1.
Acad Radiol ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38641450

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate and compare the effectiveness of contrast media subtraction and kidney stone detection between a virtual non-iodine reconstruction algorithm (VNI; PureCalcium) and a virtual non-contrast (VNC) algorithm in excretory phase photon-counting detector computed tomography (PCD-CT), using a 3D printed kidney phantom under various tube voltages and radiation doses. MATERIALS AND METHODS: A 3D-printed kidney phantom, holding Calcium Oxalate (CaOx) and uric acid stones within contrast-enhanced calyces, was created. The calyx density mirrored the average density observed in 200 excretory phase patients (916 HU at 110 kV). Imaging was conducted on a clinical dual-source PCD-CT at 120 kV and 140 kV, with radiation doses set at 5, 10, and 15 mGy. VNI and VNC algorithms were applied. Two blinded readers evaluated the image quality, along with the degree of contrast media and kidney stone subtraction, using visual scales. Krippendorff's alpha was calculated to determine inter-reader agreement, and the Chi-squared test was employed for comparing ordinal data. RESULTS: Reader 2 rated overall image quality higher for VNI than VNC (4.90 vs. 4.00; P < .05), while Reader 1 found no significant difference (4.96 vs. 5.00; P > .05). Substantial agreement was observed between readers for contrast media subtraction in both VNC and VNI (Krippendorff's alpha range: 0.628-0.748). Incomplete contrast media subtraction occurred more frequently with VNI for both readers (Reader 1: 29% vs. 15%; P < .05; Reader 2: 24% vs. 20%; P > .05). Uric acid and smaller stones (<5 mm) were more likely to be subtracted than CaOx and larger stones in both VNC and VNI. Overall, a higher rate of stone subtraction was noted with VNI compared to VNC (Reader 1: 22% vs. 16%; Reader 2: 25% vs. 10%; P < .05). Neither radiation dose nor tube voltage significantly influenced stone subtraction (P > .05). CONCLUSION: VNC demonstrated greater accuracy than VNI for contrast media subtraction and kidney stone visibility. Radiation dose and tube voltage had no significant impact. Nonetheless, both algorithms still exhibited frequent incomplete contrast media subtraction and partial kidney stone subtraction.

2.
Foot Ankle Int ; 45(5): 474-484, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38497521

RESUMEN

BACKGROUND: Plantar transfer ulcers (TUs) underneath the second metatarsal head are frequent after first metatarsal ray amputations due to diabetic foot infections. Whether the second metatarsal length (2ML) is associated with TU occurrence in these patients is unclear. This study evaluated whether 2ML is associated with TU occurrence after first-ray amputations and whether ulcer-free survival is shorter in patients with "excess" 2ML. METHODS: Forty-two patients with a mean age of 67 (range 33-93) years, diabetes, and first metatarsal ray amputation (first amputation at the affected foot) were included. Two independent readers measured the 2ML using the Coughlin method. A protrusion of more than 4.0 mm of the second metatarsal was defined as "excess" 2ML. The effect of 2ML on ulcer occurrence was analyzed using a multivariate Cox regression model. A Kaplan-Meier curve for TU-free survival was constructed comparing the 2 groups of "normal" (n = 21) and "excess" 2ML (n = 21). RESULTS: Interrater reliability was excellent. TUs underneath the second metatarsal occurred in 15 (36%) patients. In agreement with our hypothesis, 2ML was nonsignificantly different in patients with TUs, recording a mean of 5.3 (SD 2.5) mm, compared to patients without 4.0 (SD 2.3) mm (hazard ratio [HR] 1.12, 95% CI 0.89-1.41), whereas insulin dependence was associated with ulcer occurrence (HR 0.33, 95% CI 0.11-0.99). CONCLUSION: In our relatively small study population with a cutoff level of 4 mm for excess 2ML, ulcer-free survival was similar in patients with "normal" and "excess" 2ML. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Asunto(s)
Amputación Quirúrgica , Pie Diabético , Huesos Metatarsianos , Humanos , Pie Diabético/cirugía , Pie Diabético/complicaciones , Huesos Metatarsianos/cirugía , Anciano , Persona de Mediana Edad , Femenino , Masculino , Estudios Retrospectivos , Anciano de 80 o más Años , Adulto
3.
Eur J Radiol ; 166: 110981, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37478655

RESUMEN

PURPOSE: To assess image quality and detectability of interstitial lung changes using multiple radiation doses from the same chest CT scan of patients with suspected interstitial lung disease (ILD). METHOD: Retrospective study of consecutive adult patients with suspected ILD receiving unenhanced chest CT as single-energy dual-source acquisition at 100 kVp (Dual-split mode). 67% and 33% of the overall tube current time product were assigned to tube A and B, respectively. 100%-dose was 2.34 ± 0.97 mGy. Five different radiation doses (100%, 67%, 45%, 39%, 33%) were reconstructed from this single acquisition using linear-blending technique. Two blinded radiologists assessed reticulations, ground-glass opacities (GGO) and honeycombing as well as subjective image noise. Percentage agreement (PA) as compared to 100%-dose were calculated. Non-parametric statistical tests were used. RESULTS: A total of 228 patients were included (61.2 ± 14.6 years,146 female). PA was highest for honeycombing (>96%) and independent of dose reduction (P > 0.8). PA for reticulations and GGO decreased when reducing the radiation dose from 100% to 67% for both readers (reticulations: 83.3% and 93.9%; GGO: 87.7% and 79.8% for reader 1 and 2, respectively). Additional dose reduction did not significantly change PA for both readers (all P > 0.05). Subjective image noise increased with decreasing radiation dose (Spearman Rho of ρ = 0.34 and ρ = 0.53 for reader 1 and 2, respectively, P < 0.001). CONCLUSIONS: Radiation dose reduction had a stronger impact on subtle interstitial lung changes. Detectability decreased with initial dose reduction indicating that a minimum dose is needed to maintain diagnostic accuracy in chest CT for suspected ILD.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Tomografía Computarizada por Rayos X , Adulto , Humanos , Femenino , Estudios Retrospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Pulmón/diagnóstico por imagen
4.
Diagnostics (Basel) ; 13(9)2023 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-37175007

RESUMEN

(1) Background: Lung tissue involvement is frequently observed in acute COVID-19. However, it is unclear whether CT findings at follow-up are associated with persisting respiratory symptoms after initial mild or moderate infection. (2) Methods: Chest CTs of patients with persisting respiratory symptoms referred to the post-COVID-19 outpatient clinic were reassessed for parenchymal changes, and their potential association was evaluated. (3) Results: A total of 53 patients (31 female) with a mean (SD) age of 46 (13) years were included, of whom 89% had mild COVID-19. Median (quartiles) time from infection to CT was 139 (86, 189) days. Respiratory symptoms were dyspnea (79%), cough (42%), and thoracic pain (64%). Furthermore, 30 of 53 CTs showed very discrete and two CTs showed medium parenchymal abnormalities. No severe findings were observed. Mosaic attenuation (40%), ground glass opacity (2%), and fibrotic-like changes (25%) were recorded. No evidence for an association between persisting respiratory symptoms and chest CT findings was found. (4) Conclusions: More than half of the patients with initially mild or moderate infection showed findings on chest CT at follow-up. Respiratory symptoms, however, were not related to any chest CT finding. We, therefore, do not suggest routine chest CT follow-up in this patient group if no other indications are given.

5.
Radiol Cardiothorac Imaging ; 5(1): e220140, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36860835

RESUMEN

Purpose: To develop and evaluate a low-volume contrast media protocol for thoracoabdominal CT angiography (CTA) with photon-counting detector (PCD) CT. Materials and Methods: This prospective study included consecutive participants (April-September 2021) who underwent CTA with PCD CT of the thoracoabdominal aorta and previous CTA with energy-integrating detector (EID) CT at equal radiation doses. In PCD CT, virtual monoenergetic images (VMI) were reconstructed in 5-keV intervals from 40 to 60 keV. Attenuation of the aorta, image noise, and contrast-to-noise ratio (CNR) were measured, and subjective image quality was rated by two independent readers. In the first group of participants, the same contrast media protocol was used for both scans. CNR gain in PCD CT compared with EID CT served as the reference for contrast media volume reduction in the second group. Noninferiority analysis was used to test noninferior image quality of the low-volume contrast media protocol with PCD CT. Results: The study included 100 participants (mean age, 75 years ± 8 [SD]; 83 men). In the first group (n = 40), VMI at 50 keV provided the best trade-off between objective and subjective image quality, achieving 25% higher CNR compared with EID CT. Contrast media volume in the second group (n = 60) was reduced by 25% (52.5 mL). Mean differences in CNR and subjective image quality between EID CT and PCD CT at 50 keV were above the predefined boundaries of noninferiority (-0.54 [95% CI: -1.71, 0.62] and -0.36 [95% CI: -0.41, -0.31], respectively). Conclusion: CTA of the aorta with PCD CT was associated with higher CNR, which was translated into a low-volume contrast media protocol demonstrating noninferior image quality compared with EID CT at the same radiation dose.Keywords: CT Angiography, CT-Spectral, Vascular, Aorta, Contrast Agents-Intravenous, Technology Assessment© RSNA, 2023See also the commentary by Dundas and Leipsic in this issue.

6.
Diagnostics (Basel) ; 13(4)2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36832118

RESUMEN

BACKGROUND: To assess the impact of the lung cancer screening protocol recommended by the European Society of Thoracic Imaging (ESTI) on nodule diameter, volume, and density throughout different computed tomography (CT) scanners. METHODS: An anthropomorphic chest phantom containing fourteen different-sized (range 3-12 mm) and CT-attenuated (100 HU, -630 HU and -800 HU, termed as solid, GG1 and GG2) pulmonary nodules was imaged on five CT scanners with institute-specific standard protocols (PS) and the lung cancer screening protocol recommended by ESTI (ESTI protocol, PE). Images were reconstructed with filtered back projection (FBP) and iterative reconstruction (REC). Image noise, nodule density and size (diameter/volume) were measured. Absolute percentage errors (APEs) of measurements were calculated. RESULTS: Using PE, dosage variance between different scanners tended to decrease compared to PS, and the mean differences were statistically insignificant (p = 0.48). PS and PE(REC) showed significantly less image noise than PE(FBP) (p < 0.001). The smallest size measurement errors were noted with volumetric measurements in PE(REC) and highest with diametric measurements in PE(FBP). Volume performed better than diameter measurements in solid and GG1 nodules (p < 0.001). However, in GG2 nodules, this could not be observed (p = 0.20). Regarding nodule density, REC values were more consistent throughout different scanners and protocols. CONCLUSION: Considering radiation dose, image noise, nodule size, and density measurements, we fully endorse the ESTI screening protocol including the use of REC. For size measurements, volume should be preferred over diameter.

7.
Medicine (Baltimore) ; 102(7): e32917, 2023 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-36800631

RESUMEN

A major risk factor to develop active tuberculosis (TB) is the infection with the human immunodeficiency virus (HIV). Chest radiography is the first-line imaging modality used to rule out TB. Coinfected individuals present often with atypical imaging patterns, due to the immunosuppression caused by the virus, making diagnosis difficult. In this prospective observational study 268 TB and HIV coinfected patients were included. During a follow-up period of 24 weeks, the predominant patterns on chest radiography were analyzed and compared to the cluster of differentiation 4 (CD4) count under antiretroviral and anti-TB therapy. Patients with low CD4 counts (<200 cells//µL) showed more often lymphadenopathy (62% vs 38%;P = .08) and a miliary pattern (64% vs 36%;P = .04) but less likely cavitation (32% vs 68%;P = .008) or consolidation (47% vs 63%;P = .002) compared to individuals with higher CD4 counts. Over the follow-up period, partial response to therapy was the most frequent radiological evolution (62%), mainly accompanied by an increase of CD4 cells (92%). Patients with a decrease in CD4 count mostly presented with a worsening in radiological findings (53%). Radiographic TB manifestation correlated with the immune status of patients coinfected with HIV. Low CD4 counts often showed atypical manifestation.


Asunto(s)
Infecciones Oportunistas Relacionadas con el SIDA , Síndrome de Inmunodeficiencia Adquirida , Infecciones por VIH , Tuberculosis , Humanos , Síndrome de Inmunodeficiencia Adquirida/complicaciones , Infecciones Oportunistas Relacionadas con el SIDA/diagnóstico por imagen , Infecciones Oportunistas Relacionadas con el SIDA/complicaciones , Recuento de Linfocito CD4 , Infecciones por VIH/complicaciones , VIH-1 , Tuberculosis/complicaciones , Tuberculosis/diagnóstico por imagen
8.
Eur Radiol ; 33(7): 5077-5086, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36729173

RESUMEN

This statement from the European Society of Thoracic imaging (ESTI) explains and summarises the essentials for understanding and implementing Artificial intelligence (AI) in clinical practice in thoracic radiology departments. This document discusses the current AI scientific evidence in thoracic imaging, its potential clinical utility, implementation and costs, training requirements and validation, its' effect on the training of new radiologists, post-implementation issues, and medico-legal and ethical issues. All these issues have to be addressed and overcome, for AI to become implemented clinically in thoracic radiology. KEY POINTS: • Assessing the datasets used for training and validation of the AI system is essential. • A departmental strategy and business plan which includes continuing quality assurance of AI system and a sustainable financial plan is important for successful implementation. • Awareness of the negative effect on training of new radiologists is vital.


Asunto(s)
Inteligencia Artificial , Radiología , Humanos , Radiología/métodos , Radiólogos , Radiografía Torácica , Sociedades Médicas
9.
Diagn Interv Imaging ; 104(2): 84-90, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36216734

RESUMEN

PURPOSE: The purpose of this study was to evaluate the impact of virtual monoenergetic image (VMI) energies and iodine maps on the diagnosis of pleural empyema with photon counting detector computed tomography (PCD-CT). MATERIALS AND METHODS: In this IRB-approved retrospective study, consecutive patients with non-infectious pleural effusion or histopathology-proven empyema were included. PCD-CT examinations were performed on a dual-source PCD-CT in the multi-energy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast-agent. VMIs from 40-70 keV obtained in 10 keV intervals and an iodine map was reconstructed for each scan. CT attenuation was measured in the aorta, the pleura and the peripleural fat (between autochthonous dorsal muscles and dorsal ribs). Contrast-to-noise (CNR) and signal-to-noise (SNR) ratios were calculated. Two blinded radiologists evaluated if empyema was present (yes/no), and rated diagnostic confidence (1 to 4; not confident to fully confident, respectively) with and without using the iodine map. Sensitivity, specificity and diagnostic confidence were estimated. Interobserver agreement was estimated using an unweighted Cohen kappa test. A one-way ANOVA was used to compare variables. Differences in sensitivity and specificity between the different levels of energy were searched using McNemar test. RESULTS: Sixty patients (median age, 60 years; 26 women) were included. A strong negative correlation was found between image noise and VMI energies (r = -0.98; P = 0.001) and CNR increased with lower VMI energies (r = -0.98; P = 0.002). Diagnostic accuracy (96%; 95% CI: 82-100) as well as diagnostic confidence (3.4 ± 0.75 [SD]) were highest at 40 keV. Diagnostic accuracy and confidence at higher VMI energies improved with the addition of iodine maps (P ≤0.001). Overall, no difference in CT attenuation of peripleural fat between patients with empyema and those with pleural effusion was found (P = 0.07). CONCLUSION: Low VMI energies lead to a higher diagnostic accuracy and diagnostic confidence in the diagnosis of pleural empyema. Iodine maps help in diagnosing empyema only at high VMI energies.


Asunto(s)
Empiema Pleural , Yodo , Derrame Pleural , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Empiema Pleural/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos
10.
Diagnostics (Basel) ; 12(11)2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36359558

RESUMEN

Purpose: To assess the impact of virtual-monoenergetic-image (VMI) energies on the diagnosis of pulmonary embolism (PE) in photon-counting-detector computed-tomography (PCD-CT). Methods: Eighty patients (median age 60.4 years) with suspected PE were retrospectively included. Scans were performed on PCD-CT in the multi-energy mode at 120 kV. VMIs from 40−70 keV in 10 keV intervals were reconstructed. CT-attenuation was measured in the pulmonary trunk and the main branches of the pulmonary artery. Signal-to-noise (SNR) ratio was calculated. Two radiologists evaluated subjective-image-quality (noise, vessel-attenuation and sharpness; five-point-Likert-scale, non-diagnostic−excellent), the presence of hardening artefacts and presence/visibility of PE. Results: Signal was highest at the lowest evaluated VMI (40 keV; 1053.50 HU); image noise was lowest at the highest VMI (70 keV; 15.60 HU). Highest SNR was achieved at the lowest VMI (p < 0.05). Inter-reader-agreement for subjective analysis was fair to excellent (k = 0.373−1.000; p < 0.001). Scores for vessel-attenuation and sharpness were highest at 40 keV (both:5, range 4/3−5; k = 1.000); scores for image-noise were highest at 70 keV (4, range 3−5). The highest number of hardening artifacts were reported at 40 keV (n = 22; 28%). PE-visualization was rated best at 50 keV (4.7; range 4−5) and decreased with increasing VMI-energy (r = −0.558; p < 0.001). Conclusions: While SNR was best at 40 keV, subjective PE visibility was rated highest at 50 keV, potentially owing to the lower image noise and hardening artefacts.

11.
Eur J Radiol ; 156: 110549, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36272226

RESUMEN

PURPOSE: To assess the performance of semi-automated volumetry of solid pulmonary nodules on single-energy tin-filtered ultralow dose (ULD) chest CT scans at a radiation dose equivalent to chest X-ray relative to standard dose (SD) chest CT scans and assess the impact of kernel and iterative reconstruction selection. METHODS: Ninety-four consecutive patients from a prospective single-center study were included and underwent clinically indicated SD chest CT (1.9 ± 0.8 mSv) and additional ULD chest CT (0.13 ± 0.01 mSv) in the same session. All scans were reconstructed with a soft tissue (Br40) and lung (Bl64) kernel as well as with Filtered Back Projection (FBP) and Iterative Reconstruction (ADMIRE-3 and ADMIRE-5). One hundred and forty-eight solid pulmonary nodules were identified and analysed by semi-automated volumetry on all reconstructions. Nodule volumes were compared amongst all reconstructions thereby focusing on the agreement between SD and ULD scans. RESULTS: Nodule volumes ranged from 58.5 (28.8-126) mm3 for ADMIRE-5 Br40 ULD reconstructions to 72.5 (39-134) mm3 for FBP Bl64 SD reconstructions with significant differences between reconstructions (p < 0.001). Interscan agreement of volumes between two given reconstructions ranged from ICC = 0.605 to ICC = 0.999. Between SD and ULD scans, agreement of nodule volumes was highest for FBP Br40 (ICC = 0.995), FBP Bl64 (ICC = 0.939) and ADMIRE-5 Bl64 (ICC = 0.994) reconstructions. ADMIRE-3 reconstructions exhibited reduced interscan agreement of nodule volumes (ICCs from 0.788 - 0.882). CONCLUSIONS: The interscan agreement of node volumes between SD and ULD is high depending on the choice of kernel and reconstruction algorithm. However, caution should be exercised when comparing two image series that were not identically reconstructed.

12.
Diagnostics (Basel) ; 12(7)2022 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-35885565

RESUMEN

Background: Interstitial lung disease (ILD) is a frequent complication of systemic sclerosis (SSc), and its early detection and treatment may prevent deterioration of lung function. Different vendors have recently made larger image matrices available as a post-processing option for computed tomography (CT), which could facilitate the diagnosis of SSc-ILD. Therefore, the objective of this study was to assess the effect of matrix size on lung image quality in patients with SSc by comparing a 1024-pixel matrix to a standard 512-pixel matrix and applying different reconstruction kernels. Methods: Lung scans of 50 patients (mean age 54 years, range 23−85 years) with SSc were reconstructed with these two different matrix sizes, after determining the most appropriate kernel in a first step. Four observers scored the images on a five-point Likert scale regarding image quality and detectability of clinically relevant findings. Results: Among the eight tested kernels, the Br59-kernel (sharp) reached the highest score (19.48 ± 3.99), although differences did not reach statistical significance. The 1024-pixel matrix scored higher than the 512-pixel matrix HRCT overall (p = 0.01) and in the subcategories sharpness (p < 0.01), depiction of bronchiole (p < 0.01) and overall image impression (p < 0.01), and lower for the detection of ground-glass opacities (GGO) (p = 0.04). No significant differences were found for detection of extent of reticulations/bronchiectasis/fibrosis (p = 0.50) and image noise (p = 0.09). Conclusions: Our results show that with the use of a sharp kernel, the 1024-pixel matrix HRCT, provides a slightly better subjective image quality in terms of assessing interstitial lung changes, whereby GGO are more visible on the 512-pixel matrix. However, it remains to be answered to what extent this is related to the improved representation of the smallest structures.

13.
Radiology ; 305(1): 107-115, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35670712

RESUMEN

Background Accurate CT attenuation and diagnostic quality of virtual noncontrast (VNC) images acquired with photon-counting detector (PCD) CT are needed to replace true noncontrast (TNC) scans. Purpose To assess the attenuation errors and image quality of VNC images from abdominal PCD CT compared with TNC images. Materials and Methods In this retrospective study, consecutive adult patients who underwent a triphasic examination with PCD CT from July 2021 to October 2021 were included. VNC images were reconstructed from arterial and portal venous phase CT. The absolute attenuation error of VNC compared with TNC images was measured in multiple structures by two readers. Then, two readers blinded to image reconstruction assessed the overall image quality, image noise, noise texture, and delineation of small structures using five-point discrete visual scales (5 = excellent, 1 = nondiagnostic). Overall image quality greater than or equal to 3 was deemed diagnostic. In a phantom, noise texture, spatial resolution, and detectability index were assessed. A detectability index greater than or equal to 5 indicated high diagnostic accuracy. Interreader agreement was evaluated using the Krippendorff α coefficient. The paired t test and Friedman test were applied to compare objective and subjective results. Results Overall, 100 patients (mean age, 72 years ± 10 [SD]; 81 men) were included. In patients, VNC image attenuation values were consistent between readers (α = .60), with errors less than 5 HU in 76% and less than 10 HU in 95% of measurements. There was no evidence of a difference in error of VNC images from arterial or portal venous phase CT (3.3 HU vs 3.5 HU, P = .16). Subjective image quality was rated lower in VNC images for all categories (all, P < .001). Diagnostic quality of VNC images was reached in 99% and 100% of patients for readers 1 and 2, respectively. In the phantom, VNC images exhibited 33% higher noise, blotchier noise texture, similar spatial resolution, and inferior but overall good image quality (detectability index >20) compared with TNC images. Conclusion Abdominal virtual noncontrast images from the arterial and portal venous phase of photon-counting detector CT yielded accurate CT attenuation and good image quality compared with true noncontrast images. © RSNA, 2022 Online supplemental material is available for this article See also the editorial by Sosna in this issue.


Asunto(s)
Imagen Radiográfica por Emisión de Doble Fotón , Abdomen/diagnóstico por imagen , Adulto , Anciano , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
14.
J Thorac Imaging ; 37(4): W56-W57, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35749625

RESUMEN

The aim of our study was to assess the influence of overlapping image reconstruction on thin-section chest computed tomography (CT) in patients with small lung nodules. In all, 40 patients with 128 pulmonary nodules underwent chest CT on a third-generation dual-source CT. All images were reconstructed with a section thickness of 1 mm and an increment of 0.5 to 1 mm. Two readers performed volume measurements with a commercially available software package. Our data indicate no relevant differences (P=0.44) for volume measurements of solid lung nodules comparing overlapping (50% overlap) and nonoverlapping image reconstructions with a mean difference of 0.5±2.3 mm3 and a mean absolute difference of nodule volume of 2±2% (range, 0% to 11%). Interobserver differences were 1.0±3.7 mm3 (reconstruction with 50 overlap) and 1.1±4.1 mm3 (nonoverlapping reconstructions). Differences in nodule volume measurements between overlapping and nonoverlapping image reconstructions were similar compared with interobserver differences. Obviating the reconstruction of overlapping sections for lung nodule volume measurements would reduce the duration of image reconstruction and amount of data storage.


Asunto(s)
Neoplasias Pulmonares , Nódulo Pulmonar Solitario , Algoritmos , Humanos , Pulmón/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos
15.
Invest Radiol ; 57(12): 773-779, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35640003

RESUMEN

OBJECTIVE: The aim of this study was to determine the potential of photon-counting detector computed tomography (PCD-CT) for radiation dose reduction compared with conventional energy-integrated detector CT (EID-CT) in the assessment of interstitial lung disease (ILD) in systemic sclerosis (SSc) patients. METHODS: In this retrospective study, SSc patients receiving a follow-up noncontrast chest examination on a PCD-CT were included between May 2021 and December 2021. Baseline scans were generated on a dual-source EID-CT by selecting the tube current-time product for each of the 2 x-ray tubes to obtain a 100% (D 100 ), a 66% (D 66 ), and a 33% dose image (D 33 ) from the same data set. Slice thickness and kernel were adjusted between the 2 scans. Image noise was assessed by placing a fixed region of interest in the subcutaneous fat. Two independent readers rated subjective image quality (5-point Likert scale), presence, extent, diagnostic confidence, and accuracy of SSc-ILD. D 100 interpreted by a radiologist with 22 years of experience served as reference standard. Interobserver agreement was calculated with Cohen κ, and mean variables were compared by a paired t test. RESULTS: Eighty patients (mean 56 ± 14; 64 women) were included. Although CTDI vol of PCD-CT was comparable to D 33 (0.72 vs 0.76 mGy, P = 0.091), mean image noise of PCD-CT was comparable to D 100 (131 ± 15 vs 113 ± 12, P > 0.05). Overall subjective image quality of PCD-CT was comparable to D 100 (4.72 vs 4.71; P = 0.874). Diagnostic accuracy was higher in PCD-CT compared with D 33 /D 66 (97.6% and 92.5%/96.3%, respectively) and comparable to D 100 (98.1%). CONCLUSIONS: With PCD-CT, a radiation dose reduction of 66% compared with EID-CT is feasible, without penalty in image quality and diagnostic performance for the evaluation of ILD.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Esclerodermia Sistémica , Humanos , Femenino , Fantasmas de Imagen , Fotones , Reducción Gradual de Medicamentos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Esclerodermia Sistémica/complicaciones , Esclerodermia Sistémica/diagnóstico por imagen
16.
Radiologie (Heidelb) ; 62(9): 758-762, 2022 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-35362727

RESUMEN

BACKGROUND: Tobacco use is the leading preventable cause of cancer and cancer deaths. Tobacco use is not only related to lung cancer, but has an impact on a wide range of different cancer entities in almost every organ system. OBJECTIVES: The aim of this review article is to shed light on the different organ systems involved in tobacco-associated carcinogenesis. MATERIALS AND METHODS: For this purpose, first a brief introduction into the topic is given, followed by a detailed description of the different tumor entities associated with tobacco use. RESULTS: Tobacco consumption has been clearly implicated in the causation of many types of cancer, affecting multiple organ systems. Based on current evidence, tobacco use can cause cancer of the mouth and throat, larynx, esophagus, stomach, kidney, pancreas, liver, bladder, cervix, colon and rectum, and acute myeloid leukemia. CONCLUSION: Tobacco use is not only main cause in the development of lung cancer, but has a major impact in the development of cancer in other organ systems. Therefore, special attention must be given to possible concomitant malignancies when evaluating images of smokers.


Asunto(s)
Neoplasias Pulmonares , Contaminación por Humo de Tabaco , Neoplasias Pulmonares/epidemiología , Fumar/efectos adversos , Nicotiana , Uso de Tabaco
17.
Br J Radiol ; 95(1135): 20211367, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-35357902

RESUMEN

OBJECTIVE: To evaluate the performance of virtual non-contrast images (VNC) compared to true non-contrast (TNC) images in photon-counting detector computed tomography (PCD-CT) for the evaluation of lung parenchyma and emphysema quantification. METHODS: 65 (mean age 73 years; 48 male) consecutive patients who underwent a three-phase (non-contrast, arterial and venous) chest/abdomen CT on a first-generation dual-source PCD-CT were retrospectively included. Scans were performed in the multienergy (QuantumPlus) mode at 120 kV with 70 ml intravenous contrast agent at an injection rate of 4 ml s-1. VNC were reconstructed from the arterial (VNCart) and venous phase (VNCven). TNC and VNC images of the lung were assessed quantitatively by calculating the global noise index (GNI) and qualitatively by two independent, blinded readers (overall image quality and emphysema assessment). Emphysema quantification was performed using a commercially available software tool at a threshold of -950 HU for all data sets. TNC images served as reference standard for emphysema quantification. Low attenuation values (LAV) were compared in a Bland-Altman plot. RESULTS: GNI was similar in VNCart (103.0 ± 30.1) and VNCven (98.2 ± 22.2) as compared to TNC (100.9 ± 19.0, p = 0.546 and p = 0.272, respectively). Subjective image quality (emphysema assessment and overall image quality) was highest for TNC (p = 0.001), followed by VNCven and VNCart. Both, VNCart and VNCven showed no significant difference in emphysema quantification as compared to TNC (p = 0.409 vs. p = 0.093; respectively). CONCLUSION: Emphysema evaluation is feasible using virtual non-contrast images from PCD-CT. ADVANCES IN KNOWLEDGE: Emphysema quantification is feasible and accurate using VNC images in PCD-CT. Based on these findings, additional TNC scans for emphysema quantification could be omitted in the future.


Asunto(s)
Enfisema , Tomografía Computarizada por Rayos X , Abdomen , Anciano , Enfisema/diagnóstico por imagen , Humanos , Masculino , Estudios Retrospectivos , Tórax , Tomografía Computarizada por Rayos X/métodos
18.
Diagnostics (Basel) ; 12(2)2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-35204611

RESUMEN

The aim of this study was to characterize image quality and to determine the optimal strength levels of a novel iterative reconstruction algorithm (quantum iterative reconstruction, QIR) for low-dose, ultra-high-resolution (UHR) photon-counting detector CT (PCD-CT) of the lung. Images were acquired on a clinical dual-source PCD-CT in the UHR mode and reconstructed with a sharp lung reconstruction kernel at different strength levels of QIR (QIR-1 to QIR-4) and without QIR (QIR-off). Noise power spectrum (NPS) and target transfer function (TTF) were analyzed in a cylindrical phantom. 52 consecutive patients referred for low-dose UHR chest PCD-CT were included (CTDIvol: 1 ± 0.6 mGy). Quantitative image quality analysis was performed computationally which included the calculation of the global noise index (GNI) and the global signal-to-noise ratio index (GSNRI). The mean attenuation of the lung parenchyma was measured. Two readers graded images qualitatively in terms of overall image quality, image sharpness, and subjective image noise using 5-point Likert scales. In the phantom, an increase in the QIR level slightly decreased spatial resolution and considerably decreased noise amplitude without affecting the frequency content. In patients, GNI decreased from QIR-off (202 ± 34 HU) to QIR-4 (106 ± 18 HU) (p < 0.001) by 48%. GSNRI increased from QIR-off (4.4 ± 0.8) to QIR-4 (8.2 ± 1.6) (p < 0.001) by 87%. Attenuation of lung parenchyma was highly comparable among reconstructions (QIR-off: -849 ± 53 HU to QIR-4: -853 ± 52 HU, p < 0.001). Subjective noise was best in QIR-4 (p < 0.001), while QIR-3 was best for sharpness and overall image quality (p < 0.001). Thus, our phantom and patient study indicates that QIR-3 provides the optimal iterative reconstruction level for low-dose, UHR PCD-CT of the lungs.

19.
Diagnostics (Basel) ; 12(1)2022 Jan 03.
Artículo en Inglés | MEDLINE | ID: mdl-35054268

RESUMEN

BACKGROUND: We evaluated the prognostic value of Sarcopenia, low precardial adipose-tissue (PAT), and high tumor-volume in the outcome of surgically-treated pleural mesothelioma (PM). METHODS: From 2005 to 2020, consecutive surgically-treated PM-patients having a pre-operative computed tomography (CT) scan were retrospectively included. Sarcopenia was assessed by CT-based parameters measured at the level of the fifth thoracic vertebra (TH5) by excluding fatty-infiltration based on CT-attenuation. The findings were stratified for gender, and a threshold of the 33rd percentile was set to define sarcopenia. Additionally, tumor volume as well as PAT were measured. The findings were correlated with progression-free survival and long-term mortality. RESULTS: Two-hundred-seventy-eight PM-patients (252 male; 70.2 ± 9 years) were included. The mean progression-free survival was 18.6 ± 12.2 months, and the mean survival time was 23.3 ± 24 months. Progression was associated with chronic obstructive pulmonary disease (COPD) (p = <0.001), tumor-stage (p = 0.001), and type of surgery (p = 0.026). Three-year mortality was associated with higher patient age (p = 0.005), presence of COPD (p < 0.001), higher tumor-stage (p = 0.015), and higher tumor-volume (p < 0.001). Kaplan-Meier statistics showed that sarcopenic patients have a higher three-year mortality (p = 0.002). While there was a negative correlation of progression-free survival and mortality with tumor volume (r = 0.281, p = 0.001 and r = -0.240, p < 0.001; respectively), a correlation with PAT could only be shown for epithelioid PM (p = 0.040). CONCLUSIONS: Sarcopenia as well as tumor volume are associated with long-term mortality in surgically treated PM-patients. Further, while there was a negative correlation of progression-free survival and mortality with tumor volume, a correlation with PAT could only be shown for epithelioid PM.

20.
Invest Radiol ; 57(6): 359-365, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35066533

RESUMEN

PURPOSE: The aim of this study was to evaluate the impact of contrast enhancement and different virtual monoenergetic image energies on automatized emphysema quantification with photon-counting detector computed tomography (PCD-CT). MATERIAL AND METHODS: Sixty patients who underwent contrast-enhanced chest CT on a first-generation, clinical dual-source PCD-CT were retrospectively included. Scans were performed in the multienergy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast agent. Virtual noncontrast (VNC) images as well as virtual monoenergetic images (VMIs) from 40 to 80 keV obtained in 10-keV intervals were reconstructed. Computed tomography attenuation was measured in the aorta. Noise was measured in subcutaneous fat and defined as the standard deviation of attenuation. Contrast-to-noise with region of interest in the ascending aorta and signal-to-noise ratio in the subcutaneous fat were calculated. Subjective image quality (and emphysema assessment, lung parenchyma evaluation, and vessel evaluation) was rated by 2 blinded radiologists. Emphysema quantification (with a threshold of -950 HU) was performed by a commercially available software. Virtual noncontrast images served as reference standard for emphysema quantification. RESULTS: Noise and contrast-to-noise ratio showed a strong negative correlation (r = -0.98; P < 0.01) to VMI energies. The score of subjective assessment was highest at 70 keV for lung parenchyma and 50 keV for pulmonary vessel evaluation (P < 0.001). The best trade-off for the assessment of emphysema while maintaining reasonable contrast for pulmonary vessel evaluation was determined between 60 and 70 keV. Overall, contrast-enhanced imaging led to significant and systematic underestimation of emphysema as compared with VNC (P < 0.001). This underestimation decreased with increasing VMI-energy (r = 0.98; P = 0.003). Emphysema quantification showed significantly (P < 0.05) increased emphysema volumes with increasing VMI energies, except between 60-70 keV and 70-80 keV. The least difference in emphysema quantification between contrast-enhanced scans and VNC was found at 80 keV. CONCLUSION: Computed tomography emphysema quantification was significantly affected by intravenous contrast administration and VMI-energy level. Virtual monoenergetic image at 80 keV yielded most comparable results to VNC. The best trade-off in qualitative as well as in quantitative image quality evaluation was determined at 60/70 keV.


Asunto(s)
Enfisema , Imagen Radiográfica por Emisión de Doble Fotón , Aorta , Medios de Contraste , Enfisema/diagnóstico por imagen , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos