Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Fa Yi Xue Za Zhi ; 32(2): 114-8, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27501683

RESUMEN

OBJECTIVE: To determine the normal reference values of 33 elements, Ag, Al, As, Au, B, Ba, Be, Ca, Cd, Co, Cr, Cs, Cu, Fe, Ga, Hg, Li, Mg, Mn, Mo, Ni, Pb, Rb, Sb, Se, Sr, Th, Ti, Tl, U, V, Zn and Zr, in the blood and urine samples from the general population in Sanmen County of Zhejiang province, a typical coastal area of eastern China. METHODS: The 33 elements in 272 blood and 300 urine samples were determined by inductively coupled plasma-mass spectrometry (ICP-MS). The normality test of data was conducted using SPSS 17.0 Statistics. The data was compared with other reports. RESULTS: The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County were obtained, which of some elements were found to be similar with other reports, such as Co, Cu, Mn and Sr, while As, Cd, Hg and Pb were generally found to be higher than those previously reported. There was a wide variation between the reports from different countries in blood Ba. CONCLUSION: The normal reference values of the 33 elements in the blood and urine samples from the general population in Sanmen County are established, and successfully applied to two poisoning cases.


Asunto(s)
Análisis Químico de la Sangre , Elementos Químicos , Monitoreo del Ambiente , Urinálisis , China , Humanos
2.
Fa Yi Xue Za Zhi ; 29(6): 425-30, 2013 Dec.
Artículo en Chino | MEDLINE | ID: mdl-24665612

RESUMEN

OBJECTIVE: To establish the electricity plate digestion and inductively coupled plasma-mass spectrometry (ICP-MS) method for determination of 33 inorganic elements in human hair. METHODS: Lithium (6Li), Germanium (72Ge), Yttrium (89Y), Indium (115In), and Terbium (159Tb) were used as internal standards. The electric heating board digestion in a mixture of nitric acid and hydrogen peroxide was used as the pre-treatment of the hair. Thirty-three inorganic elements in human hair were analyzed by ICP-MS method. RESULTS: The detection limit of ICP-MS was 0.0001 microg/g(Th)-10.9 microg/g (Ca) and the limit of quantitation was 0.0005 microg/g (Th)-25 microg/g (Ca). The recovery rate of this method was 86%-113%. The RSD for the intra-day and inter-day were less than 9.2%. The method was not statistically different from microwave digestion method. CONCLUSION: This method is highly efficient and accurate. It can be used for analysis of 33 inorganic elements in human hair.


Asunto(s)
Cabello/química , Espectrometría de Masas/métodos , Microondas , Oligoelementos/análisis , Electricidad , Humanos , Límite de Detección , Estándares de Referencia , Sensibilidad y Especificidad
3.
Fa Yi Xue Za Zhi ; 28(6): 422-5, 2012 Dec.
Artículo en Chino | MEDLINE | ID: mdl-23484321

RESUMEN

OBJECTIVE: To establish the method for measurement of acetonitrile in blood and urine by head-space gas chromatography. METHODS: DB-ALC1 (30 m x 320 microm x 1.8 microm) and DB-ALC2 (30 m x 320 microm x 1.2 microm) capillary column were used to measure the acetonitrile in blood and urine with the isopropanol as internal standard reference. RESULTS: The limits of detection of acetonitrile in both blood and urine were 0.5 microg/mL, with a linear range of 5-1000 microg/mL (r = 0.999).The accuracy of this method was 93.2%-98.0%. The RSD for the intra-day and inter-day were less than 3.7%. CONCLUSION: The method is capable for measurement analysis of acetonitrile in blood and urine.


Asunto(s)
Acetonitrilos/sangre , Acetonitrilos/envenenamiento , Acetonitrilos/orina , Cromatografía de Gases/métodos , Cianuros/sangre , Cianuros/orina , Toxicología Forense/métodos , Humanos , Reproducibilidad de los Resultados , Intento de Suicidio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA