe a technique developed and tested for the retrieval of porcine organs for use in research on perfused viable organs. METHODS: Whole-organ porcine pancreata and livers were harvested at a commercial abattoir, following standard slaughterhouse processes. The standard slaughterhouse process involved a thoracotomy and mid-line laparotomy, and all the thoracoabdominal organs were removed. The pancreas, fixed in the retroperitoneum, was carefully dissected from its attachments to the surrounding structures, and tissue planes between the pancreas, spleen, duodenum, and colon were meticulously identified and dissected. Vessel exposure and division: The aorta, portal vein (PV), hepatic vein (HV), and hepatic artery (HA) were dissected and isolated, preserving the input and output channels for the liver and pancreas. A distal 3 cm of the aorta was preserved and divided and served as the input for the pancreas perfusions. The liver, PV, HV, and HA were preserved and divided to preserve the physiological channels of the input (PV and HA) and output (HV) for the liver perfusions. The porcine hepatic and pancreas anatomy shares significant resemblance with the gross anatomy found in humans, and this was taken into consideration when designing the perfusion circuitry. The porcine pancreas and spleen shared a common blood supply, with branches arising from the splenic artery. The organs were flushed with cold, heparinised normal saline and transported in a temperature-regulated receptacle maintained at a core temperature between 4 and 8 °C, in line with the standards of static cold storage (SCS), to a dedicated perfusion lab and perfused using our novel perfusion machine with autologous, heparinised porcine blood, also collected at the abattoir.

3.
Ann Biomed Eng ; 50(5): 549-563, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35258744

RESUMEN

Endoscopic endonasal skull base surgery is a promising alternative to transcranial approaches. However, standard instruments lack articulation, and thus, could benefit from robotic technologies. The aim of this study was to develop an ergonomic handle for a handheld robotic instrument intended to enhance this procedure. Two different prototypes were developed based on ergonomic guidelines within the literature. The first is a forearm-mounted handle that maps the surgeon's wrist degrees-of-freedom to that of the robotic end-effector; the second is a joystick-and-trigger handle with a rotating body that places the joystick to the position most comfortable for the surgeon. These handles were incorporated into a custom-designed surgical virtual simulator and were assessed for their performance and ergonomics when compared with a standard neurosurgical grasper. The virtual task was performed by nine novices with all three devices as part of a randomised crossover user-study. Their performance and ergonomics were evaluated both subjectively by themselves and objectively by a validated observational checklist. Both handles outperformed the standard instrument with the rotating joystick-body handle offering the most substantial improvement in terms of balance between performance and ergonomics. Thus, it is deemed the more suitable device to drive instrumentation for endoscopic endonasal skull base surgery.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Endoscopía , Ergonomía/métodos , Base del Cráneo/cirugía
4.
Int J Comput Assist Radiol Surg ; 16(7): 1131-1139, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34028662

RESUMEN

PURPOSE: The expanded endoscopic endonasal approach, a representative example of keyhole brain surgery, allows access to the pituitary gland and surrounding areas through the nasal and sphenoid cavities. Manipulating rigid instruments through these constrained spaces makes this approach technically challenging, and thus, a handheld robotic instrument could expand the surgeon's capabilities. In this study, we present an intuitive handle prototype for such a robotic instrument. METHODS: We have designed and fabricated a surgical instrument handle prototype that maps the surgeon's wrist directly to the robot joints. To alleviate the surgeon's wrist of any excessive strain and fatigue, the tool is mounted on the surgeon's forearm, making it parallel with the instrument's shaft. To evaluate the handle's performance and limitations, we constructed a surgical task simulator and compared our novel handle with a standard neurosurgical tool, with the tasks being performed by a consultant neurosurgeon. RESULTS: While using the proposed handle, the surgeon's average success rate was [Formula: see text], compared to [Formula: see text] when using a conventional tool. Additionally, the surgeon's body posture while using the suggested prototype was deemed acceptable by the Rapid Upper Limb Assessment ergonomic survey, while early results indicate the absence of a learning curve. CONCLUSIONS: Based on these preliminary results, the proposed handle prototype could offer an improvement over current neurosurgical tools and procedural ergonomics. By redirecting forces applied during the procedure to the forearm of the surgeon, and allowing for intuitive surgeon wrist to robot-joints movement mapping without compromising the robotic end effector's expanded workspace, we believe that this handle could prove a substantial step toward improved neurosurgical instrumentation.


Asunto(s)
Síndrome del Túnel Carpiano/cirugía , Ergonomía/métodos , Procedimientos Neuroquirúrgicos/instrumentación , Procedimientos Quirúrgicos Robotizados/instrumentación , Articulación de la Muñeca/cirugía , Diseño de Equipo , Humanos , Movimiento , Postura , Articulación de la Muñeca/fisiopatología
5.
Soft Robot ; 8(3): 284-297, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32589507

RESUMEN

To advance the field of soft robotics, a unified database of material constitutive models and experimental characterizations is of paramount importance. This will facilitate the use of finite element analysis to simulate their behavior and optimize the design of soft-bodied robots. Samples from seventeen elastomers, namely Body Double™ SILK, Dragon Skin™ 10 MEDIUM, Dragon Skin 20, Dragon Skin 30, Dragon Skin FX-Pro, Dragon Skin FX-Pro + Slacker, Ecoflex™ 00-10, Ecoflex 00-30, Ecoflex 00-50, Rebound™ 25, Mold Star™ 16 FAST, Mold Star 20T, SORTA-Clear™ 40, RTV615, PlatSil® Gel-10, Psycho Paint®, and SOLOPLAST 150318, were subjected to uniaxial tensile tests according to the ASTM D412 standard. Sample preparation and tensile test parameters are described in detail. The tensile test data are used to derive parameters for hyperelastic material models using nonlinear least-squares methods, which are provided to the reader. This article presents the mechanical characterization and the resulting material properties for a wide set of commercially available hyperelastic materials, many of which are recognized and commonly applied in the field of soft robotics, together with some that have never been characterized. The experimental raw data and the algorithms used to determine material parameters are shared on the Soft Robotics Materials Database GitHub repository to enable accessibility, as well as future contributions from the soft robotics community. The presented database is aimed at aiding soft roboticists in designing and modeling soft robots while providing a starting point for future material characterizations related to soft robotics research.


Asunto(s)
Robótica , Algoritmos , Elastómeros , Análisis de Elementos Finitos , Piel
7.
IEEE Trans Biomed Eng ; 67(8): 2215-2229, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31804926

RESUMEN

OBJECTIVE: In this work we address limitations in state-of-the-art ultrasound robots by designing and integrating a novel soft robotic system for ultrasound imaging. It employs the inherent qualities of soft fluidic actuators to establish safe, adaptable interaction between ultrasound probe and patient. METHODS: We acquire clinical data to determine the movement ranges and force levels required in prenatal foetal ultrasound imaging and design the soft robotic end-effector accordingly. We verify its mechanical characteristics, derive and validate a kinetostatic model and demonstrate controllability and imaging capabilities on an ultrasound phantom. RESULTS: The soft robot exhibits the desired stiffness characteristics and is able to reach 100% of the required workspace when no external force is present, and 95% of the workspace when considering its compliance. The model can accurately predict the end-effector pose with a mean error of 1.18±0.29 mm in position and 0.92±0.47° in orientation. The derived controller is, with an average position error of 0.39 mm, able to track a target pose efficiently without and with externally applied loads. Ultrasound images acquired with the system are of equally good quality compared to a manual sonographer scan. CONCLUSION: The system is able to withstand loads commonly applied during foetal ultrasound scans and remains controllable with a motion range similar to manual scanning. SIGNIFICANCE: The proposed soft robot presents a safe, cost-effective solution to offloading sonographers in day-to-day scanning routines. The design and modelling paradigms are greatly generalizable and particularly suitable for designing soft robots for physical interaction tasks.


Asunto(s)
Robótica , Diseño de Equipo , Humanos , Movimiento (Física) , Fantasmas de Imagen , Ultrasonografía
8.
J Vis Exp ; (143)2019 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-30663700

RESUMEN

With the potential for high precision, dexterity, and repeatability, a self-tracked robotic system can be employed to assist the acquisition of real-time ultrasound. However, limited numbers of robots designed for extra-corporeal ultrasound have been successfully translated into clinical use. In this study, we aim to build a bespoke robotic manipulator for extra-corporeal ultrasound examination, which is lightweight and has a small footprint. The robot is formed by five specially shaped links and custom-made joint mechanisms for probe manipulation, to cover the necessary range of motion with redundant degrees of freedom to ensure the patient's safety. The mechanical safety is emphasized with a clutch mechanism, to limit the force applied to patients. As a result of the design, the total weight of the manipulator is less than 2 kg and the length of the manipulator is about 25 cm. The design has been implemented, and simulation, phantom, and volunteer studies have been performed, to validate the range of motion, the ability to make fine adjustments, mechanical reliability, and the safe operation of the clutch. This paper details the design and implementation of the bespoke robotic ultrasound manipulator, with the design and assembly methods illustrated. Testing results to demonstrate the design features and clinical experience of using the system are presented. It is concluded that the current proposed robotic manipulator meets the requirements as a bespoke system for extra-corporeal ultrasound examination and has great potential to be translated into clinical use.


Asunto(s)
Robótica/instrumentación , Ultrasonografía , Fenómenos Biomecánicos , Diseño Asistido por Computadora , Diseño de Equipo , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados
9.
Appl Sci (Basel) ; 9(9): 1900, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-32754346

RESUMEN

Robotic systems have great potential to assist ultrasound (US) examination. Currently, the safety management method to limit the force that a US robot can apply mostly relies on force sensing and software-based algorithms. This causes the concern that the potential failure of sensors, electrical systems, or software could lead to patient injuries. In this paper, we investigated a customized spring-loaded ball clutch joint designed for a newly developed US robot to passively limit the force applied. The working mechanism of the clutch was modelled and the kinematic-based analysis was performed to understand the variation of the limited force at different postures of the robot. The triggering torque of the clutch was found to be 3928 N·mm, which results in the mean limited force 22.10 ± 1.76 N at the US probe end based on potential postures. The real measurement of the implemented design indicated that the limited force could be set between 17 and 24 N at the neutral posture depending on the preload. With the maximum preload, the mean limited force was found to be 21.98 ± 0.96 N based on 30 repeated measurements. The practically measured results meet the expectation from the theoretical calculation, and the resulting small variation has indicated a good repeatability of the clutch. Based on this evidence, it is concluded that the proposed clutch meets the design aim that it can limit the force applied within a safe range while at the same time ensuring that the required force is applied at different postures.