Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Magn Reson Imaging ; 101: 25-34, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37015305

RESUMEN

MR fingerprinting (MRF) enables fast multiparametric quantitative imaging with a single acquisition and has been shown to improve diagnosis of prostate cancer. However, most prostate MRF studies were performed with spiral acquisitions that are sensitive to B0 inhomogeneities and consequent blurring. In this work, a radial MRF acquisition with a novel subspace reconstruction technique was developed to enable fast T1/T2 mapping in the prostate in under 4 min. The subspace reconstruction exploits the extensive temporal correlations in the MRF dictionary to pre-compute a low dimensional space for the solution and thus reduce the number of radial spokes to accelerate the acquisition. Iterative reconstruction with the subspace model and additional regularization of the signal representation in the subspace is performed to minimize the number of spokes and maintain matching quality and SNR. Reconstruction accuracy was assessed using the ISMRM NIST phantom. In-vivo validation was performed on two healthy subjects and two prostate cancer patients undergoing radiation therapy. The longitudinal repeatability was quantified using the concordance correlation coefficient (CCC) in one of the healthy subjects by repeated scans over 1 year. One prostate cancer patient was scanned at three time points, before initiating therapy and following brachytherapy and external beam radiation. Changes in the T1/T2 maps obtained with the proposed method were quantified. The prostate, peripheral and transitional zones, and visible dominant lesion were delineated for each study, and the statistics and distribution of the quantitative mapping values were analyzed. Significant image quality improvements compared with standard reconstruction methods were obtained with the proposed subspace reconstruction method. A notable decrease in the spread of the T1/T2 values without biasing the estimated mean values was observed with the subspace reconstruction and agreed with reported literature values. The subspace reconstruction enabled visualization of small differences in T1/T2 values in the tumor region within the peripheral zone. Longitudinal imaging of a volunteer subject yielded CCC of 0.89 for MRF T1, and 0.81 for MRF T2 in the prostate gland. Longitudinal imaging of the prostate patient confirmed the feasibility of capturing radiation treatment related changes. This work is a proof-of-concept for a high resolution and fast quantitative mapping using golden-angle radial MRF combined with a subspace reconstruction technique for longitudinal treatment response assessment in subjects undergoing radiation treatment.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Voluntarios Sanos , Procesamiento de Imagen Asistido por Computador/métodos , Encéfalo
2.
Magn Reson Med ; 85(6): 3060-3070, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33604921

RESUMEN

PURPOSE: Non-Cartesian imaging sequences involve sampling during rapid variation of the encoding field gradients. The quality of the reconstructed images often suffers from insufficient knowledge of the exact dynamics of the actual fields applied during sampling. METHODS: We propose determination of the accurate field dynamics by measuring the currents at the gradient amplifier outputs using the amplifiers' internal sensors concurrently with imaging. The actual dynamic field evolution is then determined by convolution with the measured current-to-field impulse response function of the gradient coil. Integration of the gradient field evolution allows derivation of the k-space trajectory for reconstruction. RESULTS: The current-based approach is investigated in spiral and ultrashort TE phantom imaging. In comparison with the model-based product reconstruction as well as a correction approach based on the conventional input waveform-to-field impulse response function, it provides slightly improved image quality. The improvement is ascribed to a better representation of eddy current and amplifier nonlinearity effects. CONCLUSION: Trajectory calculation based on measured amplifier output currents offers a robust, purely measurement-based alternative to conventional model-based approaches. The implementation can mitigate gradient amplifier imperfections with no or little additional hardware effort.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador , Algoritmos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Lectura
3.
Magn Reson Med ; 82(6): 2146-2159, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31321818

RESUMEN

PURPOSE: To provide a simple tool for rapid measurement of the 3D gradient modulation transfer function (GMTF) of clinical MRI systems using a phantom. Knowledge of the transfer function is useful for gradient chain characterization, system calibration, and improvement of image reconstruction results. METHODS: Starting from the well-established thin slice method used for phantom-based measurement of the 1D GMTF, we add phase encoding to partition the thin slices into voxels that act as localized field probes. From the signal phase evolution measured at the 3D voxel positions, the GMTF can be derived for cross and higher order spatial terms represented by spherical harmonics up to 3rd order. RESULTS: Using spherical phantoms, 16 GMTFs representing all terms up to 3rd order harmonics can be determined in a scan time of <2 min. A large voxel volume of >1 mL yields high SNR, enabling signal acquisition using the system's body coil. The method is applied for improving system calibration and for characterizing the effect of additional hardware in the bore. CONCLUSION: The presented method seems well-suited for rapid measurement of the GMTF of a clinical system, as it delivers high-quality results in a short scan time.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Algoritmos , Calibración , Humanos , Modelos Estadísticos , Fantasmas de Imagen , Relación Señal-Ruido
4.
Magn Reson Med ; 66(4): 1116-22, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21394779

RESUMEN

Fluorine MRI offers broad potential for specific detection and quantification of molecularly targeted agents in diagnosis and therapy planning or monitoring. Because non-proton MRI applications lack morphological information, accompanying proton images are needed to elucidate the spatial tissue context. Furthermore, low concentrations typical of targeted molecular imaging agents require long examinations for signal averaging during which physiological motion may lead to blurring, underestimation in signal quantification, and erroneous localization of the agent distribution. Novel methods for truly simultaneous acquisition of dual-nuclei MR data are presented that offer efficient and precise anatomical localization of fluorine signals using accurate motion correction based on contemporaneous proton signals. The feasibility of simultaneous dual-nuclei MRI motion correction and corresponding dual-resolution reconstruction, providing nuclei-specific spatial resolution to retrospectively optimize the balance between signal-to-noise ratio and resolution, is shown on a clinical 3 T MR system.


Asunto(s)
Flúor , Imagen por Resonancia Magnética/métodos , Animales , Medios de Contraste , Imagenología Tridimensional , Imagen por Resonancia Magnética/instrumentación , Ratones , Ratones Endogámicos C57BL , Movimiento (Física) , Fantasmas de Imagen
5.
Rev Sci Instrum ; 79(6): 064302, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18601421

RESUMEN

A multichannel spectrally resolved optical tomography system to image molecular targets in small animals from within a clinical MRI is described. Long source/detector fibers operate in contact mode and couple light from the tissue surface in the magnet bore to 16 spectrometers, each containing two optical gratings optimized for the near infrared wavelength range. High sensitivity, cooled charge coupled devices connected to each spectrograph provide detection of the spectrally resolved signal, with exposure times that are automated for acquisition at each fiber. The design allows spectral fitting of the remission light, thereby separating the fluorescence signal from the nonspecific background, which improves the accuracy and sensitivity when imaging low fluorophore concentrations. Images of fluorescence yield are recovered using a nonlinear reconstruction approach based on the diffusion approximation of photon propagation in tissue. The tissue morphology derived from the MR images serves as an imaging template to guide the optical reconstruction algorithm. Sensitivity studies show that recovered values of indocyanine green fluorescence yield are linear to concentrations of 1 nM in a 70 mm diameter homogeneous phantom, and detection is feasible to near 10 pM. Phantom data also demonstrate imaging capabilities of imperfect fluorophore uptake in tissue volumes of clinically relevant sizes. A unique rodent MR coil provides optical fiber access for simultaneous optical and MR data acquisition of small animals. A pilot murine study using an orthotopic glioma tumor model demonstrates optical-MRI imaging of an epidermal growth factor receptor targeted fluorescent probe in vivo.


Asunto(s)
Algoritmos , Fluorescencia , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Sensibilidad y Especificidad
6.
MAGMA ; 19(6): 297-304, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17124611

RESUMEN

OBJECT: Multiple contrasts are often helpful for a comprehensive diagnosis. In 3D abdominal MRI, breath-hold techniques are preferred for single contrast acquisitions to avoid respiratory artifacts. In this paper, highly accelerated parallel MRI is used to acquire large 3D abdominal volumes with two different contrasts within a single breath-hold. MATERIAL AND METHODS: In vivo studies have been performed on six healthy volunteers, combining T (1)- and T (2)-weighted, gradient- or spin-echo based scans, as well as water/fat resolved imaging in a single breath-hold. These 3D scans were acquired with an acceleration factor of six, using a prototype 32-element receive array. RESULTS: The presented approach was tested successfully on all volunteers. The whole liver area was covered by a FOV of 350 x 250 x 200 mm(3) for all scans with reasonable spatial resolution. Arbitrary scan protocols generating different contrasts have been shown to be combinable in this single breath-hold approach. Good spatial correspondence with negligible spatial offset was achieved for all different scan combinations acquired in overall breath-hold times between 15 and 25 s. CONCLUSION: Enabled by highly parallel imaging technology, this study demonstrates the technical feasibility and the promising image quality of single breath-hold dual contrast MRI.


Asunto(s)
Abdomen/anatomía & histología , Medios de Contraste , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Hígado/anatomía & histología , Imagen por Resonancia Magnética/métodos , Estudios de Factibilidad , Humanos , Mecánica Respiratoria
7.
J Magn Reson Imaging ; 23(5): 752-6, 2006 May.
Artículo en Inglés | MEDLINE | ID: mdl-16557495

RESUMEN

PURPOSE: To set up a robust and patient-friendly whole-heart protocol based on 32-receive-channel technology that will potentially allow a large part of the patient population to be addressed. MATERIALS AND METHODS: Ten volunteers were examined on a clinical 1.5 T scanner equipped with a 32-channel data acquisition system using an experimental 32-element coil array. A magnetization-prepared, navigator-gated and -tracked 3D Cartesian balanced FFE sequence was used for whole-heart coronary MR angiography (MRA). With the use of sensitivity encoding (SENSE) and partial Fourier encoding for scan acceleration, nearly isotropic high-resolution data sets were acquired during free breathing in four minutes. RESULTS: A high contrast and sufficient signal-to-noise ratio (SNR) were obtained, which allowed visualization of the major vessels up to the distal regions and detection of major branches. Phase encoding in the anterior-posterior (AP) direction was the most favorable SENSE configuration and allowed a reasonable scan time reduction with moderate SENSE factors. CONCLUSION: The employed 32-receive channel technology enabled a robust trade-off among SNR, spatial resolution, and scan time. In this study the most robust results were obtained using the smallest possible SENSE factors for a given voxel size and scan time.


Asunto(s)
Angiografía Coronaria/métodos , Vasos Coronarios/anatomía & histología , Angiografía por Resonancia Magnética/métodos , Respiración , Adulto , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA