Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Base de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Bioelectromagnetics ; 33(1): 23-39, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21647932

RESUMEN

Terrestrial Trunked Radio (TETRA) technology ("Airwave") has led to public concern because of its potential interference with electrical activity in the brain. The present study is the first to examine whether acute exposure to a TETRA base station signal has an impact on cognitive functioning and physiological responses. Participants were exposed to a 420 MHz TETRA signal at a power flux density of 10 mW/m(2) as well as sham (no signal) under double-blind conditions. Fifty-one people who reported a perceived sensitivity to electromagnetic fields as well as 132 controls participated in a double-blind provocation study. Forty-eight sensitive and 132 control participants completed all three sessions. Measures of short-term memory, working memory, and attention were administered while physiological responses (blood volume pulse, heart rate, skin conductance) were monitored. After applying exclusion criteria based on task performance for each aforementioned cognitive measure, data were analyzed for 36, 43, and 48 sensitive participants for these respective tasks and, likewise, 107,125, and 129 controls. We observed no differences in cognitive performance between sham and TETRA exposure in either group; physiological response also did not differ between the exposure conditions. These findings are similar to previous double-blind studies with other mobile phone signals (900-2100 MHz), which could not establish any clear evidence that mobile phone signals affect health or cognitive function.


Asunto(s)
Cognición/efectos de la radiación , Campos Electromagnéticos/efectos adversos , Exposición a Riesgos Ambientales/efectos adversos , Fenómenos Fisiológicos/efectos de la radiación , Ondas de Radio/efectos adversos , Telecomunicaciones/instrumentación , Adulto , Volumen Sanguíneo/efectos de la radiación , Femenino , Respuesta Galvánica de la Piel/efectos de la radiación , Frecuencia Cardíaca/efectos de la radiación , Humanos , Masculino , Memoria/efectos de la radiación , Tolerancia a Radiación
2.
Environ Health Perspect ; 118(6): 735-41, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20075020

RESUMEN

BACKGROUND: "Airwave" is the new communication system currently being rolled out across the United Kingdom for the police and emergency services, based on the Terrestrial Trunked Radio Telecommunications System (TETRA). Some police officers have complained about skin rashes, nausea, headaches, and depression as a consequence of using their Airwave handsets. In addition, a small subgroup in the population self-report being sensitive to electromagnetic fields (EMFs) in general. OBJECTIVES: We conducted a randomized double-blind provocation study to establish whether short-term exposure to a TETRA base station signal has an impact on the health and well-being of individuals with self-reported "electrosensitivity" and of participants who served as controls. METHODS: Fifty-one individuals with self-reported electrosensitivity and 132 age- and sex-matched controls participated in an open provocation test; 48 sensitive and 132 control participants went on to complete double-blind tests in a fully screened semianechoic chamber. Heart rate, skin conductance, and blood pressure readings provided objective indices of short-term physiological response. Visual analog scales and symptom scales provided subjective indices of well-being. RESULTS: We found no differences on any measure between TETRA and sham (no signal) under double-blind conditions for either controls or electrosensitive participants, and neither group could detect the presence of a TETRA signal at rates greater than chance (50%). When conditions were not double blind, however, the self-reported electrosensitive individuals did report feeling worse and experienced more severe symptoms during TETRA compared with sham. CONCLUSIONS: Our findings suggest that the adverse symptoms experienced by electrosensitive individuals are due to the belief of harm from TETRA base stations rather than to the low-level EMF exposure itself.


Asunto(s)
Campos Electromagnéticos/efectos adversos , Telecomunicaciones/instrumentación , Análisis de Varianza , Presión Sanguínea/efectos de la radiación , Método Doble Ciego , Respuesta Galvánica de la Piel/efectos de la radiación , Frecuencia Cardíaca/efectos de la radiación , Distribución Aleatoria , Reino Unido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA