Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 147
Filtrar
Más filtros

Intervalo de año de publicación
2.
JTCVS Tech ; 25: 1-7, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899072

RESUMEN

Objective: To investigate the effect of graft sizing on valve performance in valve-sparing aortic root replacement for bicuspid aortic valve. Methods: In addition to a diseased control model, 3 representative groups-free-edge length to aortic/graft diameter (FELAD) ratio <1.3, 1.5 to 1.64, and >1.7-were replicated in explanted porcine aortic roots (n = 3) using straight grafts sized respective to the native free-edge length. They were run on a validated ex vivo univentricular system under physiological parameters for 20 cycles. All groups were tested within the same aortic root to minimize inter-root differences. Outcomes included transvalvular gradient, regurgitation fraction, and orifice area. Linear mixed effects model and pairwise comparisons were employed to compare outcomes across groups. Results: The diseased control had mean transvalvular gradient 10.9 ± 6.30 mm Hg, regurgitation fraction 32.5 ± 4.91%, and orifice area 1.52 ± 0.12 cm2. In ex vivo analysis, all repair groups had improved regurgitation compared with control (P < .001). FELAD <1.3 had the greatest amount of regurgitation among the repair groups (P < .001) and 1.5-1.64 the least (P < .001). FELAD <1.3 and >1.7 exhibited greater mean gradient compared with both control and 1.5 to 1.64 (P < .001). Among the repair groups, 1.5 to 1.64 had the largest orifice area, and >1.7 the smallest (P < .001). Conclusions: For a symmetric bicuspid aortic valve, performance after valve-sparing aortic root replacement shows a bimodal distribution across graft size. As the FELAD ratio departs from 1.5 to 1.64 in either direction, significant increases in transvalvular gradient are observed. FELAD <1.3 may also result in suboptimal improvement of baseline regurgitation.

3.
Pediatr Transplant ; 28(5): e14807, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38923151

RESUMEN

BACKGROUND: The United Network for Organ Sharing (UNOS) started recording data on intellectual disability status in 2008. This study aimed to characterize the long-term outcomes for children with intellectual disabilities (IDs) undergoing lung transplantation. METHODS: All pediatric patients (under 18 years old) undergoing bilateral lung transplantation were identified using the UNOS database. The patients were grouped into the following categories: no cognitive delay, possible cognitive delay, and definite cognitive delay. The primary endpoint was graft survival at 3-year posttransplantation. Multivariate Cox proportional hazards modeling was used to estimate the independent effect of cognitive disability on graft survival. RESULTS: Five hundred four pediatric patients who underwent lung transplantation between March 2008 and December 2022 were retrospectively analyzed. 59 had a definite cognitive delay (12%), 23 had a possible delay (5%), and 421 had no delay (83%). When comparing these three groups, there was no significant difference in 60-day graft survival (p = 0.4), 3-year graft survival (p = 0.6), 3-year graft survival for patients who survived at least 60-day posttransplantation (p = 0.9), distribution of causes of death (p = 0.24), nor distribution treatment of rejection within 1-year posttransplantation (p = 0.06). CONCLUSIONS: Intellectual disability does not impact long-term outcomes after bilateral lung transplantation. Intellectual disability should not be a contraindication to bilateral lung transplantation on the basis of inferior graft survival.


Asunto(s)
Supervivencia de Injerto , Discapacidad Intelectual , Trasplante de Pulmón , Modelos de Riesgos Proporcionales , Humanos , Discapacidad Intelectual/complicaciones , Femenino , Masculino , Niño , Estudios Retrospectivos , Adolescente , Preescolar , Resultado del Tratamiento , Lactante , Rechazo de Injerto/epidemiología , Estudios de Seguimiento
4.
J Heart Lung Transplant ; 43(6): 889-900, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38713124

RESUMEN

BACKGROUND: There is no FDA-approved left ventricular assist device (LVAD) for smaller children permitting routine hospital discharge. Smaller children supported with LVADs typically remain hospitalized for months awaiting heart transplant-a major burden for families and a challenge for hospitals. We describe the initial outcomes of the Jarvik 2015, a miniaturized implantable continuous flow LVAD, in the NHLBI-funded Pumps for Kids, Infants, and Neonates (PumpKIN) study, for bridge-to-heart transplant. METHODS: Children weighing 8 to 30 kg with severe systolic heart failure and failing optimal medical therapy were recruited at 7 centers in the United States. Patients with severe right heart failure and single-ventricle congenital heart disease were excluded. The primary feasibility endpoint was survival to 30 days without severe stroke or non-operational device failure. RESULTS: Of 7 children implanted, the median age was 2.2 (range 0.7, 7.1) years, median weight 10 (8.2 to 20.7) kilograms; 86% had dilated cardiomyopathy; 29% were INTERMACS profile 1. The median duration of Jarvik 2015 support was 149 (range 5 to 188) days where all 7 children survived including 5 to heart transplant, 1 to recovery, and 1 to conversion to a paracorporeal device. One patient experienced an ischemic stroke on day 53 of device support in the setting of myocardial recovery. One patient required ECMO support for intractable ventricular arrhythmias and was eventually transplanted from paracorporeal biventricular VAD support. The median pump speed was 1600 RPM with power ranging from 1-4 Watts. The median plasma free hemoglobin was 19, 30, 19 and 30 mg/dL at 7, 30, 90 and 180 days or time of explant, respectively. All patients reached the primary feasibility endpoint. Patient-reported outcomes with the device were favorable with respect to participation in a full range of activities. Due to financial issues with the manufacturer, the study was suspended after consent of the eighth patient. CONCLUSION: The Jarvik 2015 LVAD appears to hold important promise as an implantable continuous flow device for smaller children that may support hospital discharge. The FDA has approved the device to proceed to a 22-subject pivotal trial. Whether this device will survive to commercialization remains unclear because of the financial challenges faced by industry seeking to develop pediatric medical devices. (Supported by NIH/NHLBI HHS Contract N268201200001I, clinicaltrials.gov 02954497).


Asunto(s)
Estudios de Factibilidad , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Preescolar , Niño , Masculino , Lactante , Femenino , Estudios Prospectivos , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/cirugía , Insuficiencia Cardíaca/fisiopatología , Miniaturización , Diseño de Prótesis , Resultado del Tratamiento , Estados Unidos
5.
Ann Thorac Surg ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38750683

RESUMEN

BACKGROUND: Congenitally corrected transposition of the great arteries (CC-TGA) is a rare and complex form of congenital heart disease. Results of physiologic repair proved disappointing due to late right ventricular dysfunction and/or tricuspid regurgitation. The current study was performed to evaluate surgical outcomes in patients undergoing a double switch for CC-TGA. METHODS: This was a retrospective review of 121 patients who underwent a double switch over a 2-decade time frame (2002-2023). Patients were a median age of 32 months. Before the double switch, 49 of 121 patients (40%) had undergone left ventricular retraining. RESULTS: Sixty-seven patients underwent an arterial switch, and 54 underwent a Rastelli procedure. There were 4 in-hospital deaths (3.3%), including 3 who had a Rastelli procedure (5.6%) and 1 who had an arterial switch (1.5%). At a median follow-up of 30 months, there were 4 late deaths (2 Rastelli and 2 arterial switch). Combined early and late mortality was 9.3% for the Rastelli and 4.5% for arterial switch. Combined mortality was 2.0% for patients who required left ventricular retraining vs 9.7% for those who did not. For the 117 patients discharged from the hospital, 93% have normal or low-normal left ventricular function, and 96% have mild or less neoaortic insufficiency. CONCLUSIONS: Surgical outcomes in patients undergoing a double switch procedure have been excellent both in the short- and midterm. However, the Rastelli procedure was associated with a more than 2-fold increase in mortality risk compared with the arterial switch.

6.
Clin Transplant ; 38(4): e15302, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38567883

RESUMEN

INTRODUCTION: As the adult Fontan population with Fontan associated liver disease continues to increase, more patients are being referred for transplantation, including combined heart and liver transplantation. METHODS: We report updated mortality and morbidity outcomes after combined heart and liver transplant in a retrospective cohort series of 40 patients (age 14 to 49 years) with Fontan circulation across two centers from 2006-2022. RESULTS: The 30-day, 1-year, 5-year and 10-year survival rate was 90%, 80%, 73% and 73% respectively. Sixty percent of patients met a composite comorbidity of needing either post-transplant mechanical circulatory support, renal replacement therapy or tracheostomy. Cardiopulmonary bypass time > 283 min (4.7 h) and meeting the composite comorbidity were associated with mortality by Kaplan Meier analysis. CONCLUSION: Further study to mitigate early mortality and the above comorbidities as well as the high risk of bleeding and vasoplegia in this patient population is warranted.


Asunto(s)
Cardiopatías Congénitas , Trasplante de Corazón , Hepatopatías , Trasplante de Hígado , Adulto , Humanos , Adolescente , Adulto Joven , Persona de Mediana Edad , Trasplante de Hígado/efectos adversos , Estudios Retrospectivos , Hepatopatías/cirugía , Morbilidad , Cardiopatías Congénitas/cirugía
7.
JAMA Netw Open ; 7(3): e241828, 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38466306

RESUMEN

Importance: The use of ex vivo normothermic organ perfusion has enabled the use of deceased after circulatory death (DCD) donors for heart transplants. However, compared with conventional brain death donation, DCD heart transplantation performed with ex vivo organ perfusion involves an additional period of warm and cold ischemia, exposing the allograft to multiple bouts of ischemia reperfusion injury and may contribute to the high rates of extracorporeal membrane oxygenation usage after DCD heart transplantation. Objective: To assess whether the beating heart method of DCD heart transplantation is safe and whether it has an acceptable rate of extracorporeal membrane oxygenation use postoperatively. Design, Setting, and Participants: This case series includes 10 patients with end-stage heart failure undergoing DCD heart transplantation at a single academic medical center from October 1, 2022, to August 3, 2023. Data were analyzed from October 2022 to August 2023. Interventions: Using a beating heart method of implantation of the donor allograft. Main Outcomes and Measures: The main outcome was primary graft dysfunction necessitating postoperative initiation of mechanical circulatory support. Survival and initiation of mechanical circulatory support were secondary outcomes. Results: In this case series, 10 consecutive patients underwent DCD heart transplantation via the beating heart method. Ten of 10 recipients were male (100%), the mean (SD) age was 51.2 (13.8) years, and 7 (70%) had idiopathic dilated cardiomyopathy. Ten patients (100%) survived, and 0 patients had initiation of extracorporeal membrane oxygenation postoperatively. No other mechanical circulatory support, including intra-aortic balloon pump, was initiated postoperatively. Graft survival was 100% (10 of 10 patients), and, at the time of publication, no patients have been listed for retransplantation. Conclusions and Relevance: In this study of 10 patients undergoing heart transplantation, the beating heart implantation method for DCD heart transplantation was safe and may mitigate ischemia reperfusion injury, which may lead to lower rates of primary graft dysfunction necessitating extracorporeal membrane oxygenation. These results are relevant to institutions using DCD donors for heart transplantation.


Asunto(s)
Sistema Cardiovascular , Trasplante de Corazón , Disfunción Primaria del Injerto , Humanos , Masculino , Persona de Mediana Edad , Femenino , Corazón , Donantes de Tejidos
8.
Int J Numer Method Biomed Eng ; 40(5): e3820, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38544354

RESUMEN

The substantial computational cost of high-fidelity models in numerical hemodynamics has, so far, relegated their use mainly to offline treatment planning. New breakthroughs in data-driven architectures and optimization techniques for fast surrogate modeling provide an exciting opportunity to overcome these limitations, enabling the use of such technology for time-critical decisions. We discuss an application to the repair of multiple stenosis in peripheral pulmonary artery disease through either transcatheter pulmonary artery rehabilitation or surgery, where it is of interest to achieve desired pressures and flows at specific locations in the pulmonary artery tree, while minimizing the risk for the patient. Since different degrees of success can be achieved in practice during treatment, we formulate the problem in probability, and solve it through a sample-based approach. We propose a new offline-online pipeline for probabilistic real-time treatment planning which combines offline assimilation of boundary conditions, model reduction, and training dataset generation with online estimation of marginal probabilities, possibly conditioned on the degree of augmentation observed in already repaired lesions. Moreover, we propose a new approach for the parametrization of arbitrarily shaped vascular repairs through iterative corrections of a zero-dimensional approximant. We demonstrate this pipeline for a diseased model of the pulmonary artery tree available through the Vascular Model Repository.


Asunto(s)
Estenosis de Arteria Pulmonar , Humanos , Estenosis de Arteria Pulmonar/cirugía , Estenosis de Arteria Pulmonar/fisiopatología , Arteria Pulmonar/fisiopatología , Modelos Cardiovasculares , Hemodinámica/fisiología , Redes Neurales de la Computación
9.
Am J Perinatol ; 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38408479

RESUMEN

OBJECTIVE: To investigate the association of congenital heart disease (CHD) with morbidity and mortality of very low birth weight (VLBW) infants. STUDY DESIGN: This matched case-control study included VLBW infants born at a single institution between 2001 and 2015. The primary outcome was mortality. Secondary outcomes included necrotizing enterocolitis, bronchopulmonary dysplasia (BPD), sepsis, retinopathy of prematurity, and intraventricular hemorrhage. These outcomes were assessed by comparing VLBW-CHDs with control VLBW infants matched by gestational age within a week, birth weight within 500 g, sex, and birth date within a year using conditional logistic regression. Multivariable logistic regression analyzed differences in outcomes in the VLBW-CHD group between two birth periods (2001-2008 and 2009-2015) to account for changes in practice. RESULTS: In a cohort of 44 CHD infants matched with 88 controls, the mortality rate was 27% in infants with CHD and 1% in controls (p < 0.0001). The VLBW-CHDs had increased BPD; (odds ratio [OR]: 7.70, 95% confidence interval [CI]: 1.96-30.29) and sepsis (OR: 10.59, 95% CI: 2.99-37.57) compared with the control VLBWs. When adjusted for preoperative ventilator use, the VLBW-CHDs still had significantly higher odds of BPD (OR: 6.97, 95% CI: 1.73-28.04). VLBW-CHDs also had significantly higher odds of both presumed and culture-positive sepsis as well as late-onset sepsis than their matched controls. There were no significant differences in outcomes between the two birth periods. CONCLUSION: VLBW-CHDs showed higher odds of BPD, sepsis, and mortality than VLBW infants without CHD. Future research should focus on the increased mortality and specific complications encountered by VLBW infants with CHD and implement targeted strategies to address these risks. KEY POINTS: · Incidence of CHD is higher in preterm infants than in term infants but the incidence of their morbidities is not well described.. · VLBW infants with CHD have higher odds of mortality, bronchopulmonary dysplasia, and sepsis.. · Future research is needed to implement targeted preventive responses..

10.
Pediatr Cardiol ; 45(4): 795-803, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38360921

RESUMEN

This study describes right ventricle (RV) characteristics and right ventricle to pulmonary artery (RV-PA) conduit function pre- and post-repair in patients with tetraology of Fallot with major aortopulmonary collaterals (TOF/MAPCAs). We reviewed patients who underwent single-stage, complete unifocalization, and repair of TOF/MAPCAs between 2006 and 2019 with available pre- and early postoperative echocardiograms. For a subset of patients, 6-12 month follow-up echocardiogram was available. RV and left ventricle (LV) characteristics and RV-PA conduit function were reviewed. Wilcoxon signed rank test and McNemar's test were used. 170 patients were reviewed, 46 had follow-up echocardiograms. Tricuspid valve annular plane systolic excursion (TAPSE) Z-scores were reduced from pre- (Z-score 0.01) to post-repair (Z-score -4.5, p < 0.001), improved but remained abnormal at follow-up (Z-score -4.0, p < 0.001). RV fractional area change (FAC) and LV ejection fraction were not significantly different before and after surgery. Conduit regurgitation was moderate or greater in 11% at discharge, increased to 65% at follow-up. RV-PA conduit failure (severe pulmonary stenosis or severe pulmonary regurgitation) was noted in 61, and 63% had dilated RV (diastolic RV area Z-score > 2) at follow-up. RV dilation correlated with the severe conduit regurgitation (p = 0.018). Longitudinal RV function was reduced after complete repair of TOF/MAPCAs, with decreased TAPSE and preserved FAC and LV ejection fraction. TAPSE improved but did not normalize at follow-up. Severe RV-PA conduit dysfunction was observed prior to discharge in 11% of patients and in 61% at follow-up. RV dilation was common at follow-up, especially in the presence of severe conduit regurgitation.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Estenosis de la Válvula Pulmonar , Tetralogía de Fallot , Humanos , Ventrículos Cardíacos , Tetralogía de Fallot/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Estudios Retrospectivos , Estenosis de la Válvula Pulmonar/cirugía , Función Ventricular Derecha
11.
Artículo en Inglés | MEDLINE | ID: mdl-38211896

RESUMEN

OBJECTIVE: Severe congenital aortic valve pathology in the growing patient remains a challenging clinical scenario. Bicuspidization of the diseased aortic valve has proven to be a promising repair technique with acceptable durability. However, most understanding of the procedure is empirical and retrospective. This work seeks to design the optimal gross morphology associated with surgical bicuspidization with simulations based on the hypothesis that modifications to the free edge length cause or relieve stenosis. METHODS: Model bicuspid valves were constructed with varying free edge lengths and gross morphology. Fluid-structure interaction simulations were conducted in a single patient-specific model geometry. The models were evaluated for primary targets of stenosis and regurgitation. Secondary targets were assessed and included qualitative hemodynamics, geometric height, effective height, orifice area, and billow. RESULTS: Stenosis decreased with increasing free edge length and was pronounced with free edge length less than or equal to 1.3 times the annular diameter d. With free edge length 1.5d or greater, no stenosis occurred. All models were free of regurgitation. Substantial billow occurred with free edge length 1.7d or greater. CONCLUSIONS: Free edge length 1.5d or greater was required to avoid aortic stenosis in simulations. Cases with free edge length 1.7d or greater showed excessive billow and other changes in gross morphology. Cases with free edge length 1.5d to 1.6d have a total free edge length approximately equal to the annular circumference and appeared optimal. These effects should be studied in vitro and in animal studies.

12.
Gastrointest Endosc ; 99(6): 924-930, 2024 06.
Artículo en Inglés | MEDLINE | ID: mdl-38184116

RESUMEN

BACKGROUND AND AIMS: Opioid-induced esophageal dysfunction (OIED) often presents as spastic esophageal disorders (SEDs) and esophagogastric junction outflow obstruction (EGJOO). The aim of this study was to evaluate and compare clinical outcomes of peroral endoscopic myotomy (POEM) for SEDs and EGJOO among opioid users and nonusers. METHODS: This propensity score (PS) matching study included consecutive opioid users and nonusers who underwent POEM for SEDs and EGJOO between January 2018 and September 2022. The following covariates were used for the PS calculation: age, sex, duration of symptoms, Eckardt score, type of motility disorder, and length of myotomy during POEM. Clinical response was defined as a post-POEM Eckardt score ≤3. RESULTS: A total of 277 consecutive patients underwent POEM during the study period. PS matching resulted in the selection of 64 pairs of patients strictly matched 1:1 (n = 128) with no statistically significant differences in demographic, baseline, or procedural characteristics or in the parameters considered for the PS between the 2 groups. Clinical response to POEM was significantly lower among opioid users (51 of 64 [79.7%]) versus nonusers (60 of 64 [93.8%]) (P = .03) at a median follow-up of 18 months. Among opioid users, higher opioid dose (>60 morphine milligram equivalents per day) was associated with a higher likelihood of failure to respond to POEM (odds ratio, 4.59; 95% confidence interval, 1.31-3.98; P = .02). CONCLUSIONS: Clinical response to POEM for SEDs and EGJOO is significantly lower among opioid users versus nonusers. There was a dose-relationship between opioids and response to POEM, with higher daily opioid usage associated with a higher likelihood of treatment failure.


Asunto(s)
Trastornos de la Motilidad Esofágica , Miotomía , Puntaje de Propensión , Humanos , Femenino , Masculino , Persona de Mediana Edad , Adulto , Trastornos de la Motilidad Esofágica/cirugía , Miotomía/métodos , Miotomía/efectos adversos , Analgésicos Opioides/uso terapéutico , Cirugía Endoscópica por Orificios Naturales/métodos , Cirugía Endoscópica por Orificios Naturales/efectos adversos , Anciano , Estudios Retrospectivos , Resultado del Tratamiento , Trastornos Relacionados con Opioides/epidemiología , Esofagoscopía/métodos
13.
Pediatr Transplant ; 28(1): e14584, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37470130

RESUMEN

BACKGROUND: Pediatric heart transplantation (HT) continues to be limited by the shortage of donor organs, distance constraints, and the number of potential donor offers that are declined due to the presence of multiple risk factors. METHODS: We report a case of successful pediatric HT in which multiple risk factors were mitigated through a combination of innovative donor utilization improvement strategies. RESULTS: An 11-year-old, 25-kilogram child with cardiomyopathy and pulmonary hypertension, on chronic milrinone therapy and anticoagulated with apixaban, was transplanted with a heart from a Hepatitis C virus positive donor and an increased donor-to-recipient weight ratio. Due to extended geographic distance, an extracorporeal heart preservation system (TransMedics™ OCS Heart) was used for procurement. No significant bleeding was observed post-operatively, and she was discharged by post-operative day 15 with normal biventricular systolic function. Post-transplant Hepatitis C virus seroconversion was successfully treated. CONCLUSIONS: Heart transplantation in donors with multiple risk factor can be achieved with an integrative team approach and should be taken into consideration when evaluating marginal donors in order to expand the current limited donor pool in pediatric patients.


Asunto(s)
Trasplante de Corazón , Obtención de Tejidos y Órganos , Femenino , Humanos , Niño , Donantes de Tejidos , Corazón , Factores de Riesgo
14.
J Thorac Cardiovasc Surg ; 167(5): 1570-1580.e3, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37689234

RESUMEN

OBJECTIVE: We sought to simplify reporting of outcomes in congenital heart surgery that compares well-defined patient groups and accommodates multiple stakeholder needs while being easily understandable. METHODS: We selected 19 commonly performed congenital heart surgeries ranging in complexity from repair of atrial septal defects to the Norwood procedure. Strict inclusion/exclusion criteria ensured the creation of 19 well-defined diagnosis/procedure cohorts. Preoperative, procedural, and postoperative data were collected for consecutive eligible patients from 9 centers between January 1, 2016, and December 31, 2021. Unadjusted operative mortality rates and hospital length of stay for each of the 19 diagnosis/procedure cohorts were summarized in aggregate and stratified by each center. RESULTS: Of 8572 eligible cases included, numbers in the 19 diagnosis/procedure cohorts ranged from 73 for tetralogy of Fallot repair after previous palliation to 1224 for ventricular septal defect (VSD) repair for isolated VSD. In aggregate, the unadjusted mortality ranged from 0% for atrial septal defect repair to 28.4% for hybrid stage I. There was significant heterogeneity in case mix and mortality for different diagnosis/procedure cohorts across centers (eg, arterial switch operation/VSD, n = 7-42, mortality 0%-7.4%; Norwood procedure, n = 16-122, mortality 5.3%-25%). CONCLUSIONS: Reporting of institutional case volumes and outcomes within well-defined diagnosis/procedure cohorts can enable centers to benchmark outcomes, understand trends in mortality, and direct quality improvement. When made public, this type of report could provide parents with information on institutional volumes and outcomes and allow them to better understand the experience of each program with operations for specific congenital heart defects.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Cardiopatías Congénitas , Defectos del Tabique Interatrial , Defectos del Tabique Interventricular , Malus , Cirugía Torácica , Humanos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Cardiopatías Congénitas/cirugía , Defectos del Tabique Interventricular/cirugía , Defectos del Tabique Interatrial/cirugía
15.
Ann Thorac Surg ; 117(2): 378, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37952758
16.
ArXiv ; 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37961745

RESUMEN

Congenital heart disease (CHD) encompasses a spectrum of cardiovascular structural abnormalities, often requiring customized treatment plans for individual patients. Computational modeling and analysis of these unique cardiac anatomies can improve diagnosis and treatment planning and may ultimately lead to improved outcomes. Deep learning (DL) methods have demonstrated the potential to enable efficient treatment planning by automating cardiac segmentation and mesh construction for patients with normal cardiac anatomies. However, CHDs are often rare, making it challenging to acquire sufficiently large patient cohorts for training such DL models. Generative modeling of cardiac anatomies has the potential to fill this gap via the generation of virtual cohorts; however, prior approaches were largely designed for normal anatomies and cannot readily capture the significant topological variations seen in CHD patients. Therefore, we propose a type- and shape-disentangled generative approach suitable to capture the wide spectrum of cardiac anatomies observed in different CHD types and synthesize differently shaped cardiac anatomies that preserve the unique topology for specific CHD types. Our DL approach represents generic whole heart anatomies with CHD type-specific abnormalities implicitly using signed distance fields (SDF) based on CHD type diagnosis, which conveniently captures divergent anatomical variations across different types and represents meaningful intermediate CHD states. To capture the shape-specific variations, we then learn invertible deformations to morph the learned CHD type-specific anatomies and reconstruct patient-specific shapes. Our approach has the potential to augment the image-segmentation pairs for rarer CHD types for cardiac segmentation and generate cohorts of CHD cardiac meshes for computational simulation.

18.
ArXiv ; 2023 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-37808095

RESUMEN

OBJECTIVE: Severe congenital aortic valve pathology in the growing patient remains a challenging clinical scenario. Bicuspidization of the diseased aortic valve has proven to be a promising repair technique with acceptable durability. However, most understanding of the procedure is empirical and retrospective. This work seeks to design the optimal gross morphology associated with surgical bicuspidization with simulations, based on the hypothesis that modifications to the free edge length cause or relieve stenosis. METHODS: Model bicuspid valves were constructed with varying free edge lengths and gross morphology. Fluid-structure interaction simulations were conducted in a single patient-specific model geometry. The models were evaluated for primary targets of stenosis and regurgitation. Secondary targets were assessed and included qualitative hemodynamics, geometric height, effective height, orifice area and prolapse. RESULTS: Stenosis decreased with increasing free edge length and was pronounced with free edge length less than or equal to 1.3 times the annular diameter d. With free edge length 1.5d or greater, no stenosis occurred. All models were free of regurgitation. Substantial prolapse occurred with free edge length greater than or equal to 1.7d. CONCLUSIONS: Free edge length greater than or equal to 1.5d was required to avoid aortic stenosis in simulations. Cases with free edge length greater than or equal to 1.7d showed excessive prolapse and other changes in gross morphology. Cases with free edge length 1.5-1.6d have a total free edge length approximately equal to the annular circumference and appeared optimal. These effects should be studied in vitro and in animal studies.

19.
J Am Coll Cardiol ; 82(12): 1206-1222, 2023 09 19.
Artículo en Inglés | MEDLINE | ID: mdl-37704311

RESUMEN

BACKGROUND: We have followed a consistent, albeit evolving, strategy for the management of patients with pulmonary atresia or severe stenosis and major aortopulmonary collateral arteries (MAPCAs) that aims to achieve complete repair with low right ventricular pressure by completely incorporating blood supply and relieving stenoses to all lung segments. OBJECTIVES: The purpose of this study was to characterize our 20-year institutional experience managing patients with MAPCAs. METHODS: We reviewed all patients who underwent surgery for MAPCAs and biventricular heart disease from November 2001 through December 2021. RESULTS: During the study period, 780 unique patients underwent surgery. The number of new patients undergoing surgery annually was relatively steady during the first 15 years, then increased substantially thereafter. Surgery before referral had been performed in almost 40% of patients, more often in our recent experience than earlier. Complete repair was achieved in 704 patients (90%), 521 (67%) during the first surgery at our center, with a median right ventricular to aortic pressure ratio of 0.34 (25th, 75th percentiles: 0.28, 0.40). The cumulative incidence of mortality was 15% (95% CI: 12%-19%) at 10 years, with no difference according to era of surgery (P = 0.53). On multivariable Cox regression, Alagille syndrome (HR: 2.8; 95% CI: 1.4-5.7; P = 0.004), preoperative respiratory support (HR: 2.0; 95% CI: 1.2-3.3; P = 0.008), and palliative first surgery at our center (HR: 3.5; 95% CI: 2.3-5.4; P < 0.001) were associated with higher risk of death. CONCLUSIONS: In a growing pulmonary artery reconstruction program, with increasing volumes and an expanding population of patients who underwent prior surgery, outcomes of patients with pulmonary atresia or stenosis and MAPCAs have continued to improve.


Asunto(s)
Cardiopatías Congénitas , Atresia Pulmonar , Humanos , Aorta , Constricción Patológica , Arteria Pulmonar/cirugía , Atresia Pulmonar/cirugía
20.
Endoscopy ; 55(10): 976, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37757799
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA